• 제목/요약/키워드: underground power cable

검색결과 321건 처리시간 0.033초

발전기 운전조건을 고려한 조상설비계획 (Shunt Compensator Planning considering generator's operating condition)

  • 이철휴;이상호;박종근;이송근;김홍균;이석진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1496-1498
    • /
    • 1999
  • The line charging is becoming larger due to the expansion of underground cable and extra high voltage lines. It causes reactive power surplus at light load condition which may force generators to operate reluctantly in the under excited mode. This paper proposes the pratical criteria and methodolgy for the shunt reactor planning while suppressing generator's under excited operation.

  • PDF

배전용 전력케이블의 반도전층에 함유되어 있는 불순물 분석 (Impurities of the Semiconductive Shield in the Power Distribution Cable)

  • 김상준;송일근;김주용;한재흥;서광석;이창용;이창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1794-1796
    • /
    • 1996
  • In order to evaluate the soundness of 10 year service-aged XLPE-insulated 22.9 kV underground distribution cables, semiconductive shields have been characterized. The edge of insulation near the insulation shield shows a drastic decrease of OIT. Impurities such as Ca, Mg, Fe, Cu were detected in both conductor and insulation shields. Their concentrations at the insulation shield are much higher than those at the strand shield. All these facts suggest that the edge of insulation near the insulation shield is degraded considerably, which might be attributed to the oxidation reaction of insulation by a large amount of impurities in the insulation shield.

  • PDF

하이브리드 혼합송전계통에서 고조파분석에 의한 DC 케이블 적정 배열 선정 (Proper Arrangement Selection of Underground DC Power Cable through Harmonics Analysis in Hybrid Combined Transmission System)

  • 손용대;고광만;채직병;이재명;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.367-368
    • /
    • 2015
  • 최근에 인도와 유럽을 중심으로 기존의 AC 송전계통 중 일부를 DC 송전계통으로 대체하는 하이브리드형 송전방식에 대한 연구가 진행중이다. 따라서 본 연구는 기존에 연구되고 있는 하이브리드형 가공송전계통을 기반으로 지중송전계통을 포함한 하이브리드형 혼합송전계통이 향후 머지않아 국내에서 계획 및 건설될 것을 대비한 초기 연구로서 진행하였다. 본 논문의 관점은 하이브리드 혼합송전계통 중 지중송전계통구간에서 DC 선로가 AC선로로부터 얼마나 고조파 전압 및 전류 측면에서 영향을 받는가를 평가하고, 이를 근거로 DC 케이블의 배열을 선정하고자 한다. 또한 DC 케이블 배열 선정을 위해 가능성이 있는 여러 개의 CASE별로 구분하고, 가장 타당한다고 평가되는 배열을 제안하고자한다. 본 연구에서 계통 모델링 및 해석은 EMTP를 이용하였다.

  • PDF

지중케이블 상별 거리차에 따른 VLF PD 위치 분석 방안 (Analysis method of VLF PD location by length differences between phase of underground power cable)

  • 목영수;이재득
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1495-1498
    • /
    • 2015
  • 지중전력케이블의 VLF PD 진단은 케이블의 절연체 공극이나 수투리가 진전되어 전기트리로 발전한 불량 부분에서 발생하는 부분방전량 및 발생 위치를 거리로 나타내 주는 방식이다. 케이블에 고전압을 인가하기 전 교정 작업을 시행하여 접속재의 위치, 긍장, 전파정수 등, 진단 구간에 대한 제반 정수를 장비에 입력하는 과정을 거친다. 지중케이블은 일반적으로 3상이 모두 동일한 길이로 포설되어 1상에 대해서만 교정 작업을 시행하고 있다. 교정 작업 시 입력하는 긍장 및 접속 재 위치는 3상 케이블에 대해 동일한 위치로 입력되기 때문에 과거에 어떠한 사정으로 상별 긍장이 상이 할 경우 PD 발생 위치가 다르게 나타날 수 있다. 이러한 오류를 범하지 않도록 하기 위하여 진단 중 발생하는 3상 케이블에 대한 단말 파형과 기타 위치를 알 수 있는 방법을 제시하여 PD 발생 위치를 수정하므로서 진단의 정확도를 높이는 방법이다.

  • PDF

경년열화된 지중 MV급 케이블의 Aging Index (A Health Index of Aged Undeground MV Cables in Domestic)

  • 김용현;김수환;이승원;임장섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1216-1216
    • /
    • 2015
  • In this study, the author apply the VLF(Very Low Frequency) tan-delta data that has been measured at each office of the KEPCO 2012 to the Weibull distribution which is the statistical analysis as previous studies for the remaining life prediction through the improvement of the sensitivity and reliability of the degradation state assessment of underground distribution power cables. Also, in this paper, UCD(Used Cable Diagnosis) Matrix proposed by KEPCO was applied to the hierarchy of assessment prioritization. it suggests Aging Index for condition assessment and high reliability of proper economic replacement cycle using the weight according to the assessment prioritization.

  • PDF

과천지역의 상세 토양비저항도(1/5000) 작성 (Development of Detailed Soil Resistivity Map(1/5000) in Kwachon)

  • 이현구;김대경;배정효;하태현;정성환;최상봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.315-317
    • /
    • 1999
  • Soil resistivity has a relation with the corrosion of underground buried structures as a water pipeline, gas pipeline and power cable casing. And it's a main factor in the cathodic protection and earth design. This paper presents soil resistivity maps each depth through measuring the soil resistivity in Kwachon, Kyonggi province. Also examines the soil resistivity characteristics on a change of temperature, moisture content and ion content in the laboratory.

  • PDF

파괴수명예측을 통한 지중배전용 전력케이블의 열화 진단 (Aging Diagnosis of Underground Distribution Power Cables Using Breakdown Lifetime Prediction)

  • 김충배;이정빈;임장섭;장영학;이진;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.222-225
    • /
    • 1999
  • Degradation diagnosis of XLPE insulated URD cables was accomplished through out new method. which was to be analyzed non-electrical experiments and synthesized by degradation points. To supplement this method, it was also carried out using several electrical analyses. Breakdown voltages were measured and breakdown lifetimes were Predicted appling for Weibull distribution function. As a result, breakdown lifetime in failure cables was shorted up to 1/3 times than that in general cables. It was very available to estimate cable degradation using above method, but it needs further study on XLPE insulated URD cables in order to improve reliability.

  • PDF

지중송전 장조장 케이블 운반 및 포설공법개발 (A method of underground transmission line power cable transport & pulling Installation For long distance span)

  • 오장만;배주호;방항권;민병욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.663-664
    • /
    • 2007
  • 지중송전선로 건설공사에 154kV 장조장 케이블 드럼개발 및 트레일러 일체형 Under Roller 방식을 이용한 포설장비를 개발하여 현장에 적용함으로써 신기술 신개발 공법 적용으로 인한 국제경쟁력 향상 뿐만 아니라 접속경간의 장조장 설계로 케이블 접속개소 감소로 인한 공사비절감과 공사기간 단축에 크게 기여하였다. 이와 동시에 공사를 위한 도로점용 단축으로 민원발생을 크게 감소시켰다. 현행 도로법 규제로 케이블의 운반중량이 제한되었던 케이블 표준 경간을 450m에서 최대 700m까지 가능하여 접속개소의 유연성이 확보되었을 뿐만 아니라 토목구조물(전력구,관로등)공사의 다양한 설계방법을 적용할 수 있게 되었다.

  • PDF

지중배전케이블의 PD 검출용 필터 시험 연구 (Filter Test for Partial Discharge Detection of Underground Distribution Cables)

  • 이용성;김정윤;이관우;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.215-216
    • /
    • 2005
  • To decrease and remove of much noises that is detected in PD (partial discharge) measuring test. we forced on detection of those. We made W-LC filter for measuring PD. which adapted that to field test. We tested after design laboratory circumstances like field line. and then the phase change properties of detected signal in UHF sensor were measured by Lemke Probe and oscilloscope (TDS-3054. Tektronix). Eventually we checked decrement of noises from experimental result. Also from experimental result at the joint box of 22.9[kV] distribution line. we obtained reasonable data which enable noises to decrease. Hereafter those results will be adapted at ultra-high voltage for trouble prevention and on-line cable watch. diagnosis of those.

  • PDF

아세틸렌블랙 함량에 따른 반도전 재료의 체적저항과 열전도 특성 (Volume Resistivity and Thermal conductivity of Semiconducting Materials by Acetylene Black)

  • 양종석;이경용;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.134-135
    • /
    • 2005
  • To improve mean-life and reliability of power cable, we have investigated volume resistivity and thermal conductivity showed by changing the content of acetylene black which is the component parts of semiconductive shield in underground power transmission cable. The sheets were primarily kneaded in their pellet form material samples for 5 minutes on rollers ranging between 70[$^{\circ}C$] and 100[$^{\circ}C$]. Then they were produced as sheets after pressing for 20 minutes at 180[$^{\circ}C$] with a pressure of 200[kg/cm]. The content of conductive acetylene black was the variable, and their contents were 20, 30 and 40[wt%], respectively. Volume resistivity of specimens was measured by volume resistivity meter after 10 minutes in the preheated oven of both $25\pm1[^{\circ}C]$ and $90\pm1[^{\circ}C]$. Thermal conductivity was measured by Nano Flash Diffusivity. The measurement temperatures of thermal conductivity using Nano Flash Diffusivity were both 25[$^{\circ}C$] and 55[$^{\circ}C$]. From these experimental results, volume resistivity was high according to an increase of the content of acetylene black. And thermal conductivity was increased to an increase of the content of acetylene black. And thermal conductivity were increased by heating rate because volume of materials was expanded according to rise in temperature.

  • PDF