• Title/Summary/Keyword: underground parking

Search Result 199, Processing Time 0.03 seconds

A Study on the Functional Analysis of Parking Lot Expansion Technology using Technology-Tree (기술트리를 이용한 주차장 확대 기술의 기능분석에 관한 연구)

  • Youn, Bohyung;Choi, Jaewook;Park, Sungpyo;Kim, Taewan;Lee, Chansik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.3
    • /
    • pp.64-76
    • /
    • 2019
  • Aged apartments lack parking space and are suffering from severe parking difficulties due to the increase in the supply of private cars due to the economic improvement. Efficient remodeling technology is required as a way to solve the problem of a shortage of parking spaces, but there is a lack of establishing a technology for remodeling plans that can reflect the characteristics of various parks. This study was conducted to analyze the functions of the parking lot expansion technology using the technology tree and to derive the final technology through the function deployment. As a result of functional deployment of the plan to expand the parking lot, the fifth function was deployed and a total of 22 technologies were derived. Four types of technologies are categorized, four technologies for underground expansion, 12 technologies for underground and ground expansion, two technologies for ground expansion, and four technologies for ground-based expansion. As a result of the functional deployment of the main entrance plan, the fifth function was deployed and derived with 22 technologies. The total technologies were grouped into four categories, four technologies for direct underground entry, 11 technologies for indirect underground entry, three technologies for direct access to ground, and four technologies for indirect entry to ground. Through case verification, the detailed technologies applied to the semi-industrial complex of remodeling were identified and expert surveys and interviews were conducted to verify the adequacy of the technology tree.

A Research on the Reconstruction Project for the Main Gate Area of the U University Campus (대학 정문 진입부 재구성을 통한 캠퍼스 환경개선에 관한 연구 -경남 소재 U대학의 주차 및 복합시설 구성을 중심으로-)

  • Lee, Kwang-Hee
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.10 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • In order to solve the current shortage of parking spaces, and redesign the main gate area of the U University, the research investigated some cases of other schools located in Seoul which actively constructed multi-purpose building structures. Those schools are considered to be good samples showing their efforts to fulfill the needs of more parking spaces in their campuses, and to cover with the growing needs of multi-functioned facilities accommodating services of academic affairs, reading room spaces, and amenities. With the investigation, the research finded out the current trends of campus developments from the sample schools, such as underground parking facilities connected with multi-purpose buildings along the main arteries of campuses. Following the trends the research thoroughly examined the present conditions of our school and tried to make some possible alternatives for the facilities. Under the conditions, the research suggested 1)to construct underground parking lots accepting around 1,000 cars under the ivory tower square located in front of University Administration Building, 2)to develop a big-scaled open square at the university main gate, and 3)to build a multi-purpose structure along the main street of the campus, which included administration services, studying spaces, and some commercial facilities.

Improvement of Underground Parking Garages Lighting in Residential Areas (아파트의 지하주차장의 조명 운영개선)

  • Chang, Soo-Jung;Choi, An-Seop;Choi, Sung-Youl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.163-168
    • /
    • 2004
  • The improvement of perspectives on dark and limited underground space could be an important factor in successful underground space development. Current trend in the apartment underground parking lot requires not only quantitatively energy efficient design and operation, but also qualitative improvement of the space. For this, we need to consider two factors: Firstly, to understand the characteristics of the fluorescent lamp. Secondly, to improve the uniformity ratio of illuminance. In winter season, a way to keep the uniformity and a method not to lower the indoor illuminance level by cold ambient air. Therefore, a change in interval and arrangement of the lighting fixtures is required. Also, in their operation, current time-fixed control method needs to be changed into the control that method considers the use pattern.

  • PDF

Professional Engineer Yard: A study on Preventing Floor Surface Condensation in Consideration of Thermal Characteristic of Underground Parking lot in an apartment (기술사마당: 공동주택 지하주차장의 열적특성을 고려한 바닥 표면결로방지 방안에 관한 연구)

  • Seo, Yong-Won
    • Journal of the Korean Professional Engineers Association
    • /
    • v.44 no.4
    • /
    • pp.44-49
    • /
    • 2011
  • For the pleasant dwelling place, the most of apartments are designed with the increased green area ratio in ground space and the underground parking lot. However, the condensation in underground space has occasionally occurred due to the insufficient ventilation and insulation treatment. Despite reinforcement of the insulation treatment and mechanical ventilation for the preventing method of condensation. It seems difficult to expect preventing effects for the condensation without consideration of the thermal characteristic of structures. Furthermore, no fundamental measure has been established because maintenance work for these defects incurs a lot of costs and these defects could be occurred again. This study suggests a new method for preventing floor surface condensation through analyzing the reasons of condensation which occurred in the underground floor.

  • PDF

The Development of a Model for Selecting Method of Entry for Apartment in Remodeling an Underground Parking Lot (지하주차장 리모델링 공사시 주동진입방법 선정 모델 개발)

  • Song, Nak-Hyun;Jung, In-Su;Lee, Chan-Sik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.2
    • /
    • pp.65-74
    • /
    • 2009
  • It is expected that the number of apartment complexes in Korea that are over 20 years old will rapidly increase to more than 3,500,000. Consequently, the remodeling of these buildings is being revitalized throughout the country. Among the requirements for such remodeling, the expansion of parking lots has considerable weight. When enlarging a parking lot, the access route from an underground floor to the main building (i.e., the means of entry into the main building) determines the possibility of vertical enlargement for elevators, the size of the parking lot, the construction period, and construction expenses, etc. When enlarging an underground parking lot of an apartment complex, the access between the main building and the parking lot, as well as the inhabitants' requirements for entering the main building, are generally determined based on the designer's experience, rather than on the exact estimation of the peculiarity of the complex. In order to resolve such a problem, when enlarging an underground parking lot, a systematic and rational method is needed for selecting the means of entry into the main building. In this study, a selection model is derived for the method of selecting an access route into the main building when constructing an underground parking lot, in order to provide a reasonable decision-making process. A research method was investigated for determining the access route into the main building when enlarging a parking lot. On the basis of research carried out through in-depth interviews with experts, the characteristics for each means of entry into the main building were analyzed and the factors affecting the selection of the access route were deduced. The affecting factors selected were construction efficiency, convenience efficiency and economic efficiency. Weight values were then estimated for the selected affecting factors by applying the AHP method. Results showed that convenience efficiency, which gained the highest value, is the most important factor in selecting the means of entry into the main building. The most suitable means of entry into the main building was also suggested after estimating the applicability of the site by selecting complexes with remodeling possibility. This study will be applied as a reference for selecting the means of entry into the main building when constructing an underground parking lot particularly for older apartment complexes.

Improvement Plan for Artificial Ground Landscaping of Underground Parking Lot in Apartment Complex (공동주택단지 인공지반 식재환경 개선방안)

  • Kang, Myung Soo;Moon, Seog Gi;Kim, Nam Jung
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.5
    • /
    • pp.51-64
    • /
    • 2014
  • Most planting grounds have converted to the artificial ground of the upper part of underground parking lot in apartment complex recently by increasing utilization of underground parking area. This study has examined the composition of each ground and planting status. The study presents problems of planting plans in artificial ground landscaping in apartment complex. This study has conducted reference and field research. It has researched green space planning, planting characteristics and measures condition of soil depth in 3 regions surveyed. The results are listed below. First, hybrid ground has the highest percentage and natural soils has the lowest percentage in the composition of green space in apartment complex. Artificial green space is composed of a number of small-scale grounds. Second, The study has found that planting characteristics don't reflect soil properties. On the other hand, planting deep rooting big arbors has a high proportion in artificial Ground. Third, the study has figured out 98% of fit in minimum soil depth for growth. Fourth, planters and landscaping stones are constructed in case of small green space. On the other hand, mounding is constructed in case of large green space. However in case of mounding types it has low fit, so it needs to improve this problem.

Leakage Situation and Main Leakage Areas of Domestic Residential Building Underground Parking Lots (국내 공동주택 지하주차장의 누수 실태 및 주요 누수 부위 조사)

  • Lee, Jung-Hun;Song, Je-Young;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.496-503
    • /
    • 2016
  • This paper studies the leakage situation of domestic residential building underground parking lots and main leakage areas. 18 complexes were studied and the results showed that 80% of buildings with exterior waterproofing had no leakage, but all buildings with interior waterproofing had leakage. According to a survey among professionals, water leakage problems are considered to be severe in underground parking lots and a preventative measure is required by the government. By comparing the survey and the actual situation at hand, the results showed that the lowest floor slab, wall construction joints, and floor expansion joints were the most prone to leakage. Based on the results, further study to develop a design manual for the appropriate prevention of leakage is deemed necessary.

The Concentrations of TSp, PM10 and Heavy Metal at Underground parking Lots of Public Facilities in Taegu City (대구시 공중이용시설 지하주차장의 총부유먼지, 호흡성먼지 및 중금속 농도)

  • 이현주;정재열;이종영;송희봉;홍성철
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.2
    • /
    • pp.22-29
    • /
    • 2000
  • This study was performed to investigate the concentrations of TSP, PM10 and heavy metals(Pb, Cd,Hg, Ni, Zn) of underground parking lots in Taegu city. The samples were collected from 3 department stores and 1 central park in the winter and the summer, 1997. The samples of 3 department stores were divided into sale period and non-sale period in the winter and the summer. The concentrations of TSP and PM10 were 109.6±1.5㎍/㎥ and 93.3±1.5㎍/㎥. In TSP, the zinc was the highest level, 287.16±1.5ng/㎥ and the cadmium was the lowest, 2.4±2.1ng/㎥ and in PM10, the zinc was the highest level, 193.6±1.5ng/㎥ and the cadmium was the lowest, 0.6±3.9ng/㎥. The correlation coefficient between the concentration of TSP and PM10 was 0.982(p<0.05). The correlation coefficients of corresponding heavy metal in TSP and PM10 were 0.863 for lead, 0.617 for mercury, 0.890 for nickel and 0.850 for zinc(p<0.05). The concentrations of TSP, PM10 and cadmium of PM10 in the winter were higher than those of the summer. However, the concentration of Hg of PM10 in the summer was higher than that of the winter. The concentrations of TSP and PM10 in sale period was higher than those of non-sale period and the concentrations of heavy metal in TSP and PM10 were not significantly different between sale and non-sale period. The proportions of PM10 to TSP were above 60% in dust, lead, nickel, and zinc and less than 40% in cadmium and mercury. The concentrations of TSP, PM10 and heavy metal in the underground parking lots were comparatively lower than those of general atmosphere. However, this kind of research to PM10 in the underground parking lots must be continued because it is very important particulate matter that affects human beng's health.

  • PDF

A Study on Improvement of Evacuation Safety Evaluation for Performance Based Design in Underground Parking Lot (지하주차장 성능위주설계의 피난안전성 평가 개선에 관한 연구)

  • Song, Young-Joo;Kong, II-Chean;Kim, Hak-Jung
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.85-97
    • /
    • 2019
  • Today, building constructions are becoming larger, higher, deeper, and complex to improve quality of human life and meet various needs. As a result, new design space for non - typically standardized space has been created, and targets for performance-based design are also becoming increased. An evacuation safety evaluation of performance-based design should be compared with ASET and RSET estimation so that the value of RSET does not exceed the value of ASET. However, there is a problem that it is difficult to secure the safety with using the performance-based design evaluation method currently in use, especially in case of the underground parking lot, because it has wide compartment area and various routes for evacuation. Therefore, in order to overcome these problems, this paper first investigates the simulation setting method of the performance-based design that is currently in use, and then conducts two fire simulations and three evacuation simulations for underground parking lots each time, so performs the evacuation safety evaluationin total six cases of situations. Here this paper analyzes the problem with comparative evaluation research and suggests the better solution for improved evacuation safety evaluation of performance-based design.

Trace Element Analysis and Source Assessment of Parking Lot Dust in Large Shopping Mall (대형유통업소주차장의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Song, Hee-Bong;Ahn, Jeong-Eem;Jung, Yeoun-Wook;Yoon, Ho-Suk;Keum, Jong-Lok;Do, Hwa-Seok;Kim, Sun-Suk;Kim, Jong-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.168-176
    • /
    • 2012
  • A total of 48 dust samples were collected from large shopping mall parking lots in Daegu metropolitan city in March 2011. Samples were sieved through a 100 ${\mu}m$ mesh and the concentration of 14 elements have been determined using by ICP after acid extraction. Results showed that Ca, Fe, K, Mg, Mn, Na and V were affected by natural sources while Cd, Cr, Cu, Ni, Pb and Zn were affected by anthropogenic sources. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. Anthropogenic trace element concentrations of ground roof dust were higher than those of ground and underground indoor dust. A large percentage of trace elements came from natural sources rather than anthropogenic sources. The percentage composition of chemicals of ground roof dust were higher than those of ground and underground indoor dust. This study showed that investigated parking lots were rarely contaminated with hazardous heavy metals. The heavy metal pollution of ground roof were higher than those of ground and underground indoors. The correlation analysis among trace elements suggest that components in ground roof were more highly correlated than those in ground and underground indoor. Also anthropogenic trace element levels were well correlated with parking lot age and parking density.