• Title/Summary/Keyword: underground parking

Search Result 199, Processing Time 0.026 seconds

The Effect of the Artificial Ground on Building Thermal Environment (인공지반이 건물 열환경에 미치는 효과에 관한 연구)

  • Hwang, Hyo-Keun;Lim, Jong-Yeon;Ryu, Min-Kyung;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.170-175
    • /
    • 2009
  • Apartment housing block has been spreaded according to rapid economic development and urbanization in Korea. A parking lot is located at underground, artificial ground is inevitably created in apartment housing block. Artificial ground creates different thermal environment compared to natural ground, because the composition and coverage of artificial ground are diverse. In this study, the effect of the artificial ground on building thermal environment will be disscussed by simulation. Considering the result of simulation, surface albedo is more important for building energy performance. A purpose of this study is to examine how the characteristic of surface effect to thermal environment, and to develop design method for sustainable outdoor space.

  • PDF

A Study of Residents' Demand for External Space of Apartment Site (아파트 외부공간 실태와 조성기법)

  • 김한수
    • Journal of the Korean housing association
    • /
    • v.11 no.3
    • /
    • pp.87-98
    • /
    • 2000
  • This study derives problems of external space utilization site from on-site observation and questionnaire survey in order to suggest solutions for the problems. The main results are follows. First, fences as visual boundaries of apartment site play some negative roles - separation of space and heterogeneity of circumstance. This study suggests green fences to cure this problem. Second, residents want to change space use - ground to be used as green space or space for relaxation in stead of parking lots, elevator hall as social space, and underground as bike parks or health centers. Third, rooftop space, used as empty space or machine storage space, should be designed to be utilized as relaxation space by making easy to enter and exit.

  • PDF

Prediction and analysis of noise level of outdoor areas in roadside apartment complexes (도로변 아파트 단지 옥외공간의 소음도 예측 및 분석)

  • Shin, Hye-Kyung;Yang, Hong-Seok;Kim, Myung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.885-887
    • /
    • 2014
  • Outdoor spaces in an apartment complex have been enlarged by the increased underground car parking. It has become accepted as important place for acoustic comfort of resident. This paper attempts to determine the noise exposure to the outdoor area in 21 apartment complexes built within 5 years. The results showed that the average noise level of outdoor area ranged from 37.6dB(A) to 67.2dB(A). And the percentage of areas below the noise level of 55dB(A) range 0.1% to 95.0%. The analysis on correlations shows that the traffic volume and building coverage have significant effects on noise level.

  • PDF

A Study on the Development of Dual-band PLL Frequency Synthesizer for miniature Repeater (초소형 중계기용 듀얼 밴드 주파수합성기 개발에 관한 연구)

  • 나영수;김진섭;강용철;변상기;나극환
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.37-40
    • /
    • 2003
  • The 1.63㎓, 2.33㎓ dual-band PLL frequency synthesizer has been developed for applications to the miniature repeater. The miniature dual-band repeater will be used at shopping mall, basements and underground parking lots. The in-loop 1.63㎓, 2.33㎓ dual-band PLL frequency synthesizer has been developed by designing Si BJT VCO and PLL loop circuits with Colpitts. The prototype of 1.63㎓, 2.33㎓ dual-band PLL frequency synthesizer of size 19${\times}$19${\times}$8(mm) has shown operating frequencies of 1.63㎓, 2.33㎓ ranges, RF output of 1dBm(PCS), 1dBm(IMT-2000), phase noise of -100 dBc/Hz(PCS), -95dBc/Hz(IMT-2000) at 10KHz offset, harmonics suppression of -24dB c(PCS), -15dBc(IMT-2000).

  • PDF

Information Network Usage Plan for the Quality Control of Leakage Prevention (누수예방을 위한 품질확보 관련 정보공유시스템의 활용방안의 관한 연구)

  • Kang, Hyo-Jin;An, Ki-Won;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.217-218
    • /
    • 2017
  • Residential apartment underground structures are being utilized for many purposes such as parking lots, community centers, fitness centers, etc. for efficient use of space. However, there are increasing problems of leakage due to various environmental and deterioration conditions. This paper proposes the development of an information network system which can serve as a base to provide solutions, alternatives and technical information for leakage prevention and effective design at the beginning of the construction stage.

  • PDF

Deep Learning based Object Detector for Vehicle Recognition on Images Acquired with Fisheye Lens Cameras (어안렌즈 카메라로 획득한 영상에서 차량 인식을 위한 딥러닝 기반 객체 검출기)

  • Hieu, Tang Quang;Yeon, Sungho;Kim, Jaemin
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.2
    • /
    • pp.128-135
    • /
    • 2019
  • This paper presents a deep learning-based object detection method for recognizing vehicles in images acquired through cameras installed on ceiling of underground parking lot. First, we present an image enhancement method, which improves vehicle detection performance under dark lighting environment. Second, we present a new CNN-based multiscale classifiers for detecting vehicles in images acquired through cameras with fisheye lens. Experiments show that the presented vehicle detector has better performance than the conventional ones.

Development of Accident Scenarios for Hydrogen Refueling Station and Fuel Cell Vehicle (수소충전소 및 수소자동차의 사고 시나리오 개발)

  • Byoungjik Park;Yangkyun Kim;Ohk Kun Lim
    • Journal of Auto-vehicle Safety Association
    • /
    • v.15 no.1
    • /
    • pp.27-34
    • /
    • 2023
  • The registration rate of eco-friendly vehicles, such as hydrogen vehicles, is increasing rapidly, however, few first responders have experienced related accidents. Accident scenarios at hydrogen refueling stations and hydrogen vehicles on a road were investigated, and the relative importance of each scenario was analyzed using AHP analysis. Leakage, jet flame, and explosion that occurred inside and outside the hydrogen refueling station were reviewed, and the hydrogen gas explosion in the compartment showed the highest importance value. In case of the hydrogen vehicle, traffic accident statistics and actual accidents were used. It was analyzed that the hydrogen vessel explosion on the road due to the failure of TPRD and the leakage in the underground parking area were difficult to respond. The developed accident scenarios are expected to be used for first responder training.

Extracting Foundation Input Motion Considering Soil-Subterranean Level Kinematic Interaction (지하층-지반 운동학적 상호작용을 고려한 기초저면의 설계지반운동 산정)

  • Sadiq, Shamsher;Yoon, Jinam;Kim, Juhyong;Park, Duhee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.11
    • /
    • pp.31-37
    • /
    • 2018
  • Most of tall building systems are composed of above-ground structure and underground structure used for parking and stores. The underground structure may have a pronounced influence on tall building response, but its influence is still not well understood. In a widely referred report on seismic design of tall buildings, it is recommended to model the underground structure ignoring the surrounding ground and to impose input ground motion calculated considering the underground structure-soil kinematic interaction between at its base. In this study, dynamic analyses are performed on 1B and 5B basements. The motions at the base are calculated to free field responses. The motions are further compared to two procedures outlined in the report to account for the kinematic interaction. It is shown that one of the procedure fits well for the 1B model, whereas both procedures provide poor fit with 5B model analysis result.

Multi-directional DRSS Technique for Indoor Vehicle Navigation (실내 차량 내비게이션을 위한 다방향 DRSS 기술)

  • Kim, Seon;Park, Pangun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.6
    • /
    • pp.936-942
    • /
    • 2022
  • While indoor vehicle navigation is an essential component in large-scale parking garages of major cities, technical limitations and challenging propagation environments considerably degrade the accuracy of existing localization techniques. This paper proposes a proximity detection scheme using low-cost beacons where a handheld mobile device within a moving vehicle autonomously detects its approximate position and moving direction by only observing Received Signal Strength (RSS) values of beacon signals. The proposed approach essentially exploits the differential RSS technique of multi-directional beams to reduce the impact of the environment, vehicle, and mobile device. A low-cost multi-directional beacon prototype is developed using Bluetooth technology. The localization performance is evaluated using 96 beacons in an underground parking garage within an area of 394.8m×304.3m. Experimental results show that the 90th percentile of the average proximity detection error is 0.8m. Furthermore, our proposed scheme provides robust proximity detection performance with various vehicles and mobile devices.

DEVELOPMENT OF BUILDING INFORMATION MODEL FOR RESOURCES OPTIMIZATION IN CONSTRUCTION PROJECT

  • Gopal M. Naik;Rokhsareh Badamahgan
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.634-639
    • /
    • 2013
  • The aim of the study is to develop the 3D visualization of Building Information Model and integrated 4D model for optimization of resources in the construction project. This study discuss the process of methodology and creation of 4D model of the project and simulate it to monitor the workflow at the site. Different stages of the construction process and activities are generated by using Revit and MS Project. MS project has been used for creation of the schedules and these are linked with the Revit for 3D modeling. The time used as the fourth dimension and 4D model created by using Navisworks Time liner software. Narges shopping center is presented as a case study to realize the actual uses and benefits of Building Information Model (BIM). Narges shopping mall is located in Tehran, Iran. As a part of Hekmat master plan, Narges shopping center is an 11 stores building with a total area of 30000 Sq.m. This shopping and entertainment center is comprised of 150 retails and two multi-use public halls with a capacity of 400 persons each and underground parking with total 400 parking space. The main purpose of architecture was to create an urban public center along with its revolving, spiral like form and an ever changing continuous façade by means of different colors, materials, which is in harmony with the other building of the master plan. The approximate cost of the project is $17 million and duration of the project schedule is 30 months. The developed Building Information Model enabled us to identify the potential collisions or clashes between various structural and architectural systems. 4D model has been used for limiting the interaction between subcontractors installing the different systems so rework could be avoided and productivity maximized. It is also observed that the utility of BIM for construction stimulation and clash detection is the best suitable method. Clash detection before the implementation of work is highly recommended to avoid rework.

  • PDF