• Title/Summary/Keyword: underground facilities

Search Result 645, Processing Time 0.034 seconds

A Study on the Quality Assurance of National Basemap Digital Mapping Database (국가기본도 수치지도제작 데이터베이스의 품질 확보에 관한 연구)

  • 이현직;최석근;신동빈;박경열
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.1
    • /
    • pp.117-129
    • /
    • 1997
  • In recent years, the 1 : 5,000 scale Digital National Basemap(DNB) has been generated under National Geo-graphic Information System(NGIS) Project. The DNB database generated will be the backdrop data for thematic maps, underground facilities maps and so on. The DNB database will be distributed to the government and private sectors in near future so that it should meet the requirements as the basic data. In order to assure the quality of DNB database, the establishment of quality assurance process to database was in great need. In this study, we were mainly concerned with improving the quality of digital national basemap database in geomatric aspect as well as the processing time due to the amount of digital data generated. As a results of this study, the quality assuance process of DNB database is established and automatic quality assurance program is developed. Also, the program developed in this study is contributed to quality assurance of DNB database as well as economic aspects.

  • PDF

Performance Test of Corner Rigid Joint for Modular Structure using Channel and Coupler (채널과 커플러를 사용한 모듈식 구조체 우각부 연결구조의 성능검증 실험)

  • Lee, Jun-Kyoung;Lee, Jong-Soon;Lee, Sung-Hyung;Kim, Hee-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2255-2262
    • /
    • 2015
  • Recent study about near-surface is proposed to overcome non-economic of underground railway and to reduce people's complaints of ground elevated railway. In this report, precast modular structure system replacing temporary facilities is applied to ensure the construction ability and economic feasibility. To verify the performance of connection joint between permanent structural wall and upper slab, loading test is carried out. As a result of the test, wall replacing temporary structure to slab connection is possible to transfer bending moment. By 30% increase of bending resistant performance for connection joint using coupler, coupler connection joint is more advantageous to resist bending moment compared to channel connection.

Evaluations of Dangerous Voltages around Grounding Electrode using Small-sized Model (축소모델을 이용한 접지전극 주변의 위험전압 평가)

  • Baek, Young-Hwan;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.83-88
    • /
    • 2010
  • In this paper, to propose a valid method solving a problem relevant to grounding from actual field data, the experimental results relevant to touch and step voltages and surface potential profiles measured around the real-sized and small-sized grounding electrode models were described. The ground surface potential profiles and dangerous voltages around the concrete pedestals employed in street facilities such as street lamps, traffic signal lamp and controllers as a case study were measured and discussed. The hemispherical cell with a diameter of 1,160[mm] was employed to simulate uniform soil. As a result, the results measured with the small-sized model were in reasonably agreement with the data obtained from the real-sized installation. It was found that the small-sized model test could be employed as a useful means evaluating the dangerous voltages around grounding electrodes installed at the inaccessible areas such as mountains, underground, underwater, and so on.

A Study on the Pollution Sources of Simple water Supply Piped System using Statistical Analysis (통계적 분석을 이용한 간이급수시설의 오염원에 관한 연구)

  • 이홍근;김현용;백도현;김지영;이태호
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.2
    • /
    • pp.56-67
    • /
    • 1999
  • This study was performed to suggest the basic data and plans for the establishment of safe water supply plans in simple water supply piped system in the rural areas. In 4 different places, 24 points of water sources 36 points of taps from water sources were sampled. Of the whole 60 points, 55 points were ground water and 5 points were surface water. 14 items were measured for the analysis of water quality on each samples. The measured items were analyzed again by statistical method ; cluster analysis and principle components analysis. The results of this study are as followed. 1) In water quality analysis on water sources, 4 items, bacteria, E.coli, NH3-N and Fe exceed the standard. Of 24 points, 20 points(83%) on bacteria, 1 point(4%) on NH3-N and Fe exceed the standard. 2) In water quality analysis on near and remote taps, 4 items, bacteria, E.coli, NH3-N and Fe , exceed the standard. Of 36 points, 20 points (81%) on bactria, 1 pint(3%) on NH3-N and Fe exceed the standard. 3)Cluster analysis on water quality shows the differences by the kinds of water sources, geographical characteristics and distance from water sources. 4) Principle components analysis on ground water shows that Factor 1 and Factor 3 are natural fluctuation by the content of soil. Also, Factor 2 and Factor 4 are penetration of pollutants to underground. Therefore, it is needed to take deeper ground water in order to prevent from pollution in the areas which have ground water as water source . 5) Principle components analysis on surface water shows that Factor 1 is penetration of vacteria from surface to water source when rainfalls. Also, Factor 2 is fluctuation of water quality by the geographical characteristics. Therefore, the counterplans against non-point pollution source must be taken. Filtration and disinfection facilities are needed in the areas which have surface water as water source.

  • PDF

A Study on utilization of 3-Dimension GIS for Disaster Prevention on Urban Safety and Disaster Paradigm (도시안전패러다임을 고려한 방재분야 3차원 공간정보 활용방안 연구)

  • Park, Young-Jin;Yeon, Kyung-Hwan
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2008.10a
    • /
    • pp.136-141
    • /
    • 2008
  • The rapid development of the information technology has passed over the implementation of the virtual reality. It is realizing information services that are form of the globalization, based on the Internet. In addition, the effort to apply IT to public administration for public services has been made. The remarkable development of computer hardware has overcome the limit of the information distribution and emerged for practical use in various fields such as public institution, underground facilities management, tourism industry development etc. However, the practical use of Virtual Reality with Three-Dimensional GIS on disaster management by Korea National Emergency Management Agency is very much low. Therefore, this studies focus on how to use 3-Dimensional GIS for the purpose of fire disaster prevention. The studies also discussed, through understanding of the limitations of 2-Dimensional GIS, the establishment of basis for fire prevention technology development and its utilization among those ubiquitous city paradigms, which have become so much issues these days.

  • PDF

A Study on Behavior Characteristics of Volatile Organic Compound Caused by Ventilation in a Room (통풍에 의한 휘발성 유기화합물의 실내 거동 특성에 대한 연구)

  • Kim, Jang-Woo;Chung, Jin-Do
    • Journal of Environmental Science International
    • /
    • v.15 no.11
    • /
    • pp.1011-1016
    • /
    • 2006
  • Recently, volatile organic compound(VOC) has been noted as a main cause of air pollution. VOC, with its toxic and offensive odor, is hazardous to health. Furthermore indoor, underground and hish-rise buildings are preferable living spaces. People spend more than 80% of the day indoor, so indoor air pollution is a matter of importance. In Korea, from 2004, 10 types of indoor pollutants in public facilities have been identified. However, there is no standard for individual VOC, so the regulation has not yet effectively been carried out. In this study, we have studied on the diffusion of Benzene in a room using a numerical analysis for various air-controlled conditions consisted of door, window and ventilation system. This study investigates spatial concentration distribution and time-history of room-averaged benzene concentration for several cases. The results of this study show that when the room is ventilated by a small fan only for 30 minutes, the average concentration of benzene is decreased a very little, thus the impact to human body would be serious compared to the case of natural ventilation by window and door, In the case of natural ventilation by window and door, if the wind speed is higher than 0.5m/s, it takes small than 4 minutes for benzene to spread to the target concentration of $1.2mg/m^3$.

Development of Underground Conduits Eco-Monitoring System (지하공간 환경 모니터링 시스템 개발 및 시험)

  • Park, Jungl-Kwon;Han, Jin-Woo;Kang, Wang-Kyu;Woo, Byong-Soo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.40-44
    • /
    • 2009
  • 지하구는 도시의 신경망이라 할 수 있는 통신, 전력, 상수도, 난방, 쓰레기 처리시설 등 도시 운용/관리를 위한 주요시설물을 안전하게 수용하고, 유지 관리하기 위한 시설로 IT기술을 이용하여 수용된 시설을 효과적으로 유지/관리하고, 재난으로부터 안전하게 보호함과 동시에 최소의 비용과 에너지로 수용된 시설물을 유지관리하기 위한 연구가 많이 진행되고 있다. 따라서 본 논문에서는 지하구(공동구, 통신구, 전력구)의 운용 및 유지관리와 지하구에서 발생될 수 있는 각종 재난에 대응하기 위한 지하구 운용 및 유지관리에 대해 알아보고, 지하구 내부에 수용된 시설물을 효과적으로 유지관리하고 재난에 신속히 대응하기 위한 지하구 환경모니터링 시스템에 대해 기술 하고자 한다. 지하구 환경모니터링 시스템은 지하구 내부에는 전력, 상수도, 통신, 난방 등 다양한 시설물이 수용되어 있으며, 이러한 시설물의 부식, 고장 등으로부터 보호하기 위해 지하구내부의 환기시스템의 송풍기와 지하수와 기상재해로 인한 지하구 및 수용시설물의 침수를 막기 위한 양수펌프에 대해 실시간 상태모니터링 통해 송풍기 및 펌프의 고장여부를 판단하여 관리자에게 알림으로써 관리자가 신속하게 대응 할 수 있도록 하였다. 송풍기의 제어는 지하의 내부와 외부에 설치된 온/습도 센서를 통해 지하구 내부환경을 최적으로 유지할 수 있도록 함으로써 쾌적한 지하 내부환경 유지하고, 급/배기가 필요할 경우에만 송풍기를 가동함으로써 에너지를 절약 할 수 있으며, 화재, 침수 등에 대한 재난시 환풍기의 급/배기, 정지 등을 신속하게 제어할 수 있도록 하였다. 또한 지하구내부에서 발생된 재난을 유/무선을 이용하여 신속하게 지하구 주변의 장치(U-Pole 또는 통합컨트롤러)를 통해 경보를 전파함으로써 주변 시민들이 안전하게 대피할 수 있도록 하였다. 그리고 지하구 환경모니터링 시스템을 검증하기 위해 실제 지하구 및 실험실에 시스템 및 Test Board을 설치하여 운용시험을 실시 하였다.

  • PDF

A Study of Subspacing Strategy for Service Applications in Indoor Space (실내공간 응용 서비스를 위한 공간분할 방법에 관한 연구)

  • Kang, Hye Young;Jung, Hyo-jin;Lee, Jiyeong
    • Spatial Information Research
    • /
    • v.23 no.3
    • /
    • pp.113-122
    • /
    • 2015
  • Recently, according to developing advanced construction technologies, buildings has been enlarged such as high-rise buildings or complex buildings associated with underground facilities. The number of indoor activity population has increased very quickly. Because of that, technical requirements for Indoor location based service (Indoor LBS) also have been increased. Although indoor networks have to be constructed for efficient LBSs in indoor space based on OGC IndoorGML, it is not suitable for large and complex space to apply the simple network structure to constructing indoor navigation networks. The indoor navigation network has to be constructed according to logical, physical, and functional constraints for indoor space. In order to do that, subspacing methods are required to partition large and complex indoor space into proper size of subspace. In this paper, we proposed the basic requirements of subspacing in indoor space for creating efficient indoor network, as well the work process of subspacing in indoor space.

A Basic Study on Vehicle Load Analyzing System for Embedded Road (임베디드 도로를 위한 차량하중 분석시스템 기초연구)

  • Jo, Byung-Wan;Yoon, Kwang-Won;Park, Jung-Hoon;Kim, Heoun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1D
    • /
    • pp.127-132
    • /
    • 2011
  • Load managing method on road became necessary since overloaded vehicles occur damage on road facilities and existing systems for preventing this damage still show many problems. Accordingly, efficient managing system for preventing overloaded vehicles could be organized by using the road itself as a scale by applying genetic algorithm to analyze the load and the drive information of vehicles. First of all, accurate analysis of load using the behavior of road itself is needed for solving illegal axle manipulation problems of overloaded vehicles and for installing intelligent embedded load analyzing system. Accordingly in this study, to use the behavior of road, the transformation was measured by installing underground box type indoor model and indoor experiment was held using genetic algorithm and 10% error were checked.

A Study on Performance-based Evaluation Method for Rock Slopes : Deduction of Evaluation Factors (암반비탈면의 성능기반 평가기법 연구 : 평가항목 도출)

  • Lee, Jong-Gun;Suk, Jae-Wook;Kim, Hong-Kyoon;Kim, Yong-Soo;Moon, Joon-Shik
    • Tunnel and Underground Space
    • /
    • v.25 no.1
    • /
    • pp.86-96
    • /
    • 2015
  • In this study, the performance-based evaluation factors for rock slopes have been deducted using Delphi-method. Validity of the result was verified through factor analysis. Performance of rock slope is classified as soundness, stability and durability. Through the Delphi survey, 17 factors including discontinuity orientation are deducted for soundness, 4 factors and 3 factors are selected for stability and durability, respectively. Validation is conducted using Exploratory Factor Analysis (EFA) for 24 factors, and all factors are found to be valid. As a result of Exploratory Factor Analysis (EFA), 3-types of performance were subdivided into internal soundness, external soundness, risk, damage and durability of slopes and protection (reinforcement) facilities.