• Title/Summary/Keyword: underground facilities

Search Result 645, Processing Time 0.04 seconds

Prevention of Soil Contamination from Underground Storage Facilities (유류저장시설로 인한 토양오염 예방대책)

  • 배우근;홍종철;정진욱;강우재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.169-173
    • /
    • 1998
  • The practice of the construction and management of the underground petroleum storage facilities in Korea was investigated extensively, and the problems were identified. The advanced technologies in the U.S.A was comparatively studied. Considering the effectiveness of leak prevention and technology applicability, the following measures were suggested. To prevent corrosion of the tank, a clad tank, an interior-lining tank, or a double-wall tank was appropriate and appeared to be most cost effective. For piping, non-metalic material was suggested. To prevent spill, a catchment basin can be effective. For monitoring of leak, construction of more than one of one or combination of an automatic leak-detection device, a vapor-detection system, a ground water-monitoring system, and a double-wall detection system was recommended.

  • PDF

A Study on the Indoor Air Quality of Public Entertainment Facilities. (공공위락 시설의 실내 공기환경에 관한 연구)

  • 정재국
    • Journal of the Korean housing association
    • /
    • v.9 no.1
    • /
    • pp.143-152
    • /
    • 1998
  • This study aims to suggest ventilation design data for Public Entertainment Facilities in relation to Indoor Air Quality. The concentration of indoor air pollution such as CO, CO2, RH, Radon, HCHO, TSP was investigate, and the reguired ventilation rate of Public Rooms was calculated. As resuits of this study, the following conclusion could be obtained. Field measurement of P.E.F reveals that the concentration of CO2 was mist polluted and higher than IAQ standard, while that of other pollutats did not exceed the standard. In underground the concentration of CO2 increased 1130ppm(2 persons) 2170ppm(4 persons) 1970ppm(6 persons). The CO2 pollution was serions problem in underground more than second floor, in only exhaust ventilation system more than exhaust and supply system.

  • PDF

Investigation for Earth Resistance and Leakage Current of D/L (배전선로 접지저항 및 누설전류 실태조사)

  • Lee, H.G.;Ha, T.H.;Bae, J.H.;Ha, Y.C.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.379-381
    • /
    • 2003
  • The sharing of common corridors by electric power transmission lines and pipelines is becoming more common place. However, such corridor sharing can result in undesired coupling of electromagnetic energy from the power lines to the near facilities. This causes induced voltages on underground metallic pipelines due to the power line currents. This could cause AC corrosion in the pipeline, which could in turn lead to disastrous accidents, such as gas explosion or oil leakage. This paper investigates for the limitation of induced voltage on the buried metal structures which is used in the inside and outside of the country. And then we measure the earth resistance and leakage current of 22.9kV distribution lines and pipe to soil potential of near pipelines in Seoul Korea. Hereby we can see the leakage current flowing through the earthing electrode have an effect on near pipelines.

  • PDF

A Study on Quality Level of Underground Spacial Information for Accuracy Improvement (지하공간정보 정확도 향상을 위한 품질등급제 연구)

  • Kim, Wondae;Lee, Kang Won;Kim, Tae Hoon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.3
    • /
    • pp.167-177
    • /
    • 2021
  • Facilities located in the underground space are closely related to the sanitation and safety of the city, and the underground spatial information is precisely constructed and used as important information for facility maintenance, safety, and underground space development. In this study, a method was studied to increase the field usability by increasing the reliability of underground spatial information constructed in Korea and used in the field. For this study, the current status of the construction of underground spatial information in Korea was summarized, and cases of the underground spatial information quality grading system applied in the US, UK, Canada, France, and Australia, which are advanced geospatial information countries, were investigated. In terms of field usability, a questionnaire was conducted on the systems, standards, and management methods related to underground spatial information of field experts and consumers working in related fields in Korea, and statistical analysis was conducted to analyze the relevance of the introduction. Through this study, it was concluded that it is necessary to introduce a quality grading system according to the construction method of underground spatial information, accuracy and reliability, and to improve related systems and regulations.

Deformation Behaviors of Temporary Tieback Wall during Excavation Works (현장계측과 수치해석을 이용한 가설 흙막이 구조물의 변형특성 연구)

  • 김종우
    • Tunnel and Underground Space
    • /
    • v.5 no.3
    • /
    • pp.223-229
    • /
    • 1995
  • During excavation works for underground facilities, temporary tieback wall with earth anchor system was investigated for safety's sake. An excavation 9.7 meter deep was monitored by slope inclinometer in twelve measuring points. Instrumented lateral displacements of the wall during 177 days are represented. Especially, lateral displacements of the two positions under completely different condition are compared to investigate the effect of backfilling between soldier pile and the soil behind wall. The deformation behaviors of the wall according to both depth and elasped time are discussed. Finally, a numerical analysis by the program FLAC was performed, and calculated displacements are compared to measured ones.

  • PDF

Performance Improvement of High Performance Shrinkage Reducing Agent using Early Strength Improving Agent (조기강도 개선제를 활용한 고성능 수축저감제의 성능 개선)

  • Park, Jong-Pil;Jung, Yong-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.296-302
    • /
    • 2016
  • Studies aimed at reducing the occurrence of cracks by the shrinkage of concrete are in demand because the repair and reinforcement for cracks caused by declining concrete durability costs the user to maintain the concrete structure. In particular, in underground power facilities for power transmission, the cost is a heavy burden to repair and reinforce. For this reason, underground power facilities demanded effective methods for crack reduction at the engineering design step. This study, as a part of the development of shrinkage reducing agent for low shrinkage concrete on underground power facilities, investigated TEA to complement the shrinkage reducing agent to improve the early strength of concrete. In the case of TEA 3% as a shrinkage reducing agent, the early strength was improved significantly, and the shrinkage reducing effect was excellent. In addition, TEA 3.0 % and the shrinkage reducing agent 2.0 % showed excellent shrinkage property and compressive strength. On the other hand, more study of shrinkage reducing materials, including performance reviews on the shrinkage reducing materials with variable factors and type of materials, will be needed to generalize these results.

A Study on the Application of Adsorption Function in Metal Filter for the Removal of VOCs in Underground Facilities (지하시설 VOCs 제거를 위한 메탈 필터의 흡착기능부여 연구)

  • Jang, Younghee;Lee, Sang Moon;Yang, Heejae;Kim, Sung Su
    • Applied Chemistry for Engineering
    • /
    • v.30 no.5
    • /
    • pp.633-638
    • /
    • 2019
  • Indoor air quality underground facilities are not equipped for the removal of volatile organic compounds (VOCs) and they are usually treated by diffusion methods such as ventilation. In this study, an adsorption filter was prepared using various coating methods such as carbon nano fiber (CNF) and dip coating. As a result, the adsorption performance was improved by 2 to 20 times or more compared to that of using the metal foam support. This is maybe due to the enhancement of pore distribution which was confirmed by SEM. In addition, the adsorption performance was 13.95 mg/g by adding lignin, and also an average adsorption performance of 13.25 mg/g was maintained after washing indicating that a highly durable adsorption filter material was prepared. It can be suggested that the developed adsorption filter material can be a potential solution that can fundamentally control VOCs, not via the concentration reduction of mechanical ventilation in underground facilities.