• Title/Summary/Keyword: underground facilities

Search Result 645, Processing Time 0.033 seconds

A Study on Planning and Geometric Design of Underground Roads (지하도로 계획 및 기하구조 설계에 관한 연구)

  • Kim, Nakseok;Bae, Seongsik
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.1
    • /
    • pp.1-11
    • /
    • 2011
  • Plans of underground roads have been established, and the possibilities of underground road constructions have been growing in Korea. However, the study on characteristics of underground roads, the enactment of law, and the establishment of design criteria haven't been conducted so far, if any. Based on these backgrounds, the paper presents the basic direction on the construction method of underground roads. It also investigates the needs and characteristics of underground roads and reviews domestic and foreign examples. Major results by implementing the research are as follows: 1) when selecting the route of underground roads, the use of underground space, technical aspects, and traffic systems should be comprehensively considered; 2) the design speed of underground roads will be 10km/h above the speed limit to secure safety; 3) disaster prevention facilities should be planned to connect high traffic management system for coping with unexpected situations. Although this study has a limitation that hasn't reflected the driver's characteristics on new spaces such as underground roads, it has some significance that it suggests the major reviewing issues on the construction of underground roads, and presents the direction through the previous study.

Evaluation of the Interruption Cost of Distribution Power Systems Considering the Failure Source and the Composite Customer Interruption Cost

  • Park, Sang-Bong;Nam, Kee-Young;Kim, Dae-Kyeong;Jeong, Seong-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.3
    • /
    • pp.124-129
    • /
    • 2003
  • As the power industry moves towards open competition, there has been a call for methodology to evaluate power system reliability by using composite interruption cost. This paper presents algorithms to evaluate the interruption cost of distribution power systems by taking into consideration the failure source and the composite customer interruption cost. From the consumer's standpoint, the composite customer interruption cost is considered as the most valuable index to estimate the reliability of a power distribution system. This paper presents new algorithms that take into account the load by customer type and failure probability by distribution facilities while calculating the amount of unserved energy by customer type. Finally, evaluation results of unserved energy and system interruption cost based on composite customer interruption cost are shown in detail.

Suitability valuation of Underground Facility Construction Using GIS (GIS를 활용한 지하시설물 시공의 적정성 평가)

  • 김감래;이재기;임건혁
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.465-469
    • /
    • 2004
  • The purpose of this study is to evaluate suitability of Underground Facility Construction in great land development area. Because there are the construct of national integration information control system and the advance of information technique, the necessity that construct the UIS to manage the urban space systematically is enlarged. In the purpose that we prepare the base of underground facility management system by driving the step digitalizing facilities buried underground and protect urban safety accident, we introduce the GIS in land development area. This study proposes the improvement direction by examining the outcome through the driving method and the outcome analysis.

  • PDF

Investigation of Ground Environment Around Underground Oil Storage Facilities Using the Envi-Cone Penetrometer System (환경콘에 의한 지하유류 저장시설주변 지반환경 조사)

  • 정하익;홍승서;김영진;홍성완;곽무영
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.273-280
    • /
    • 2000
  • In recent years there has been a steady increase in geoenvironmental engineering projects where geotechnical engineering has been combined with environmental concerns. Many of these projects involve some investigation of contaminant in the ground. There are many techniques such as geophysical, drilling, sampling, md pushing techniques for investigation of contaminated ground. The most rapidly developing site characterization techniques for geoenvironmental purposes involve direct push technology, that is, penetration tests. The purpose of this study investigated underground oil storage tanks(USTs) using the envi-cone penetrometer system. The electrical resistivity sensor, pH sensor, ORP sensor, and thermometer are installed in envi-cone penetrometer system. This envi-cone penetrometer system provides a continuous profile of measurements, and it is rapid, repeatable, reliable and cost effective for investigation of contaminated ground surrounding the underground oil storage tanks.

  • PDF

Study on the Air Quality of Metropolitan Subway Stations (수도권 지하철 지하역사의 실내공기질 연구)

  • Cho Young-Min;Park Duckshin;Park Byung-Hyun;Park Eun-Young
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.77-82
    • /
    • 2005
  • Recently, people's rising interests toward a 'well-being' lifestyle together with research contributions are accelerating the concerns regarding indoor air pollution making indoor air quality management an emerging environmental challenge of the era. The Ministry of Environment began to regulate the air quality of railway stations last year. The newly established 'Indoor Air Quality Act' covers 17 facilities whereas only underground subway stations and underground markets were regulated by previous 'Underground Air Quality Management Act' of 1996. In this study, we carried out the measurement of temperature, relative humidity, CO(carbon monooxide), $CO_2$(carbon dioxide), HCHO(formaldehyde), PM-10(particulate matters), and VOCs(volatile organic compounds) in underground subway stations. Based on the obtained results, we will suggest a way to improve the indoor air quality of the subway stations.

  • PDF

The Evaluation of CO Concentration Level at Underground Space in Busan Metropolitan City (부산광역시 지하공간의 CO 대기질 평가)

  • 이화운;박종길;장난심;이희령;김희만
    • Journal of Environmental Science International
    • /
    • v.12 no.1
    • /
    • pp.35-40
    • /
    • 2003
  • With increasing population densities in cities, underground facilities and entertainment locations are proliferating at a rapid pace in efforts to maximize the use of land. The purpose of this study is to evaluate CO concentration level of subway stations having underground platforms in Busan Metropolitan City, from September to November 2000, over seven times. The places of inquiry include Yonsan-dong station, Somyon station, Busan station, Nampo-dong station and Dusil station. The samplings were conducted at three points of each station, i.e. gates, ticket gates, and platforms. The component of CO concentration is the main elements of indoor air quality evaluation. The total concentrations and average concentrations of CO were the higher at the Somyon station. The distribution of CO concentrations at each station, generally was higher at gate than ticket gates and platforms. The I/O ratios(I-platforms, 0-gates) were expressed highly than 1 at the Yonsan-dong station, Busan station, Nampo-dong station and were lower than 1 at the others.

Application Method of Integrated Information System on waterproofing Quality for Improving Structure Durability (구조물 내구성 향상을 위한 방수품질 관련 통합정보시스템 활용방안에 관한 연구)

  • Kang, Hyo-Jin;An, Ki-Won;Kim, Byoung-il;Oh, Sang-keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.339-340
    • /
    • 2018
  • Contemporary concrete structures make use of underground spaces as parking lots and other comfort facilities for efficiency purposes. As underground environmental conditions are in constant exposure to degradation factors from the environment such as groundwater, hydraulic and soil pressure, structural movement and settlement, structural defects in the form of leakage occur. Current maintenance regulations and regimes are unable to respond to this field, as degradation mechanisms in underground environments are still unclear. In this regard, this study proposes the utilization of integrated information sharing system that can provide various technical information for construction designs to prevent leakages in underground concrete structures.

  • PDF

A preliminary study of Standardization Plan on Underground Air filtration Facility (지하역사 공기여과장치 표준화방안 사전연구)

  • Bae, Sung-Joon;Hwang, Sun-Ho;Shin, Chang-Hun
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.919-929
    • /
    • 2009
  • 2008, Seoulmetro transports an average of 3,952,000 passengers every day with a 0.8% increase of the daily ridership compared to last year.(Korean Economics '09.01.21) Seoul subway systems ridden by a considerable number of Seoul citizens place their top priority on swiftness, safety and clean underground air quality so as to meet the customer satisfaction. One of the most important problems is to eliminate minute dust(PM10) among the pollutants such as the gas attributable to air pollution and floating particulate matter defined by the ordinance of the Ministry of Environment. Seoulmetro install and operate many kinds of air filtration facilities, however we've launched a research on "Standardization Plan on Underground Air Filtration Facility" for the installation and improvement of optimum standardized air filtration system. As a preliminary study, we're going to consider ventilation system and air filter to supply filtered metropolitan outdoor air aimed at ensuring clean underground environment.

  • PDF

A Study of Wireless Sensor Network Routing Protocols for Maintenance Access Hatch Condition Surveillance

  • Lee, Hoo-Rock;Chung, Kyung-Yul;Jhang, Kyoung-Son
    • Journal of Information Processing Systems
    • /
    • v.9 no.2
    • /
    • pp.237-246
    • /
    • 2013
  • Maintenance Access Hatches are used to ensure urban safety and aesthetics while facilitating the management of power lines, telecommunication lines, and gas pipes. Such facilities necessitate affordable and effective surveillance. In this paper, we propose a FiCHS (Fixed Cluster head centralized Hierarchical Static clustering) routing protocol that is suitable for underground maintenance hatches using WSN (Wireless Sensor Network) technology. FiCHS is compared with three other protocols, LEACH, LEACH-C, and a simplified LEACH, based on an ns-2 simulation. FiCHS was observed to exhibit the highest levels of power and data transfer efficiency.

Heavy Rain and Flood Prevention in Urban (뉴스초점: 집중호우와 도시지역 홍수방어)

  • Jeong, Sun-Gil
    • Journal of the Korean Professional Engineers Association
    • /
    • v.43 no.6
    • /
    • pp.31-34
    • /
    • 2010
  • Recently, due to localized heavy rain and flash floods in urban areas is becoming more frequent flood damage. To prevent flood inundation damage, to formulate the diverse directions in connection with the drainage system of buildings, roads, sewerage, pump stations, detention (retention) pond, and streams is very important. In addition, it is important for the uniform design criteria, the consistent of hydrologic and hydraulic analysis method, and a flood disaster mitigation systems connected with structural and nonstructural measures. To accomplish this, the method such as installation of storage facilities, infiltration facilities, and underground water tank, the optimal size of the design gutter and grate of the road, ensure the capacity of pumping stations, and the installation of a flood control channel into the deep underground requires comprehensive measures dimension in urban areas.

  • PDF