• Title/Summary/Keyword: underground depth

Search Result 650, Processing Time 0.027 seconds

Application of HWAW Method to Detect Underground Anomaly in Shallow Depth (지표 근처 지중 이상체 파악을 위한 HWAW 기법의 적용)

  • Bang, Eun-Seok;Kim, Gyeong-Seob;Son, Jeong-Sul;Kim, Dong-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1C
    • /
    • pp.11-20
    • /
    • 2009
  • A new alternative method based on HWAW method to detect underground anomaly was introduced. The location of underground anomaly can be estimated by using 2-dimensional image of phase velocity image with position and wavelength based on distortion phenomena of surface wave due to underground anomaly. Overall procedure of proposed method such as field testing, signal processing and interpretation of the result was introduced. Numerical verification study was performed by using various ground models containing underground anomaly. According to the condition of anomaly, the propagation and reflection characteristics of surface wave were different and this could be more easily shown in the image of phase velocity. Some rules of distortion phenomena were found and these become clues for estimating underground anomaly in interpreting real field data. Field verification tests were performed with conventional geophysical methods such as DC resistivity method and GPR. Though field condition is not homogeneous like numerical models, similar distortion phenomena were found in the testing results and estimated location of underground anomaly was agreed well with the results of another geophysical methods.

Tunnel Safety Diagnosis in Near-excavation by In-depth Inspection of Tunnel (기존터널 안전진단 결과를 통한 근접시공 시 터널 안정성 평가)

  • Kim, Seok-Jae;Kim, Min-Seok;Kim, Jun-Chul;Yoo, Young-Il;Oh, Joung-Bae;Oh, Sae-Joon
    • Tunnel and Underground Space
    • /
    • v.16 no.4 s.63
    • /
    • pp.347-356
    • /
    • 2006
  • We analyzed case studies doing in-depth inspection of tunnel to maintain safety of existing tunnel in constructing new tunnel near to a existing tunnel with single track. Futhermore, We accomplished in-depth inspection of existing tunnel and numerical analysis. We suggested remedies to security safety of existing tunnel. We applied line drilling and pre-large hole boring method not to have an effect on existing tunnel and convinced the safety of existing tunnel from blast-vibration and blast-noise of numerical analysis. We planed to install basset system to measure displacement of existing tunnel according to excavating new tunnel.

Evaluation of Cave-in Possibility of a Shallow Depth Rock Tunnel by Rock Engineering Systems and Uumerical Analyses (암반공학시스템과 수치해석을 이용한 저심도 암반터널에서의 붕락 발생 가능성 평가)

  • Kim, Man-Kwang;Yoo, Young-Il;Song, Jae-Joon
    • Tunnel and Underground Space
    • /
    • v.19 no.3
    • /
    • pp.236-247
    • /
    • 2009
  • Overpopulation has significantly increased the use of underground spaces in urban areas, and led to the developments of shallow-depth underground space. Due to unexpected rock fall, however, it is very necessary to understand and categorize the rock mass behaviors prior to the tunnel excavation, by which unnecessary casualties and economic loss could be prevented. In case of cave-in, special attention should be drawn since it occurs faster and greater in magnitude compared to rock fall and plastic deformation. Types of cave-in behavior are explained and categorized using seven parameters - Uniaxial Compressive Strength (UCS), Rock Quality Designation (RQD), joint surface condition, in-situ stress condition, ground water condition, earthquake & ground vibration, tunnel span. This study eventually introduces a new index called Cave-in Behavior Index (CBI) which explains the behavior of cave-in under given in-situ conditions expressed by the seven parameters. In order to assess the mutual interactions of the seven parameters and to evaluate the weighting factors for all the interactions, survey data of the experts' opinions and Rock Engineering Systems (RES) were used due to lack of field observations. CBI was applied to the tunnel site of Seoul Metro Line No. 9. UDEC analyses on 288 cases were done and occurrences of cave-in in every simulation were examined. Analyses on the results of 288 cases of simulations revealed that the average CBI for the cases when cave-in for different patterns of tunnel support was estimated by a logistic regression analysis.

Underground Migration of $^{54}Mn,\;^{60}Co,\;^{85}Sr\;and\;^{137}Cs$ Deposited during the Growth of Major Crop Plants (주요 작물의 생육중에 침적한 $^{54}Mn,\;^{60}Co,\;^{85}Sr,\;^{137}Cs$ 의 지하이동)

  • Choi, Yong-Ho;Jo, Jae-Seong;Lee, Chang-Woo;Lee, Myung-Ho;Kim, Sang-Bog;Hong, Kwang-Hee;Choi, Geun-Sik;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.1
    • /
    • pp.51-58
    • /
    • 1996
  • Underground migration of $^{54}Mn,\;^{60}Co,\;^{85}Sr\;and\;^{137}Cs$ in paddy and upland conditions was studied through two years' greenhouse experiment. At early and late growth stages of rice, soybean, Chinese cabbage and radish, a mixed solution of the radionuclides was applied to the water or soil surfaces of the culture boxes filled with an acidic loamy-sandy soil for the upper 20cm. Soil was sampled in layers upto $15{\sim}20cm$ down after harvest. Soil concentrations of the radionuclides decreased exponentially with increasing soil depth and more than 80% of the radioactivities remained in top $3{\sim}4cm$. The mobility of the radionuclides decreased in the order of $^{85}Sr>^{54}Mn>^{60}Co{\geq}^{137}Cs$. Downward migrations of the radionuclides were the greatest in rice soil and the lowest in soybean soil which was fertilized with the least amount of N, P and K. Differences in depth profiles between two application times indicate that the amount of daily migration from $0{\sim}1cm$ layer to the lower area decreases with increasing time after deposition. By a simultaneous addition of KCl and lime following the earlier application, downward migration in soybean, Chinese cabbage and radish soils changed little or retarded more or less but that in rice soil accelerated a little.

  • PDF

A Study on Field Applicability of Underground Electric Heating Mesh (매설용 전기 발열 매시의 융설 효과에 대한 현장 적용성 연구)

  • Suh, Young-Chan;Seo, Byung-Seok;Song, Jung-Kon;Cho, Nam-Hyun
    • International Journal of Highway Engineering
    • /
    • v.15 no.2
    • /
    • pp.19-27
    • /
    • 2013
  • PURPOSES : This study aims to investigate the snow-melt effects of an underground electric heater's snow-melt system via a field performance test, for evaluating the suitability of the system for use on a concrete pavement. The study also investigates the effectiveness of dynamic measures for clearing snow after snowfall events. METHODS : In order to check the field applicability, in November 2010, specimens were prepared from materials used for constructing concrete pavements, and underground electric heating meshes (HOT-mesh) were buried at depths of 50 mm and 100 mm at the site of the Incheon International Airport Construction Research Institute. Further, an automatic heating control system, including a motion sensor and pavement-temperature-controlled sensor, were installed at the site; the former sensor was intended for determining snow-melt effects of the heating control system for different snowfall intensities. Pavement snow-melt effects on snowy days from December 2010 to January 2011 were examined by managing the electric heating meshes and the heating control system. In addition, data on pavement temperature changes resulting from the use of the heating meshes and heating control system and on the dependence of the correlation between the outdoor air temperature and the time taken for the required temperature rise on the depth of the heating meshes were collected and analyzed. RESULTS : The effects of the heating control system's preheat temperature and the hot meshes buried at depths of 50 mm and 100 mm on the melting of snow for snowfalls of different intensities have been verified. From the study of the time taken for the specimen's surface temperature to increase from the preheat temperature ($0^{\circ}C$) to the reference temperature ($5{\sim}8^{\circ}C$) for different snowfall intensities, the correlation between the burial depth and outdoor air temperature has been determined to be as follows: Time=15.10+1.141Depth-6.465Temp CONCLUSIONS : The following measures are suggested. For the effective use of the electric heating mesh, it should be located under a slab it may be put to practical use by positioning it under a slab. From the management aspect, the heating control system should be adjusted according to weather conditions, that is, the snowfall intensity.

GPR Analysis on Underground Features and Foundation Structure of Cheomseongdae, Gyeongju (GPR 탐사를 통해 본 경주 첨성대 기초 및 주변의 유구 분석)

  • Oh, Hyundok;Kwon, Moonhee;Jang, Hangilro
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.4
    • /
    • pp.264-271
    • /
    • 2019
  • Cheomseongdae in Gyeongju, known as an astronomical observatory, is a cultural monument with great historical, academic, and artistic value, as its unique shape is preserved well in its original form. The outer structure, ground stability, and seismic reliability of Cheomseongdae have been assessed by numerous researchers through various scientific methods, but research on the underground structure has been insufficient. This paper contains detailed models of the underground structure of Cheomseongdae interpreted in 2D and 3D images based on the data acquired through GPR surveys conducted of features in and around the base of Cheomseongdae. As a result, the existence of twelve small features arranged in a circle, although only about half of them remain, was confirmed at a depth of 0.4 - 0.6m. Furthermore, a structure three bays long (north-south direction) and four bays wide (east-west direction) was detected beneath Cheomseongdae at the depth of 0.7 - 1.0m. Other than 2 layers of foundations as is known, a square structure with the dimensions of 7m × 7m is situated at a depth of 0.6m, directly under Cheomseongdae, and what is reading that is expected to be the foundation structure of Cheomseongdae was detected and confirmed. This foundation structure is circular with a diameter in the east-west direction of 11m and in the north-south direction of 12m. The northern, western, and eastern edges of this foundation structure are about 1m away from the foundation of Cheomseongdae, whereas the the south side extends to about 5m wide.

A study on the structural safety of middle slab in double deck tunnel under live loads (활하중에 대한 복층터널 슬래브의 구조적 안전성에 관한 연구)

  • Kim, Tae Kyun;Kim, Se Kwon;Kim, Hyun Jun;Kim, Chang Young;Yoo, Wan Kyu;Hwang, Sung-Pil
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.2
    • /
    • pp.171-183
    • /
    • 2020
  • The purpose of this study is to analyze in advance the problems and improvements that may occur during the construction of intermediate slabs and the loading of intermediate slabs through the preliminary structural safety evaluation of intermediate slabs for Test bed structures in deep depth tunnels. The Test bed construction can verify and confirm the results of the design and construction technology development of large depth double deck tunnel through the process, and can also be used as a learning site for engineers and the general public to speed up the time of underground space development. There will be an opportunity to do this. In particular, the design load of middle slab built inside the circular deep-depth double-sided tunnel cross-section varies depending on the construction method and the construction equipment load used. Class 3 truck load of KL-510 assumed to be common load to upper and middle slab during loading and installation is loaded on upper and lower slab with different working position for each load combination Analyzed.

Field Application of RFID for the Cavity Maintenance of Under Pavement (도로하부 공동의 유지관리를 위한 RFID의 현장 적용성 평가)

  • Park, Jeong Jun;Shin, Eun Chul;Kim, In Dae
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.459-468
    • /
    • 2019
  • Purpose: The cavity exploration of the lower part of the road is carried out to prevent ground-sinking. However, the detected communities cannot be identified by the cavity location and history information, such as repackaging the pavement. Therefore, the field applicability of RFID systems was evaluated in this study to enable anyone to accurately identify information. Method: During temporary recovery, tag recognition distance and recognition rate were measured according to underground burial materials and telecommunication tubes using RFID systems with electronic tag chips attached to the bottom of the rubber cap. Result: The perceived distance and perceived rate of depth for each position of the electron tag did not significantly affect the depth up to 15cm, but it did have some effect if the depth was 20cm. In addition, water effects from nearby underground facilities and rainfall are relatively small, and the effects of wind will need to be considered during the weather conditions of the road. Conclusion: The RFID tags for field application of the pavement management system store various information such as location and size of cavity, identification date, cause of occurrence, and surrounding underground facilities to maximize cavity management effect with a system that can be computerized and mobile utilization.

Construction of Three Dimensional Soil Cadmium Pollution Map Using Geotechnical Information DB System (국토지반정보시스템을 이용한 3차원 토양오염지도 구축)

  • Hwang, Dae Young;Kang, In Joon;Jang, Yong Gu;Kim, Soo Kyum
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.4
    • /
    • pp.13-19
    • /
    • 2016
  • This study presented the build-up of three-dimensional soil pollution map for precise analysis. To do this, survey on the existing pollutant region on Dongnae-gu, Busan that is the study subject, showed that it tended to produce 0.72 clusters. So, this study suggested to investigate center of $1km{\times}1km $ grid and, as the results of comparing the pollution map that input pollution figure values based on the actually investigation point showed precise results. And, it divided the standard of pollution into 5 levels in surface and underground space and the map was built up using IDW interpolation against the amount of polluted substance. The pollution of ground surface, flow of polluted substance, coefficient of permeability and ground water level that are 504 geotechnical informations were selected as the influential parameters in pollution analysis of underground space, and it calculated that to 0~20 points by dividing the characteristics. It enables the build-up of pollution map of ground surface-underground with depth that considers the characteristics of soil layers and it is considered that it is possible to analyze the general infiltration. And, it was considered that it enables more accurate forecast about influential analysis per depth and pollution of underground water.

A development of the ground settlement evaluation chart on tunnel excavation (터널굴착에 따른 지반침하 예측을 위한 침하량 평가도표 개발)

  • Park, Chi Myeon;You, Kwang-Ho;Lee, Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1105-1123
    • /
    • 2018
  • The main risk factors of tunnel excavation through urban areas are ground settlement and surface sink which caused by ground conditions, excavation method, groundwater condition, excavation length, support method, etc. In the process of ground settlement assessment, the numerical analysis should be conducted considering the displacement and stress due to tunnel excavation. Therefore a technique that can simplify such process and easily evaluate the influence of tunnel excavation is needed. This study focused on the tunnelling-induced ground settlement which is main consideration of underground safety impact assessment. The parametric numerical analyses were performed considering such parameters as ground conditions, tunnel depth, and lateral distance from tunnel center line, etc. A simplified ground settlement evaluation chart was suggested by analyzing tendency of ground subsidence, lateral influence area and character by depth. The applicability of the suggested settlement evaluation chart was verified by comparative numerical analysis of settlement characteristics.