• Title/Summary/Keyword: underground LPG

Search Result 52, Processing Time 0.019 seconds

The Optimal Design of Explosion Prevention for LPG Storage Tank (폭발방지를 고려한 LPG 저장탱크 최적설계)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Son, Seok-Woo;Lim, Jae-Ki
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.949-952
    • /
    • 2010
  • The utilization of LPG(Liquefied Petroleum Gas) is increasing as an environmental-friendly fuel in all countries making green growth new paradigm, and use of gas is spread fast as motor fuels to decrease air pollution. Loss of lives by explosion and fire is happening every year as gas use increases, and gas accident in large scale storage property is causing serious problems socially. To minimize this problem, underground containment type storage tank is being presented as an alternative recently. In this study, to minimize explosion occurrence in underground containment type storage tank, the suitable storage tank is designed to consider explosion prevention that makes exposure surface area minimize in confined contents volume and flame to construct storage tank by the most suitable condition in the underground containment room. As a result of the design of storage tank having the most suitable condition by this research, underground containment space was minimized on diameter 3m, length 4.83m in 20 tons storage tank and its safety was improved as exposure surface area in flame decreased by 89.4%, compared with the existent storage tank.

  • PDF

A Comparative Study on the Safety Management Status of LP Gas Fueled Vehicles in Korea and Foreign Countries (LP가스 연료사용 자동차의 국내외 안전관리현황 비교 연구)

  • Tak, Song-Su;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.2
    • /
    • pp.49-56
    • /
    • 2009
  • This thesis suggests ways for ensuring the safety of domestic autogas (liquefied petroleum gas) vehicles by conducting comparison and analysis on the status of market diffusion and safety management scheme in foreign countries as well as in Korea. According to the result of the survey on the status of domestic autogas safety management, the national scheme to secure the safety of autogas vehicles seems neither well-organized nor sufficiently-controlled. Actually, the gas leakage check-ups conducted for 5,000 autogas cars revealed that about 4 percent of them had leakage problems. As a result, it was acknowledged that the autogas safety regulations being operated in advanced countries need to be selectively introduced for the domestic autogas industry. Consequently, in line with the recent permission to use autogas as a fuel for subcompact cars etc., this thesis is recommending some methods to enhance the safety management scheme for autogas cars such as the amendment of facility regulations including the ventilation of underground parking lots, mandatory attachment of labels claiming autogas cars and indicating periodical inspections etc.

  • PDF

Comparison of hydrochemical informations of groundwater obtained from two different underground storage systems

  • Lee, Jeonghoon;Kim, Jun-Mo;Chang, Ho-Wan
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.110-113
    • /
    • 2002
  • Statistical- based, principal component analysis (PCA) was applied to chemical data from two underground storage systems containing LPG to assess the usefulness of such technique at the initial stage (Pyeongtaek) or middle stage (Ulsan) of hydrochemical studies. For the first case, both natural and anthropogenic contamination characterize regional groundwater. Saline water buffered by Namyang lake affects as a natural factor, whereas cement grouting influence as an artificial factor. For the second study area, contaminations due to operation of LPG caverns, such as disinfection activity and cement grouting effect, deteriorate groundwater quality. This study indicates that principal component analysis would be particularly useful for summarizing large data set for the purpose of subsurface characterization, assessing their vulnerability to contamination and protecting recharge zones.

  • PDF

A Survey of Autogas Car Driver's Attitude on Safe Driving (LPG 자동차 안전운행을 위한 운전자 의식조사)

  • Tak, Song-Su;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.2
    • /
    • pp.36-40
    • /
    • 2009
  • In this study, we surveyed 544 drivers, who had taken the education course for autogas car drivers, to figure out their safety awareness status including the recognition of hazards of gas leaking from autogas cars and response attitude toward them. As a result of the survey, we found out that 63% of the responders recognized the hazards of gas leakage and 79% preferred parking in the aboveground areas. For the necessity of introducing restrictions on autogas cars parking in underground lots, 58% of all responders answered yes while 71% of the responders aged over fifties and 73% of them who responded to have known the hazards of parking in underground answered in the affirmative. Furthermore, we found out that responders who had recognized the hazards preferred aboveground parking areas, and the responders who had preferred the aboveground recognized the hazards of parking autogas cars underground and felt the necessity of restricting them from parking in underground relatively high. Through the analysis of these results, we can analyse that the drivers who are aware of the hazards of gas leakage have higher safety attitude for hazards than the other drivers who are not aware of them.

  • PDF

A Study on the Possibility of BLEVE and UVCE for a LPG Storage Tank of Underground Containment Type (지하격납형 LPG 저장탱크에서의 BLEVE와 UVCE 가능성 해석)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Lee, Jong-Rark
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.05a
    • /
    • pp.313-315
    • /
    • 2008
  • 본 논문에서는 지하격납형 LPG저장탱크에서의 가스누출로 인한 폭발의 가능성을 파악하기 위한 것으로, 국내 LPG저장탱크의 설치는 가스관계법에 의하여 지상형과 지하매몰형이 있으며, 지상형은 화염 등에 의한 위험성이 높으며, 지하매몰형은 부식 등에 의한 경제적 손실이 크다. 따라서 지상형과 지하매몰형의 장점을 취한 지하격납형 LPG저장탱크의 안전성을 통한 법 적용여부를 파악하기 위한 기본연구이다.

  • PDF

Prediction of Leachate Migration from Waste Disposal Site to Underground LPG Storage Facility and Review of Contamination Control Method by Numerical Simulations (수치모의를 통한 지하 LPG 저장시설에 인접한 폐기물매립지에서의 침출수이동 예측 및 제어공법 검토)

  • 한일영;서일원;오경택
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.3 no.2
    • /
    • pp.51-59
    • /
    • 1996
  • In case waste disposal site is to be constructed close to the underground facilities such as LPG storage cavern which is completely maintained by groundwater pressure, it is generally requested that the possibility on leachate contamination of cavern area be reviewed and the countermeasure, if it is estimated cavern area is severely affected by leachate, be taken into consideration. Prediction was performed and leachate control plan was made using by analytical and the numerical analysis on the leachate migration which is likely to happen at the area between the proposed waste disposal site and the underground LPG storage cavern located at the U petrochemical complex. Analytical solutions were obtained by the conservative mass advection-diffusion equation and the effect of advection and dispersion factor on the leachate migration was reviewed through peclet number calculation and the functional relationship between the factors and leachate transport velocity was established, which leads to enable us to predict the leachate transport velocity without difficulties when different parameters (factors) are used for analytical solution. Numerical solutions were obtained by FEM using AQUA2D which is for the simulation of groundwater flow and contaminant transport. 3-D discrete fracture models were simulated and fracture flow analysis was performed and feasibility study on the water-curtain system was conducted through the fracture connectivity analysis in rock mass. As results of those analyses, it was interpreted that the leachate would trespass on the LPG storage cavern area in 30 years from the proposed wate disposal site and the vertical water-curtain system was effective mathod for the prevention of leachate's migration further into the cavern area.

  • PDF

A Study on the Economic Analysis for Installation Method of Storage Tank in LPG Filling Station (LPG 충전소 저장탱크의 설치방법에 따른 경제성 분석에 관한 연구)

  • Huh, Yong-Jeong;Lim, Ju-Yeon;Youm, Moo-Youl;Leem, Sa-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.1
    • /
    • pp.23-28
    • /
    • 2016
  • "Eco-friendly" automobile has been a symbol of the Low Carbon, Green Growth strategy that Korea government decided to pursue. In line with the recent policy trend, a number of new LPG stations are being constructed. However, communities where mass storage are installed have been suffered from risk of serious accidents. In this work, economic analyses for different installation methods has been performed to prevent accidents in LPG filling station. The review shows that the underground storage is beneficial for the maintenance and the effective land use.

Investigation of the LPG Gas Explosion of a Welding And Cutting Torch at a Construction Site

  • Lee, Su-kyung;Lee, Jung-hoon;Song, Dong-woo
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.811-818
    • /
    • 2018
  • A fire and explosion accident caused by a liquefied petroleum gas (LPG) welding and cutting torch gas leak occurred 10 m underground at the site of reinforcement work for bridge columns, killing four people and seriously injuring ten. We conducted a comprehensive investigation into the accident to identify the fundamental causes of the explosion by analyzing the structure of the construction site and the properties of propane, which was the main component of LPG welding and cutting work used at the site. The range between the lower and upper explosion limits of leaking LPG for welding and cutting work was examined using Le Chatelier's formula; the behavior of LPG concentration change, which included dispersion and concentration change, was analyzed using the fire dynamic simulator (FDS). We concluded that the primary cause of the accident was combustible LPG that leaked from a welding and cutting torch and formed a explosion range between the lower and upper limits. When the LPG contacted the flame of the welding and cutting torch, LPG explosion occurred. The LPG explosion power calculation was verified by the blast effect computation program developed by the Department of Defense Explosive Safety Board (DDESB). According to the fire simulation results, we concluded that the welding and cutting torch LPG leak caused the gas explosion. This study is useful for safety management to prevent accidents caused by LPG welding and cutting work at construction sites.