• Title/Summary/Keyword: unconfined compression

Search Result 281, Processing Time 0.032 seconds

A Study on Cover Material of Waste Landfill with Engineered Stone Sludge (폐기물 매립지의 복토재로 엔지니어드스톤 슬러지의 활용에 관한 연구)

  • Kim, Youngtae;Ahn, Kwangkuk;Kang, Hongsig
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.7
    • /
    • pp.5-10
    • /
    • 2022
  • The industrial waste is becoming a big problem in the aspect of spatial and environmental in domestic and international. Therefore, the waste reduction and recycling policy has been being implemented as a way to solve this problem. The engineered stone sludge, which is waste, is generated duing the engineered stone production process. since engineered stone sludge is mostly treated by landfill, an increase in the amount of the sludge leads to an increase in landfill sites and treatment costs. therefore, there is a need for a method of resourcization with engineered stone sludge. So, laboratory tests (Plastic and liquid limits, compaction, unconfined compression and permeability test) were conducted to confirm the possibility of using engineered stone sludge mixed with weathered granite soil as a cover material for landfill in this study. The result shows that the mixed soil material with less that 62.5% of engineered stone sludge can be used as a cover material for landfill.

Study on Cement-based Grout for Closed-loop Vertical Grout Heat Exchanger (수직 밀폐형 지중열교환기 뒤채움재로서 시멘트 그라우트의 적용성 검토)

  • Park, Moon-Seo;Wi, Ji-Hae;Lee, Chul-Ho;Choi, Hang-Seok;Kang, Shin-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.107-115
    • /
    • 2010
  • In this paper, the applicability of cement grout bas been studied as an alternative to bentontite grout to backfill ground heat exchangers. To provide an optimal mixture design, the groutabilty and thermal conductivity of cement grouts with various mixture ratios were experimentally evaluated and compared. The unconfined compression strength of cement grout specimen was measured, which was exposed to cyclic temperature variation ranging from $50^{\circ}C$ to $-5^{\circ}C$. In addition, the integrity of the interface between circulating HDPE pipes and cement grout was evaluated by performing equivalent hydraulic conductivity tests, on the specimen. in which a pipe locates at the center of the specimen.

Design of IGM Socketed Drilled Shafts Using Texas Cone Penetrometer Tests (텍사스 콘 관입시험을 이용한 IGM에 근입된 현장타설말뚝의 설계)

  • Nam, Moon-S.
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.10
    • /
    • pp.55-67
    • /
    • 2006
  • Modern methods for designing IGM(Intermediate Geomaterial) socketed drilled shafts require knowledge of the compressive strength and modulus of the IGM. However, the weathered IGMs at many sites prohibit the recovery of samples of sufficient length and integrity to test cores in either unconfined or triaxial compression tests. Since rational design procedures usually require values of compressive strength, surrogate methods must be employed to estimate the compressive strength of the IGM. A surrogate method considered in this study was Texas cone penetrometer tests which were performed at several sites in North Central Texas. Correlations of Texas cone penetrometer tests and compressive strengths of cores from these formations are provided in the paper. In order to develop the relationships between Texas cone penetrations and side and base resistance of IGM socketed drilled shafts, three filed load tests were conducted in the same sites. Based on the field study and literature reviews, a design method for IGM socketed drilled shafts using Texas cone penetration test was proposed.

Bearing Capacity Evaluation of Marine Clay Dredged Deposit Including Desiccated Crust Layer (건조 고결층이 형성된 준설 매립 지반의 지지력 산정에 대한 연구)

  • Park, Hyun-Ku;Byeon, Wi-Yong;Jee, Sung-Hyun;Lee, Seung-Rae
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.5
    • /
    • pp.89-100
    • /
    • 2007
  • In this study, various field and laboratory tests were performed to investigate the characteristics of shear strength and bearing behavior to be considered in the estimation of stability and trafficability in early stage of stabilization process in marine clay dredged deposit. Site characterization was carried out to grasp the basic properties of the deposit. Field vane test, unconfined compression test and direct shear test were conducted to evaluate the shear strength distribution for varied depths, and the characteristics of shear strength and stress-strain behavior of the crust layer. Plate load tests were also performed to estimate the bearing capacity and to assess load-settlement behavior and failure pattern of the deposit. The bearing capacity was also estimated using previously proposed methods for double-layered clay deposit. The estimated bearing capacity was compared with the results of the plate load tests and then, the applicability of the estimation method was discussed.

A Study for the Applicable Bearing-Resistance of Bearing Anchor in the Enlarged-Borehole (지압형 앵커의 지압력 산정에 관한 실험적 연구)

  • Min, Kyoung-Nam;Lee, Jae-Won;Lee, Jung-Gwan;Jung, Chan-Muk
    • The Journal of Engineering Geology
    • /
    • v.24 no.2
    • /
    • pp.261-271
    • /
    • 2014
  • An almost permanent anchor (friction type) is resistant to ground deformation due to the friction between the soil and grout at a fixed length from the anchor body. The purpose of this study is to calculate the force of bearing resistance for a bearing anchor in enlarged boreholes. We conducted analytical and numerical analyses, along with laboratory testing, to find the quantities of bearing resistance prior to grouting in EBA (Enlarged Bearing Anchor) construction. The force of bearing resistance from the analytical method was defined as a function of general borehole diameter, expanded borehole diameter, and soil unconfined compressive strength. We also employed the Flac 3D finite difference numerical modeling code to analyze the bearing resistance of the soil conditions. We then created a laboratory experimental model to measure bearing resistance and carried out a pull-out test. The results of these three analyses are presented here, and a regression analysis was performed between bearing resistance and uniaxial compression strength. The laboratory results yield the strongest bearing resistance, with reinforcement 28.5 times greater than the uniaxial compression strength; the analytical and numerical analyses yielded values of 13.3 and 9.9, respectively. This results means that bearing resistance of laboratory test appears to be affected by skin friction resistance. To improve the reliability of these results, a comparison field study is needed to verify which results (analytical, numerical, or laboratory) best represent field observations.

Hydraulic Conductivity and Strength Characteristics of Self Recovering Sustainable Liner (SRSL) as a Landfill Final Cover (SRSL 매립지 최종 복토층의 투수 및 강도 특성)

  • Kwon, Oh-Jung;Lee, Ju-Hyung;Cho, Wan-Jei;Jung, Young-Hoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.12
    • /
    • pp.5-15
    • /
    • 2011
  • Conventional designs of landfill covers use geosynthetics such as geomembrane and GCL, and clay liners to lower the permeability of final covers of landfill sites. However, differential settlement and the variation of temperature or humidity in landfill sites cause the development of cracks or structural damage inside the final cover. This study examined the application of a Self Recovering Sustainable Liner (SRSL) as an alternative landfill final cover material. SRSL consists of double layers, which have chemicals, can generate precipitates filling the pores of the layers by chemical reaction. The interface material forms an impermeable layer and in case of internal cracks, the reactants of the two layers migrate towards the crack and heal it by forming another liner. In this study the applicability of SRSL material for landfill final cover was examined by performing flexible wall permeameter tests to prove that the hydraulic conductivity is lower than the regulations and unconfined compression tests to judge whether the strength satisfies the restriction for the landfill final cover. Furthermore, the environmental impacts on the permeability and strength were evaluated. The experimental results show that the SRSL has lower hydraulic conductivity and higher strength than the regulations and is little influenced by climatic changes such as wet/dry or freeze/thaw process.

Characteristics of the Expanded Road Embankment Constructed by Lightweight Air-Mixed Soils for a Short-Term (경랑기포혼합토로 단기간에 시공된 확폭도로성토체의 특성)

  • Hwang, Joong Ho;Ahn, Young Kyun;Lee, Young-Jun;Kim, Tae-Hyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4D
    • /
    • pp.377-386
    • /
    • 2010
  • This study was conducted to find out the characteristics of the expanded road embankment constructed by the lightweight air-mixed soil (slurry density $10kN/m^3$) for a short-term without any ground improvement. Compression strength, capillary rise height of the lightweight air-mixed soil and settlement behavior of soft ground were studied. Compression strengths of the specimens sampled at the site after 1 and 5 months of construction were all satisfied the required strength 500 kPa. However, it was not convinced the homogeneity construction, because the values of strength were depending on the sampled location. Also, strength difference between laboratory and site specimens were found about 19%, and thus it should be considered for mixing design. Capillary rise reached about 20 cm for 70 hours because of a numerous tiny pores existed inside the lightweight air-mixed soil. Relationship between settlement and time of the soft ground placed underneath the expanded embankment was estimated by using the measured data and back analysis technique. The current average consolidation ratio and the final settlement after 120 months later were estimated about 32% and 4.5cm, respectively. This settlement is much less value than the allowable settlement 10cm for this structure.

Study on the Direct Tensile Test for Cemented Soils Using a Built-In Cylinder (내장형 실린더를 이용한 시멘트 고결토의 인장시험 방법에 관한 연구)

  • Park, Sung-Sik;Lee, Jun-Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1505-1516
    • /
    • 2014
  • In this study, a cylinder embedded within cemented soils was used to cause directly tensile failure of cemented soils. An existing dumbbell type direct tensile test and a split tensile test that is most general indirect tensile test were also carried out to verify the developed built-in cylinder tensile test. Testing specimens with two different sand/cement ratios (1:1 and 3:1) and two curing periods (7 and 28 days) were prepared and tested. Total 10 specimens were prepared for each case and their average value was evaluated. Unconfined compression tests were also carried out and the ratio of compressive strength and tensile strength was evaluated. The tensile strength determined by built-in cylinder tensile test was slightly higher than that by dumbbell type direct tensile test. The dumbbell type test has often failed in joint part of specimen and showed some difficulty to prepare a specimen. Among three tensile testing methods, the standard deviation of tensile strength by split tensile test was highest. It was shown that the split tensile test is applicable to concrete or rock with elastic failure but not for cemented soils having lower strength.

An Analysis of Behavior and Strength of Cement using Improved Materials by Laboratory Model Test (실내 모형실험에 의한 지반보강 개량체 특성 분석)

  • Oh, Philjin;Park, Minchul;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.7
    • /
    • pp.19-29
    • /
    • 2012
  • For foundation of Port structure, it is essential geotechnical understanding about feature of ground and the geologic formation which is different to terrestrial ground. What is most important is the understanding of soft ground clay, which is much softer than terrestrial ground. To build foundation of a port structure which is mainly gravity based on the special geographical circumstance that is on the sea, the improvement method of foundation should be applied according to soft clay ground features. Therefore, in this study, the behaviors of improved materials with strength were analyzed on the soft clay foundation where suppose to be located the foundation of port structure. The laboratory model test has been conducted in 2 cases with unconfined compression strength of improved materials, 25kPa and 125kPa. Cement, water, and in-situ soft clay were combined at a fixed rate and made a shape of 5cm diameter ${\times}$ 70cm height column. Improved materials were located with replacement ratio(11%, 35% and 61%) in 38cm diameter ${\times}$ 80cm height cylinder. Finally, the stress distribution ratio on the improved materials and clay, settlement was analyzed by applying a load of 10kPa, 30kPa, and 50kPa.

Confinement Effect by Plate Type Lateral Reinforcement and Investigation of the Possibility for Use of High Strength Steel Bars in Reinforced Concrete Columns (횡방향 판재에 의한 횡구속 효과 및 철근콘크리트 기둥에서 고강도 철근의 사용성 검토)

  • Cho, Young-Jae;Kim, Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.643-650
    • /
    • 2012
  • The limitation of the yield strength in reinforced concrete columns is given for the effective use of high-strength steel bar, because very high-strength steel bar does not yield while concrete fails in compression. In order to overcome this limitation, it is required to increase peak strain of the concrete. The objective of this study is to examine the confinement effect of plate type lateral reinforcement in reinforced concrete columns. From this experimental study, the reinforced concrete columns confined by plate type carbon fiber sheets showed higher compressive strength and peak concrete strain comparing to the unconfined columns. The confinement effect is higher when cross-sectional type is a circular one than a square one. Moreover, the confinement effect was also higher for circular type confinement. Based on this study, high-strength steel bars with strength exceeding 800 MPa can be effectively used for reinforced concrete columns confined by plate type lateral reinforcements.