• Title/Summary/Keyword: uncertainty measurement

Search Result 936, Processing Time 0.032 seconds

Evaluation of a Fungal Spore Transportation in a Building under Uncertainty

  • Moon, Hyeun Jun
    • Architectural research
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 2006
  • A fungal spore transportation model that accounts for the concentration of airborne indoor spores and the amount of spores deposited on interior surfaces has been developed by extending the current aerosol model. This model is intended to be used for a building with a mechanical ventilation system, and considers HVAC filter efficiency and ventilation rate. The model also includes a surface-cleaning efficiency and frequency that removes a portion of spores deposited on surfaces. The developed model predicts indoor fungal spore concentration and provides an indoor/outdoor ratio that may increase or decrease mold growth risks in real, in-use building cases. To get a more useful outcome from the model simulation, an uncertainty analysis has been conducted in a real building case. By including uncertainties associated with the parameters in the spore transportation model, the simulation results provide probable ranges of indoor concentration and indoor/outdoor ratio. This paper describes the uncertainty quantification of each parameter that is specific to fungal spores, and uncertainty propagation using an appropriate statistical technique. The outcome of the uncertainty analysis showed an agreement with the results from the field measurement with air sampling in a real building.

A Suggestion of Fuzzy Estimation Technique for Uncertainty Estimation of Linear Time Invariant System Based on Kalman Filter

  • Kim, Jong Hwa;Ha, Yun Su;Lim, Jae Kwon;Seo, Soo Kyung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.7
    • /
    • pp.919-926
    • /
    • 2012
  • In order to control a LTI(Linear Time Invariant) system subjected to system noise and measurement noise, first of all, it is necessary to estimate the state of system with reliability. Kalman filtering technique has been widely used to estimate the state of the stochastic LTI system with stationary noise characteristics because of its estimation ability versus algorithm simplicity. However, it often fails to estimate the state of the LTI system of which system parameter uncertainty exists partly and/or input uncertainty exists. In this paper, a new estimation technique based on Kalman filter is suggested for stochastic LTI system under parameter uncertainty and/or input uncertainty. A fuzzy estimation algorithm against uncertainties is introduced so as to compensate the state estimate filtered by Kalman filter. In order to verify the state estimation performance of the suggested technique, several simulations are accomplished.

Uncertainty in the Calibration of Coaxal Thermal Noise Sources using a Noise Figure Measuring Equipment

  • Kang, Tae-Weon;Kim, Jeong-Hwan;Park, Jeong-Il
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.2
    • /
    • pp.79-86
    • /
    • 2004
  • In this paper, the uncertainty in the calibration of coaxial thermal noise sources using a noise figure measuring (NFM) equipment is evaluated. Contributions to the uncertainty such as the calibration uncertainty of the standard noise source, mismatch, measurement of adapter efficiency, ambient temperature variation, and repeatability are evaluated in the frequency range of 10 MHz to 18 ㎓. Results show that the expanded uncertainty(k=2) is 0.23 ㏈ for the noise sources of 5 ㏈ and 15 ㏈ ENR, and 0.27 ㏈ for those of 21 ㏈.

Evaluation of the Measurement Uncertainty from the Standard Operating Procedures(SOP) of the National Environmental Specimen Bank (국가환경시료은행 생태계 대표시료의 채취 및 분석 표준운영절차에 대한 단계별 측정불확도 평가 연구)

  • Lee, Jongchun;Lee, Jangho;Park, Jong-Hyouk;Lee, Eugene;Shim, Kyuyoung;Kim, Taekyu;Han, Areum;Kim, Myungjin
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.6
    • /
    • pp.607-618
    • /
    • 2015
  • Five years have passed since the first set of environmental samples was taken in 2011 to represent various ecosystems which would help future generations lead back to the past environment. Those samples have been preserved cryogenically in the National Environmental Specimen Bank(NESB) at the National Institute of Environmental Research. Even though there is a strict regulation (SOP, standard operating procedure) that rules over the whole sampling procedure to ensure each sample to represent the sampling area, it has not been put to the test for the validation. The question needs to be answered to clear any doubts on the representativeness and the quality of the samples. In order to address the question and ensure the sampling practice set in the SOP, many steps to the measurement of the sample, that is, from sampling in the field and the chemical analysis in the lab are broken down to evaluate the uncertainty at each level. Of the 8 species currently taken for the cryogenic preservation in the NESB, pine tree samples from two different sites were selected for this study. Duplicate samples were taken from each site according to the sampling protocol followed by the duplicate analyses which were carried out for each discrete sample. The uncertainties were evaluated by Robust ANOVA; two levels of uncertainty, one is the uncertainty from the sampling practice, and the other from the analytical process, were then compiled to give the measurement uncertainty on a measured concentration of the measurand. As a result, it was confirmed that it is the sampling practice not the analytical process that accounts for the most of the measurement uncertainty. Based on the top-down approach for the measurement uncertainty, the efficient way to ensure the representativeness of the sample was to increase the quantity of each discrete sample for the making of a composite sample, than to increase the number of the discrete samples across the site. Furthermore, the cost-effective approach to enhance the confidence level on the measurement can be expected from the efforts to lower the sampling uncertainty, not the analytical uncertainty. To test the representativeness of a composite sample of a sampling area, the variance within the site should be less than the difference from duplicate sampling. For that, a criterion, ${i.e.s^2}_{geochem}$(across the site variance) <${s^2}_{samp}$(variance at the sampling location) was proposed. In light of the criterion, the two representative samples for the two study areas passed the requirement. In contrast, whenever the variance of among the sampling locations (i.e. across the site) is larger than the sampling variance, more sampling increments need to be added within the sampling area until the requirement for the representativeness is achieved.

Measurement uncertainty Improvement of ERA PD measuring system in teat laboratory (ERA 부분방전 측정시스템의 측정불확도개선)

  • Heo, Jong-Cheol;Kim, We-Young;Kim, Seok-Sou;Oh, Chang-Soo;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1509-1510
    • /
    • 2006
  • ERA PD measuring system has been using for partial discharge evaluation of power appratus in test laboratories. So, the measurement uncertainty of PD measuring system (ERA), such as PD pulse calibrator rise and fall time, sacle factor(k) and linearity, transfer impedance etc, is very important factor of test result in test laboratory. In this paper, we describe tracebility and uncertainty improvement of PD measuring system in test laboratory based on IEC 60270.

  • PDF

Uncertainty Analysis of Containment Leak Rate Test System (격납건물 누설 시험장치의 불확실도 평가)

  • Lee, Kwang-Dae;Yang, Seung-Ok;Oh, Eung-Se
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.635-637
    • /
    • 2004
  • The containment of the nuclear power plant is the last barrier of radiation release when the reactor coolant pipe rupture is occurred. Each plant has to be tested every 5 years whether the containment leak rate meets its technical specifications. We have developed the leak rate test system and in this paper, we describe the results of the uncertainty analysis on the measurement channels and its propagation to the calculation results.

  • PDF

Robust Control of Input Delayed Systems with Structured Uncertainty (구조화된 불확실성을 갖는 입력지연 시스템의 강인제어)

  • 이보형
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.270-270
    • /
    • 2000
  • Input delay is frequently encountered in the practical systems since measurement delay and computational delay can be represented by input delay. In this viewpoint, this paper deals with the robust control problem of input delayed systems with structured uncertainty. Robust stability conditions are provided in terms of linear matrix inequalities(LMIs) and it is shown that the proposed conditions can give less conservative maximum bound of input delay guaranteeing robust stability.

  • PDF

Analytical method for analyzing formaldehyde using 2, 4-DNPH and gas chromatography/FID, NPD (2,4-DNPH와 가스크로마토그래프를 이용한 포름알데히드 분석방법)

  • Jeong, Jee Yeon;Park, Seung Hyun;Yi, Gwang Yong;Oh, Se Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.126-146
    • /
    • 2000
  • To develop and evaluate formaldehyde measurement method using 2,4-dinitro-phenylhydrazine (2,4-DNPH) coated sampler and gas chromatography, laboratory test and field test were conducted. Results of this study are as follows. Limit of detection(LOD) of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is $0.008{\mu}g/m{\ell}$ $0.060{\mu}g/m{\ell}$, $0.472{\mu}g/m{\ell}$ respectively. Coefficiency of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is 0.008, 0.009, 0.020 respectively. Desorption efficiency of sep-pak xposure aldehyde sampler and sorbent sample tube is 1.05(range : 0.99 - 1.12), 1.02(range : 0.99 - 1.06) respectively. Samples of sorbent sample tube and sep-pak xposure aldehyde sampler turned out to be stored at refrigerator, according to storage test results. Measurement methods of HPLC-UVD, GC-NPD, GC-FID, according to results of precision for the combined sampling and analytical procedure, became acceptable to OSHA evaluation standard. Field test using exposure chamber met the NIOSH overall uncertainty recommendation(less than 25%). Overall uncertainty of Sepak-HPLC(UVD), Tube-GC(NPD), Tube-GC(FID) is 11.0% - 17.0%. Consequently gas chromatography(GC-NPD, GC-FID) and high performance liquid chromatography(EPA TO-11) using 2,4-DNPH coated sampler for formaldehyde measurement turned out to be suitable to measure personal formaldehyde exposure at workplaces.

  • PDF

Experimental Approach to Equalizing the Orifice Method with the Throughput One for the Measurement of TMP Pumping Speed

  • Lim, J.Y.;Kang, S.B.;Shin, J.H.;Koh, D.Y.;Cheung, W.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.18-18
    • /
    • 2010
  • Methods of the characteristics evaluation of turbo-molecular pumps (TMP) are well-defined in the international measurement standards such as ISO, PNEUROP, DIN, JIS, and AVS. The Vacuum Center in the Korea Research Institute of Standards and Science has recently designed, constructed, and established the integrated characteristics evaluation system of TMPs based on the international documents by continuously pursuing and acquiring the reliable international credibility through measurement perfection. The measurement of TMP pumping speed is normally performed with the throughput and orifice methods dependent on the mass flow regions. However, in the UHV range of the molecular flow region, the high uncertainties of the gauges, mass flow rates, and conductance are too critical to precisely accumulate reliable data. With UHV gauges of uncertainties less than 15% and a calculated conductance of the orifice, about 35% of pumping speed uncertainties are experimentally derived in the pressure range of less than $10^{-6}$ mbar. In order to solve the uncertainty problems of pumping speeds in the UHV range, we introduced an SRG with 1% accuracy and a constant volume flow meter (CVFM) to measure the finite mass flow rates down to $10^{-3}$ mbar-L/s with 3% uncertainty for the throughput method. In this way we have performed the measurement of pumping speed down to less than $10^{-6}$ mbar with an uncertainty of 6% for a 1000 L/s TMP. In this article we suggest that the CVFM has an ability to measure the conductance of the orifice experimentally with flowing the known mass through the orifice chambers, so that we may overcome the discontinuity problem encountering during introducing two measurement methods in one pumping speed evaluation sequence.

  • PDF