• Title/Summary/Keyword: ultrasonic radiation

Search Result 133, Processing Time 0.018 seconds

A Study on Ultrasonic Image Diagnosis Methods of Tooth Defect with Phased-Array Techniques (위상배열기법을 이용한 치아결함 초음파이미지 진단기술개발)

  • Oh, Yun-Jung;Hwang, In-Nam;Park, Su-Jung;Im, Kwang-Hee;Cho, Hyun-Joon;Cho, Young-Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.604-613
    • /
    • 2009
  • Recently, researches to develop phased array ultrasonic examination techniques are proceeded to diagnose dental caries and the status of surgical operation of dental implant. Sound field analysis of phased array ultrasonic transducers were carried out in order to characterizing the ultrasonic phased array beams. The sound field of ultrasonic radiation was calculated for the sample called "gypsum-improved stone" with the similar characteristics of dental materials. Industrial phased array ultrasonic devices were utilized for the insptriion of the artificial flaws machined in the gypsum-improved stone. Dental implants were made at the pig jaw bone and defect images were confirmed for the dental implants.

  • PDF

Numerical Analysis of Ultrasonic Radiation Intensities (In Liquid) (초음파의 세기를 구하기 위한 수치 해석적 방법)

  • Lee, Sang Hee
    • Journal of Industrial Technology
    • /
    • v.8
    • /
    • pp.65-70
    • /
    • 1988
  • The intensity of ultrasound in liquid is calculated by improved analytic method. Helmholtz equation or Rayleigh's proposition does not offer the analytic solution. Considering a bounded medium, the use of the image source method in electromagnetic thoery gives a new way of calculating the total ultrasonic intensity in liquid. Some methods of measuring the intensities are also mentioned.

  • PDF

Investigation of standing wave acoustic levitation with Bernoulli principle and bolt-clamped Langevin type ultrasonic transducer (베르누이 원리와 bolt-clamped Langevin type 초음파 진동자를 이용한 정상파 음파 공중부양의 탐구)

  • Park, Mincheol;Park, Doojae;Kim, Young H.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.6
    • /
    • pp.422-427
    • /
    • 2018
  • The purpose of this study is to investigate the effect of acoustic radiation force on the standing wave acoustic levitation phenomenon, which is the levitation of small objects near the pressure node of the standing wave, using the Bernoulli principle. The source and scheme of the acoustic radiation force, which is the cause of the levitation, are conceptually explained through comparison with the graph of the acoustic radiation force versus the distance from the transducer. A series of experiments supporting this explanation was performed with a BLT(Bolt-clamped Langevin Type) ultrasonic transducer to confirm that the objects are floating near the pressure nodes and that it satisfies the condition for the standing wave formation when the object is levitating. Furthermore, the vertical alignment of floating objects, which is a characteristic of standing wave acoustic levitation phenomenon, could be explained.

Acoustic Power Measurement System of Array Probes for Ultrasonic Diagnostic Equipment Using Radiation Force Balance Methods (방사힘 측정법을 이용한 초음파 진단장치용 배열 탐침자의 음향파워 측정시스템)

  • Yun, Yong-Hyeon;Jho, Moon-Jae;Kim, Yong-Tae;Lee, Myoung-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.355-364
    • /
    • 2010
  • Considering biological safety, it is very important to measure acoustic power from ultrasonic array probe for diagnostic ultrasound imaging applications. In this paper, to measure acoustic power from each element on array probe for ultrasonic diagnostic equipment, we reconstruct and automate the acoustic power measurement system. The acoustic power from linear, phased and curved array were measured and analyzed. As a result of measurement, the effects caused by directivity of sound beam from curved array were founded. To remove these effects, we developed and applied the correction model. The proposed system is useful to evaluate characteristics of the acoustical output power of array probe.

Design and Evaluation of Ultrasonic Flow Meter for High Temperature by Using Finite Element Method (유한요소법을 이용한 고온용 초음파 유량센서의 설계 및 평가)

  • Lee, Joo-Hee;Kim, Chang-Il;Paik, Jong-Hoo;Cho, Jeong-Ho;Jeong, Young-Hun;Lee, Young-Jin;Nahm, Sahn
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.11
    • /
    • pp.859-864
    • /
    • 2011
  • An operation temperature of $Pb(Zr,Ti)O_3$ based piezoelectric ultrasonic flowmeter was generally restricted to below 200$^{\circ}C$ due to a low depoling temperature of its ceramic material. Thus, a new designed piezoelectric ultrasonic flowmeter was fabricated in order to protect from the extremely hot fluid. Its structure is optimized by a finite element method to effectively stop heat flowing along a waveguide. Various materials such as Cu, Al, SUS were examined as a multi-plate radiation shield to enhance the performance of piezoelectric ultrasonic flowmeter. The SUS was evaluated as the most effective material to enhance the performance of piezoelectric ultrasonic flowmeter. As the number of plates of the radiation shield increased, the temperature at piezoelectric transducer away from the hot fluid was constantly decreased with a ratio of 3.12$^{\circ}C$ per the plate number.

A Study on the Underwater Communication system of Ultrasonic Transducer (초음파 센서를 이용한 수중통신기에 관한 연구)

  • Kim, Dong-Hyun;Oh, Seung-Jae;Hwang, Hyun-Suk;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.168-171
    • /
    • 2000
  • Underwater acoustic communications have made considerable advances in the past decade. The purpose of this paper is to achieve the underwater communication by ultrasonic sensors and to investigate conditions of good underwater acoustic communicators. As a result of this experiments, the ultrasonic sensors, MA40E7R/S, made by Nicera can be used as ultrasonic transducers for underwater communication using AM(Amplitude Modulation) signal and Transmission Loss is 17.328[dB] at 65[cm]. To make a good underwater communicator, proper diameter of disk PZT transduers is the one of most important factors, because radiation of acoustic wave depends on proper diameter of transduers and the transmission loss strongly depends on the spreading loss.

  • PDF

A Study on Ultrasonic Sould-fields for Cleaning in a Pipe (관 내 세정을 위한 초음파 음장 연구)

  • Lee, Jung-Gu;Kim, Jin-Oh
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.5 s.98
    • /
    • pp.564-570
    • /
    • 2005
  • This paper presents some results of research for applying ultrasonic cleaning to an interior wall of cylindrical pipe. As the cleaning is achieved better for higher sound pressure, ultrasonic sound field in a cylindrical container is considered. The paper identifies nonuniform sound field established by the radiation of a cylindrical transducer driven at resonant frequency, Numerical analysis predicts the sound pressure distribution, and experiment verifies the trend of analysis results. Experiment observes the cleaning effect, and this paper suggests the possibility of using a cylindrical ultrasonic cleaning device.

Ultrasonic Backward Radiation on Randomly Rough Surface (무작위로 거친 표면에서의 후방복사 초음파)

  • Kwon, Sung-D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.1
    • /
    • pp.9-14
    • /
    • 2005
  • The angular dependence(profile) of backward radiated ultrasound was measured for glass specimens with random surface roughness using ultrasonic goniometer that ran changes the incident angle continuously. It was concluded that the roughened region had greater acoustic impedance than the unperturbed region. The comparison of backward radiations showed that the amplitude of peak and the area of radiation profile were increased with surface roughness. It was suggested from the sensitive dependence of the profile area that the profile of backward radiation could be applied to in the nondestructive evaluation of sulfate region. Inclined C-scan technique with the transducer inclined at Rayleigh angle showed the reverse of luminosity and the high signal to noise ratio so that it provided high resolution.

Ultrasonic ranging technique for obstacle monitoring above reactor core in prototype generation IV sodium-cooled fast reactor

  • Kim, Hoe-Woong;Joo, Young-Sang;Park, Sang-Jin;Kim, Sung-Kyun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.776-783
    • /
    • 2020
  • As the refueling of a sodium-cooled fast reactor is conducted by rotating part of the reactor head without opening it, the monitoring of existing obstacles that can disturb the rotation of the reactor head is one of the most important issues. This paper deals with the ultrasonic ranging technique that directly monitors the existence of possible obstacles located in a lateral gap between the upper internal structure and the reactor core in a prototype generation IV sodium-cooled fast reactor (PGSFR). A 10 m long plate-type ultrasonic waveguide sensor, whose feasibility has been successfully demonstrated through preliminary tests, was employed for the ultrasonic ranging technique. The design of the sensor's wave radiating section was modified to improve the radiation performance, and the radiated field was investigated through beam profile measurements. A test facility simulating the lower part of the upper internal structure and the upper part of the reactor core with the same shapes and sizes as those in the PGSFR was newly constructed. Several under-water performance tests were then carried out at room temperature to investigate the applicability of the developed ranging technique using the plate-type ultrasonic waveguide sensor with the actual geometry of the PGSFR's internal structures.

Development of Ultrasonic Transducer System for Wireless Power Transfer Part 1 : Transmitter Development (무선 전력전송을 위한 초음파 트랜스듀서 시스템 개발 Part 1: 송신소자 개발)

  • Youm, Woo-Sub;Hwang, Gunn;Yang, Woo-Seok;Lee, Sung-Q
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.9
    • /
    • pp.845-852
    • /
    • 2012
  • Recently, wireless power transfer technology is ready to be commercialized in consumer electronics. It draws attention from not only experts but also public because of its convenience and huge market. However, previous technologies such as magnetic resonance and induction coupling have limited applications because of its short transfer distance compared to device size and magnetic intensity limitation on the safety of body exposure. As an alternative, ultrasonic wireless power transfer technology is proposed. The ultrasonic wireless power transfer system is composed of transmitter which converts electrical energy to ultrasonic energy and receiver which converts the ultrasonic energy to the electrical energy again. This paper is focused on the development of high energy conversion efficiency of ultrasonic transmitter. Optimal transfer frequency is calculated based on the acoustic radiation and damping effect. The transmitter is designed through numerical analysis, and is manufactured to match the optimal transfer frequency with the size of 100 mm diameter, 12.2 mm thickness plate. The energy conversion efficiency of about 13.6 % at 2 m distance is obtained, experimentally. This result is quite high considered with the device size and the power transfering distance.