고점성 바이오 디젤유의 분무미립화에 관한 연구 (A Study on the Atomization of a Highly Viscous Biodiesel Oil)

  • 주은선;정석용;강대운;김종천
    • 한국자동차공학회논문집
    • /
    • 제5권1호
    • /
    • pp.146-153
    • /
    • 1997
  • An experiment was conducted to figure out the atomization characteristics of a highly viscous biodiesel fuel with rice-barn oil applying and ultrasonic energy into it. A spray simulator for the droplet atomization, an ultrasonic system, and six different nozzles(3 pintle-type nozzles and 3 single hole-type nozzles) were made. To investigate effects of ultrasonic energy in a highly viscous liquid fuel, an immersion liquid method was used as a measurement method on droplet size distributions. It was found that the ultrasonic energy was effective for the atomization improvement of the rice-bran oil as a highly viscous biodiesel fuel and the factor나 such as the nozzle opening pressure, pin-edge angles, hole diameters, and collection distances affected the atomization of spray droplets.

  • PDF

PDPA에 의한 Pintle형 노즐의 미립화 특성실험 -식물유를 중심으로- (Atomization Characteristics Experiment of Pintle Type Nozzle by the PDPA)

  • 나우정;유병구;정진도
    • 에너지공학
    • /
    • 제7권1호
    • /
    • pp.17-23
    • /
    • 1998
  • 본 실험은 고점성 미강유의 액체 미립화를 향상시키기 위해 초음파 에너지를 적용하여 미립화 특성을 규명하고자 수행하였다. 식물유의 미립화 실험장치는 유사하게 1마력의 구동모터와 노즐을 장착할 수 있는 인젝터 및 소형분사 펌프 등으로 구성되어 있는 분사장치, 액적의 분산을 막기 위한 포집장치, 공급되는 연료에 초음파 진동을 가해주는 초음파 장치, 그리고 미립화 정도를 측정하기 위한 PDPA 시스템으로 구성되어 있다. 핀틀형 노즐에서 된끝각을 5$^{\circ}$ $10^{\circ}$ 15$^{\circ}$이며, 분사압력은 10, 13, 16 Mpa의 조건으로 실험하였다. 이 때 포집거리 300mm로 하였다. 노즐 분사 압력에 따른 분무 평균입경을 측정하기 위하여 노즐테스터를 대기압 상태에서 핀틀링 노즐의 스프링 크기를 조절하여 분무 평균입경(SMD)은 상용연료 공급장치 보다 초음파 연료공급 장치의 경우 Pintle형 노즐에서는 SMD를 기준으로 하여 10% 미립화 상승효율을 얻을 수 있었다. 따라서 본 실험에서는 초음파 진동에너지를 연료에 공급함으로써 고점성연료의 미립화 개선이 이루어지고 있음을 확인할 수 있었다.

  • PDF

초음파 가진을 이용한 2-유체 노즐의 효율 향상 (Improvement of the Efficiency of a Twin-fluid Nozzle using Ultrasonic Vibration)

  • 주은선;나우정;정진도;송민근;이경열
    • Journal of Biosystems Engineering
    • /
    • 제27권4호
    • /
    • pp.317-326
    • /
    • 2002
  • Characteristics of a twin-fluid spray with ultrasonic vibration were examined in order to obtain a high efficiency of cold-fog spray of the automatic pest control machine which has been widely used in protected horticulture recently. An electrostrictive vibrator of PZT BLT and a magnetostrictive $\pi$-type vibrator were used applied as the ultrasonic transducers with a frequency of 28 kHz. All experiments were conducted in 4 methods of spray ; a conventional spray method without ultrasonic forcing, an indirect vibration method with ultrasonic forcing, an improving-quality method by ultrasonic forced within liquid, and a combined-use method with both of the indirect vibration method and the improving quality method. It was found that the ultrasonic energy increased the atomization efficiency of spray droplets about 10% and especially much more in the case of the combined-use method.

고온 회전 척을 구비한 포토레지스트 Spray Coating 방법 및 장치 (The Method and Apparatus for Photoresist Spray Coating with High Temperature Rotational Chuck)

  • 박태규;김준태;김국진;석창길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.42-44
    • /
    • 2003
  • The paper presents the method and apparatus for conformal photoresist spray coating on the 3D structured substrate. The system consists of a high-temperature-rotational chuck, ultrasonic spray nozzle module, angle control module and nozzle moving module. The coating uniformity is acquired by controlling the moving speed of the ultrasonic spray nozzle across the substrate which is rotated constantly. To coat the photoresist conformally the spray angle of the nozzle and the temperature of the substrate are controlled during spray coating. The rotational chuck can be heated up by hot air or $N_2$. The photoresist (AZ1512) has been coated on the 3D structured wafer by spray coating system and the characteristics have been evaluated.

  • PDF

원자로 헤드 관통관 노즐 가동전 검사 수행 (Pre-Service Inspection for Reactor Vessel Penetration Nozzle)

  • 이동진;노익준;신건철;김해석;홍주열;최정권
    • 한국압력기기공학회 논문집
    • /
    • 제6권2호
    • /
    • pp.9-15
    • /
    • 2010
  • US NRC issued rulemaking of 10CFR50.55a to perform the Perservice and Inservice inspection for Reactor Vessel Head Penetration Nozzle of US Nuclaer plant. The rulemaking was required the EPRI Demonstration to verify the NDE technique performing special Ultrasonic examination. In order to meet this requirement, the UT and ECT procedures was demonstrated and the NDE personnel were qualified by EPRI. In this paper, the NDE technique and analysis method are described the Preservice inspection for the Palo Verde #1/2/3 Replacement Reactor Vessel Head Penetration Nozzle using the qualified procedures and personnel.

  • PDF

PbO량에 따른 저온소결 PMN-PNN-PZT 세라믹스의 유전 및 압전특성 (Piezoelectric and Dielectric Characteristics of Low Temperature Sintering PMN-PNN-PZT Ceramics According to the amount of PbO)

  • 류주현;이석태;김도형;이상호;김국진
    • 한국전기전자재료학회논문지
    • /
    • 제20권1호
    • /
    • pp.31-34
    • /
    • 2007
  • In this study, in order to develop multilayer ceramics vibrator for ultrasonic nozzle, PMN-PNN-PZT ceramics were fabricated using $Li_{2}CO_{3}-Na_{2}_CO_{3}$ as sintering aids and their piezoelectric and dielectric characteristics were investigated according to the amount of PbO. With increasing PbO contents, secondary phases were increased and phase structure was changed from tetragonal structure to rhombohedral structure and also electromechanical coupling factor was linearly decreased. At the composition ceramics with the sintering temperature of $870^{\circ}C$ and 1 mol% excess PbO, density, electromechanical coupling factor, dielectric constant, piezoelectric d constant and mechanical quality factor showed the optimum value of $7.879\;g/cm^{3}$, 0.55, 1149, 328 pC/N, 1224, respectively for multilayer ceramics vibrator application for ultrasonic nozzle.

초음파를 이용한 중수로내 칼란드리아관과 원자로 정지물질 주입관과의 간격 측정 (Ultrasonic Measurement of Gap between Calandria Tube and Liquid Injection Nozzle in CANDU Reactor)

  • 손석만;김태룡;이준신;이영희;박철훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.834-839
    • /
    • 2001
  • Calandria tube wrapping each pressure tube is one of the key structural components of CANDU reactor(Calandria) which is consisted of many pressure tubes containing nuclear fuel assemblies. As the Calandria tube(made of zirconium alloy) is sagging due to its thermal and irradiation creep during the plant operation, it possibly contacts with liquid injection nozzle crossing beneath the Calandria tube, which subsequently results in difficulties on the safe operation. It is therefore necessary to check the gap for the confirmation of no contacts between the two tubes, Calandria tube and liquid injection tube, with a proper measure during the life of plant. In this study, an ultrasonic measurement method was selected among several methods investigated. The ultrasonic device being developed for the measurement of the gap was introduced and its preliminary performance test results were presented here. The gap between LIN and CT at site was measured using by this ultrasonic device at site.

  • PDF

초음파에너지 조사 W/O type 유화연료의 제반특성에 관한 연구(I) - 안정성 및 분무특성을 중심으로 - (A Study on the Various Characteristics of Ultrasonic-Energy-Added W/O Type Emulsified Fuel ( I ) - attaching importance to stability and spray characteristics -)

  • 김용철;송용식;류정인
    • 한국분무공학회지
    • /
    • 제9권3호
    • /
    • pp.22-28
    • /
    • 2004
  • This study is concerned about the characteristics of ultrasonic-energy-added W/O type emulsified fuel. The distilled water was mixed with diesel oil by using ultrasonic energy fuel feeding system and then the SMD of sprayed droplets was measured to find out atomization characteristics of emulsified fuel by using the Malvern 2600 system. The capacitance value was measured to verify stability of the same specimen by using the digital LCR meter, EDC1630 additionally. The main results are as follows; 1) The more measuring distance increases between one hole nozzle tip and analyser bearm, the more SMD increases. 2) The more water content increases, the more capacitance value increases depending on the time. Main Parameters of the study are the amount of water content $0{\sim}30%$ by 5% in emulsified fuel, and the measurement distance, $20{\sim}140mm$ by 10mm or 20mm between nozzle tip and analyser beam.

  • PDF

원자로 입출구 노즐 Alloy 82/182 이종금속 용접부 Weld Inlay 적용 후 초음파나노표면개질이 잔류응력 완화에 미치는 영향 (The effect of ultrasonic nano crystal surface modification for mitigation of the residual stress after weld inlay on the alloy 82/182 dissimilar metal welds of reactor vessel in/outlet nozzles)

  • 조홍석;박익근;정광운
    • Journal of Welding and Joining
    • /
    • 제33권2호
    • /
    • pp.40-46
    • /
    • 2015
  • This study was performed to investigate the effect of ultrasonic nano crystal surface modification (UNSM) on residual stress mitigation after Weld Inlay repair for butt dissimilar metal weld with Alloy 82/182 in reactor vessel In/Outlet nozzle. As-welded and Weld Inlay specimens were made in accordance with design standard of ASME Code Case N-766, and two planes of their weld specimens were peened by the optimum UNSM process condition. Peening characteristics for weld specimens after UNSM treatment were evaluated by surface roughness and Vickers hardness test. And, residual stress for weld specimens developed from before and after UNSM treatment was measured and evaluated by instrumented indentation technique. Consequently, it was revealed that the mitigation of residual stress in weld metal after Weld Inlay repair of reactor vessel In/Outlet nozzle could be possible through UNSM treatment.

분사노즐 형상에 따른 유화연료의 분무 미립화 및 물성 (Atomization Characteristics for Various Injection Nozzle Type and Property Changes)

  • 김용국;류정인
    • 한국자동차공학회논문집
    • /
    • 제18권4호
    • /
    • pp.62-67
    • /
    • 2010
  • The objective of this experimental study is to verify atomization characteristics of emulsified fuel. The emulsified fuel made of adding the ultrasonic energy is analyzed with atomization characteristics and chemicophysics. As water contents within emulsified fuel and needle angle increase, SMD, viscosity and surface tension were analyzed. By measuring the distribution percentage of hydrogen volume by $^1H$-NMR spectrum, the proportion of aromatics and paraffins is analyzed and compared each other. The results of study is as follows. First, as water contents within emulsified fuel and needle angle of nozzle increases, SMD increases. Second, for the distribution percentage of hydrogen volume, the distribution percentage of aromatics is about 10% and the rest portion is paraffins.