• 제목/요약/키워드: ultrasonic monitoring

검색결과 237건 처리시간 0.021초

Detection of the Ultrasonic Signals due to Partial Discharges in a 154kV Transformer

  • Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Hee-Ro
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제2C권6호
    • /
    • pp.297-303
    • /
    • 2002
  • We have developed an on-line ultrasonic detector to monitor partial discharge in an operating transformer. The ultrasonic sensor has 150[KHz] resonance frequency and contains a pre-amplifier with 60[㏈] gain. The on-line ultrasonic detector has 50~300[KHz] frequency band-pass filter to remove electrical and mechanical noises from the transformer. This detector has an ultrasonic signal discrimination algorithm which discriminates ultrasonic signals due to partial discharge in a transformer. A moving average method of ultrasonic signal number was employed to effectively monitor the increasing trend of the partial discharge. This paper describes an experience of partial discharge detection in a 154[㎸] operating transformer using an ultrasonic detector. With regards to gas analysis in oil, C2H2 gas was produced with a warning level in this transformer We detected ultrasonic signals on the transformer steel wall, and estimated the position of partial discharge. With further inspection, we found carbonized marks due to partial discharge on the supporting bolt which fastens the windings.

아두이노 기반의 효율적인 홈 시큐리티 모니터링 시스템 설계 및 구현 (Design and Implementation of Arduino-based Efficient Home Security Monitoring System)

  • 이형로;인치호
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권2호
    • /
    • pp.49-54
    • /
    • 2016
  • 본 논문에서는 아두이노 기반의 효율적인 홈 시큐리티 모니터링 시스템을 제안한다. 제안하는 홈 시큐리티 모니터링 시스템은 비교적 가격이 저렴한 메인 프로세서인 아두이노와 초음파 센서, 인체 감지 센서를 이용하여 침입여부를 판단하도록 홈 시큐리티 시스템을 구성하였고, 초음파 센서와 인체 감지 센서의 데이터는 아두이노에 연결된 이더넷 쉴드를 통해 웹 서버로 전송하도록 설계하였다. 그리고 웹 서버에서는 저장된 초음파 센서와 인체 감지 센서 데이터를 이용하여 침입여부를 확인하고, JQuery를 이용하여 연결되어 있는 웹캠으로 스냅 샷을 촬영하도록 하였으며, 촬영 된 스냅 샷은 웹 서버에 이미지 파일로 저장되며, HTML5와 CSS, Canvas를 사용하여 사용자는 웹 또는 스마트 디바이스 환경에서 모니터링이 가능하도록 설계하였다. 제안된 홈 시큐리티 모니터링 시스템을 실제 구현함으로서 효율성 검증 결과 기존 홈 시큐리티 시스템에 비해 구성이 쉬워 도면을 보고 쉽게 제작이 가능하였으며, 아두이노를 이용하여 구성과 설치비에 대한 가성비가 뛰어났고, 개인이 오류에 대한 직접적인 대처가 가능해 비용에 대한 효율성과 편리성을 입증하였으며, 신뢰도 높은 데이터를 이용하여 안정적인 시스템 운영이 가능하였다.

초음파를 이용한 기체 유동장내 분진 모니터링 (Particle Monitoring Using Ultrasound in the Gas Flow)

  • 장경영;김주철;김홍준;황원호
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.78-85
    • /
    • 2004
  • The particle amount monitoring technique using ultrasound is proposed to determine the proper maintenance time of the filter in the supply process of pure gas in the unit of oxygen plant. There are advantages that it is adaptable in high temperature and high pressure, and it is not disturbed by being exposed in the gas flow, and it can be implemented very economically. The applicability of the ultrasonic technique is pre-studied through the theoretical analysis for the dependency of attenuation of ultrasonic wave on the particles in the gas flow. For the purpose, absorption, scattering and dispersion models are considered, and the attenuation by absorption and the change rate of the propagation speed are calculated fur the specific range of particle size and the ultrasonic wave frequency. It was expected by simulation that the absorptive attenuation by particles was the most sensitive to the change of particle amount. The experimental result showed high correspondence with the theoretical expectation so that this ultrasound attenuation measurement was proved to be highly effective for monitoring the amount of floating particles in the gas flow.

Multi-resolution bolt preload monitoring based on the acoustoelastic effect of ultrasonic guided waves

  • Fu, Ruili;Mao, Ruiwei;Yuan, Bo;Chen, Dongdong;Huo, Linsheng
    • Smart Structures and Systems
    • /
    • 제30권5호
    • /
    • pp.513-520
    • /
    • 2022
  • During the long-time service of a bolt, its preload may suffer slight perturbations or significant reductions. It is a dilemma to monitor preload changes at high resolution and full scale. Approaches for bolt preload monitoring with multi-resolution should be developed. In this paper, a simple and effective multi-resolution bolt preload monitoring approach using ultrasonic guided waves (UGW) is proposed. A linear relationship between the time-of-flight (TOF) variation of multi-reflected waves and preload is derived to theoretically reveal the multi-resolution properties of UGW. The variations of TOF before and after the slight preload perturbations are extracted by using a global evaluation method. Experimental results show that the signal-to-noise ratio (SNR) of the 1st, 2nd, and 3rd-reflected UGWs is larger than 20 dB. The resolution of the 2nd-reflected UGW is higher than that of the 1st-reflected UGW and lower than that of the 3rd-reflected UGW. The ultimate detectable resolutions of bolt preload (DRBP) of the 1st and 3th-reflected UGWs are 0.9% and 0.5%, respectively. By using the 1st and 3th-reflected guided waves, the bolt looseness with different degrees can be monitored simultaneously.

초음파센서를 이용한 하천 수위/유속 측정 시스템 (River level/velocimetry measuring system using the ultrasonic sensor)

  • 박희석;박찬원
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.249-255
    • /
    • 2006
  • In this paper, we study the river level/velocimetry measuring system using the ultrasonic sensor to acquire the more precise data from the river circumstance in rainy season. We design the two ultrasonic sensor system to calculate the water level and surface current speed of the river using the dedicated hardware and software. We investigate the validity and effectiveness of the proposed system which applied to the real river environment monitoring system that will be extended to the GIS.

  • PDF

초음파 측정에 의한 베어링손상 평가 (Assessment of Bearing Damage by Ultrasonic Measurement)

  • 이상국;이인철
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.395-400
    • /
    • 2004
  • For the purpose of monitoring by ultrasonic test of the ball bearing conditions in rotating machinery, a system for their diagnosis was developed. ultrasonic technique is used to detect abnormal conditions in the bearing system. And various data such as frequency spectrum, energy and amplitude of ultrasonic signals, and ultrasonic parameters were acquired during experiments with the simulated ball bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was established. Bearing diagnosis system is composed of four parts as follows : sensing part for ultrasonic sensor and preamplifier, signal processing part for measuring frequency spectrum, energy and amplitude, interface part for connecting ultrasonic signal to PC using A/D converter, graphic display and software part for display of bearing condition and for managing of diagnosis program.

  • PDF

EXPERIMENTAL STUDY ON THE CHARACTERISTICS OF RIVERBED MATERIALS USING AN ULTRASONIC SENSOR

  • Yeo, Woon-Kwang;Jang, Bok-Jin;Lee, Jong-Kook;Kim, Young-Bin
    • Water Engineering Research
    • /
    • 제7권1호
    • /
    • pp.21-28
    • /
    • 2006
  • The scouring process is complex and subject to many factors. Recently, experiments for real-time bridge scour monitoring have been active as means for a more reliable scour prediction. Riverbed materials are an important factor in bridge scouring; therefore, an accurate estimation of riverbed material is critical in predicting a scour. As a part of this approach, an ultrasonic sensor, which can not only detect river bottom during floods but can also be installed lose to the underwater structures, was developed. This sensor is able to map the river bottom using an ultrasonic waves with the characteristics of the returning wave, reflected from an object or bottom ground. The reflected wave is unique according to the situations, or materials below. Therefore, it would be possible to identify the consisting materials of a riverbed if we could reveal each characteristic in the received signals. In this study, a preliminary experiment was performed in the laboratory to identify and classify received signals, which is unique to each material. The analysis of this experiment gives the graph, which makes it possible to identify materials of the river bottom through the ultrasonic signals. The proposed graph was verified through a comparison with the actual field data measured in river.

  • PDF

Non-contact damage monitoring technique for FRP laminates using guided waves

  • Garg, Mohit;Sharma, Shruti;Sharma, Sandeep;Mehta, Rajeev
    • Smart Structures and Systems
    • /
    • 제17권5호
    • /
    • pp.795-817
    • /
    • 2016
  • A non-contact, in-situ and non-invasive technique for health monitoring of submerged fiber reinforced polymers (FRP) laminates has been developed using ultrasonic guided waves. A pair of mobile transducers at specific angles of incidence to the submerged FRP specimen was used to excite Lamb wave modes. Lamb wave modes were used for comprehensive inspection of various types of manufacturing defects like air gaps and missing epoxy, introduced during manufacturing of FRP using Vacuum Assisted Resin Infusion Molding (VARIM). Further service induced damages like notches and surface defects were also studied and evaluated using guided waves. Quantitative evaluation of transmitted ultrasonic signal in defect ridden FRPs $vis-{\grave{a}}-vis$ healthy signal has been used to relate the extent of damage in FRPs. The developed technique has the potential to develop into a quick, real time health monitoring tool for judging the service worthiness of FRPs.

Noncontact techniques for monitoring of tunnel linings

  • White, Joshua;Hurlebaus, Stefan;Shokouhi, Parisa;Wittwer, Andreas;Wimsatt, Andrew
    • Structural Monitoring and Maintenance
    • /
    • 제1권2호
    • /
    • pp.197-211
    • /
    • 2014
  • An investigation of tunnel linings is performed at two tunnels in the US using complimentary noncontact techniques: air-coupled ground penetrating radar (GPR), and a vehicle-mounted scanning system (SPACETEC) that combines laser, visual, and infrared thermography scanning methods. This paper shows that a combination of such techniques can maximize inspection coverage in a comprehensive and efficient manner. Since ground-truth is typically not available in public tunnel field evaluations, the noncontact techniques used are compared with two reliable in-depth contact nondestructive testing methods: ground-coupled GPR and ultrasonic tomography. The noncontact techniques are used to identify and locate the reinforcement mesh, structural steel ribs, internal layer interfaces, shallow delamination, and tile debonding. It is shown that this combination of methods can be used synergistically to provide tunnel owners with a comprehensive and efficient approach for monitoring tunnel lining conditions.

섬유강화 복합재료의 비접촉식 초음파 평가 기법 연구 (A Study of Non-contacting Ultrasonic Technique for Evaluation of Fiber Reinforced Composite Materials)

  • 최상우;서경철;이준현;변준형
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 추계학술발표대회 논문집
    • /
    • pp.268-271
    • /
    • 2004
  • Non-contact technique should be developed for receiving ultrasonic wave for on-line monitoring of processing defects of fiber reinforced composites, since couplant must be applied on composite materials when conventional ultrasonic testing technique was used. Restriction of conventional ultrasonic testing technique was proven by transmitting and receiving ultrasonic wave on CFRP in various direction of wave propagation with various incident angle of ultrasonic beam. Air-coupled transducer and laser interferometer were applied for non-contacting reception of ultrasonic wave in fiber reinforced composite materials. Air-coupled transducer has optimal sensitivity and frequency band of 300kHz has homogeneous characteristics on direction of wave propagation.

  • PDF