• 제목/요약/키워드: ultrasonic field analysis

검색결과 104건 처리시간 0.027초

위상배열기법을 이용한 치아결함 초음파이미지 진단기술개발 (A Study on Ultrasonic Image Diagnosis Methods of Tooth Defect with Phased-Array Techniques)

  • 오윤정;황인남;박수정;임광희;조현준;조영태
    • 한국생산제조학회지
    • /
    • 제18권6호
    • /
    • pp.604-613
    • /
    • 2009
  • Recently, researches to develop phased array ultrasonic examination techniques are proceeded to diagnose dental caries and the status of surgical operation of dental implant. Sound field analysis of phased array ultrasonic transducers were carried out in order to characterizing the ultrasonic phased array beams. The sound field of ultrasonic radiation was calculated for the sample called "gypsum-improved stone" with the similar characteristics of dental materials. Industrial phased array ultrasonic devices were utilized for the insptriion of the artificial flaws machined in the gypsum-improved stone. Dental implants were made at the pig jaw bone and defect images were confirmed for the dental implants.

  • PDF

관 내 세정을 위한 초음파 음장 연구 (A Study on Ultrasonic Sould-fields for Cleaning in a Pipe)

  • 이정구;김진오
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.564-570
    • /
    • 2005
  • This paper presents some results of research for applying ultrasonic cleaning to an interior wall of cylindrical pipe. As the cleaning is achieved better for higher sound pressure, ultrasonic sound field in a cylindrical container is considered. The paper identifies nonuniform sound field established by the radiation of a cylindrical transducer driven at resonant frequency, Numerical analysis predicts the sound pressure distribution, and experiment verifies the trend of analysis results. Experiment observes the cleaning effect, and this paper suggests the possibility of using a cylindrical ultrasonic cleaning device.

음선 기법을 이용한 초음파 음장 해석 (Ultrasonic Field Analysis Using a Sound-Ray Method)

  • 문병환;김진오
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1329-1334
    • /
    • 2001
  • This paper deals with the application of a sound-ray method to the analysis of the sound field in an ultrasonic cleaner. In order to include the wave interference phenomenon, the method has been modified to consider the phase of sound rays, The improved algorithm has been implemented by developing a Visual C++ program, The algorithm has been verified by comparing the analysis results of BEM reported earlier. It has been shown that the algorithm can be used to calculate ultrasonic fields in a cleaning- container with an object to be cleaned.

  • PDF

PIV 계측에 의한 고주파수 초음파 유동장 해석에 관한 연구 (A Study on the Flow Field Analysis with a High-frequency Ultrasonic by PIV Measurement)

  • 이상범;송민근;손승우;정광수;주은선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.727-732
    • /
    • 2001
  • The purpose of this study is to compare the time mean velocity distribution, the time mean kinetic energy, and the time mean turbulence intensity between vertical and horizontal flow fields in a coaxial circular pipe by PIV measurement. Experiments are performed at a Reynolds number 2,000, measuring regions divided as the section regions A, B, C, D in flow fields. The angle of the high-frequency ultrasonic is selected in the direction of $45^{\circ}$ to the flow axes and it is reflected several times. In results, it is clarified that the effect of gravity is given in the vertical flow field compared with the horizontal flow field and the ultrasonic affects the turbulence enhancement. And kinetic energy and turbulence intensity with ultrasonic are shown slightly bigger than those in flow field without it.

  • PDF

초음파를 이용한 물체 부상 이송시스템의 진동 특성 해석 (An Analysis of Vibration Characteristics in Ultrasonic Object Levitation Transport System)

  • 정상화;김현욱;최석봉;김광호;박준호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.415-418
    • /
    • 2005
  • In the semiconductor and optical industry, a new transport system which can replace the conventional transport systems is required. The transport systems are driven by the magnetic field and conveyer belts. The magnetic field may damage semiconductor and the contact force may scratch the optical lens. The ultrasonic wave driven system can solve these problems. In this semiconductor and optical industry, the non-contact system is required fur reducing the damages. The ultrasonic transportation is the solution of the problem. In this paper, the ultrasonic levitation system fur levitating object are proposed. The 3D vibration profiles of the beam are measured by Laser scanning Vibrometer fur verifying the vibration characteristics of the system and the amplitudes of the beam and the levitation heights of object are measured for evaluating the performance.

  • PDF

전립선암의 온열치료를 위한 초음파변환기 개발에 관한 연구 (A study for implementation of ultrasonic transducer in the prostate cancer hyperthermia)

  • 박문규;노시철;박재현;최흥호
    • 센서학회지
    • /
    • 제18권5호
    • /
    • pp.377-384
    • /
    • 2009
  • The ultrasonic hyperthermia for oncology has been developed and studied. The HIFU(high intensity focused ultrasound) is the most recent method to treat the tumor by using ultrasound. In this study, an insertion-type transducer for treating a prostate cancer, which can focus the ultrasonic beam mechanically and electrically, was designed and developed. The developed transducer was composed of three arrays, and each array has 32 elements. For the purpose of the mechanical focusing, both side arrays are slanted to the center array by $15^{\circ}$. With this structure, NFL(near field length) was set up as 30 mm. The PZT-4 and two matching layers were used, and the backing layer was excepted to prevent energy losses. The acoustic field analysis and the heating test were performed to evaluate the performance of developed transducer. The shape of an acoustic field, peak pressure, and acoustic pressure distribution were compared with numerical simulation. The NFL was 32 mm, the beam width was 5 mm, focal area was $40\;mm^2$, and peak pressure was 5.5 MPa. With heating by using developed transducer, the temperature increased up to $33^{\circ}C$ at focal zone. As a result of this study, the usefulness of suggested transducer for prostate cancer hyperthermia was confirmed by the acoustic field analysis and the heating test with TMM(tissue mimicking) phantom.

Flow Field Analysis for Ultrasonic Flow Meter

  • OSHIMA Yuko;TAKAMIYA Toshiyuki;ITO Shigeyuki
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.209-209
    • /
    • 2003
  • PDF

가상 3D 그래픽을 이용한 집속형 초음파 탐촉자 성능평가 방법 (New Performance Evaluation Method of Focused Ultrasonic Transducers By Using Virtual 3D Graphic)

  • 이순흠;최관순;김동식
    • 정보처리학회논문지B
    • /
    • 제14B권6호
    • /
    • pp.407-412
    • /
    • 2007
  • 초음파 의료 영상기기나 산업용 초음파 검사 시스템의 성능은 초음파 탐촉자의 성능에 의해 크게 좌우된다. 탐촉자의 성능 특성 정보는 보통 제작자가 제공하는 반사원의 초음파 R/F 신호와 주파수 특성에 의해 기술된다. 그러나 집속형 초음파 탐촉자의 경우, 두 자료로는 선명한 C-Scan 이미지를 얻을 수 있다는 것을 보증할 수는 없다. 그래서 집속형 초음파 탐촉자의 성능 평가를 위한 새로운 척도로 상대 초점크기 및 상대 유효초점영역의 모양을 제안한다. 상대 초점의 크기와 상대 유효초점영역의 모양은 쇠구슬로부터 획득된 초음파 R/F 신호를 가상 3차원 영상 복원 프로그램으로 처리하여 얻는다. 제시된 방법은 기존 자료로는 알 수 없었던 탐촉자 성능을 정확히 평가할 수 있었으며, 방법도 간단하여 실제 탐촉자 제작시 불/양품을 쉽게 가려 낼 수 있으며, 탐촉자 경년열화에 따른 성능 저하도 검출할 수 있는 장점을 갖는다. 결과적으로 초음파 영상기기나 산업용 초음파 검사 시스템의 성능을 담보할 수 있다.

금속 용착을 위한 초음파 가공용 한파장 스텝 혼의 설계 (One-wave Step Horn Design for Ultrasonic Machining for Metal Welding)

  • 백시영;장성민
    • 한국산학기술학회논문지
    • /
    • 제11권12호
    • /
    • pp.4735-4741
    • /
    • 2010
  • 초음파 금속 용착은 신소재, 도금 구조물 등과 같은 다양한 재료의 용착에 대한 가능성 때문에 광범위한 분야에서 사용되고 있으며 용착 조건도 다양하다. 본 연구에서는, 이종 금속 박판의 초음파 금속 용착을 위해 설계된 단부가형 한파장 혼은 유한요소해석 하였다. 유한유소해석은 초음파 혼의 최적 설계와 초음파 공구혼의 고유 주파수를 예상하기 위해 사용되었다. 그리고 설계된 한파장 스텝 혼은 고유 주파수 분석 시스템을 사용하여 실험적으로 검증하였다.

초음파 물체부상 이송시스템의 Flexural Beam 설계 (Flexural Beam Design of Ultrasonic Object Levitation Slide System)

  • 정상화;김현욱;최석봉;김광호;박준호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.959-962
    • /
    • 2005
  • In the semiconductor and optical industry. a new transport system which can replace the conventional transport system is required. The Transport systems are driven by the magnetic field and conveyer belts. The magnetic field may damage semiconductor and the contact force may scratch the optical lens. The ultrasonic wave driven system can solve these problems. In this semiconductor and optical industry, the non-contact system is required for reducing the damages. The ultrasonic transportation is the solution of the problem. In this paper, the ultrasonic levitation system for levitation object are proposed. The 3D vibration profiles of the beam are measured by Laser Scanning Vibrometer for verifying the vibration characteristics of the system and the amplitudes of the beam and the levitation heights of object are measured fore evaluating the performance.

  • PDF