• Title/Summary/Keyword: ultra-precision

Search Result 923, Processing Time 0.031 seconds

Adaptive Multi-target Estimation Algorithm in an IR-UWB Radar Environment (IR-UWB 레이더 환경에서 적응형 다중 목표물 추정 알고리즘)

  • Yeo, Bong-Gu;Lee, Byung-Jin;Kim, Sueng-Woo;Youm, Mun-Jin;Kim, Kyung-Seok
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.4
    • /
    • pp.81-88
    • /
    • 2016
  • In this paper, we propose an adaptive multi-target estimation algorithm using the characteristics of signals in the IR-UWB(Impulse-Radio Ultra Wideband) radar system, which is attracting attention because it has good transparency, robustness to the indoor environment, and high precision positioning of tens of centimeters. We proposed an algorithm that estimates multiple peaks with the characteristic that the signal reflected by the target has a peak. To verify the performance of these algorithms, multiple targets were placed in front of the radar and the existing technique and the multi - target estimation algorithm were compared. The location of the targets is estimated in real time with one transmitting antenna and one receiving antenna. The number of estimates can be increased compared with the existing peak signal derivation method, and multiple targets can be derived. The conventional technique estimates only one target, which results in a mean square error of 1 while a multi - target estimation algorithm yields a result of about 0.05. The proposed method is expected to be able to apply multiple targets to the estimation and application in one IR-UWB module environment.

Design and Implementation of Wideband Ultra-Fast High Precision Frequency Synthesizer for ELINT Equipment (ELINT 장비용 광대역 초고속 고정밀 주파수 합성기 설계 및 구현)

  • Lee, Kyu-Song;Jeon, Kye-Ik;Oh, Seung-Hyeub
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.11
    • /
    • pp.1178-1185
    • /
    • 2009
  • In this paper, a wideband ultra-high speed & high purity discrete frequency synthesizer having minimum 2.5 MHz step size was proposed. To achieve fast and wideband operation, discrete frequencies were synthesized by mixing of 3 different pre-synthesized 16 frequencies made from fixed PLL and frequency dividers. Frequencies with discrete 2.5 MHz step were produced in 710~1,610 MHz. The measured hopping response time was 350 nsec average, output level was 21.5 dBm average with 2.65 dB flatness, spurious and harmonics level were suppressed below -60 dBc, and phase noise was -94 dBc/Hz@100 Hz. Also, a new measurement method for synthesizer response time was described.

Experimental studies of homogeneity and stability honeybee venom using ultra-high performance liquid chromatography (주사제 사용을 위한 봉독의 균질성 및 안정성 평가)

  • Han, Sang Mi;Kim, Se Gun;Hong, In Phyo;Woo, Soon Ok;Jang, Hye Ri;Lee, Kyung Woo
    • Korean Journal of Veterinary Service
    • /
    • v.39 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Honeybee venom (BV) from Apis mellifera L. has been used as natural antimicrobial compounds in pigs, cows, dairy cattle and chicken farms in Korea. The purpose of this study was conducted to confirm homogeneity and stability of BV dissolved with distilled water or saline solution. Melittin was analyzed with ultra-high performance liquid chromatography (UPLC) for BV to secure the validation of analysis. BV at concentration of 1 mg/mL was dissolved with distilled water or saline solution at room temperature. Homogeneity of BV dissolved with distilled water or saline solution at upper, milddle, and lower layers all satisfied the accuracy and precision criteria. Stability of BV dissolved with distilled water or saline solution for 7 days all satisfied the criterion both light and dark storage condition. BV has satisfied with homogeneity and stability in distilled water or saline solution at room temperature under light or dark condition. The results of this study suggest that BV has a possibility as the substitute of natural antimicrobial agents for the animal drugs and feed additives.

Precise Measurement of Ultra Small Retardation of Rubbed Polyimide Alignment Layer Using an Improved Transmission Ellipsometer (개선된 투과형 타원계를 사용한 러빙된 Polyimide 배향막의 초미세 위상지연 정밀 측정)

  • Lyum, Kyoung Hun;Park, Sang Uk;Yang, Seong Mo;Yoon, Hee Kyu;Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.2
    • /
    • pp.77-85
    • /
    • 2013
  • The precision of retardation measurement has been improved upto $3{\sigma}$ <0.005 nm after improvements are made to the conventional transmission ellipsometer. Improvements are made such that, i) the polarizer module instead of the sample stage is rotated, ii) the light source is replaced, iii) the starting points of two rotating modules are accurately synchronized, and iv) the fine background retardation is compensated. Together with the newly introduced RVD (Retardation Vector Difference) method, the improved instrument is successfully applied to characterize the ultra small optical birefringence of the rubbed polyimide alignment layer, after the residual retardation due to glass substrate whose magnitude is about 1.0 nm is properly subtracted. It is verified that the net retardation of the alignment layer ranges from 0.05 nm to 0.15 nm.

Electrical characteristics of SiC thin film charge trap memory with barrier engineered tunnel layer

  • Han, Dong-Seok;Lee, Dong-Uk;Lee, Hyo-Jun;Kim, Eun-Kyu;You, Hee-Wook;Cho, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.255-255
    • /
    • 2010
  • Recently, nonvolatile memories (NVM) of various types have been researched to improve the electrical performance such as program/erase voltages, speed and retention times. Also, the charge trap memory is a strong candidate to realize the ultra dense 20-nm scale NVM. Furthermore, the high charge efficiency and the thermal stability of SiC nanocrystals NVM with single $SiO_2$ tunnel barrier have been reported. [1-2] In this study, the SiC charge trap NVM was fabricated and electrical properties were characterized. The 100-nm thick Poly-Si layer was deposited to confined source/drain region by using low-pressure chemical vapor deposition (LP-CVD). After etching and lithography process for fabricate the gate region, the $Si_3N_4/SiO_2/Si_3N_4$ (NON) and $SiO_2/Si_3N_4/SiO_2$ (ONO) barrier engineered tunnel layer were deposited by using LP-CVD. The equivalent oxide thickness of NON and ONO tunnel layer are 5.2 nm and 5.6 nm, respectively. By using ultra-high vacuum magnetron sputtering with base pressure 3x10-10 Torr, the 2-nm SiC and 20-nm $SiO_2$ were successively deposited on ONO and NON tunnel layers. Finally, after deposited 200-nm thick Al layer, the source, drain and gate areas were defined by using reactive-ion etching and photolithography. The lengths of squire gate are $2\;{\mu}m$, $5\;{\mu}m$ and $10\;{\mu}m$. The electrical properties of devices were measured by using a HP 4156A precision semiconductor parameter analyzer, E4980A LCR capacitor meter and an Agilent 81104A pulse pattern generator system. The electrical characteristics such as the memory effect, program/erase speeds, operation voltages, and retention time of SiC charge trap memory device with barrier engineered tunnel layer will be discussed.

  • PDF

Experimental Implementation of Continuous GPS Data Processing Procedure on Near Real-Time Mode for High-Precision of Medium-Range Kinematic Positioning Applications (고정밀 중기선 동적측위 분야 응용을 위한 GPS 관측데이터 준실시간 연속 처리절차의 실험적 구현)

  • Lee, Hungkyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.31-40
    • /
    • 2017
  • This paper deals with the high precision of GPS measurement reduction and its implementation on near real-time and kinematic mode for those applications requiring centimeter-level precision of the estimated coordinates, even if target stations are a few hundred kilometers away from their references. We designed the system architecture, data streaming and processing scheme. Intensive investigation was performed to determine the characteristics of the GPS medium-range functional model, IGS infrastructure and some exemplary systems. The designed system consisted of streaming and processing units; the former automatically collects GPS data through Ntrip and IGS ultra-rapid products by FTP connection, whereas the latter handles the reduction of GPS observables on static and kinematic mode to a time series of the target stations' 3D coordinates. The data streaming unit was realized by a DOS batch file, perl script and BKG's BNC program, whereas the processing unit was implemented by definition of a process control file of BPE. To assess the functionality and precision of the positional solutions, an experiment was carried out against a network comprising seven GPS stations with baselines ranging from a few hundred up to a thousand kilometers. The results confirmed that the function of the whole system properly operated as designed, with a precision better than ${\pm}1cm$ in each of the positional component with 95% confidence level.

A Problematic Bubble Detection Algorithm for Conformal Coated PCB Using Convolutional Neural Networks (합성곱 신경망을 이용한 컨포멀 코팅 PCB에 발생한 문제성 기포 검출 알고리즘)

  • Lee, Dong Hee;Cho, SungRyung;Jung, Kyeong-Hoon;Kang, Dong Wook
    • Journal of Broadcast Engineering
    • /
    • v.26 no.4
    • /
    • pp.409-418
    • /
    • 2021
  • Conformal coating is a technology that protects PCB(Printed Circuit Board) and minimizes PCB failures. Since the defects in the coating are linked to failure of the PCB, the coating surface is examined for air bubbles to satisfy the successful conditions of the conformal coating. In this paper, we propose an algorithm for detecting problematic bubbles in high-risk groups by applying image signal processing. The algorithm consists of finding candidates for problematic bubbles and verifying candidates. Bubbles do not appear in visible light images, but can be visually distinguished from UV(Ultra Violet) light sources. In particular the center of the problematic bubble is dark in brightness and the border is high in brightness. In the paper, these brightness characteristics are called valley and mountain features, and the areas where both characteristics appear at the same time are candidates for problematic bubbles. However, it is necessary to verify candidates because there may be candidates who are not bubbles. In the candidate verification phase, we used convolutional neural network models, and ResNet performed best compared to other models. The algorithms presented in this paper showed the performance of precision 0.805, recall 0.763, and f1-score 0.767, and these results show sufficient potential for bubble test automation.

Development of Quantitative Analytical Method for Isoflavonoid Compounds from Fruits of Cudrania Tricuspidata (꾸지뽕나무 열매 isoflavonoid 화합물에 대한 정량분석법 개발)

  • Yoon, Sun Young;Kim, Seok Ju;Sim, Su Jin;Lee, Hak-Ju
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.337-349
    • /
    • 2016
  • In this study, an analytical method to evaluate the quality of isoflavonoid compounds purified and isolated from the fruits of Cudrania tricuspidata was developed and validated using Ultra Performance Liquid Chromatography (UPLC). The fruits of C. tricuspidata were extracted with methanol and further fractioned with n-hexane, ethyl acetate and water. The resulting ethyl acetate extract separated into four isoflavonoid compounds by a combination of silica gel and sephadex LH-20 column chromatography. The structures of the compounds were elucidated as alpinumisoflavone, 6,8-diprenyl genistein, 6,8-diprenyl orobol, 4'-O-methylalpinumisoflavone by various techniques such as UV-Vis, ESI-MS, $^1H\;NMR$ and $^{13}C\;NMR$ spectroscopy. Finally, a method to characterize the compounds was developed by using the UPLC equipped with a $C_{18}$ column and a gradient mobile phase system consisting of 2% acetic acid in water (solvent A) and 2% acetic acid in methanol (solvent B). The developed method was validated with the parameters such as selectivity, linearity, limit of detection, limit of quantitation, accuracy, and precision, which are defined by the ICH (International Conference on Harmonization). Using the validated method, the compounds in the fruits harvested in different months were also quantitatively analyzed. We propose this approach this approach can readily be utilized as an efficient evaluation method to quantify the extracts of C. tricuspidata.

Validation and Content Analysis of Putrescine in the Venom of Honeybee (Apis mellifera L.) (서양종꿀벌 일벌독에 함유된 putrescine 밸리데이션 및 함량 분석)

  • Choi, Hong Min;Kim, Hyo Young;Kim, Se Gun;Han, Sang Mi
    • Korean journal of applied entomology
    • /
    • v.60 no.3
    • /
    • pp.263-268
    • /
    • 2021
  • The venom of honeybees (Apis mellifera L.) is used to treat many diseases because of its anti-inflammatory and analgesic effects. Bee venom consists of several biologically active molecules and exhibits remarkable anti-cancer effects. However, biological amines, which exhibit diverse functionality such as anti-inflammatory and antibacterial effects, have not been previously reported in bee venom. In this study, we determined the content of putrescine in bee venom by using ultra-performance liquid chromatography. The specificity, accuracy, and precision of the assay were assessed, and the assay validated. The linearity of the putrescine assay was r ≥ 0.99, indicating a moderate level of putrescine in the bee venom. The limit of detection and limit of quantification were both 0.9 ㎍/mL, while the rate of recovery was 96.4%-99.9%. The relative standard deviation (RSD) of the intra-day precision and inter-day precision of the putrescine assay were 0.16% - 0.23% and 0.09% - 0.36%, respectively, with the RSD ≤ 5% indicating excellent precision. Thus, the linearity, limit of detection, limit of quantification, and recovery rate of the putrescine assay were satisfactory. The analysis of the bee venom showed that the putrescine content was 3.1 ± 0.09 mg/g. This study provides fundamental data on putrescine content in bee venom, which will prove useful in further studies of its bioactivity.

Water-Soluble Vitamins Contents in Seafood-Based Dishes (수산물 조리 식품에 함유된 수용성 비타민 함량)

  • Kim, Naeun;Kim, Younghwa
    • The Korean Journal of Food And Nutrition
    • /
    • v.33 no.4
    • /
    • pp.390-398
    • /
    • 2020
  • The purpose of this study was to determine the contents of water-soluble vitamins B1 (thiamine), B2 (riboflavin), B3 (niacin) and B12 (cyanocobalamin) in seafood-based dishes by using the high-performance liquid chromatography with the ultra violet and fluorescence detector. The vitamin B1, B2, B3 and B12 contents were analyzed in 29 seafood-based dishes. The method validation was performed on the method to determine the linearity, accuracy, limits of quantification, limits of detection and precision for vitamin B1, B2, B3 and B12. An excellent linearity range (R2=0.999~1.000) in the calibration curve for the water-soluble vitamins was observed. All analytical methods for the water-soluble vitamins showed the acceptable accuracy (89.4~119.7% recovery) and the precision (0.6~4.8% repeatability and 1.0~4.2% reproducibility). The highest content of vitamin B1 was 2.646 mg/100 g in the kkongchi-jorim, and the highest contents of vitamin B2, B3 and B12 were 0.370 mg/100 g, 10.971 mg/100 g, and 17.193 ㎍/100 g, respectively, in the kkongchi-gui. Our results provide reliable data on the contents of the water-soluble vitamins of seafood-based dishes in Korea.