• 제목/요약/키워드: tyre fire

검색결과 5건 처리시간 0.021초

타이어 화재 대응 소방관들의 휘발성유기화합물 노출 평가 (Firefighters' Exposure to Volatile Organic Compounds in Tyre Fire)

  • 김원;최인자;조영환;정혜영;권지운;이소연
    • 한국산업보건학회지
    • /
    • 제33권4호
    • /
    • pp.385-394
    • /
    • 2023
  • Objectives: Firefighters could be exposed to a range of toxic chemicals during firefighting. When tyre burns, various toxic chemicals including volatile organic compounds(VOCs) could be emitted. In this study, the researchers assessed the VOC exposure of firefighters during tyre fire suppression through biomonitoring. Methods: There was a big tyre fire on 12 March 2023. Of the responding firefighters, we recruited 14 participants to collect their urine after firefighting. One week later, researchers collected firefighters' urine again right after their off-duty period. We analyzed each metabolite of benzene, toluene, xylene, and styrene in urine and compared their exposure level based on sampling time. Results: The detection rate for metabolite of benzene, toluene, styrene, and xylene in urine sampled at each time was 43%-64%, 100%, 86%-100%, and 100%, respectively. Except for the benzene, metabolite levels measured in urine after firefighting were similar to that from off-duty period. However, the median concentration of benzene metabolite in urine sampled after firefighting was three times higher compared to that from off-duty period(34.2 ㎍/g crea. and 10.9 ㎍/g crea., respectively.) The estimated airborne concentration of benzene calculated from metabolite level in urine was 0.16 ppm, which exceeded the recommended exposure level set by the National Institute for Occupational Safety and Health. Conclusions: This study shows that firefighters could be exposed to the high level of VOCs including benzene during their firefighting especially at tyre fire. These results could be used as a valuable data to prove firefighters' exposure to hazardous chemicals during their duty.

화재에 의한 폐타이어 혼합 콘크리트강도 변화에 관한 실험적 연구 (A Strength Change of the Concrete Mixed with Waste Type due to Fire)

  • 손기상
    • 한국화재소방학회논문지
    • /
    • 제16권2호
    • /
    • pp.22-26
    • /
    • 2002
  • 산업체에서 들판에 버려지는 폐타이어 경제적으로 재활용하는 방법을 개발하는 것은 아주 중요한 일이다. 이것은 환경 친화적 정책과도 일관성을 갖는 것이다. 폐타이어 재료를 사용하는 강도에 초점을 맞춘 연구들이 많이 진행되었다. 이제, 정부의 지원하에 국내에서 여러 가지 상이한 입자크기의 폐타이어 재료들이 생산되고 있다. 본 연구는 폐타이어 혼합 콘크리트가 "화재시 온도에 따라" 얼마나 저항하는 지를 밝히는 것이다. 그리고 강도감소율이 얼마인지를 찾아내는 것이다. 이들 관련 결과는 이 분야에 대한 실무적 구조물 적용 방법을 구명하기 위하여 비교되고 있다. 배합비율은 경험과 시행착오 법을 사용하여 결과중에서 예상되는 확정적인 몇 가지들이 결론에 제시되어 있다. 600도 가열시의 폐타이어 배합 콘크리트는 섞지 않은 일반 콘크리트의 경우에 비해 강도 변화가 거의 없었다.화가 거의 없었다.

폐톱밥 혼입 콘크리트의 온도 이력에 관한 실험적 연구 (Temperature Strength of Sawdust-Mixing Concrete)

  • 손기상;홍승렬
    • 한국안전학회지
    • /
    • 제20권4호
    • /
    • pp.46-53
    • /
    • 2005
  • Existing study far fire-resistant concrete has been done already. but it is not found out how the waste tyre mixing concrete will be acted against fire. This waste tyre concrete molds under the condition of $0^{\circ}C,\;200^{\circ}C,\;400^{\circ}C,\;600^{\circ}C$ were heated in gas oven. It was worried about that they might be fractured down at about $800^{\circ}C$ so that they can not be tested. compressive strength for the test molds are made with commercially used $180kg/cm^2,\;210kg/cm^2,\;240kg/cm^2,\;270kg/cm^2$ mixing saw dust with proportion such as 0.05%, 0.1%, 0.2%, 0.4%, 0.6%, 0.8%, 1.0%, 1.2%, 1.4%, 1.6%, 1.8%, 2.0% compressive strength at $200^{\circ}C$ was approximately 20% from the original, while approximately 30% deoreased at $400^{\circ}C$. their results are not quite different from the normal concrete condition even though they contains saw dust in it. The higher strength the concrete has, the less strength was decreased. There are almost no difference in strength under the condition of less than $400^{\circ}C$, but damage of concrete structure could be considerable large with more than $400^{\circ}C$.

VCTF와 IV전선의 반단선에 의한 화재위험성 평가를 위한 열적특성 해석 (Analysis of Thermal Characteristics for the Fire Risk Assessment According to Partial Disconnection on the VCTF and IV Electric Wire)

  • 김두현;김성철;이종호;박종영;박영호;이형준
    • 한국안전학회지
    • /
    • 제23권4호
    • /
    • pp.47-52
    • /
    • 2008
  • Many researches on fire risk for normal electric wiring have been pursued in advanced countries such as the USA and Japan, but comparative studies of the partial disconnection and normal state of electric wires have not been conducted. Detection system for the cause of partial disconnection is not developed and prevention countermeasure for electrical fire by the cause is not effective. Therefore, in this paper, partial disconnection characteristics on electric wires were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF(PVC insulated PVC sheathed Cap Tyre Flexible Cord, KS C 3304) and IV(lndoorwire PVC, KS C 3302). VCTF is used in wiring portable electric appliances and the IV is used indoors. Interrelationships between partial disconnection premonitory symptom and current were derived and analyzed by the characteristics based on experiments and thermal analysis for electric wire according to current under normal state and 200% overload state of rated current.