• Title/Summary/Keyword: typical floor

Search Result 177, Processing Time 0.022 seconds

The Preliminary Research on the Relationship between Carbon Emissions and Typical Floor Design of High-Rise Office Buildings in Shanghai

  • Zhixin, Dong;Yi, Chen
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.2
    • /
    • pp.153-159
    • /
    • 2018
  • The greenhouse effect caused by human activities is becoming increasingly serious. The building industry, which is directly related with carbon emissions, has the responsibility and potentiality to reduce carbon emissions. Recently, Chinese and foreign academics have achieved some research results with respect to building carbon emissions. This paper tries to examine these issues in the context of climate conditions in the Shanghai area. Based on the typical floor plans of high-rise office buildings, analysis was performed via software simulation and data analysis; the paper explores the relationship between different design methods of typical floor plans and carbon emissions. The objective is to deliver results beneficial to typical floor-design methods with respect to the reduction of carbon emissions, so as to provide a reference for architects.

Fundamental Study on the Compressive Strength of Low Cement Concrete for Typical Floor (지상층용 저시멘트 콘크리트의 압축강도 특성에 관한 기초적 연구)

  • Song, Young-Chan;Kim, Yong-Ro;Min, Choong-Siek;Song, Yong-Won;Park, Jong-Ho;Jeong, Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.46-47
    • /
    • 2013
  • In this research, it is investigated strength development by replacement ratio of mineral admixture contents, types of superplastisizer and strength improvement material contents based on industrial byproduct to expand use of low cement concrete for typical floor.

  • PDF

Study of Comparison on Energy Consumption Based on HVAC area along Floor in High Rise Building (고층빌딩의 층별 에너지 사용량 비교에 관한 연구)

  • Park, Woo-Pyeng;Choi, Byong-Jeong;Kim, Jin-Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.1-6
    • /
    • 2018
  • In this study, the energy consumption of the typical floor was compared by the total energy comsumption of the building in highrise building. In gerneral, many researchers are studying on the typical floor in highrise buildings for avoiding complexity in energy simulation. But few papers are studied on energy consumption along the floors. In the model bulding, the energy consumption data were acquired by BEMS system in 2011. According the data, the total net energy consumption was $193.99kWh/m^2$ for all area and the total net energy consumption was $247.61kWh/m^2$ for HVACR area. The total electricity and gas energy are used 47.7% for heating and cooling, 33.5% for lighting and plug, 12.9% for conveyance power and 5.9% for restaurant. In comparison of only ground floor, amount of energy consumption in the lobby is 10%, and 90% of total energy consumption is used in the typical floor. For this result, energy simulation on the typical floor is acceptable for calculating the total energy consumption in the highrise building.

Comparing floor height reduction effect of slim floor system with square steel pipe (각형강관을 이용한 슬림플로어 시스템의 층고절감효과 비교)

  • Cho, Youn-Jin;Rhim, Hong-Chul;Kim, Dae-You;Lyu, Seung-Il;Kim, Do-Kyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.56-57
    • /
    • 2017
  • In recent years, new construction methods have been required to reduce the construction cost and increase the available area in an environment where construction work is frequently performed in a narrow urban area like Korea. As a result of these studies, slim floor composite beam has been suggested. Slim floor composite beam can reduce required depth because web of steel beam is embedded in the slab, so it is effective to reduce floor height and increase the available area. The purpose of this study is the floor height reduction evaluation by comparing system consisting of reinforced concrete, steel, and slim floor using square-shape steel pipe. After doing structural design for a typical plan, checked effectiveness by comparing each design plan. It is proven that slim floor composite beam can reduce required depth effectively comparing required materials of other system.

  • PDF

Evaluation of Floor Vibration Existing in Apartment Building (기존 RC 아파트 바닥의 수직진동 성능 평가)

  • 이민정;한상환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.329-334
    • /
    • 2002
  • In recent years building floors become larger and more spacious due to the development of new design methods and high strength and light weight materials, However, such long span floor systems may provide smaller amount of damping and have longer period so that they would be more vulnerable to the floor vibration. This study attempts to evaluate the performance of the floors in typical apartment buildings. Three different floors with the area of $43.2m^2 41.44m^2 and 34.5m^2$, were investigated. The guideline provided by AISC(1997) is used to check the acceptability of the floor vibration.

  • PDF

An Experimental Study on the Improvement Floor Impact Sound Insulation by Ceiling Structure in Apartment Houses (천장구조를 이용한 공동주택 바닥충격음 차단성능 개선에 관한 실험적 연구)

  • Baek, Eun-Sun
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.95-100
    • /
    • 2007
  • In apartment houses, said to be similar to a typical housing form, every household share the walls and floors. Many problems inevitably accompany such as an arrangement, as noise and vibration are shared among households. When investigating the percentage of apartment resident's dissatisfaction with housing environments, discontent due to noise ranks the highest. Among many different kinds of noises, noise such as floor crashing sounds show the highest indication rate in the residents' comparison of discontent. Therefore, it is the practice of insulating against noises such as floor crashing sounds that improves the apartment house environments. The factors influencing the floor impact sound insulation include floor finishing materials, shock absorbing floors (slabs included), and ceiling structures. The ceilings of the apartment houses, currently built in Korea, are set up with lower parts of slabs and paper finishing, or with double floors for protecting against floor impact sounds in order to improve the sound insulating performance. The most common the method of ceiling structure construction consists of 'wood boarded frames +Gypsum boards + ceiling papers', which is called the wood boarded frame method. This study aimed to measures and evaluates floor impact sound insulation by which the ceiling space are widened according to suppression system is added in apartment house ceiling structure.

Rotational inertial double tuned mass damper for human-induced floor vibration control

  • Wang, Pengcheng;Chen, Jun;Han, Ziping
    • Structural Engineering and Mechanics
    • /
    • v.82 no.3
    • /
    • pp.283-294
    • /
    • 2022
  • An inerter is a passive mechanical element whose inertance can be thousands of times its own physical mass. This paper discusses the application of an inerter-based passive control system, termed rotational inertial double-tuned mass damper (RIDTMD), to mitigate human-induced floor vibrations. First, the acceleration frequency response function of the floor with an RIDTMD is first derived. It is then employed to determine the optimal design parameters of the RIDTMD using the extended fixed-points technique. Based on a theoretical analysis, design-oriented empirical functions are proposed for the RIDTMD optimal parameters, whose performance for floor vibration control is evaluated by numerical examples, in which three typical human-induced load types are considered: walking, jumping, and bouncing. The results indicate that the applicability and effectiveness of the RIDTMD for human-induced floor vibration control are robust for various load types, load frequencies, and floor natural frequencies. For the same mass ratio, the RIDTMD is better than the TMD in reducing the floor vibration amplitude and improving the effective frequency suppression bandwidth, and for the same vibration suppression effect, the mass of the RIDTMD is much lighter than that of the TMD.

A Study on the Survey Method of the Residents′ Housing Needs Using Interactive Media - Focused on the Difference Analysis of Answer Disposition by Media - (인터랙티브 미디어를 이용한 거주자 요구 조사방법에 관한 연구 1 - 매체별 응답성향 차이분석을 중심으로 -)

  • 김석태;오찬옥;박수빈;양세화
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.5
    • /
    • pp.114-124
    • /
    • 2004
  • Most previous studies, in general, related to housing needs have analyzed the data from self-administered survey or interview using questionnaire or simple 2D floor plan. This study was Intended to suggest how to increase the reliability and effectiveness of such survey methods in examining the residents' housing needs. In order to accomplish the purpose, the two kinds of surveys using Web based VR media and typical questionnaire were peformed. The same questions were used for these two surveys, and they included the furniture characteristics, use of each room, adjustment of room size, preferences for interior colors, preferred furniture in living room, space layout of floor plan, housing life style, and preference for housing characteristics. The answer differences between these two were analyzed. The subjects were 402 housewives who lived in apartment houses in Haeundae, Busan. Finding were as follows: first, the media method was more likely to be effective than typical questionnaire survey in explaining housing needs for the adjustment of room size in housing unit plan. Second, the media method was more realistic and reliable than the other in comprehending the needs for the interior colors. Last, the VR media tended to be more effective than the other in understanding the space layout of floor plan. This research sheds light on the utilization of visual instrument for the analysis of needs related to space use.

Evaluation of Floor Vibration Existing in Apartment Building (RC 아파트 바닥의 수직진동 성능 평가)

  • 이민정;한상환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.967-972
    • /
    • 2003
  • In recent years building floors has become larger and more spacious due to the development of new design methods and high strength and light weight materials. However, such long span floor systems may provide smaller amount of damping and have longer period so that they would be more vulnerable to the floor vibration. This study attempts to evaluate the performance of the floors in typical apartment buildings. Four different floors with the area of 43.2$m^2$, 41.44$m^2$, 34.5$m^2$, and 28.89$m^2$ were investigated. The guideline provided by AISC(997) and human perception level of Korean people proposed by S. W. Han(2003) are used to check the acceptability of the floor vibration.

  • PDF

A Study on the Mean Skin Temperature of the Man Who Stay in the Room (재실자의 평균피부온(平均皮膚溫)에 관한 연구)

  • Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.3 no.4
    • /
    • pp.307-317
    • /
    • 2000
  • The purpose of this study is to form a calculation formula of the mean skin temperature on the human body in a heated room by the use of floor heating system. Korean traditional floor heating system is a long way from being defunct. The floor heating systems based on hot water have been coming into wide use mainly in the apartment house. However, it is considered that the design process and evaluation method for the floor heating systems in the standpoint of human being are not established so far. In the floor heating systems, air temperature as well as floor temperature should be considered as physical factors which affect the sensation of human body. Furthermore, extremely few studies have been performed on the sitting with legs crossed posture sedentary which is the typical dwelling life style of residents from the ancient times in Korea, while a large number of studies on the influence of the floor heating systems on the human body in standing and sitting on a chair sedentary have been carried out. Especially, it is essential to elucidate how mean skin temperature on the human body is affected by thermal conduction in the contact area between the sitting with legs crossed posture sedentary human body and floor including thermal radiation due to the combination of air temperature and floor temperature, but the studies dealt with such issues have hardly been performed. Based on the above statements, the influence of the environment condition due to the combination of air temperature and floor temperature is discussed in the present investigation through theoretical of mean skin temperature on the human body in the floor heating systems.

  • PDF