• Title/Summary/Keyword: type of specimens

Search Result 2,202, Processing Time 0.03 seconds

Lateral performance of CRCS connections with tube plate

  • Jafari, Rahman;Attari, Nader K.A.;Nikkhoo, Ali;Alizadeh, Saeid
    • Steel and Composite Structures
    • /
    • v.32 no.1
    • /
    • pp.37-57
    • /
    • 2019
  • This paper presents experimental and analytical studies to evaluate the cyclic behaviour of Circular Reinforced Concrete column Steel beam (CRCS) connections. Two 3/4-scale CRCS specimens are tested under quasi-static reversed cyclic loading. Specimens were strengthened with a tube plate (TP) and a steel doubler plate (SDP). Furthermore; nine interior beam-through type RCS connections are simulated using nonlinear three-dimensional finite element method using ABAQUS software and are verified with experimental results. The results revealed that using the TP improves the performance of the panel zone by providing better confinement to the concrete. Utilizing the TP at the panel zone may absorb and distribute stress in this region. Results demonstrate that TP can be used instead of SDP. Test records indicate that specimens with TP, with and without SDP maintained their maximum strength up to 4% drift angle, satisfying the recommendation given by AISC341-2016 for composite special moment-resisting frames.

Mechanical behavior of hybrid steel-PVA fibers reinforced reactive powder concrete

  • Poorhoseina, Reza;Nematzadeh, Mahdi
    • Computers and Concrete
    • /
    • v.21 no.2
    • /
    • pp.167-179
    • /
    • 2018
  • Reactive powder concrete (RPC) is a type of ultra-high strength cement-based material with a dense microstructure, which is made of ultra-fine powders. RPC demonstrate a very brittle behavior, thus adding fibers improves its mechanical properties. In this study, it was attempted to investigate the effect of using steel and polyvinyl alcohol (PVA) fibers as well as their combination on the properties of RPC. In this regard, hooked-end crimped steel fibers together with short PVA fibers were utilized. Steel and PVA fibers were used with the maximum volume fraction of 3% and 0.75%, respectively, and also different combinations of these fibers were used with the maximum volume fraction of 1% in the concrete mixes. In total, 107 concrete specimens were prepared, and the effect of fiber type and volume fraction on the physico-mechanical properties of RPC including compressive strength, tensile strength, modulus of elasticity, density, and failure mode was explored. In addition, the effect of the curing type on the properties of compressive strength, modulus of elasticity, and density of RPC was evaluated. Finally, coefficients for conversion of cubic compressive strength to cylindrical one for the RPC specimens were obtained under the two curing regimes of heat treatment and standard water curing.

Effects of Stressed and Unstressed Reinforcements on Prestressed Concrete Members with Unbonded Tendons

  • Moon, Jeong-Ho;Shin, Kyung-Jae;Lim, Jae-Hyung;Lee, Sun-Hwa
    • KCI Concrete Journal
    • /
    • v.12 no.1
    • /
    • pp.131-138
    • /
    • 2000
  • The research purpose of this paper is to investigate the influential Parameters on the unbonded tendon stress. The parameters were the reinforcing ratio, the prestressing ratio, and the loading type. To this end. first, the influence of parameters were examined with twenty eight test results obtained from references. Then, an experimental study was carried out with nine specimens. Test variables were the reinforcing ratio and the prestressing ratio. Specimens were divided equally into three groups and each group had a different level of the reinforcing ratio. Each specimen within a group has a different level of the prestressing ratio. The investigation with previous and current tests revealed the followings; (1) the length of crack distribution zone does not have a close relation with the length of plastic hinge. (2) the prestressing ratio does not affect both the length of crack distribution and the length of plastic hinge, (3) the tendon stress variation is in reverse relation with the ratios of mild steels and tendons, (4) the loading type nay not affect significantly the length of crack distribution zone, (5) AASHTO LRFD Code equation and Moon/Lim's design equation predicted the test results well with some safety margins.

  • PDF

Preparation of Silicon Carbide Ceramics with Self-reinforced Microstructure by the Control of Starting Phases (출발상 제어에 의한 자기복합화 미세구조의 탄화규소 세라믹스 제조)

  • Lee, Jong-Kook;Kang, Hyun-Hee;Lee, Eun-Gu;Kim, Hwan
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.12
    • /
    • pp.1240-1246
    • /
    • 1997
  • Silicon carbides with self-reinforced microstructure which hore a small grain matrix and dispersed large grains with rod-like type were prepared by the liquid-phase sintering and the control of starting phases of raw materials. The specimens with self-reinforced microstructure could be obtained from the compacts with mixed compositions of $\alpha$-SiC and 10-50 % $\beta$-SiC powders and by the pressureless sintering at 185$0^{\circ}C$ for 5h. Large grains with rod or plate-like types were 4H-SiC and small grains with equi-axed type were 6H-SiC. Fracture grains with rod or plate-like types were 4h-SiC and small grains with equi-axed type were 6H-SiC. Fracture toughness of specimens with self-reinforced microstructure was increased by the crack deflection and formation of microcracking due to the existence of rod-like large grains during crack propagation.

  • PDF

Shear behavior of exposed column base connections

  • Cui, Yao
    • Steel and Composite Structures
    • /
    • v.21 no.2
    • /
    • pp.357-371
    • /
    • 2016
  • Column base connections are critical components in steel structures because they transfer axial forces, shear forces and moments to the foundation. Exposed column bases are quite commonly used in low- to medium-rise buildings. To investigate shear transfer in exposed column base plates, four large scale specimens were subjected to a combination of axial load (compression or tension) and lateral shear deformations. The main parameters examined experimentally include the number of anchor rod, arrangement of anchor rod, type of lateral loading, and axial force ratio. It is observed that the shear resisting mechanism of exposed column base changed as the axial force changed. When the axial force is in compression, the resisting mechanism is rotation type, and the shear force will be resisted by friction force between base plate and mortar layer. The specimens could sustain inelastic deformation with minimal strength deterioration up to column rotation angle of 3%. The moment resistance and energy dissipation will be increased as the number of anchor rods increased. Moreover, moment resistance could be further increased if the anchor rods were arranged in details. When the axial force is in tension, the resisting mechanism is slip type, and the shear force will be resisted by the anchor rods. And the shear resistance was reduced significantly when the axial force was changed from compression to tension. The test results indicated that the current design approach could estimate the moment resistance within reasonable acceptance, but overestimate the shear resistance of exposed column base.

Evaluation of the Fire Resistance Performance of Interior Anchor Type CFT Columns through Loaded Heating Test

  • Kim, Sunhee;Yom, Kyongsoo;Choi, Sungmo
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.39-48
    • /
    • 2013
  • The fire resistance performance of generic CFT columns has been verified through various tests and analyses and the columns are widely used for fire resistance designs abroad. In this study, 3 groups of specimens (Non-fire protection, reinforcement with steel fiber and fire resistance paint) are suggested in order to evaluate the fire resistance performance of interior anchor type concrete-filled steel tubular columns having efficient cross-sections through loaded heating tests. Axial deformation-time relationship and in-plane temperatures are compared to evaluate the fire resistance performance of the specimens associated with variables. Suggested from the fact that the interior anchors exposed to fire exert influence on fire resistance performance due to thermal expansion, the reinforcements using steel fiber and fire resistance paint are verified to mitigate contraction and improve fire resistance performance. The result obtained from the tests of interior anchor type concrete-filled tubular columns is expected to be used for effective fire resistance design in association with previously conducted studies.

The Evaluation of Fretting Fatigue Behavior on Rotary Bending Fatigue for Railway Axle Material (회전굽힘 피로 하에서의 철도 차축재료 프레팅 피로거동 평가)

  • Choi, Sung-Jong;Kwon, Jong-Wan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.2
    • /
    • pp.74-82
    • /
    • 2010
  • Fretting damage can be observed in automobile and railway vehicle, fossil and nuclear power plant, aircraft etc. In the present study, railway axle material RSA1 used for evaluation of fretting fatigue life. Plain and fretting fatigue tests were carried out using rotary bending fatigue tester with proving ring and bridge type contact pad. Through these test, the following results are obtained: 1) it is found that the fretting fatigue limit of standard specimen decreased about 37% compared to the plain fatigue limit. 2) The early crack of Shinkansen type specimens initiated in contact area and final fractured below samp=214 MPa. 3) The early crack of all TGV type specimens initiated in rounded area and fractured. 4) Tire tracks and rubbed scars were observed in the oblique crack region and fatigue crack growth region of fracture surface. 5) The wear debris is observed on the contact surface, and oblique cracks at an earlier stage are initiated in contact area. These results can be used as useful data in a structural integrity evaluation of railway axle.

Seismic Resisting Capacity Enhancement by S Type Strut Steel Damper Strengthening (S형 스트럿 강재 댐퍼 보강에 의한 RC 골조의 내진성능 향상)

  • Lee, Hyun-Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.4
    • /
    • pp.43-50
    • /
    • 2018
  • The purpose of this study is to improve the seismic performance of RC framed buildings such as piloti buildings and school facilities. For this purpose, a half size RC frame specimen (SFD) was made and the inside of frame was reinforced with steel frame and S type strut steel damper. The experimental results are compared with those of the previous studies under the same conditions. The comparative specimens are non-reinforced specimen (BF) and damper reinforced specimen (AFD) that confined the column with an aramid sheet. As a result of comparing the maximum strength, stiffness degradation and energy dissipation capacity, SFD specimen was evaluated to be better than comparative specimens. According to the experimental results and FE analysis results, it was confirmed that the shear deformation was concentrated in the steel damper. And it was showed that cracks were concentrated at the upper and lower ends of the strut of the S type damper, and the final failure was observed at struts. From this, it was verified that the steel damper appropriately dissipates energy due to the lateral load.

Development of miniature bar-type structural fuses with cold formed bolted connections

  • Guan, Dongzhi;Yang, Sen;Jia, Liang-Jiu;Guo, Zhengxing
    • Steel and Composite Structures
    • /
    • v.34 no.1
    • /
    • pp.53-73
    • /
    • 2020
  • A novel all-steel miniature bar-type structural fuse (MBSF) with cold formed bolted connections is developed in this study, which consists of a central energy dissipation core cut from a smooth round bar, an external confining tube and nuts. Three types of cross sections for the central energy dissipation core, i.e., triple-cut, double-cut and single-cut cross sections, were studied. Totally 18 specimens were axially tested under either symmetric or asymmetric cyclic loading histories, where the parameters such as cut cross sectional area ratio, length of the yielding portion and cross sectional type were investigated. Numerical simulation of 2 representative specimens were also conducted. An analytical model to evaluate the bending failure at the elastic portion was proposed, and a design method to avoid this failure mode was also presented. The experimental results show that the proposed MBSFs exhibit satisfactory hysteretic performance under both the two cyclic loading histories. Average strain values of 8% and 4% are found to be respectively suitable for designing the new MBSFs as the ultimate strain under the symmetric and asymmetric cyclic loadings.

Seismic Behavior of SRC Columns with Alternative Hoops by Steel Clip-Type Devices to Improve Constructability of Closed Hoops (폐쇄형 후프의 시공성을 개선하기 위해 강재 클립형 연결장치로 보강한 대체후프를 갖는 SRC기둥의 내진거동 )

  • Kim, Young-joo;Choi, Byong-Jeong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.4
    • /
    • pp.59-70
    • /
    • 2022
  • In SRC column, the closed hoops are applied with the same detail of both 135° standard hooks to expect the same performance as hoops of RC columns. This standard detail is actually complicated to construct, thus, two separating rebars are connected in the form of a square shape and welded over the overlapping section. But this is also complicated in construction practice. Therefore, this study describes experimental results regarding cyclic behaviors shown with alternative hoops cramped by the steel clip type-binding device instead of welding and standard specimen. As a result of the experiment, the specimens with alternative hoops of the SRC column showed comparable performance to the specimens with closed hoops. Therefore, it can be evaluated that the alternative hoops applied with the rebar confinement clips in the SRC column can replace the closed hoop.