• Title/Summary/Keyword: type of connector

Search Result 164, Processing Time 0.03 seconds

A Study on Measuring Technique of Characteristics for Electromagnetic Wave of Microwave Absorbers (전파흡수체의 전자파적 특성측정기법 연구)

  • Kim, Dong-Il;Chung, Se-Mo;Ahn, Young-Sup
    • Journal of the Korean Institute of Navigation
    • /
    • v.16 no.4
    • /
    • pp.25-34
    • /
    • 1992
  • As a method of measure the absorbing characteristics of microwave absorber, the various microwave measuring method can be used fundamentally. There is, however, a big problem in measuring errors, since the wavelength of microwave such as used for radar is very short. Therefore, this research aimed to design and fabricate a converting adaptor of $20mm^{\phi}$ coaxial tube from a Type-N connector to $20mm^{\phi}$ coaxial tube and to use it for evaluating absorption characteristics of microwave absorber. Furthermore, the measurements of absorbing characteristics and material constants have been performed and review, which were carried out by using the coaxial tube and by using rectangular waveguide, respective. As a result, the validity of the proposed measuring method has been confirmed.

  • PDF

Evaluation of horizontal shear strength of the shear connectors between precast decks and PSC girders (프리캐스트 바닥판과 PSC 거더 전단연결재의 수평전단강도 평가)

  • Hyun, Byung-Hak;Chung, Chul-Hun;Shim, Chang-Su;Kim, Yung-Jin;Lee, Han-Joo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.240-243
    • /
    • 2004
  • A new shear connection for the application of precast decks to PSC girders was proposed and push-off tests were conducted to evaluate the horizontal shear strength of the shear connection. Major parameters of the tests were connector type, shank area, vertical load, surface condition and bedding height. Judging from the test results, shear strength of the suggested shear connection was proportional to the shank area and yield strength of the connectors and was in inverse proportion to the bedding height. Shear connection with shear key at the surface showed better performance. An empirical equation for the evaluation of the shear strength of the shear connection without considering bond strength was proposed and it showed good correlation with the test results.

  • PDF

An Experimental Studies on the Fatigue Behavior of Preflex Girder (프리플렉스형의 피로거동에 관한 실험적 고찰)

  • CHANG, Dong Il;Lee, Myeong Gu;LEE, Seung Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.3 s.28
    • /
    • pp.107-116
    • /
    • 1996
  • The studies are conducted to investigate the fatigue and fracture, behavior of preflex girder. In this work, the fatigue tests using by constant amplitude fatigue loading and 4-point-loading to maintain pure bending condition in the mid-span of preflex girder will be performed. It is expected from the results of the studies to provide the fatigue strength and the S-N curve of preflex girders. In addition, it will be ensured that fracture initiation occurs in the welded part of horseshoe-type shear connector as well as in other welded joints.

  • PDF

Mechanical characteristics of hollow shear connectors under direct shear force

  • Uenaka, Kojiro;Higashiyama, Hiroshi
    • Steel and Composite Structures
    • /
    • v.18 no.2
    • /
    • pp.467-480
    • /
    • 2015
  • The steel-concrete composite decks have high fatigue durability and deformability in comparison with ordinary RC slabs. Withal, the steel-concrete composite deck is mostly heavier than the RC slabs. We have proposed herein a new type of steel-concrete composite deck which is lighter than the typical steel-concrete composite decks. This can be achieved by arranging hollow sectional members as shear connectors, namely, half-pipe or channel shear connectors. The present study aims to experimentally investigate mechanical characteristics of the half-pipe shear connectors under the direct shear force. The shear bond capacity and deformability of the half-pipe shear connectors are strongly affected by the thickness-to-diameter ratio. Additionally, the shear strengths of the hollow shear connectors (i.e. the half-pipe and the channel shear connectors) are compared. Furthermore, shear capacities of the hollow shear connectors equivalent to headed stud connectors are also discussed.

Modification on Movable Storage Furniture by Non-specialist - In the KYUDOGAKUSHA Housing Renovation -

  • YI, Yongkyu;TAKADA, Mitsuo
    • Architectural research
    • /
    • v.10 no.2
    • /
    • pp.1-10
    • /
    • 2008
  • The study is to find possibilities and problems of a small-scale modification on movable storage furniture as an answer to the residents' needs. The study selected one of the renovated housing units at "KYUDOGAKUSHA" as a case study. "KYUDOGAKUSHA" was designed by architect Takeda Goichi in 1926 and was renovated in 2006. The study investigates major two aspects of movable storage furniture, which includes the furniture's layout planning and technical issues of assembling and moving moveable storage furniture. The experimental test result shows that, 1) It is clear that island type of movable storage furniture's layout can facilitate the residents'small-scale modification even though the residents are untrained. 2) To increase the assembling efficiency, the study found that it is necessary to improve the movable storage furniture's casters so that furniture can rotate. Certain moveable furniture which played a role as a connector between other furniture pieces was not able to move vertically and caused a load on other connected furniture; this needed an improvement.

Finite Element Analysis of Connections between RC and Steel Member under Tensile Loading (인장력을 받는 RC 부재와 철골 부재 접합부의 유한요소해석)

  • 김은주;김승훈;서수연;이리형
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.75-82
    • /
    • 2001
  • Finite element analysis using ANSYS program conducted to evaluate the tensile behavior of the connection between reinforced concrete and steel members is presented in this paper. It is assumed that there is a complete bond between head part of the stud and concrete. However, the surface of the column area of stud is separated from the concrete to stop the stress transmission between those. In case of using reinforcement connectors such as C or U type, the interface between concrete and reinforcement is idealized to have strong adhesion. Four concrete-steel specimens which are connected by stud connector or reinforcement connectors are compared and analyzed From the comparison, it was shown that the connection between concrete and steel could be predicted by using the modeling technique used in this paper.

  • PDF

Design of a Biconical Antenna with Cylindrical Loads for EMI Test Site Validation above 1 GHz

  • Kong, Sung-Sik;Choi, Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • In this paper, a biconical type antenna is proposed for EMI test site validation above 1 GHz. To achieve broadband and omni-directional radiation patterns required by international standard(CISPR), the proposed antenna consists of general bicones with cylindrical loads and adopts side feeding method to minimize the influence on H-plane pattern due to feeding cable, balun, and connector. The radiation patterns of the fabricated antenna are measured and the results are compared with CISPR criteria and commercial antenna in our interest frequencies. Although the proposed antenna has a few problems in frequency range of 1 GHz to 2 GHz, it has relatively better performance than commercial antenna.

Development of a Dipstick Gage Type Small Engine oil Deterioration Detection Sensor (딥스틱게이지형 소형 엔진열화감지센서 개발)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.29 no.2
    • /
    • pp.77-84
    • /
    • 2013
  • A small engine-oil-deterioration detection sensor was developed and installed at the tip of a dipstick gage. The sensor part was manufactured using printed circuit board (PCB) manufacturing technology. A set of sensor covers was installed in order to protect the sensor and realize good signal stability. The small engine-oil-deterioration detection sensor system comprised a dual sensor having etched copper electrodes coated with gold and ceramic, a flexible PCB (FPCB) acting as electric wire, and a dummy PCB with only a lock connector. The sensor can easily be installed by insertion through the guide tube of a dipstick gage. Thus, a driver can easily handle it without further installation equipment. The sensor can determine the level of deterioration in the engine oil by estimating the corresponding dielectric constant of the engine oil.

An Analytic Study on the Bond Stress between Concrete and Steel Tube in CFT Rectangular Column (충전각형강관기둥에서 콘크리트와 강관의 부착응력에 관한 해석적 연구)

  • Park, Sung-Moo;Kang, Joo-Won;Kim, Won-Ho;Lee, Hyung-Seok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.2 no.4 s.6
    • /
    • pp.53-60
    • /
    • 2002
  • An analytic study on the bond stress between steel tube and concrete in concrete filled steel(CFT) rectangular column is presented in this paper. Recently buildings need members which are enhanced durability and ductility. Concrete filled rectangular column system is proposed as alternative plan. In this paper, ABAQUS/Standard Version 5.8 which is identified as usefulness for finite element analysis and has various element library is used. The variables in this study are the location and type of shear-connector. The modeling on contact problem practiced by Contact Pair and Contact Pressure method. In the step of physical bond, it is practiced by Change friction option After yielding of models, analytic results is less than that of experimental results.

  • PDF

Frequency Characteristics of the Air Dielectric Standard Capacitors having 4-terminal-Pair connector Type (4-Terminal-Pair 형 공기유전체 전기용량표준기의 주파수 특성)

  • Kim, Han-Jun;Lee, Rae-Duk;Kang, Jeon-Hong;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1214-1217
    • /
    • 2004
  • 현재 전기용량의 국가표준은 1 kHz, 1592 Hz에서만 유지 및 보급이 되고 있다. 그러나 전기용량 및 임피던스를 측정하는 브리지와 LCR meter들은 비교적 넓은 주파수 범위에서 측정이 가능하도록 생산이 되고 있다. 따라서 이러한 기기들의 교정은 실제적으로 사용되고 있는 주파수 전 영역이 아닌 1 kHz 만 되고 있어서 완전한 교정이라고 할 수 없다. 본 논문에서는 이를 해결하기위하여 임피던스 analyzer의 one-port 측정기술을 사용하여 4-terminal-pair(이하 4TP) 전기용량 표준기 각각의 terminal에서 임피던스를 필요 주파수에서 측정하고, 측정된 임피던스 matrix를 이용하여 4TP의 transfer 어드미턴스와 출력임피던스를 계산 하였다.

  • PDF