• Title/Summary/Keyword: type of a ring

Search Result 902, Processing Time 0.031 seconds

Perforated Early Gastric Cancer -A case report- (진행성 위암으로 오인된 조기위암 천공 1예)

  • Lee Moon Soo;Kim Sung Yong;Oh Sang Hyun;hCae Man Kyu;Chung Il Kwon;Baek Moo Jun;Park Kyung Kyu;Kim Chang Ho;Cho Moo Sik
    • Journal of Gastric Cancer
    • /
    • v.1 no.1
    • /
    • pp.64-67
    • /
    • 2001
  • An exceedingly rare case of perforated early gastric cancer is reported. A 68-year-old man developed peritonitis due to perforation of early gastric cancer. An emergency radical operation was performed and was followed by an uneventful recovery. Histologic examination of the surgical specimen showed type III early gastric cancer composed of a signet ring cell carcinoma. Five years after surgery, the patients was alive with no evidence of tumor recurrence. The rarity of this complication in early gastric cancer is discussed, and a review of the literature is presented.

  • PDF

Reduction of Cogging Torque of BLDC Motor by Sinusoidal Air-Gap Flux Density Distribution (BLDC 전동기의 정현적 공극 자속밀도 구현에 의한 코깅 토크 저감)

  • Kim, Samuel;Jeong, Seung-Ho;Rhyu, Se-Hyun;Kwon, Byung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.57-65
    • /
    • 2007
  • Along with the development of power electronics and magnetic materials, permanent magnet (PM) brushless direct current (BLDC) motors are now widely used in many fields of modern industry BLDC motors have many advantages such as high efficiency, large peak torque, easy control of speed, and reliable working characteristics. However, Compared with the other electric motors without a PM, BLDC motors with a PM have inherent cogging torque. It is often a principle source of vibration, noise and difficulty of control in BLDC motors. Cogging torque which is produced by the interaction of the rotor magnetic flux and angular variation in the stator magnetic reluctance can be reduced by sinusoidal air-gap flux density waveform due to reduction of variation of magnetic reluctance. Therefore, this paper will present a design method of magnetizing system for reduction of cogging torque and low manufacturing cost of BLDC motor with isotropic bonded neodynium-iron-boron (Nd-Fe-B) magnets in ring type by sinusoidal air-gap flux density distribution. An analytical technique of magnetization makes use of two-dimensional finite element method (2-D FEM) and Preisach model that expresses the hysteresis phenomenon of magnetic materials in order for accurate calculation. In addition, For optimum design of magnetizing fixture, Factorial design which is one of the design of experiments (DOE) is used.

3.125Gbps Reference-less Clock/Data Recovery using 4X Oversampling (레퍼런스 클록이 없는 3.125Gbps 4X 오버샘플링 클록/데이터 복원 회로)

  • Lee, Sung-Sop;Kang, Jin-Ku
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.10 s.352
    • /
    • pp.28-33
    • /
    • 2006
  • An integrated 3.125Gbps clock and data recovery (CDR) circuit is presented. The circuit does not need a reference clock. It has a phase and frequency detector (PFD), which incorporates a bang-bang type 4X oversampling PD and a rotational frequency detector (FD). It also has a ring oscillator type VCO with four delay stages and three zero-offset charge pumps. With a proposed PD and m, the tracking range of 24% can be achieved. Experimental results show that the circuit is capable of recovering clock and data at rates of 3.125Gbps with 0.18 um CMOS technology. The measured recovered clock jitter (p-p) is about 14ps. The CDR has 1.8volt single power supply. The power dissipation is about 140mW.

Dynamic Characteristics of High-speed Railway Steel Bridges (고속철도 강교량의 진동특성 분석)

  • Lee, Jung-Whee;Kim, Sung-Il;Kwark, Jong-Won;Lee, Pil-Goo;Yoon, Tae-Yang
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.7 s.124
    • /
    • pp.632-637
    • /
    • 2007
  • The dynamic behavior of two steel bridges crossed by the Korean High Speed Train(KHST) has been investigated experimentally and the results are compared with the specification requirement of BRDM and other typical PSC Box bridge's responses. The investigated bridges are a 2-girder steel bridge of 1@40m span length(E-Won Bridge), 2@50m span length (Ji-Tan Bridge), and a PSC Box girder bridge of 2@40m span length (Yeon-Jae Bridge). A set of experimental tests were performed during operation of KHST, and a number of accelerometers, LVDTs and ring-type displacement transducers were utilized for measurement of three kinds of dynamic responses (acceleration, deflection, and end-rotation angle). Measured responses show that the vertical deflections and end-rotation angles of the three bridges are all satisfying the spec. requirement with large margin, but it was also found acceleration responses which are very close or exceed the limit value. Most of the excessive acceleration responses were found when the passing velocity of the KHST is close to the critical velocity ($V_{cr}$) which causes resonance. No noticeable differences of dynamic responses due to the different materials(steel or concrete) could be found within these experimental results.

Design and Evaluation of the Tension Sensor for Surgical Steel Wires (수술용 강선에 대한 인장력 측정센서의 설계 및 특성평가)

  • Joo, Jin-W;Lee, Bong-S
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.2
    • /
    • pp.261-271
    • /
    • 1997
  • This paper presents the design process and characteristic test results of tension sensors for measuring the ultimate tension forces of surgical wires. Three types of sensor were designed and tested for calibration. The first two types which transfer the wire tension to the sensing element by direct contact have too much hysterisis errors due to the firctional effect. This error can be considerably reduced in the modified structure, where a cover and a loading button is used to transfer force and moment to the sensing element. The strains predicted by theoretical equations agree well with those by finite element calculations neglecting friction and the strains by finite element analysis considering friction are in good agreement with those measured by four strain gages. The modified ring type tension sensor developed in this paper is expected to be useful for measuring the tension of surgical wires with nonlinearity of 1.31%FS, hysterisis of 5.74%FS and repeatability of 0.19%FS.

Transducer Combination for High-Quality Ultrasound Tomography Based on Speed of Sound Imaging (속도 분포 기반 단층촬영을 위한 최적의 트랜스듀서의 조합)

  • Kim, Young Hun;Park, Kwan Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.1
    • /
    • pp.27-34
    • /
    • 2016
  • The type of ultrasound transducer used influences the quality of a reconstructed ultrasound image. This study analyzed the effect of transducer type on ultrasound computed tomography (UCT) image quality. The UCT was modeled in an ultrasound simulator by using a 5 cm anatomy model and a ring-shape 5 MHz 128 transducer array, which considered attenuation, refraction, and reflection. Speed-of-sound images were reconstructed by the Radon transform as the UCT image modality. Acoustic impedance images were also reconstructed by the delay-and-sum (DAS) method, which considered the speed of sound information. To determine the optimal combination of transducers in observation, point-source, flat, and focused transducers were tested in combination as trasmitters and receivers; UCT images were constructed from each combination. The combination of point-source/flat transducer as transmitting and receiving devices presented the best reconstructed image quality. In UCT implementation, the combination of a flat transducer for transmitting and a point transducer for receiving permitted acceptable image quality.

Thermal Sprayed AlSiMg/TiC Composite Coatings : Wear Characteristics (II) (AlSiMg/TiC 복합 용사피막 : 마모 특성 (II))

  • 양병모;변응선;박경채
    • Journal of Welding and Joining
    • /
    • v.18 no.5
    • /
    • pp.105-111
    • /
    • 2000
  • The wear behavior of thermal sprayed AlSiMg-40TiC composite coatings were studied as a function of load and sliding velocity under unlubricated conditions. Experiments were performed using a block-on-ring(WC-6wt%/Co, Hv 1500) type. The tests were carried out a various load(30∼ 125.5N) and sliding velocity(0.5∼2.0m/s). Three wear rate regions were observed in the AlSiMg-40TiC composite coatings. The wear rate in region I at low load (less then 8N( were less than 1×{TEX}$10^{-5}${/TEX}㎣/m. Low wear rates in region I resulted from the load-bearing capacity of TiC particles. The transition from region I to II occurred when the applied load exceeded the fracture and pull-out strength of the particles. The TiC fractured particles trapped between the specimen and the counterface acted as third-body abrasive wear. The subsurface layer worn surface in region II was composed of the mechanically mixed layer (MML). The wear rate increase abruptly above a critical load (region III). The high wear rate in region III was induced by frictional temperature and involves massive surface damage.

  • PDF

Postoperative Radiotherapy for Locally Advanced Gastric Cancer (국소적으로 진행된 위암의 수술후 방사선 치료성적)

  • Lee Myung Za;Chun Ha Chung;Kim Insoon;Chung Tejune
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.113-119
    • /
    • 1997
  • Purpose : Radical gastrectomy is main treatment of gastric cancer. But the result is not satisfactory with surgery alone. Most of pattern of failure remain locoregional recurrence. To improve 5 year survival postoperative chemotherapy with or without radiotherapy has been used. We analyzed patients with stage III and IV stomach cancer who had radical operation and received postoperative radiation therapy combined with or without chemotherapy retrospectively. Material and Method : From March 1985 to June 1993, 68 patients treated with curative resection and received postoperative adiuvant radiotherapy with 36Gy or more were evaluated. Median age was 60 years(range 28-66 yrs) . Patients were followed from 3 to 133 months with median follow up of 48 months. Thirty seven patients had non signet ring adenocarcinoma, 29 signet ring cell, 2 other cell. Patients with stage IIIA, IIIB, IV disease were 19, 25 and 24 respectively Chemotherapy was given to all patients except two. Results : Five-year overall survival and disease-free survival rate were 36.6% and 33.6%, respectively. Prognostic factor affecting survival were assessed. High ratio of jnvolved/dissected Iymph node, signet ring histology showed Poor Prognosis with statistical significance. Presence of residual tumor after surgery, stageIV. split course of radiation therapy, age, number of involved Iymph node, number of Iymph node dissection and grade of tumor affected survival without statistical significance, Type of chemotherapy did not affect survival. Recurrence was documented in 34 patients. High recurrence was seen in omentum and peritoneum with 23.5%, and remnant stomach, anastomosis site, A-loop and I-loop had also high recurrence with 13.2%. In field locoregional recurrence was 20.7% and total distant metastases were 39.7%. Total intraabdominal failure was 47.1% and extraabdominal failure was 13.2%. Treatment toxicity was considered to be acceptable. 22.1% of patients had grade 3 and only 1 patient had grade 4 leukopenia. Six Patients(8.8%) had weigh loss more than 10%. Conclusion : Treatment toxicity was acceptable with combined treatment with chemotherapy and radiotherapy. Locoregional recurrence was relatively low compared to distant failure with addition of irradiation. Peritoneal and omental seeding was high Five-rear surival was increased with combined modality. Radiation may eradicate minimal residual disease and improve survival, To evaluate role of radiation Prospective randomized study employing chemotherapy alone and chemotherapy plus radiation is necessary. Futhermore to reduce intraabdominal failure, role of intraabdominal chemotherapy in addition to combined chemotherapy plus radiation has to be explored.

  • PDF

Design of Planetary Gear Drive Unit for Drive Conversion of Transfer case (Transfer case의 구동변환을 위한 유성기어장치 구동부 설계)

  • Youm, Kwang-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.2
    • /
    • pp.21-26
    • /
    • 2022
  • Since the four-wheel drive transmits the driving force to all four wheels, the traction with the road surface increases, thereby increasing the driving force. However, it has the disadvantage of lowering fuel efficiency. Therefore, four-wheel drive is commonly used as a method of converting to optional four-wheel drive when necessary while driving in two-wheel drive. This selective four-wheel drive converts the driving force by mechanically changing the electric signal sent by the driver in the transfer case. In this study, in order to mechanically change the electrical signal, a reducer is applied to the motor to increase the torque to perform the function. Therefore, in this study, a reduction mechanism applicable to the motor inside the transfer case applied to convert the drive is derived, and the reduction ratio applying the planetary gear type is optimized accordingly. And based on the derived reduction ratio, two sets of planetary gears using a ring gear in common were applied to develop a planetary gear tooth type in which the input shaft and output shaft are decelerated in the same phase. Optimization design was carried out.

Vessel Elements of Panax ginseng C.A. Meyer (인삼 (Panax ginseng C.A. Meyer)의 도관요소)

  • 정병갑
    • Journal of Plant Biology
    • /
    • v.31 no.3
    • /
    • pp.169-185
    • /
    • 1988
  • Vessel elements in lateral root, tap root, transition region, stem and mid vein of 1-year old, 3-year old and 5-year old ginseng (Panax ginseng C.A. Meyer) are studied with light microscope to clarify the distribution and differentiation of several kinds of vessel elements. Vessel elements are classified into five types such as ring vessel, spiral vessel, scalariform vessel, reticulate vessel and pitted vessel according to the secondary thickenings of cell wall. All of the five types are not observed in each organ, but diverse kinds of vessels are present in stem and mid vein compared with the underground organs such as tap root and lateral root. The length of vessel elements is longest (680$\mu$m) in stem and shortest (143$\mu$m) in tap root. The diameter of vessel elements is 19.0$\mu$m in tap root and the angle of perforation plate comes under 22$^{\circ}$-60$^{\circ}$. The degree of differentiation of vessel elements according to the length, diameter and angle of perforation plate of vessel elements is highest in tap root regardless of the age of ginseng. Three types of perforation plate such as scalariform, intermediate type of simple and scalariform, and simple perforation plate are observed. The vascular tracheids are characteristically observed in mid vein of 1-year old ginseng, and in transition region of 3 and 5-year old ginseng.

  • PDF