• Title/Summary/Keyword: two-time-scale system

Search Result 439, Processing Time 0.025 seconds

Design of Optimized pRBFNNs-based Face Recognition Algorithm Using Two-dimensional Image and ASM Algorithm (최적 pRBFNNs 패턴분류기 기반 2차원 영상과 ASM 알고리즘을 이용한 얼굴인식 알고리즘 설계)

  • Oh, Sung-Kwun;Ma, Chang-Min;Yoo, Sung-Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.6
    • /
    • pp.749-754
    • /
    • 2011
  • In this study, we propose the design of optimized pRBFNNs-based face recognition system using two-dimensional Image and ASM algorithm. usually the existing 2 dimensional face recognition methods have the effects of the scale change of the image, position variation or the backgrounds of an image. In this paper, the face region information obtained from the detected face region is used for the compensation of these defects. In this paper, we use a CCD camera to obtain a picture frame directly. By using histogram equalization method, we can partially enhance the distorted image influenced by natural as well as artificial illumination. AdaBoost algorithm is used for the detection of face image between face and non-face image area. We can butt up personal profile by extracting the both face contour and shape using ASM(Active Shape Model) and then reduce dimension of image data using PCA. The proposed pRBFNNs consists of three functional modules such as the condition part, the conclusion part, and the inference part. In the condition part of fuzzy rules, input space is partitioned with Fuzzy C-Means clustering. In the conclusion part of rules, the connection weight of RBFNNs is represented as three kinds of polynomials such as constant, linear, and quadratic. The essential design parameters (including learning rate, momentum coefficient and fuzzification coefficient) of the networks are optimized by means of Differential Evolution. The proposed pRBFNNs are applied to real-time face image database and then demonstrated from viewpoint of the output performance and recognition rate.

The System of Converting Muscular Sense into both Color and Sound based on the Synesthetic Perception (공감각인지 기반 근감각신호에서 색·음으로의 변환 시스템)

  • Bae, Myung-Jin;Kim, Sung-Ill
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.5
    • /
    • pp.462-469
    • /
    • 2014
  • As a basic study on both engineering applications and representation methods of synesthesia, this paper aims at building basic system which converts a muscular sense into both visual and auditory elements. As for the building method, data of the muscular sense can be acquired through roll and pitch signals which are calculated from both three-axis acceleration sensor and the two-axis gyro sensor. The roll and pitch signals are then converted into both visual and auditory information as outputs. The roll signals are converted into both intensity elements of the HSI color model and octaves as one of auditory elements. In addition, the pitch signals are converted into both hue elements of the HSI color model and scales as another one of auditory elements. Each of the extracted elements of the HSI color model is converted into each of the three elements of the RGB color model respectively, so that the real-time output color signals can be obtained. Octaves and scales are also converted and synthesized into MIDI signals, so that the real-time sound signals can be obtained as anther one of output signals. In experiments, the results revealed that normal color and sound output signals were successfully obtained from roll and pitch values that represent muscular senses or physical movements, depending on the conversion relationship based on the similarity between color and sound.

THE COMPARATIVE STUDY ON THE SEDATIVE EFFECT OF DIFFERENT INTRAVENOUS MIDAZOLAM DOSAGES FOR PEDIATRIC DENTAL PATIENTS (소아환자의 Midazolam의 정맥투여 용량에 따른 진정 효과에 관한 비교연구)

  • Kim, Eun-Young;Kim, Jong-Soo;You, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.416-426
    • /
    • 2005
  • Intravenous sedation have many advantages of rapid onset and recovery, ability of control sedation levels and duration through titration. Midazolam is most commonly used intravenous medication for sedation in pediatrics, endoscopy, oncologic procedures and so on. But in dentistry, midazolam intravenous sedation is usually for adult, and there are few reports for children. Todays, children who need sedation become more and older, intravenous sedation technique is going a matter of concern in pediatric dentistry. The purpose of this paper is to evaluate the efficacy of sedation and clinical success for different initial dosage of midazolam in intravenous sedation for pediatric dental patients. 16 healthy children (male 10, female 6), mean age $54.7{\pm}10.7$ months, who needed at least two separate treatment visits requiring local anesthesia were chosen for this study. Every children were taken 0.3mg/kg, maximum 5mg of midazolam by intramuscular route, and then 30~50% $N_2O-O_2$ for 10 minutes was given. On every visits, one of the following 2 different initial dosage was given by intravenous route : (1) Group I : 0.1mg/kg Midazolam (2) Group II : 0.2mg/kg Midazolam. Additional dosage was half of the first dose. Physiologic parameters (oxygen saturation, heart rate, respiratory rate, end-tidal carbon dioxide pressure) was recorded by ten procedure steps. Behavior was videotaped and rated using Ohio State University Behavioral Rating Scale and Automated Counting System by one investigator, blind to administered dosage. After the treatment, operator evaluated the clinical success. Physiologic parameters were stable and within normal range during treatment in both groups. The analyzed sedative effect, in behavioral evaluation, ratio of favorable Quiet was higher in group II, and clinical success rate of group II was better than group I. Induction time was rapid in group II, and recovery time was rapid in group I. And there was no statistically difference between two groups in every results.

  • PDF

Clinical Study of Acute and Chronic Pain by the Application of Magnetic Resonance Analyser $I_{TM}$ (자기공명분석기를 이용한 통증관리)

  • Park, Wook;Jin, Hee-Cheol;Cho, Myun-Hyun;Yoon, Suk-Jun;Lee, Jin-Seung;Lee, Jeong-Seok;Choi, Surk-Hwan;Kim, Sung-Yell
    • The Korean Journal of Pain
    • /
    • v.6 no.2
    • /
    • pp.192-198
    • /
    • 1993
  • In 1984, a magnetic resonance spectrometer(magnetic resonance analyser, MRA $I_{TM}$) was developed by Sigrid Lipsett and Ronald J. Weinstock in the USA, Biomedical applications of the spectrometer have been examined by Dr. Hoang Van Duc(pathologist, USC), and Nakamura, et al(Japan). From their theoretical views, the biophysical functions of this machine are to analyse and synthesize a healthy tissue and organ resonance pattern, and to detect and correct an abnormal tissue and organ resonance pattern. All of the above functions are based on Quantum physics. The healthy tissue and organ resonance patterns are predetermined as standard magnetic resonance patterns by digitizing values based on peak resonance emissions(response levels or high pitched echo-sounds amplified via human body). In clinical practice, a counter or neutralizing resonance pattern calculated by the spectrometer can correct a phase-shifted resonance pattern(response levels or low pitched echo-sounds) of a diseased tissue and organ. By administering the counter resonance pattern into the site of pain and trigger point, it is possible to readjust the phase-shifted resonance pattern and then to alleviate pain through regulation of the neurotransmitter function of the nervous system. For assessing clinical effectiveness of pain relief with MRA $I_{TM}$ this study was designed to estimate pain intensity by the patient's subjective verbal rating scale(VRS such as graded to no pain, mild, moderate and severe) before application of it, to evaluate an amount of pain relief as applied the spectrometer by the patients subjective pain relief scale(visual analogue scale, VAS, 0~100%), and then to observe a continuation of pain relief following its application for managing acute and chronic pain in the 102 patients during an 8 months period beginning March, 1993. An application time of the spectrometer ranged from 15 to 30 minutes daily in each patient at or near the site of pain and trigger point when the patient wanted to be treated. The subjects consisted of 54 males and 48 females, with the age distribution between 23~40 years in 29 cases, 41~60 years in 48 cases and 61~76 years in 25 cases respectively(Table 1). The kinds of diagnosis and the main site of pain, the duration of pain before the application, and the frequency of it's application were recorded on the Table 2, 3 and 4. A distinction between acute and chronic pain was defined according to both of the pain intervals lasting within and over 3 months. The results of application of the spectrometer were noted as follows; In 51 cases of acute pain before the application, the pain intensities were rated mild in 10 cases, moderate in 15 cases and severe in 26 cases. The amounts of pain relief were noted as between 30~50% in 9 cases, 51~70% in 13 cases and 71~95% in 29 cases. The continuation of pain relief appeared between 6~24 hours in two cases, 2~5 days in 10 cases, 6~14 days in 4 cases, 15 days in one case, and completely relived of pain in 34 cases(Table 5~7). In 51 cases of chronic pain before the application, the pain intensities were rated mild in 12 cases, moderate in l8 cases and severe in 21 cases. The amounts of pain relief were noted as between 0~50% in 10 cases, 51~70% in 27 cases and 71~90% in 14 cases. The continuation of pain relief appeared to have no effect in two cases. The level of effective duration was between 6~12 hours in two cases, 2~5 days in 11 cases, 6~14 days in 14 cases, 15~60 days in 9 cases and in 13 cases the patient was completely relieved of pain(Table 5~7). There were no complications in the patients except a mild reddening and tingling sensation of skin while applying the spectrometer. Total amounts of pain relief in all of the subjects were accounted as poor and fair in 19(18.6%) cases, good in 40(39.2%) cases and excellent in 43(42.2%) cases. The clinical effectiveness of MRA $I_{TM}$ showed variable distributions from no improvements to complete relief of pain by the patient's assessment. In conclusion, we suggest that MRA $I_{TM}$ may be successful in immediate and continued pain relief but still requires several treatments for continued relief and may be gradually effective in pain relief while being applied repeatedly.

  • PDF

An Adaptive Information Hiding Technique of JPEG2000-based Image using Chaotic System (카오스 시스템을 이용한 JPEG2000-기반 영상의 적응적 정보 은닉 기술)

  • 김수민;서영호;김동욱
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.4
    • /
    • pp.9-21
    • /
    • 2004
  • In this paper, we proposed the image hiding method which decreases calculation amount by encrypt partial data using discrete wavelet transform and linear scale quantization which were adopted as the main technique for frequency transform in JPEG2000 standard. Also we used the chaotic system which has smaller calculation amount than other encryption algorithms and then dramatically decreased calculation amount. This method operates encryption process between quantization and entropy coding for preserving compression ratio of images and uses the subband selection method and the random changing method using the chaotic system. For ciphering the quantization index we use a novel image encryption algerian of cyclically shifted in the right or left direction and encrypts two quantization assignment method (Top-down/Reflection code), made change of data less. Also, suggested encryption method to JPEG2000 progressive transmission. The experiments have been performed with the proposed methods implemented in software for about 500 images. consequently, we are sure that the proposed are efficient image encryption methods to acquire the high encryption effect with small amount of encryption. It has been shown that there exits a relation of trade-off between the execution time and the effect of the encryption. It means that the proposed methods can be selectively used according to the application areas. Also, because the proposed methods are performed in the application layer, they are expected to be a good solution for the end-to-end security problem, which is appearing as one of the important problems in the networks with both wired and wireless sections.

An Assessment of the Usefulness of Time of Flight in Magnetic Resonance Angiography Covering the Aortic Arch

  • Yoo, Yeong-Jun;Choi, Sung-Hyun;Dong, Kyung-Rae;Ji, Yun-Sang;Choi, Ji-Won;Ryu, Jae-Kwang
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.325-332
    • /
    • 2018
  • Carotid angiography covering the aortic arch includes contrast-enhanced magnetic resonance angiography (CEA), which is applied to a large region and usually employs contrast media. However, the use of contrast media can be dangerous in infants, pregnant women, and patients with chronic renal failure (CRF). Follow-up patients informed of a lesion may also want to avoid constant exposure to contrast media. We aimed to apply time-of-flight (TOF) angiography to a large region and compare its usefulness with that of CEA. Ten patients (mean age, 58 years; range, 45~75 years) who visited our hospital for magnetic resonance angiography (MRA) participated in this study. A 3.0 Tesla Achieva magnetic resonance imaging (MRI) system (Philips, Netherland) and the SENSE NeuroVascular 16-channel coil were employed for both methods. Both methods were applied simultaneously to the same patient. Three TOF stacks were connected to cover the aortic arch through the circle of Willis, and CEA was applied in the same manner. For the quantitative assessment, the acquired images were used to set the regions of interest (ROIs) in the common carotid artery (CCA) bifurcation, internal carotid artery, external carotid artery, middle cerebral artery, and vertebral artery, and to obtain the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) for the soft tissues. Three radiologists and one radiological resident performed the qualitative assessment on a 5-point scale - 1 point, "very bad"; 2 points, "bad"; 3 points, "average"; 4 points, "good"; and 5 points, "very good" - with regard to 4 items: (1) sharpness, (2) distortion, (3) vein contamination, and (4) expression of peripheral vessels. For the quantitative assessment, we estimated the mean SNR and CNR in each of the 5 ROIs. In general, the mean SNR was higher in TOF angiography (166.1, 205.2, 154.39, 172.23, and 161.95) than in CEA(92.05, 95.43, 84.76, 73.69, and 88.3). Both methods had a similar mean CNR: 67.62, 106.71, 55.9, 73.74, and 63.46 for TOF angiography, and 67.82, 71.19, 60.52, 49.45, and 64.07 for CEA. In all ROIs, the mean SNR was statistically significant (p<0.05), whereas the mean CNR was insignificant (p>0.05). The mean values of TOF angiography and CEA for each item in the qualitative assessment were 4.2 and 4.28, respectively for item 1; 2.93 and 4.55, respectively, for item 2; 4.6 and 3.13, respectively, for item 3; and 2.88 and 4.65, respectively, for item 4. Therefore, TOF angiography had a higher mean for item 3, and CEA had a higher mean for items 2 and 4; there was no significant difference between the two methods for item 1. The results for item 1 were statistically insignificant (p>0.05), whereas the results for items 2~4 were statistically significant (p<0.05). Both methods have advantages and disadvantages and they complement each other. However, CEA is usually applied to a large region covering the aortic arch. Time-of-flight angiography may be useful for people such as infants, pregnant women, CRF patients, and followup patients for whom the use of contrast media can be dangerous or unnecessary, depending on the circumstance.

Objective Evidence for the Effectiveness of Single-session Treatment with a Spinal Thermal Massage Device: A Pilot Study (척추온열마사지기기의 1회 치료의 효과에 대한 객관적 증거: 선행 연구)

  • Na, Yeong-Il;Kim, Si-Yun;Baek, Seung-Min;Lee, Jong-Hoo
    • Journal of Industrial Convergence
    • /
    • v.20 no.10
    • /
    • pp.209-218
    • /
    • 2022
  • Individuals often report significant relief from pain and stress even after a single session of massage therapy; however, no previous studies have provided objective evidence supporting the effectiveness of a solitary massage therapy session. In the present study, we aimed to investigate the effectiveness of one-time treatment with a spinal thermal massage device reported to exert the same therapeutic effects as massage therapy in terms of pain reduction and stress relief. A man with chronic low back pain (LBP) underwent two rounds of experiments involving spinal massage treatment and bed rest, respectively. Pain was assessed using a visual analog scale, and heart rate variability (HRV) was measured in real-time to examine autonomic nervous system (ANS) activity. Blood samples were obtained at five points during each round of the experiment to examine changes in cortisol, epinephrine, and norepinephrine. Spinal massage significantly reduced pain and enhanced parasympathetic activity when compared with the bed rest condition. In addition, both epinephrine and norepinephrine levels were lower following spinal massage than following bed rest. These results are consistent with the reported effects of conventional massage therapy and support the effectiveness of one-time treatment using a spinal thermal massage device.

Change of Quality of Life in Children with ADHD after 12 Weeks OROS-Methylphenidate Treatment (12주 OROS-Methylphenidate 약물 치료 후 ADHD 아동의 삶의 질 변화)

  • Kim, Hyung-In;Kim, Bung-Nyun;Cho, Soo-Churl;Shin, Min-Sup;Yoo, Hee-Jeong;Kim, Jae-Won;Kim, Ji-Hoon;Son, Jung-Woo;Shin, Yun-Mi;Chung, Un-Sun;Han, Doug-Hyun
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.23 no.3
    • /
    • pp.103-108
    • /
    • 2012
  • Objectives : The aim of this study is to investigate the effectiveness of treatment with osmotic-release oral system methylphenidate (OROS-MPH) on quality of life (QOL) in children with attention-deficit hyperactivity disorder (ADHD). Another aim is to assess the relationship between change in QOL and other factors including children's symptoms and academic performance or parents' depression and parenting stress. Methods : A total of 111 medication-naive children with ADHD in a multicenter, open-label, 12-week trial of OROS-MPH completed an evaluation using diverse rating scales at two time points; at baseline and after 12 weeks of treatment. Scales for investigation of children included the Parent Report Form-Children's Health and Illness Profile-Children's Edition (PRF-CHIP-CE) on QOL, the ADHD Rating Scale-IV on symptoms, and the Academic Performance Rating Scale (APRS). The Beck Depression Inventory and Parenting Stress Index were used for assessment of their parents. Results : Total scores for mean PRF-CHIP-CE increased from $207.9{\pm}26.7$ at baseline to $226.3{\pm}25.9$ after 12 weeks of treatment (p<.001). The change of APRS showed the strongest correlation with the increment of PRF-CHIP-CE scores (Pearson coefficient=0.561, p<.001), even after controlling for other factors (partial correlation coefficient=0.420, p<.001). Conclusion : Treatment with MPH-OROS results in improvement of QOL in children with ADHD in Korea. The advance in academic performance plays a key role in this change of QOL.

A Multicenter Noncomparative Clinical Study on Midface Rejuvenation Using a Nonabsorbable Polypropylene Mesh: Evaluation of Efficacy and Safety

  • Pak, Chang Sik;Chang, Lan Sook;Lee, Hobin;Jeong, Jae Hoon;Jeong, Jinwook;Yoon, Eul-Sik;Heo, Chan Yeong
    • Archives of Plastic Surgery
    • /
    • v.42 no.5
    • /
    • pp.572-579
    • /
    • 2015
  • Background Facial rejuvenation can be achieved using a variety of techniques. Since minimally invasive procedures for face lifting have become popular because of their convenience and short operating time, numerous minimally invasive surgical procedures have been developed. In this study, a nonabsorbable polypropylene mesh is introduced as a new face lifting instrument, with the nasolabial fold as the main target area. In this paper, we report the efficacy and safety of a polypropylene mesh in midface rejuvenation. Methods Thirty-three subjects with moderate-to-severe nasolabial folds were enrolled from two medical institutions for a noncomparative single-sample study. A mesh was inserted above the superficial muscular aponeurotic system layer, reaching the nasolabial folds through a temporal scalp incision. After 3 weeks, the temporal end of the mesh was pulled to provide a lifting effect. Then, the mesh was fixed to the deep temporal fascia using nonabsorbable sutures. To evaluate efficacy, we compared the scores on the Wrinkle Severity Rating Scale and a visual analog scale for patient satisfaction between the baseline and 7 weeks postoperatively. In addition, we evaluated safety based on the incidence of adverse events. Results The treatment was deemed effective at improving wrinkles in 23 of 28 cases, and patient satisfaction improved significantly during the study period. There were seven cases of skin or subcutaneous tissue complications, including edema and erythema, but there were no suspected serious adverse events. Conclusions Face lifting using a nonabsorbable mesh can improve nasolabial folds without serious adverse effects. Thus, this technique is safe and effective for midface rejuvenation.

Optimization and Performance Analysis of Distributed Parallel Processing Platform for Terminology Recognition System (전문용어 인식 시스템을 위한 분산 병렬 처리 플랫폼 최적화 및 성능평가)

  • Choi, Yun-Soo;Lee, Won-Goo;Lee, Min-Ho;Choi, Dong-Hoon;Yoon, Hwa-Mook;Song, Sa-kwang;Jung, Han-Min
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.1-10
    • /
    • 2012
  • Many statistical methods have been adapted for terminology recognition to improve its accuracy. However, since previous studies have been carried out in a single core or a single machine, they have difficulties in real-time analysing explosively increasing documents. In this study, the task where bottlenecks occur in the process of terminology recognition is classified into linguistic processing in the process of 'candidate terminology extraction' and collection of statistical information in the process of 'terminology weight assignment'. A terminology recognition system is implemented and experimented to address each task by means of the distributed parallel processing-based MapReduce. The experiments were performed in two ways; the first experiment result revealed that distributed parallel processing by means of 12 nodes improves processing speed by 11.27 times as compared to the case of using a single machine and the second experiment was carried out on 1) default environment, 2) multiple reducers, 3) combiner, and 4) the combination of 2)and 3), and the use of 3) showed the best performance. Our terminology recognition system contributes to speed up knowledge extraction of large scale science and technology documents.