• Title/Summary/Keyword: two-tank 기법

Search Result 53, Processing Time 0.025 seconds

Radiation Problem Involving Two-layer Fluid in Frequency-Domain Numerical Wave Tank Using Artificial Damping Scheme (주파수 영역에서 인공감쇠기법을 활용한 복층 유체의 수치조파수조 방사 문제)

  • Min, Eun-Hong;Koo, Weoncheol
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • There are two wave modes induced by an oscillating body on the free surface of a two-layer fluid: the barotropic and baroclinic modes. To investigate the generated waves composed of two modes, a radiation problem involving a heaving rectangular body was solved in a numerical wave tank. A new artificial damping zone scheme was developed and applied in the frequency-domain analysis. The performance of this damping scheme was compared with given radiation boundary conditions for various conditions. The added mass and radiation damping coefficients for the heaving rectangular body were also calculated for various fluid-density ratios.

Suggestion of the Analysis Model and Verification on Rotating Flow in Stirred Tanks Using CFD (전산유체역학을 이용한 교반 탱크 내에서의 회전유동에 대한 해석 모델의 제안 및 검증)

  • Hwang, Seung Sik;Yong, Cho Hwan;Choi, Gyuhong;Shin, Dohghoon;Chung, Tae Yong
    • Journal of Energy Engineering
    • /
    • v.22 no.1
    • /
    • pp.28-37
    • /
    • 2013
  • Stirred tank is widely used in various industries for mixing operations and chemical reactions for single- or multi-phase fluid systems. For designing agitator of high performance, quantity data of internal flow characteristics influenced by mixing performance are definitely confirmed but quantity analysis about the transient flow characteristics of complicate structure is recognized as difficult problem in the present. In this study, two models of commercial CFD code Fluent 6.3 used to propose suitable for the tank analysis. Agitation of Stirred tank is analyzed using a mixed model and the flow in the stirred tank is analyzed using a standard k-${\varepsilon}$ model. Multiple reference frame(MRF) and Sliding mesh(SM), the analysis techniques were used For compare a result of CFD with a visualization experiment result, to grasp internal flow and mixing characteristic in stirred tank and to present fundamental analysis method.

An Experimental Study on Selective Withdrawal from Linear Stratified Tank (선형 성층수조에서의 선택취수에 관한 실험적 연구)

  • Kim, Young Do;Park, Jae Hyeon;Son, Byung Ju
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6B
    • /
    • pp.499-505
    • /
    • 2011
  • The mixing behavior of turbidity currents in a reservoir is closely related with the annual temperature change of the reservoir. In the summer, the reservoir has a well defined structure: one or two thermoclines and some layers of different densities. This density stratification inhibits vertical mixing and affects various hydrodynamic processes within the reservoir. Therefore, many reservoirs can be operated to release water of the specific quality with the selective withdrawal. In this study, the hydraulic experiments were performed to analyze the efficiency of selective withdrawal. The velocity distributions are measured with PIV in the stratified tank with the "two-tank" method. The relationship between the Richardson number and the selective withdrawal efficiency are provided using the measured velocity distributions.

A Study on the Durability Estimation of Vehicle Fuel Tank (차량용 연료탱크의 내구도 평가에 관한 연구)

  • Hong, Min-Sung;Cho, Eun-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.614-620
    • /
    • 2009
  • A fuel tank of a vehicle is an important part due to its flammable contents ant its importance during crash conditions. Therefore, the fuel tank's design should be assessed for durability and robustness to ensure safety during the early development phase. Previously, evaluation for the durability was done by testing in physical driving conditions which could only be done after the completion of the vehicle. Computation simulation is a more effective method to evaluate the strength and durability of the fuel tank during the early stage. In this paper, two outstanding computational simulation methods are studied. One evaluates PV cycle fatigue due to build up pressure in the fuel tank and the other evaluates the PSD vibration fatigue from modal characteristics. The results show that computational methods agree with physical tests and are thus suitable to analyze the strength and durability of the fuel tank at early development phase.

  • PDF

A Numerical Study on Mixing of Liquid Fuel and Solid Particles in a Fuel Tank (연료탱크내 액체연료와 고체입자의 혼합 수치해석 연구)

  • Kim, Myung-Ho;Ryu, Gyong-Won;Min, Seong-Ki;Hwang, Ki-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.745-749
    • /
    • 2011
  • Two-dimemsional liquid-solid multiphase fluid dynamics was used to analyze the suspension and mix of liquid fuel and solid particles in fuel tank installed mixing impeller. In this paper, the multiphase flow was modeled using Eulerian Grandular Multiphase model. Experimental measurements of the axial distribution of solids concentration in stirred tanks under 12vol% solid loading were used for comparison with the CFD simulation. Four cases for the impeller location and flow pumping direction also were reviewed under 10.5% solids loading and 700rpm in fuel mix tank. The result of quality of suspension was compared with each cases and the impeller location and operation of mixing fuel tank was established.

  • PDF

Transient Response Analysis of Cylindrical Liquid Fuel-Storage Tank subject to Initial Acceleration (원통형 액체 연료탱크의 초기 가속에 따른 과도응답 해석)

  • Lee, S.Y.;Joo, Y.S.;Kim, K.W.;Cho, J.R.
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.475-480
    • /
    • 2000
  • The transient dynamic-response analysis of fuel-storage tanks of flying vehicles accelerating in the vertical direction is achieved with finite element method. A fuel-storage tank is a representative example of the fluid-structure interaction problem, in which structure and fluid media interact strongly. For the accurate analysis of this complicated fluid-structure system, we employed ALE(arbitrary Lagrangian-Eulerian) coupling method. Two types of fuel-storage tanks, one with two baffles and the other without baffle, are considered to examine the effect of baffles. The fuel-storage tank with baffles shows more uniform hydrodynamic pressure distribution, resulting effective stress in structural region and faster convergence from transient to steady states. MSC/Dytran, a commercial FEM software for the 3D coupled dynamic analysis, is used for this analysis.

  • PDF

Performance Evaluation of Underwater Code Division Multiple Access Scheme on Forward-Link through Water-Tank and Lake Experiment (수조 및 저수지 실험을 통한 수중 코드 분할 다중 접속 기법 순방향 링크 성능 분석)

  • Seo, Bo-Min;Son, Kweon;Cho, Ho-Shin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.2
    • /
    • pp.199-208
    • /
    • 2014
  • Code division multiple access (CDMA) is one of the promising medium access control (MAC) schemes for underwater acoustic sensor networks because of its robustness against frequency-selective fading and high frequency-reuse efficiency. As a way of performance evaluation, sea or lake experiment has been employed along with computer simulation.. In this study, we design the underwater CDMA forward-link transceiver and evaluate the feasibility aginst harsh underwater acoustic channel in water-tank first. Then, based on the water-tank experiment results, we improved the transceiver and showed the improvements in a lake experiment. A pseudo random noise code acquisition process is added for phase error correction before decoding the user data by means of a Walsh code in the receiver. Interleaving and convolutional channel coding scheme are also used for performance improvement. Experimental results show that the multiplexed data is recovered by means of demultiplexing at receivers with error-free in case of two users while with less than 15% bit error rate in case of three and four users.

Development of Numerical Computation Techniques for the Free-Surface of U-Tube Type Anti-roll Tank (U-튜브형 횡동요 감쇄 탱크의 자유수면 해석기법 개발에 관한 연구)

  • Sang-Eui Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.7
    • /
    • pp.1244-1251
    • /
    • 2022
  • Marine accidents due to a loss of stability, have been gradually increasing over the last decade. Measures must be taken on the roll reduction of a ship. Amongst the measures, building an anti-roll tank in a ship is recognized as the most simple and effective way to reduce the roll motion. Therefore, this study aims to develop a computational model for a U-tube type anti-roll tank and to validate it by experiment. In particular, to validate the developed computational model, the height of the free surface in the tank was measured in the experiment. To develop a computational model, the mesh dependency test was carried out. Further, the effects of a turbulence model, time step size, and the number of iterations on the numerical solution were analyzed. In summary, a U-tube type anti-roll tank simulation had to be performed accurately with conditions of a realizable k-𝜖 turbulence model, 10-2s time step size, and 15 iterations. In validation, the two cases of measured data from the experiment were compared with the numerical results. In the present study, STAR-CCM+ (ver. 17.02), a RANS-based commercial solver was used.

A Study on the Improvement of Hydrogen Tank Fueling Performance Using MC Methods (MC 기법을 이용한 수소 탱크 충전 성능 향상에 관한 연구)

  • JIAH CHOI;SANGWON JI;JISEONG JANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.5
    • /
    • pp.447-455
    • /
    • 2023
  • SAE J2601, hydrogen fueling protocols, proposes two charging methods. The first is the table-based fueling protocol, and the second is the MC formula-based fueling protocol. Among them, MC formula-based fueling protocol calculates and supplies the target pressure and pressure ramp rate (PRR) using the pre-cooling temperature of the hydrogen and the physical parameters of the tank in the vehicle. The coefficient of the MC formula for deriving MC varies depending on the physical parameters of the tank in the vehicle. However, most studies use the MC coefficient derived from SAE J2601 as it is, despite the difference in the physical parameters of the tank applied to the study and the tank used to derive the MC coefficient from SAE J2601. In this study, the MC coefficient was derived by applying the hydrogen tank currently used, and the difference with the fueling performance using the MC coefficient proposed in SAE J2601 was verified. In addition, the difference was confirmed by comparing and analyzing the fueling performance of the table-based method currently used in hydrogen fueling stations and the MC formula-based method using MC coefficient derived in this study.

A Case Study on the Method to Improve on the Structure of Oil Tank (유류탱크 수명과 구조 개선 방안에 대한 사례연구)

  • Yoon, Tae Gook;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.2
    • /
    • pp.185-190
    • /
    • 2006
  • This study carried out an evaluation of an oil tank that was defective in structure. This paper is divided into two sections which are analysis for the working process and suggestion for improving on the structure of the oil tank. As stated above, it has three major factors as to an improvement, such as the life cycle of structure (especially physical life cycle), and the many factors related to the duration years of the oil tank and analysis result. Based on this study, the improvement of oil tank was established. For example, the ground investigation needs before design and construction of oil tank, and constructing the oil tank by retaining wall type tank is good for maintenance. Also, it is important that the system for drainage is related to maintenance.