• 제목/요약/키워드: two-stage concrete

검색결과 181건 처리시간 0.024초

Construction stages analyses using time dependent material properties of concrete arch dams

  • Sevim, Baris;Altunisik, Ahmet C.;Bayraktar, Alemdar
    • Computers and Concrete
    • /
    • 제14권5호
    • /
    • pp.599-612
    • /
    • 2014
  • This paper presents the effects of the construction stages using time dependent material properties on the structural behaviour of concrete arch dams. For this purpose, a double curvature Type-5 arch dam suggested in "Arch Dams" symposium in England in 1968 is selected as a numerical example. Finite element models of Type-5 arch dam are modelled using SAP2000 program. Geometric nonlinearity is taken into consideration in the construction stage analysis using P-Delta plus large displacement criterion. In addition, the time dependent material strength variations and geometric variations are included in the analysis. Elasticity modulus, creep and shrinkage are computed for different stages of the construction process. In the construction stage analyses, a total of 64 construction stages are included. Each stage has generally $6000m^3$ concrete volume. Total duration is taken into account as 1280 days. Maximum total step and maximum iteration for each step are selected as 200 and 50, respectively. The structural behaviour of the arch dam at different construction stages has been examined. Two different finite element analyses cases are performed. In the first case, construction stages using time dependent material properties are considered. In the second case, only linear static analysis (not considered construction stages) is taken into account. Variation of the displacements and stresses are obtained from the both analyses. It is highlighted that construction stage analysis using time dependent material strength variations and geometric variations has an important effect on the structural behaviour of arch dams. The maximum longitudinal, transverse and vertical displacements obtained from construction stages and static analyses are 1.35 mm and 0 mm; -8.44 and 6.68 mm; -4.00 and -9.90 mm, respectively. In addition, vertical displacements increase from the base to crest of the dam for both analyses. The maximum S11, S22 and S33 stresses are obtained as 1.60MPa and 2.84MPa; 1.39MPa and 2.43MPa; 0.60MPa and 0.50MPa, respectively. The differences between maximum longitudinal, transverse, and vertical stresses obtained from construction stage and static analyses are 78%, 75%, and %17, respectively. On the other hand, there is averagely 12% difference between minimum stresses for all three directions.

콘크리트포장의 초기 열팽창계수 및 건조수축 측정 연구 (Measurement of the Early-Age Coefficient of Thermal Expansion and Drying Shrinkage of Concrete Pavement)

  • 윤영미;서영찬;김형배
    • 한국도로학회논문집
    • /
    • 제10권1호
    • /
    • pp.117-122
    • /
    • 2008
  • 콘크리트포장은 시공초기의 품질관리수준에 따라 전체수명이 결정될 정도로 시공초기의 품질관리가 매우 중요하다. 이러한 초기 품질관리는 콘크리트포장의 초기거동을 잘 파악하여 초기거동을 조절할 수 있는 방안을 도출하는 것이 중요하다. 콘크리트포장의 초기거동에 영향을 주는 요소는 크게 두 가지가 있다. 첫째는 콘크리트의 건조수축이고, 두 번째는 수화열 및 대기온도 변화에 따른 포장체의 온도변화이다. 따라서, 콘크리트의 열팽창계수와 건조수축은 콘크리트의 초기거동에 매우 중요한 요소라 할 수 있다. 지금까지의 열팽창계수는 완전히 양생된 콘크리트에 대해 실험하는 것이 일반적이었기 때문에 시공초기에 열팽창계수를 얻는데 한계가 있어 왔다. 또 건조수축도 시간방법의 한계로 초기 건조수축을 측정하는데 어려움이 있어 왔다. 본 연구에서는 콘크리트포장의 초기 거동을 조절할 수 있는 방안을 도출하기 위하여, 콘크리트의 초기 건조수축과 열팽창계수를 측정하고 이를 통해 콘크리트포장의 초기 거동 예측프로그램의 입력변수들과 적용 모델들에 대한 자료제공 및 검증을 위 한 기초자료를 제공하는데 그 목적을 두었다. 본 연구에서 얻은 결론은 현장에서 초기 콘크리트의 열팽창계수 값을 측정한 결과 $8.9{\sim}10.8{\times}10^{-6}/^{\circ}C$ 값을 나타내었으며, 콘크리트의 건조수축에 있어서 깊이별 effect와 size effect가 존재하는 것으로 분석되었다.

  • PDF

강재 경계요소를 갖는 콘크리트 벽체의 내진 성능 (Seismic Response of Concrete Walls with Steel Boundary Elements)

  • 조순호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.290-297
    • /
    • 2000
  • A new form of construction utilizing structural steel as the boundary elements in ductile flexural concrete walls is proposed to solve the bar congestion problems associated with such a heavily reinforced region. Two wall specimens containing rectangular hollow structural sections(HSS) and channels at their ends respectively were constructed rectangular hollow structural sections(HSS) and channels ar their ends respectively were constructed and tested under reversed cyclic loading to evaluate the construction process as well as the structural performance. One companion standard reinforced concrete wall specimen was also tested for the comparison purpose At an Initial stage all three specimens were carefully detailed to have the approximately same flexural capacity. Analysis and comparison of test results indicated that the reversed cyclic responses of the three walls showed similar hysteretic properties but in those with steel boundaries local bucking of the corresponding steel elements following significant yielding of structural steel was prominent. Design procedures considering local instability of the structural steel elements and the interaction between steel chord and concrete web members in such composite walls are presented.

  • PDF

Deep learning of sweep signal for damage detection on the surface of concrete

  • Gao Shanga;Jun Chen
    • Computers and Concrete
    • /
    • 제32권5호
    • /
    • pp.475-486
    • /
    • 2023
  • Nondestructive evaluation (NDE) is an important task of civil engineering structure monitoring and inspection, but minor damage such as small cracks in local structure is difficult to observe. If cracks continued expansion may cause partial or even overall damage to the structure. Therefore, monitoring and detecting the structure in the early stage of crack propagation is important. The crack detection technology based on machine vision has been widely studied, but there are still some problems such as bad recognition effect for small cracks. In this paper, we proposed a deep learning method based on sweep signals to evaluate concrete surface crack with a width less than 1 mm. Two convolutional neural networks (CNNs) are used to analyze the one-dimensional (1D) frequency sweep signal and the two-dimensional (2D) time-frequency image, respectively, and the probability value of average damage (ADPV) is proposed to evaluate the minor damage of structural. Finally, we use the standard deviation of energy ratio change (ERVSD) and infrared thermography (IRT) to compare with ADPV to verify the effectiveness of the method proposed in this paper. The experiment results show that the method proposed in this paper can effectively predict whether the concrete surface is damaged and the severity of damage.

Fracture toughness of high performance concrete subjected to elevated temperatures Part 1 The effects of heating temperatures and testing conditions (hot and cold)

  • Zhang, Binsheng;Cullen, Martin;Kilpatrick, Tony
    • Advances in concrete construction
    • /
    • 제2권2호
    • /
    • pp.145-162
    • /
    • 2014
  • In this study, the fracture toughness $K_{IC}$ of high performance concrete (HPC) was determined by conducting three-point bending tests on eighty notched HPC beams of $500mm{\times}100mm{\times}100mm$ at high temperatures up to $450^{\circ}C$ (hot) and in cooled-down states (cold). When the concrete beams exposed to high temperatures for 16 hours, both thermal and hygric equilibriums were generally achieved. $K_{IC}$ for the hot concrete sustained a monotonic decrease tendency with the increasing temperature, with a sudden drop at $105^{\circ}C$. For the cold concrete, $K_{IC}$ sustained a two-stage decrease trend, dropping slowly with the heating temperature up to $150^{\circ}C$ and rapidly thereafter. The fracture energy-based fracture toughness $K_{IC}$' was found to follow similar decrease trends with the heating temperature. The weight loss, the fracture energy and the modulus of rapture were also evaluated.

초등학생의 부력 개념 형성과 인지 수준의 관계 (Elementary School Students형 Conceptions of Buoyance related with Cognitive Levels)

  • 권도현;권성기
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제19권1호
    • /
    • pp.131-143
    • /
    • 2000
  • The unit of a buoyant force included in the 7th national science curriculum for 6th grade students. On the contrary, it seldom that students' conception about buoyant phenomena is studied, even though there has been many studies of students' conceptions of basic science contents. The purpose of this study was to survey the elementary school students' conceptions of a buoyant force, to analyze their cognitive levels, and to explore the relationships between them. Sixth grade students (total numbers is 192) were selected .from 5 .lasses in two elementary schools in a local city of Kyungsangdo. They were asked to respond two kinds of test, which are the Logical Thinking Ability (GALT) to investigate students' cognitive levels and the Buoyant Force Questionnaire (BFQ). We developed BFQ test, based on the 7th national science curriculum for 6th grade and the previous researches of a buoyant force. We, qualitatively, analysed students' frequency of responses about a buoyant force and their types of explanation, and, quantitatively, analysed the relationships between cognitive levels and conceptions of a buoyant force with SPSS/ PC 7.0 programmes. The results of cognitive level showed that half of 6th grade students were in the concrete operational stage, 43.2% in the transitional stage, 6.8% in the formal stage. However, their sub-logical thinking abilities in a combinational, conservational, controlling variables, proportional, probability and correlational logic were very fluctuated from 91% to 8%. The results that only 4.8% of elementary students had correct conceptions of a buoyant force suggest that 6th grade students had great difficulties in understanding of that concept. Their difficulties would originated from the frequent common-sense explanations of a buoyant phenomena in terms of the weight or the unique properties or the contact area of an object or with/without air. Furthermore students' explanations, frequently, changed with context of problems of a buoyant force. Scheffe test of quantitative results that elementary students in the concrete level had 50.6% of concept formation in a buoyant force, the transitional level 54.5%, and in the formal operational level 62.8% showed significant differences of conceptions of a buoyant force with cognitive levels. Therefore the concrete operational elementary students had more difficulties of understanding of a buoyant force than the transitional and formal level, which is required to higher cognitive levels. This conclusion have implications that the unit of a buoyant force have to be presented with concrete activities for majority of students who are in concrete and transitional levels.

  • PDF

Nonlinear analysis of prestressed concrete structures considering slip behavior of tendons

  • Kwak, Hyo-Gyoung;Kim, Jae-Hong;Kim, Sun-Hoon
    • Computers and Concrete
    • /
    • 제3권1호
    • /
    • pp.43-64
    • /
    • 2006
  • A tendon model that can effectively be used in finite element analyses of prestressed concrete (PSC) structures with bonded tendons is proposed on the basis of the bond characteristics between a tendon and its surrounding concrete. Since tensile forces between adjacent cracks are transmitted from a tendon to concrete by bond forces, the constitutive law of a bonded tendon stiffened by grouting is different from that of a bare tendon. Accordingly, the apparent yield stress of an embedded tendon is determined from the bond-slip relationship. The definition of the multi-linear average stress-strain relationship is then obtained through a linear interpolation of the stress difference at the post-yielding stage. Unlike in the case of a bonded tendon, on the other hand, a stress increase beyond the effective prestress in an unbonded tendon is not section-dependent but member-dependent. The tendon stress unequivocally represents a uniform distribution along the length when the friction loss is excluded. Thus, using a strain reduction factor, the modified stress-strain curve of an unbonded tendon is derived by successive iterations. The validity of the proposed two tendon models is verified through correlation studies between analytical and experimental results for PSC beams and slabs.

고강도(高强度) 콘크리트에서 기포조직(氣泡組織) 및 강도특성(强度特性)이 연결융해저항(連結融解抵抗)에 미치는 영향(影響) (Effect of Air Void and Strength Characteristics with Freezing and Thawing Resistance on High Strength Concrete)

  • 김생빈;문제길;김동신
    • 대한토목학회논문집
    • /
    • 제13권3호
    • /
    • pp.13-24
    • /
    • 1993
  • 본(本) 연구(硏究)는 고강도(高强度) 콘크리트가 외부(外部)로부터의 수분(水分)의 공급(供給)을 받으면서 상온(常溫)에서 저온(低溫)까지의 가혹한 기상작용을 되풀이 받을 때 고강도(高强度) 콘크리트의 연결융해(連結融解)저항에 미치는 기포조직(氣泡組織) 및 강도특성(强度特性)의 영향에 대한 실험적(實驗的) 연구(硏究)이다. 이 연구(硏究)를 위하여 1단계 실험(實驗)에서는 보통 포틀랜드 시멘트를 사용한 AE콘크리트와 non-AE 콘크리트에 대해 물 시멘트비와 공기량을 중심(中心)으로 내연해성(耐連害性)과 기포조직과의 관계를 규명하고, 2단계 실험(實驗)에서는 non-AE 콘크리트의 내연해성(耐連害性)을 향상(向上)시키기 위해 공시체(供試體) 제작시 진동다짐으로 세심한 주의를 기울이고, 또 동결융해 시험시의 초기강도를 높이기 위해 조강(早强)포틀랜드 시멘트를 사용하여 고수밀성(高水密性)의 콘크리트를 제작하여 실험하였다. 이때 수밀성(水密性)를 투수시험(透水試驗)에 의한 투수계수(透水係數)를 측정하여 판단하고 아울러 고수밀성(高水密性) 콘크리트의 기포조직(氣泡組織)도 측정하였다.

  • PDF

Complete collapse test of reinforced concrete columns

  • Abdullah, Abdullah;Takiguchi, Katsuki
    • Structural Engineering and Mechanics
    • /
    • 제12권2호
    • /
    • pp.157-168
    • /
    • 2001
  • In this paper, experimental investigation into the behavior of reinforced concrete (RC) columns tested under large lateral displacement with four different types of loading arrangements is presented. Each loading arrangement has a different system for controlling the consistency of the loading condition. One of the loading arrangements used three units of link mechanism to control the parallelism of the top and bottom stub of column during testing, and the remaining employed eight hydraulic jacks for the same purpose. The loading systems condition used in this investigation were similar to the actual case in a moment-resisting frame where the tested column was displaced in a double curvature. Ten model column specimens, divided into four series were prepared. Two columns were tested monotonically until collapse, and unless failure took place at an earlier stage of loading, the remaining eight columns were tested under cyclic loading. Test results indicated that the proposed system to keep the top and bottom stubs parallel during testing performed well.