• 제목/요약/키워드: two-point loading

검색결과 270건 처리시간 0.026초

Energy dissipation response of brick masonry under cyclic compressive loading

  • Senthivel, R.;Sinha, S.N.
    • Structural Engineering and Mechanics
    • /
    • 제16권4호
    • /
    • pp.405-422
    • /
    • 2003
  • Scaled brick masonry panels were tested under cyclic unialxial compression loading to evaluate its deformation characteristics. An envelope stress - strain curves, a common point curves and stability point curves were obtained for various cyclic test conditions. Loops of the stress-strain hysteresis were used to determine the energy dissipation for each cycle. Empirical expressions were proposed for the relations between energy dissipation and envelope and residual strains. These relations indicated that the decay of masonry strength starts at about two-third of peak stress.

실내평가기법에서 하중재하지점에 따른 레티스거더의 성능분석 (Perfomance of Lattice Girder on Loading Point in Laboratory Test)

  • 김동규;이성호;최영남
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1526-1531
    • /
    • 2008
  • The objective of this study is to evaluate the loading capacity of lattice girder according to loading position. 3-point flexible strength tests were performed on three types of lattice girder, such as LG-$50{\times}20{\times}30$, LG-$70{\times}20{\times}30$, and LG-$95{\times}22{\times}32$, mainly used in Korea. Two types of loading position for each flexible strength test were used to analyze the behavior of load-deformation. In 3-point flexible strength test, the difference of the average of maximum flexible strength according to loading position had the range from 10% to 33%.

  • PDF

과실(果實)의 힘-변형(變形) 특성(特性) (Force-Deformation Characteristics of the Fruit Flesh)

  • 김만수;박종민;최동수
    • Journal of Biosystems Engineering
    • /
    • 제17권2호
    • /
    • pp.156-170
    • /
    • 1992
  • The force-deformation relationship gives the basic physical properties of the fruits such as the bioyield point, the rupture point, and the deformations at the bioyield point and the rupture point. These informations are very important to study the stress-strain relationships of the fruits. This study was conducted to analyze those physical properties according to the sampling position of the fruits, and to determine the bioyield point, the rupture point, and the deformations at the bioyield point and the rupture point of the fruits for two different storage conditions(low temperature and normal temperature) and the storage period, and to investigate the effect of loading rate on those physical properties, the hysteresis on the loading-unloading condition and the degree of elasticity of the fruits. The results of the study were as follows : 1. The physical properties(BS, US, BD, and RD) of the test specimen selected from the different sampling positions were quite different. The values of the physical properties were shown smallest ones at the cheek of the fruits, and the statistical test results of the physical properties between the cheek from the other two positions of the fruits showed that there were significant difference at the 1 % level between them. 2. The effect of loading rate on the physical properties of the fruits was relatively large, all the considered physical propertis of the fruits increased with the loading rate, but the hysteresis loss decreased with it. 3. The physical properties of the fruits according to the storage conditions and period showed different, and the bioyield deformation and the rupture deformation of the fruits increased with the storage period, but the bioyield strength and the ultimate strength of the fruits decreased with it. The effect of the storage conditions on the those physical properties showed that the normal temperature storage condition was a little higher than the low temperature storage condition. 4. As a whole, it was shown that the bioyield strength and the ultimate strength of the pear decreased a little faster than those of the apple, and the bioyield deformation and rupture deformation of the pear increased a little faster than those of apple at the two storage conditions.

  • PDF

통신해양기상위성의 휠오프로딩 지상국 소프트웨어 검증시험 (Ground Software Validation Test for Wheel Off-loading of COMS)

  • 박영웅;양군호
    • 항공우주기술
    • /
    • 제9권2호
    • /
    • pp.51-56
    • /
    • 2010
  • 통신해양기상위성의 정상임무 수행시 자세제어계에 대한 중요한 지상국 소프트웨어에는 궤도위치 유지와 휠오프로딩이 있는데, 본 논문에서는 외팔보 태양전지판 형상으로 인해 E3000 heritage로부터 설계 변경을 수행하여 해석을 수행한 휠오프로딩 임무에 대한 지상국 소프트웨어 검증시험을 정리하여 기술하였다. 휠오프로딩 지상국 소프트웨어는 크게 2가지로 구분되는데, 하나는 휠오프로딩을 위한 추력기 조합 변경 시기에서의 변수 변경이고 다른 하나는 위성으로 전달해야 하는 모멘텀기준값 변경이다.

다양한 회귀분석을 통한 강우유출용적에 따른 비점오염부하량 예측방안 (Predictive Relationships of the Nonpoint Source Pollutant Loads with Stormwater Runoff Volumes based on the Various Regression Analyses)

  • 신지웅;길경익
    • 한국물환경학회지
    • /
    • 제27권3호
    • /
    • pp.257-263
    • /
    • 2011
  • This study analyzes the correlations between non-point sources and runoff to estimate non-point sources for effective management. From the monitoring results, the correlation factors among pollutant mass loading, EMC, total runoff volume and average flow are calculated. And using correlation factors, the most related two constituents are determined. Also the most appropriate regression between two constituents are determined. Pollutant mass loading and total runoff volume has the highest correlation. Also, compound regression is found to be the most appropriate regression. This shows that pollutant mass loading increases as total runoff volume increases. It is not continuous increase but has some pattern.

An Experimental Study on Fracture Energy of Plain Concrete

  • Lee, Jaeha;Lopez, Maria M.
    • International Journal of Concrete Structures and Materials
    • /
    • 제8권2호
    • /
    • pp.129-139
    • /
    • 2014
  • In this study, the concrete fracture energy was obtained using the three point notched beam test method developed by Hillerborg et al. (Cem Concr Res 6(6):773-782, 1976). A total of 12 notched concrete beams were tested under two different loading conditions: constant stroke control and constant crack mouth opening displacement (CMOD) control. Despite individual fracture energies obtained from the two different loading conditions showing some variation, the average fracture energy from both loading conditions was very similar. Furthermore, the results obtained support the idea that a far tail constant "A" could change the true fracture energy by up to 11 %, if it is calculated using CMOD instead of LVDT. The far tail constant "A" is determined using a least squares fit onto a straight line according to Elices et al. (Mater Struct 25(148):212-218, 1992) and RILEM report (2007). It was also observed that the selection of the end point can produce variations of the true fracture energy. The end point indicates the point in the experiment at which to stop. An end point of 2 mm has been recommended, however, in this study other end points were also considered. The final form of the bilinear softening curve was determined based on Elices and Guinea's methods (1992, 1994) and RILEM report (2007). This paper proposes a bilinear stress-crack opening displacement curve according to test results as well as the CEB-FIP model code.

영천호에서 남조류 발생과 환경요인의 관련성 연구 (A Study on the Relationship between Cyanobacteria and Environmental Factors in Yeongcheon Lake)

  • 이현미;신라영;이정호;박종근
    • 한국물환경학회지
    • /
    • 제35권4호
    • /
    • pp.352-361
    • /
    • 2019
  • The purpose of this study is to analyze the characteristics and correlations of the Yeongcheon Lake in order to reduce the occurrence of harmful cyanobacteria. In this study, we investigated the water quality and phytoplankton of the lake from May to November in 2017. Correlation and data mining analyses were performed to analyze the relationship between the two factors. The water temperature was lowest at the point where the Yeongcheon Lake inflow occurs at Imha Lake. It was highest at the point where the outflow occurs to Angye Lake. The pH was also highest at the outflow point, but in the case of DO, it was highest at the midpoint between the inflow and outflow. The main cyanobacteria that emerged during the study period were Oscillatorialimosa, Microcysti saeruginosa and Aphanizomenon flos-aquae. As a result of correlation analysis, the water temperature, inflow, COD loading, TOC loading at the inflow point of the Yeongcheon Lake were the items that were related to the harmful cyanobacteria. The data mining analysis indicated that the TP loading and harmful cyanobacteria in the inflow point of the Yeongcheon Lake were influential on the detrimental cyanobacteria in the Yeongcheon Lake outflow point. When the TP loading was less than 39.0 kg/day at the inflow site, it was expected that the amount of harmful cyanobacteria could be maintained below 10,000 cells/mL.

격자지보재(Lattice Girder)의 실내성능평가기법 개발 (Development of a laboratory testing method for evaluating the loading capability of lattice girder)

  • 김동규;배규진
    • 한국터널지하공간학회 논문집
    • /
    • 제10권4호
    • /
    • pp.371-382
    • /
    • 2008
  • 본 연구의 목적은 국내터널현장에서 강지보재로 주로 사용되어지고 격자지보재(Lattice Gilder)의 공학적인 성능을 보다 객관적으로 판단하기 위한 실내성능평가기법의 제안에 있다. 본 연구를 위하여 국내에서 격자지보재로 주로 사용되는 $LG-50{\times}20{\times}30$, $LG-70{\times}20{\times}30$, 및 $LG-95{\times}22{\times}32$를 사용하여 3-point 휨강도 실험 및 4-point 휨강도 실험을 수행하였다. 또한, 하중재하위치에 따른 격자지보재의 하중-변위거동을 분석하기 위하여 각각의 실험방법에서 두 가지 하중재하방식을 사용하여 실험을 수행하였다. 각 부재에 스트레인 게이지를 부착하여 각각의 실험방법에 따라 각 부재에 작용하는 하중분포를 분석하였다. 3-point 휨강도 실험에 적용한 두 가지 하중재하방식으로 측정된 평균 최대하중은 $10%{\sim}33%$까지 차이가 나타났으며, 4-point 휨강도 실험에 적용한 두 가지 하중재하방식에 의해 측정된 평균 최대하중은 거의 차이가 없었다. 4-point 휨강도 실험의 평균 최대하중은 3-point 휨강도 실험보다 $13.56%{\sim}31.55%$와 정도 크게 나타났다. 3-point 휨강도 실험은 주강봉에 주로 하중이 집중되는 반면 4-point 휨강도 실험은 각 부재로 비교적 골고루 하중이 작용하는 것으로 나타났다.

  • PDF

Flexural studies on reinforced geopolymer concrete beams under pure bending

  • Sreenivasulu, C.;Jawahar, J. Guru;Sashidhar, C.
    • Advances in concrete construction
    • /
    • 제8권1호
    • /
    • pp.33-37
    • /
    • 2019
  • The present investigation is mainly focused on studying the flexural behavior of reinforced geopolymer concrete (RGPC) beams under pure bending. In this study, copper slag (CS) was used as a partial replacement of fine aggregate. Sand and CS were blended in different proportions (100:0, 80:20, 60:40 and 40:60) (sand:CS) by weight. Fly ash and ground granulated blast furnace slag (GGBS) were used as binders and combination of sodium hydroxide (8M) and sodium silicate solution were used for activating the binders. The reinforcement of RGPC beam was designed as per guidelines given in the IS 456-2000 and tested under pure bending (two-point loading) after 28 days of ambient curing. After conducting two point load test the flexural parameters viz., moment carrying capacity, ultimate load, service load, cracking moment, cracking load, crack pattern and ultimate deflection were studied. From the results, it is concluded that RGPC beams have shown better performance up to 60% of CS replacement.

Flexural performance of double skin composite beams at the Arctic low temperature

  • Yan, Jia-Bao;Dong, Xin;Wang, Tao
    • Steel and Composite Structures
    • /
    • 제37권4호
    • /
    • pp.431-446
    • /
    • 2020
  • This paper presents the flexural performance of double skin composite beams (DSCBs) at different Arctic low temperatures. 12 DSCBs were prepared and tested under two-point loading at different Arctic low temperatures of 20, -30, -50, and -70℃. The studied parameters include low-temperature level (T), steel-faceplate thickness (t), shear span ratio (λ), and spacing of headed studs (S). The experimental investigations under two-point loading tests showed that flexural failure occurred to all DSCBs, even including the specimen designed with the small λ ratio of 2.9. The ultimate strength behaviours of DSCBs were improved due to the improved mechanical properties of constructional materials and the confinement on shear connectors. The DSCB subjected to two-point loading and low temperatures exhibits a five-stage working mechanism. The stiffness and strength indexes of DSCBs increase linearly with temperature and t value increasing, while decreasing as shear span ratio boosts. In the contrast, the change of S value from 150 to 200 mm has little effect on the ultimate strength behavior of DSCB.