• 제목/요약/키워드: two-phase system

검색결과 2,663건 처리시간 0.034초

Analysis of Decoupling Method in DQ Transform-based for Grid Connected Inverter

  • Windarko, Novie Ayub;Lee, Jin-Mok;Choi, Jae-Ho
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.924-925
    • /
    • 2008
  • There are many types of grid-connected inverter controllers, PI controller based is the most popular methods. But, a common PI control is produced zero-steady state error and phase delay in sinusoidal reference. Synchronous reference frame or DQ transform based controller is capable for reducing both of zero-steady state error and phase delay is. But DQ transform based controller has cross-coupling component which difficult to analyze the system in single phase model. In this paper, to obtained single phase model of the system, DQ transform based controller is analyzed in two techniques. The first is by neglecting cross-coupling. The second is eliminated cross-coupling component by decoupling method. By these two techniques, single phase model is obtained. Then, the single phase model is analyzed to evaluate its performance in stability and frequency response, through Root Locus and Bode diagram, respectively. MATLAB and PSIM simulation is used to verify the analysis. Simulation result is shown; cross-coupling component has no significant influent to the controller.

  • PDF

회분식 반응기에서 반응폭주에 의한 2-Phase 흐름 파열판 설계 및 적용에 관한 연구 (A Study on the Rupture Disk Design and Application at the Two Phase Flow by Runaway Reaction at Batch Reactor)

  • 이형섭;윤희창
    • 한국가스학회지
    • /
    • 제21권3호
    • /
    • pp.1-8
    • /
    • 2017
  • 이 연구의 목적은 회분식 반응기에서 반응폭주에 의하여 2상(기상-액상)에서 적용가능한 파열판의 크기를 설계하는 방안을 제시하는 것이다. 반응폭주의 정의는 제어가 되지 않은 냉각수 투입불가 또는 운전조건의 이탈에 의한 비정상적으로 발열반응을 말한다. 이 결과로 반응기의 온도는 급격히 증가하게 된다. 반응폭주의 원인은 크게 자기과열반응과 지연반응으로 구분한다. 일반적인 안전밸브나 파열판의 내경 크기로는 폭주반응시에는 적절하게 압력을 해소할 수 없다. 폭주반응 시 반응온도 및 압력이 급격하게 증가하기 때문에 안전밸브로 분출되는 내용물은 2상이다. 이 연구에서는 최근 회분식 반응기의 폭주반응으로 인하여 사고사례의 원인을 분석하고, 2 상으로 분출현상 및 특징을 설정하고, 이에 적절한 파열판의 크기를 설계하여 적용하는 방안을 제시하고자 한다.

Thermodynamic Assessment of the PbO-ZrO2 System

  • Koo, Bon-Keup;Ping Liang;Hans Jiirgen Seifert;Fritz Aldinger
    • The Korean Journal of Ceramics
    • /
    • 제5권3호
    • /
    • pp.205-210
    • /
    • 1999
  • The thermodynamic properties and phase diagram of the$ PbO-ZrO_2$ system have been critically assessed using the Thermo-Calc program. Excess Gibbs energies were expressed by Redlich-Kister polynomials for the solid phases, by the two-sublattice ionic liquid model for the liquid phase and by the compound energy model for the solid solution phase. All solid phases were treated as stoichimetric compounds.

  • PDF

고농도 Indole 내성 Pseudomonas savastanoi BCNU 106에 의한 Indigo 및 Indirubin의 생산

  • 최리나;차문정;박정욱;주우홍
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.470-473
    • /
    • 2000
  • Indole은 미생물에 강한 독성을 가지고 있으므로 indole의 생물학적 전환이 어려우므로 단지 소수의 미생물들이 Indole이나 그것의 연관물질들로부터 Indigo와 Indirubin을 생산하는데 응용되어 왔다. 본 연구실에서 분리된 Pseudomonas savastanoi BCNU 106은 toluene에 강한 내성을 가졌으며 P. savastanoi BCNU 106의 Indole 내성 정도는 p-xylene이나 toluene이 배지 부피의 20% 로 첨가되었을 때 160 mg/ml로 매우 높은 내성 정도를 나타내었다. Indole (100 mg/ml) 과 p-xylene (0.2 ml/ml)을 포함한 two-phase culture system에서 자란 P. savastanoi BCNU 106은 indole로부터 푸른색 indigo나 보라색 indirubin의 미생물학적 전환을 보여주었다. indigo와 indirubin의 생산은 P. savastanoi BCNU 106가 적절한 농도의 유기용매가 중층된 two-phase system에서 자랐을 경우에만 형성되었다. 그러므로 본 연구는, 분리된 indole 내성 세균이 유기용매하에서 indirubin과 같은 산업적 가치를 가진 유용물질을 생산하는데 응용될 수 있을 것으로 사료된다.

  • PDF

2단 3상 PWM AC/DC 컨버터를 이용한 동기발전기 여자제어시스템 (A Study on Excitation System for Synchronous Generator Using Two State Three Phase PWM AC/DC Converter)

  • 이상훈;이동희;안진우
    • 조명전기설비학회논문지
    • /
    • 제21권3호
    • /
    • pp.96-106
    • /
    • 2007
  • 동기발전기의 출력전압은 여자 시스템의 계자 전류 제어에 의해 일정하게 유지된다. 현재 대부분의 발전기 여자기의 여자전류제어를 위해 사용되는 AVR 시스템의 AC/DC 컨버터 부는 출력전압 제어가 가능한 위상제어 컨버터나 출력전압을 제어할 수 없는 다이오드 정류기와 DC/DC 컨버터를 결합하여 사용하고 있다. AC/DC 전력 변환장치로서 위상제어 컨버터나 출력전압을 제어할 수 없는 다이오드 정류기의 경우, AVR시스템의 전력을 공급하는 모선의 역률저하 및 저차 고조파 발생의 문제점을 야기 시키게 된다. 본 논문에서는 동기발전기의 여자전류 제어를 위해 사용되는 AVR 시스템 설계에 있어 단위역률 동작이 가능한 Boost형 AC/DC 컨버터와 모선의 부하변동에 속응성 있게 동작할 수 있는 전류 제어형 Buck 컨버터를 결합한 2단 3상 PWM AC/DC 컨버터에 대해 연구하였다. 제안된 AC/DC 컨버터를 시뮬레이션 한 결과 Boost 컨버터의 경우 단위 역률 동작 및 출력 DC 전압의 Boost 동작이 원할히 이루어졌으며, Buck 컨버터의 경우 다른 위상제어 컨버터에 비해 응답시간이 개선되었음을 알 수 있었다.

교류 AT급전방식에서 병렬급전시 변전소간 전압위상차에 의한 루프전류에 관한 연구 (A Study on the Loop Current Induced by Voltage Phase Difference Substations during Parallel Feeding under the Alternating Current AT Electric Power Feeding Method)

  • 박재석;송중호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1997-2004
    • /
    • 2011
  • The $2{\times}25kv$ AT electric power feeding method in the A.C. electric train adopts the one-phase power feeding method as the standard due to a voltage phase difference, and the distance between the two neighboring substations is 50km due to voltage drop. The one-phase power feeding method makes the system operation feasible, while making it unfavorable for power supply. Moreover, railroad involves large-capacity single-phase load, and if it is expected to continue to rise, it is necessary to research on measures to stabilize the supply of power to railroad cars with the existing facilities. In this study, a parallel power feeding method between neighboring substations is proposed to stabilize the supply of electric power to electric railroad cars under the 2*25kv AT power feeding method and the loop current induced by voltage phase difference between the two neighboring substations during parallel power feeding is investigated.

  • PDF

ACCURACY AND EFFICIENCY OF A COUPLED NEUTRONICS AND THERMAL HYDRAULICS MODEL

  • Pope, Michael A.;Mousseau, Vincent A.
    • Nuclear Engineering and Technology
    • /
    • 제41권7호
    • /
    • pp.885-892
    • /
    • 2009
  • This manuscript will discuss a numerical method where the six equations of two-phase flow, the solid heat conduction equations, and the two equations that describe neutron diffusion and precursor concentration are solved together in a tightly coupled, nonlinear fashion for a simplified model of a nuclear reactor core. This approach has two important advantages. The first advantage is a higher level of accuracy. Because the equations are solved together in a single nonlinear system, the solution is more accurate than the traditional "operator split" approach where the two-phase flow equations are solved first, the heat conduction is solved second and the neutron diffusion is solved third, limiting the temporal accuracy to $1^{st}$ order because the nonlinear coupling between the physics is handled explicitly. The second advantage of the method described in this manuscript is that the time step control in the fully implicit system can be based on the timescale of the solution rather than a stability-based time step restriction like the material Courant limit required of operator-split methods. In this work, a pilot code was used which employs this tightly coupled, fully implicit method to simulate a reactor core. Results are presented from a simulated control rod movement which show $2^{nd}$ order accuracy in time. Also described in this paper is a simulated rod ejection demonstrating how the fastest timescale of the problem can change between the state variables of neutronics, conduction and two-phase flow during the course of a transient.

Metamaterial 전송선로를 이용한 4출력 90° 위상 분배기 (4 Way Quadrature Divider Using Metamaterial Transmission Lines)

  • 조학래;김정표;구경헌
    • 한국항행학회논문지
    • /
    • 제22권2호
    • /
    • pp.141-147
    • /
    • 2018
  • 본 논문에서는 $90^{\circ}$ 위상차를 갖는 GNSS (global navigation satellite system)용 광대역 4출력 분배 회로를 제안한다. 제안하는 분배회로는 1개의 발룬과 2개의 $90^{\circ}$ 위상 분배기로 이루어진다. 발룬은 wilkinson 분배기와 두 출력단에 각각 ${\pm}90^{\circ}$ metamaterial 전송선 위상 천이기를 이용하여 구현된다. $90^{\circ}$ 위상 분배기의 경우, 발룬과 구조는 같으나, 두 개의 출력단에 각각 ${\pm}45^{\circ}$ metamaterial 전송선 위상천이기가 적용된다. Metamaterial 전송선은 LCL-TL (LC loaded transmission line) 단위 셀을 이용하여 구현하였으며, 요구되는 위상 천이 특성을 구현하기 위해 5셀을 갖도록 하였다. 구현된 4출력 $90^{\circ}$ 위상 분배기는 GNSS 대역인 1.165 -1.61 GHz의 넓은 대역에서 각 포트별 $90^{\circ}{\pm}10^{\circ}$의 위상차를 갖는다.

기준전류추정형 인버어터에 의한 2 권선전동기의 2 상운전특성 (Characteristics of Two Phase Operation of Two Winding Motor Driven by Reference Current Adaptive Inverter)

  • 원종수;정의상
    • 대한전기학회논문지
    • /
    • 제33권8호
    • /
    • pp.289-298
    • /
    • 1984
  • The single phase induction motor is recently requested to meet a broad speed control and smooth forward and reverse operation due to the multifarious usages. This paper deals with two phase operation of a two winding motor by reference current adaptive inverter which can supply the currents to satisfy the balanced oeration into the main and auxiliary winding through the entire operational region. According to the roposed system, the starting, forward and reverse and variable speed control of a two winding motor eliminated the capacitor from the capacitor-run motor is also possible. The formation and its principle of the reference current adaptive inverter and characteristic analysis of the motor fed by this apparatus are described in this paper. Excellent agreement with the measured results and calculated values by computer simulation is obtained.

  • PDF

비정렬격자계에서 과도 이상유동해석을 위한 수치해법 (HYDRODYNAMIC SOLVER FOR A TRANSIENT, TWO-FLUID, THREE-FIELD MODEL ON UNSTRUCTURED GRIDS)

  • 정재준;윤한영;김종태;박익규;조형규
    • 한국전산유체공학회지
    • /
    • 제12권4호
    • /
    • pp.44-53
    • /
    • 2007
  • A three-dimensional (3D) unstructured hydrodynamic solver for transient two-phase flows has been developed for a 3D component of a nuclear system code and a component-scale analysis tool. A two-fluid three-field model is used for the two-phase flows. The three fields represent a continuous liquid, an entrained liquid, and a vapour field. An unstructured grid is adopted for realistic simulations of the flows in a complicated geometry. The semi-implicit ICE (Implicit Continuous-fluid Eulerian) numerical scheme has been applied to the unstructured non-staggered grid. This paper presents the numerical method and the preliminary results of the calculations. The results show that the modified numerical scheme is robust and predicts the phase change and the flow transitions due to boiling and flashing very well.