• 제목/요약/키워드: two-phase fluid flow

검색결과 466건 처리시간 0.024초

Eulerian-Lagrangian 다상 유동해석법에 의한 피에조인젝터의 니들-노즐유동 상관성 연구 (A Study on Relation of Needle-Nozzle Flow of Piezo-driven Injector by using Eulerian-Lagrangian Multi-phase Method)

  • 이진욱;민경덕
    • 한국자동차공학회논문집
    • /
    • 제18권5호
    • /
    • pp.108-114
    • /
    • 2010
  • The injection nozzle of an electro-hydraulic injector is being opened and closed by movement of a injector's needle which is balanced by pressure at the nozzle seat and at the needle control chamber, at the opposite end of the needle. In this study, the effects of needle movement in a piezo-driven injector on unsteady cavitating flows behavior inside nozzle were investigated by cavitation numerical model based on the Eulerian-Lagrangian approach. Aimed at simulating the 3-D two-phase flow behavior, the three dimensional geometry model along the central cross-section regarding of one injection hole with real design data of a piezo-driven diesel injector has been used to simulate the cavitating flows for injection time by at fully transient simulation with cavitation model. The cavitation model incorporates many of the fundamental physical processes assumed to take place in cavitating flows. The simulations performed were both fully transient and 'pseudo' steady state, even if under steady state boundary conditions. As this research results, we found that it could analyze the effect the pressure drop to the sudden acceleration of fuel, which is due to the fastest response of needle, on the degree of cavitation existed in piezo-driven injector nozzle.

새로운 응고 모델을 적용한 Czocgralski 단결정 성장 공정 모사 (The Transient Simulation of Czochralski Single Crystal Growth Process Using New Solidification Model)

  • 이경우;윤종규
    • 한국결정성장학회지
    • /
    • 제1권1호
    • /
    • pp.74-81
    • /
    • 1991
  • Czochralski 단결정 성장계에서 유체동의 표면 복사열전달을 고려하여 온도분포를 모사하였다. 복사열전달 고려시 표면요소들의 view factor를 고려하였다. 고-액의 2상은 고상에 가상적으로 매우 큰 점성을 부여하여 연속의 단상으로 처리하였으며 응고시 잠열은 반복열량 방출법을 개발하여 처리하였다. 본 연구에서 개발한 응고 모델을 증명하기 위하여 Ca 금속의 용융에 적용하여 실험결과와 비교한 결과 잘 맞는다는 것을 알아낸 후 본 모사 프로그램을 Cz계에서 Al금속의 단결정 성장에 적용하였다.

  • PDF

레벨셋 기법의 물성 보간 방법에 대한 고찰 (ASSESSMENT OF PROPERTY INTERPOLATION METHODS IN LEVEL SET METHOD)

  • 박준권;오정민;강관형
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.283-289
    • /
    • 2009
  • In level set method, material properties are made to change smoothly across an interface of two materials with different properties by introducing an interpolation or smoothing scheme. So far, the weighted arithmetic mean (WAM) method has been exclusively adopted in level set method, without complete assessment for its validity. We showed here that the weighted harmonic mean (WHM) method for rate constants of various rate processes, including viscosity, thermal conductivity, electrical conductivity, and permittivity, gives much more accurate results than the WAM method. The selection of interpolation scheme is particularly important in multi-phase electrohydrodynamic problems in which driving force for fluid flow is electrical force exerted on the phase interface. Our analysis also showed that WHM method for both electrical conductivity and permittivity gives not only more accurate, but also more physically realistic distribution of electrical force at the interface. Our arguments are confirmed by numerical simulations of drop deformation under DC electric field.

  • PDF

상변화 물질을 이용한 이동전화기의 냉각에 관한 연구 (A Study of Cooling of Mobile Phone Using PCM Module)

  • 이상진;정수진;김우승
    • 대한기계학회논문집B
    • /
    • 제29권11호
    • /
    • pp.1173-1181
    • /
    • 2005
  • The cooling effect of a mobile phone using PCM(Phase Change Material) module has been numerically investigated. A transient three-dimensional numerical analysis of heat and fluid flow with natural convection is performed in this study. Governing conservation equations for mass, momentum and energy are solved by an implicit finite volume method. An enthalpy-porosity technique has been used for modeling of the melting process. Two different ways of placing the PCM module are considered. One is to place a PCM module between the substrate and battery pack, and the other is to place a PCM module between MCM(multichip module) and battery pack. Three different types of PCMs are used to predict the performance of PCM. The results show that passive cooling with PCM can reduce the temperature rise and the effect of natural convection in PCM module considered in this study is negligible.

중력류 흐름에 대한 직접수치해석 (Direct Numerical Simulation of Gravity Currents)

  • 이재룡;;하만영
    • 대한기계학회논문집B
    • /
    • 제30권5호
    • /
    • pp.422-429
    • /
    • 2006
  • Resolved simulations are presented fur gravity current flows aiming at studying their spreading rate. The simulations are performed for two extreme configurations such as planar and cylindrical and for 3 different Grashof numbers: $10^5,\;1{\times}10^6\;and\;10^7$. Varying the size of the heavy fluid release, the study is performed for several phases of spreading, namely acceleration, slumping and inertial phases. For the simulations, efficient spectral multi-domain code is used. From the simulations results it is concluded that 2-D results predicts well the mean front velocity during the slumping phase, but fails to predict it during the inertial phase of spreading. It is also observed that the vortex dynamics of the flow is not reproduced well by the 2-D simulation.

감압법을 이용한 메탄하이드레이트 생산에 대한 수치적 연구 (Numerical Study on the Production of Methane Hydrate by Depressurization Method)

  • 김진홍;천원기;김남진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.519-523
    • /
    • 2007
  • Gas(or methane) hydrates are solid solutions when water molecules are linked through hydrogen bonding and create host lattice cavities that can enclose a large variety of guest gas molecules. The natural gas hydrate crystal may exist at low temperature above the normal freezing point of water and high pressure greater than about 30 bars. A lot of quantities of natural gas hydrates exists in the earth and many production schemes are being studied. In the present investigation, depressurization method was considered to predict the production of gas and the simulation of the two phase flow - gas and water - in porous media is being carried out. The simulation show about the fluid flow in porous media have a variety of applications in industry. Results provide the appearance of gas and water production, the pressure profile, the saturation of gas/ water/ hydrates profiles and the location of the pressure front.

  • PDF

Assessment of COBRA-TF for Critical Heat Flux

  • Chun, Tae-Hyun;Lim, Jong-Sun;Motoaki Okazaki
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.75-81
    • /
    • 1996
  • COBRA-TF is a two fluid, three field subchannel code. Three fields are continuous vapor, continuous liquid and droplet. Some assessments are conducted to validate the related models and to estimate a code ability through dryout and post-CHF experiment in a tube and DNB test in rod bundles. It turned out form dryout and post-CHF experiment that the predicted dryout locations and wall temperature profiles are in close agreement with the experiments. On the other hand, DNB prediction of COBRA-TF are performed for two kinds of rod bundles along with EPRI CHF correlation. To estimate its performance COBRA-IV of homogeneous model is also run for the same data. The results say that COBRA-TF/EPRI is better in DNB prediction than COBRA-IV/EPRI. In addition the thermal-hydraulic behaviors due to the different two-phase flow models are presented at the condition of CHF.

  • PDF

CHAINED COMPUTATIONS USING AN UNSTEADY 3D APPROACH FOR THE DETERMINATION OF THERMAL FATIGUE IN A T-JUNCTION OF A PWR NUCLEAR PLANT

  • Pasutto, Thomas;PENiguel, Christophe;Sakiz, Marc
    • Nuclear Engineering and Technology
    • /
    • 제38권2호
    • /
    • pp.147-154
    • /
    • 2006
  • Thermal fatigue of the coolant circuits of PWR plants is a major issue for nuclear safety. The problem is especially accute in mixing zones, like T-junctions, where large differences in water temperature between the two inlets and high levels of turbulence can lead to large temperature fluctuations at the wall. Until recently, studies on the matter had been tackled at EDF using steady methods: the fluid flow was solved with a CFD code using an averaged turbulence model, which led to the knowledge of the mean temperature and temperature variance at each point of the wall. But, being based on averaged quantities, this method could not reproduce the unsteady and 3D effects of the problem, like phase lag in temperature oscillations between two points, which can generate important stresses. Benefiting from advances in computer power and turbulence modelling, a new methodology is now applied, that allows to take these effects into account. The CFD tool Code_Saturne, developped at EDF, is used to solve the fluid flow using an unsteady L.E.S. approach. It is coupled with the thermal code Syrthes, which propagates the temperature fluctuations into the wall thickness. The instantaneous temperature field inside the wall can then be extracted and used for structure mechanics computations (mainly with EDF thermomechanics tool Code_Aster). The purpose of this paper is to present the application of this methodology to the simulation of a straight T-junction mock-up, similar to the Residual Heat Remover (RHR) junction found in N4 type PWR nuclear plants, and designed to study thermal striping and cracks propagation. The results are generally in good agreement with the measurements; yet, in certain areas of the flow, progress is still needed in L.E.S. modelling and in the treatment of instantaneous heat transfer at the wall.

AN EXPERIMENTAL STUDY ON POST-CHF HEAT TRANSFER FOR LOW FLOW OF WATER IN A $3\times3$ ROD BUNDLE

  • MOON SANG-KI;CHUN SE-YOUNG;CHO SEOK;KIM SE-YUN;BAEK WON-PIL
    • Nuclear Engineering and Technology
    • /
    • 제37권5호
    • /
    • pp.457-468
    • /
    • 2005
  • An experimental study on post-CHF heat transfer has been performed with a $3\times3$ rod bundle using a vertical steam-water two-phase flow at low flow conditions. The effects of various parameters on the post-CHF heat transfer are investigated and the reasons for the parametric effects are discussed. As the heat transfer regime changes from CHF to post-CHF, the radial wall temperature distribution is changed depending on the pressure and the mass flux conditions. The superheat of the fluid increases considerably with an increase of the wall temperature (or heat flux) and with a decrease of the mass flux. This implies, indirectly, a strong thermal non-equilibrium at high wall temperature and low mass flux conditions. In order to improve the prediction accuracy of the existing post-CHF correlations, it is necessary to perform more experiments, particularly direct measurement of the vapor superheat, and to modify the correlation by considering a strong thermal non-equilibrium at low flow and low pressure conditions.

다공성 매질에서 액화질소의 거동에 대한 연구 (STUDY ON BEHAVIOR OF LIQUID NITROGEN IN POROUS MEDIA)

  • 최성웅;이우일
    • 한국전산유체공학회지
    • /
    • 제18권2호
    • /
    • pp.17-25
    • /
    • 2013
  • The process of flow through porous media is of interest a wide range of engineering fields and areas, and the importance of fluid flow with a change in phase arises from the fact that many industrial processes rely on these phenomena for materials process, energy transfer. Especially, the flow phenomena of cryogenic liquid subjected to evaporation is of interest to investigate how the cryogenic liquid behaves in the porous structure. In this study, thermo physical properties, morphological properties of the glass wool with different bulk densities in terms of its temperature-dependence and permeability behaviors under different applying pressure are discussed. Using the experimentally determined properties, characteristics of two main experimental results are investigated. In addition, simulation results are used to realize the cryogenic liquid's flow in porous media, and are compared with experimental results. By using the experimentally determined properties, more reasonable results can be suggested in dealing with porous media flow.