• Title/Summary/Keyword: two-level resolution

Search Result 261, Processing Time 0.033 seconds

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

Recent Advances in Electron Crystallography

  • Chung, Jeong Min;Lee, Sangmin;Jung, Hyun Suk
    • Applied Microscopy
    • /
    • v.47 no.3
    • /
    • pp.160-164
    • /
    • 2017
  • Electron crystallography has been used as the one of powerful tool for studying the structure of biological macromolecules at high resolution which is sufficient to provide details of intramolecular and intermolecular interactions at near-atomic level. Previously it commonly uses two-dimensional crystals that are periodic arrangement of biological molecules, however recent studies reported a novel technical approach to electron crystallography of three-dimensional crystals, called micro electron-diffraction (MicroED) which involves placing the irregular and small sized protein crystals in a transmission electron microscope to determine the atomic structure. In here, we review the advances in electron crystallography techniques with several recent studies. Furthermore, we discuss the future direction of this structural approach.

Orthogonality Measurement of Square Plane Mirrors for Laser Interferometry (레이저 간섭계의 직각 평면거울에 대한 직각도 오차 측정)

  • 김태호;김승우
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.12
    • /
    • pp.169-179
    • /
    • 1998
  • Plane mirror type laser interferometers are popularly being used in many modern ultraprecision machines, as they can perform simultaneous measurements of multiple axis positions with nanometer resolution capabilities. One important issue in this application of laser interferometers is to provide a good level of alignment between the reflecting mirrors and the laser beams so that measurement errors due to undesirable coupling effects can be avoided in multiple axis measurements In this investigation, a thorough metrological analysis is given to develop an suitable mathematical model for a precision x-y stage in which the orthogonality misalignment between the reflecting mirrors significantly affects overall x-y mea-surement results. Then a noble calibration method is suggested in which two-dimensional displacement sensors of moire gratings of concentric circles are used to realize the reversal principle of orthogonality evaluation in situ. Finally, actual experimental results are discussed to verify that the suggested method can effectively calibrate the orthogonality error with an uncertainty of 0.2667 arcsec.

  • PDF

Electrical Power and Energy Reference Measurement System with Asynchronous Sampling (비동기 샘플링에 의한 전력과 에너지 측정 기준시스템)

  • Wijesinghe, W.M.S.;Park, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.684_685
    • /
    • 2009
  • A digital sampling algorithm that uses a two high resolution integrating Voltmeters which are synchronized by Phase Lock Loop (PLL) time clock for accurately measuring the parameters, active and reactive power, for sinusoidal power measurements is presented. The PLL technique provides high precision measurements, root mean square (rms), phase and complex voltage ratio, of the AC signal. The system has been designed to be used at the Korean Research Institute of Standards and Science (KRISS) as a reference power standard for electrical power calibrations. The test results have shown that the accuracy of the measurements is better than $10 {\mu}W/VA$ and the level of uncertainty is valid for the power factor range zero to 1 for both lead and lag conditions. The system is fully automated and allows power measurements and calibration of high precision wattmeters and power calibrators at the main power frequencies 50 and 60 Hz.

  • PDF

Development of a Miniature Air-bearing Stage with a Moving-magnet Linear Motor

  • Ro, Seung-Kook;Park, Jong-Kweon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.1
    • /
    • pp.19-24
    • /
    • 2008
  • We propose a new miniature air-bearing stage with a moving-magnet slotless linear motor. This stage was developed to achieve the precise positioning required for submicron-level machining and miniaturization by introducing air bearings and a linear motor sufficient for mesoscale precision machine tools. The linear motor contained two permanent magnets and was designed to generate a preload force for the vertical air bearings and a thrust force for the stage movement. The characteristics of the air bearings, which used porous pads, were analyzed with numerical methods, and a magnetic circuit model was derived for the linear motor to calculate the required preload and thrust forces. A prototype of a single-axis miniature stage with dimensions of $120\;(W)\;{\times}\;120\;(L)\;{\times}\;50\;(H)\;mm$ was designed and fabricated, and its performance was examined, including its vertical stiffness, load capacity, thrust force, and positioning resolution.

Calibration of SAW Based Capacitive Sensor Using Lumped Component and High Precision Gap Measurement (집중 소자를 이용한 표면 탄성파 장치 기반의 용량 성 센서 보정 및 이를 이용한 초정밀 간극 측정)

  • Kim, Jae-Geun;Ko, Byung-Han;Park, Young-Pil;Park, No-Cheol
    • Transactions of the Society of Information Storage Systems
    • /
    • v.8 no.1
    • /
    • pp.16-21
    • /
    • 2012
  • SAW device is widely used as filters, sensors, actuators in various technologies. And capacitive sensor is tremendously used to measure pressure, gap, etc. The application of SAW device as signal conditioner of capacitive sensor reduces noise level and enables high precision measurement. The response increase of SAW based capacitive sensor is produced just before the two capacitive electrode contacts by the existence of parasitic resistance of capacitive electrode. In this paper, we analyze the effects of parasitic resistance and propose the calibrating method using lumped component and execute the high precision gap measurement using calibrated system. And xx nm resolution and yy ${\mu}m$ stroke was attained.

TDES CODER USING SSE2 TECHNOLOGY

  • Koo, In-Hoi;Kim, Tae-Hoon;Ahn, Sang-Il
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.114-117
    • /
    • 2007
  • DES is an improvement of the algorithm Lucifer developed by IBM in the 1977. IBM, the National Security Agency (NSA) and the National Bureau of Standards (NBS now National Institute of Standards and Technology NIST) developed the DES algorithm. The DES has been extensively studied since its publication and is the most widely used symmetric algorithm in the world. But nowadays, Triple DES (TDES) is more widely used than DES especially in the application in case high level of data security is required. Even though TDES can be implemented based on standard algorithm, very high speed TDES codec performance is required to process when encrypted high resolution satellite image data is down-linked at high speed. In this paper, Intel SSE2 (Streaming SIMD (Single-Instruction Multiple-Data) Extensions 2 of Intel) is applied to TDES Decryption algorithm and proved its effectiveness in the processing time reduction by comparing the time consumed for two cases; original TDES Decryption and TDES Decryption with SSE2

  • PDF

A 3.3V 10BIT CURRENT-MODE FOLDING AND INTERPOLATING CMOS AJ D CONVERTER USING AN ARITHMETIC FUNCTIONALITY

  • Chung, Jin-Won;Park, Sung-Yong;Lee, Mi-Hee;Yoon, Kwang-Sub
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.949-952
    • /
    • 2000
  • A low power 10bit current-mode folding and interpolating CMOS analog to digital converter (ADC) with arithmetic folding blocks is presented in this paper. A current-mode two-level folding amplifier with a high folding rate (FR) is designed not only to prevent ADC from increasing a FR excessively, but also to perform a high resolution at a single power supply of 3.3V The proposed ADC is implemented by a 0.6${\mu}$m n-well CMOS single poly/double metal process. The simulation result shows a differential nonlinearity (DNL) of ${\pm}$0.5LSB, an integral nonlinearity (INL) of ${\pm}$1.0LSB

  • PDF

Landscape pattern analysis from IKONOS image data by wavelet and semivariogram method

  • Danfeng, Sun;Hong, Li
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1209-1211
    • /
    • 2003
  • The wavelet and semivariogram analysis method are used to identify the city landscape and farmland landscape pattern on the 1m resolution IKONOS images. The results prove that wavelet method is a potential way for landscape pattern analysis. Compared to semivariogram analysis, Wavelet analysis can not only detect the overall spatial pattern, but also find multi-scale and direction structures. In this experiment, the wavelet analysis results indicate: (1) the city landscape image is mainly composed of three level structures whose spatial pattern characters appear at 2m, 16m, 128m and 256m accordingly; (2) the farmland landscape is mainly two scale spatial patterns appearing at the 2m, 128m and 256m. IKONOS Remote sensing, with the high spatial and spectral information, is a powerful tool that can use in many ecological systems research and sustainable management.

  • PDF

CTF/DYN3D multi-scale coupled simulation of a rod ejection transient on the NURESIM platform

  • Perin, Yann;Velkov, Kiril
    • Nuclear Engineering and Technology
    • /
    • v.49 no.6
    • /
    • pp.1339-1345
    • /
    • 2017
  • In the framework of the EU funded project NURESAFE, the subchannel code CTF and the neutronics code DYN3D were integrated and coupled on the NURESIM platform. The developments achieved during this 3-year project include assembly-level and pin-by-pin multiphysics thermal hydraulics/neutron kinetics coupling. In order to test this coupling, a PWR rod ejection transient was simulated on a MOX/UOX minicore. The transient is simulated using two different models of the minicore. In the first simulation, both codes model the core with an assembly-wise resolution. In the second simulation, a pin-by-pin fuel-centered model is used in CTF for the central assembly, and a pin power reconstruction method is applied in DYN3D. The analysis shows the influence of the different models on global parameters, such as the power and the average fuel temperature, but also on local parameters such as the maximum fuel temperature.