A zero voltage switching (ZVS) three level resonant pole inverter is presented for high power GTO inverters. The concept of auxiliary resonant commutated pole(ARCP) for two level inverter is extended to the three level inverter. The proposed auxiliary commutation circuit consists of one resonant inductor and two bi-directional switches, which provides ZVS condition to the main devices without increasing device voltage or current stresses. The auxiliary device operates with zero current switching(ZCS) which enables use of the low cost thyristors. The proposed circuit can handle higher voltage and higher power(1-10MVA) comparing to the two level one. Operation and analysis of the proposed circuit are illustrated. Experimental results with 10 KW, 4 kHz prototype are presented to verify the principle of operation.
It is very important to understand and interpret the meaning of the sigma level correctly through the Six Sigma project. Especially, the confusion over the relation between sigma level from the short-term point of view and defective proportion or DPMO from the long-term point of view may make a big gap between expected results of the Six Sigma project and real results in the field. The one-tail approximation is commonly used to calculate the sigma level both in most literatures introducing Six Sigma and actual cases of the Six Sigma project. Since the one-tail approximation undervalues the sigma level of the fields such as business and service of which the sigma level is generally low, however. there can be misleading results of the explanation of the sigma level and inappropriate project evaluation. This paper describes the relation between sigma level and defective proportion in detail and clears the difference between the one-tail and two-tail approximation.
To increase the sensitivity of film-type level sensors for water-level measurements, a Wheatstone bridge comprising a half-bridge circuit with a new film-type level sensor design containing four resistors and two electrodes was employed. The proposed film-type level sensor included a temperature compensation feature and demonstrated improved sensitivity owing to a two-fold increase in the voltage output. Furthermore, a repetition error of less than 1.0% was observed for water levels. As the change in resistance varied linearly with the water level, a linear function was derived to represent their relation. Using this derived formula, water level measurements that were twice as precise as those yielded by commercial products were achieved.
This study examines the two-level behavior of the toggle brace damper within a steel frame having a yielding pipe damper and rotational friction damper. The proposed system has two kinds of fuse for energy dissipation in two stages. In this mechanism, rotational friction damper rather than hinged connection is used in toggle brace system, connected to a pipe damper with a limited gap. In order to create a gap, bolted connection with the slotted hole is used, such that first a specific movement of the rotational friction damper solely is engaged but with an increase in movement, the yielding damper is also involved. The performance of the system is such that at the beginning of loading the rotational friction damper, as the first fuse, absorbs energy and with increasing the input load and further movement of the frame, yielding damper as the second fuse, along with rotational friction damper would dissipate the input energy. The models created by ABAQUS are subjected to cyclic and seismic loading. Considering the results obtained, the flexibility of the hybrid two-level system is more comparable to the conventional toggle brace damper. Moreover, this system sustains longer lateral displacements. The energy dissipation of these two systems is modeled in multi-story frames in SAP2000 software and their performance is analyzed using time-history analysis. According to the results, permanent relocations of the roof in the two-level system, in comparison with toggle brace damper system in 2, 5, and 8-story building frames, in average, decrease by 15, 55, and 37% respectively. This amount in a 5-story building frame under the earthquakes with one-third scale decreases by 64%.
The purpose of this study was to investigate the acquisition of number-word systems of young children. Specifically, the acquisition of Korean Number-Words(KNW) was compared with the acquisition of Chinese-derived Number-Words(CNW). The subjects included 120 children aged 2:5 to 5:11. The subjects oral counting using the two number word systems were audiotaped. Two coders transcribed the tapes. The data were analyzed by content analysis with descriptive statistics. The findings of this study showed that the acquisition of KNW began from around age two and the acquisition of CNW from around age three. From then, the acquisition of the two number-word systems was parallel. The acquisition of number-words began from the age of 2 years, increased slowly to the age of 4. and then increased rapidly after the age of 5. Although KNW were acquired earlier than CNW, at around the age of 5 years the acquisition of CNW surpassed the acquisition of KNW. The acquisition of number words consists of four developmental levels: Level I: beginning of acquisition of traditional KNW only Level II: beginning of acquisition of CNW with extension of KNW Level III: parallel extension of the two number-word systems Level IV: superior acquisition of CNW. The major error through all stages in the sequence of number words was the omission of one number-word. Younger children produced errors of omission of one, two or three number-words, whereas older children produced errors of nonstandard number-words and repetition.
Kim, K.W.;Choe, K.O.;Park, C.Y.;Lee, H.;Son, H.Y.;Huh, K.B.;Ryu, K.J.
The Korean Journal of Nuclear Medicine
/
v.13
no.1_2
/
pp.37-43
/
1979
This is an analysis of 39 patients studied at the Yonsei Medical Center from January, 1976 to March 1979. Of these35 patient were suspected of having hypothalamic insufficiency and subjected to the L-Dopa stimulation test to observe growth hormone sceretory function while four acromegaly patient received the glucose loading test and L-Dopa stimulation test. The results are as follows: 1. The basal level of GH in the various disease was as follows: a. The basal level was lower than the control level but was not statistically significant b. In diabetes the mean value tended to be higher than the control level but was not significant statistically c. In all four acromegaly patients the GH level was significantly higher than the control level 2. Of 13 patients with diabetes, nine had diabetic retinopathy, and of those nine, sir showed increased L-Dopa response. However, of the four non retinopathic DM patients, only one showed increased response to L-Dopa. 3. Two patients out of ten with Sheehan's syndrome responded to L-Dopa stimulation. 4. One Patient of eight with pituitary chromophobe adenoma responded to L-Dopa stimulation. 5. Four acromegaly patients revealed 3 acidophilic adenoma and one chromophobe adenoma histologically. Of patients receiving the L-Dopa stimulation test. Two showed a paradoxical response. Two patients who received the glucose loading test showed supressed response. 6. Of two craniopharyngioma patients, one showed increased GH response after L-Dopa stimulation. Increased response of GH after L-Dopa stimulation was seen in one of two craniopharyngioma patients and also in one of two patients with
Proceedings of the Korean Nuclear Society Conference
/
1996.11a
/
pp.301-306
/
1996
To predict the average liquid level under the condition of the countercurrent stratified two-phase flow in a pipe, an analytical model has been suggested. This is made by introducing the interfacial level gradient into the liquid-phase and the gas-phase momentum equations. The analytical method for the gas-phase pressure drop calculation with f$_i$$\neq$ f$_G$ has also been described using the liquid level prediction model developed in the present study.
Objective : This study assessed the efficacy of anterior cervical discectomy and fusion (ACDF) with cage alone compared with ACDF with plate instrumentation for radiologic and clinical outcomes in two-level cervical degenerative disease. Methods : Patients with cervical degenerative disc disease from September 2004 to December 2009 were assessed retrospectively. A total of 42 patients received all ACDF at two-level cervical lesion. Twenty-two patients who underwent ACDF with cage alone were compared with 20 patients who underwent ACDF with plate fixation in consideration of radiologic and clinical outcomes. Clinical outcomes were assessed using Robinson's criteria and posterior neck pain, arm pain described by a 10 point-visual analog scale. Fusion rate, subsidence, kyphotic angle, instrument failure and the degenerative changes in adjacent segments were examined during each follow-up examination. Results : VAS was checked during each follow-up and Robinson's criteria were compared in both groups. Both groups showed no significant difference. Fusion rates were 90.9% (20/22) in ACDF with the cage alone group, 95% (19/20) in ACDF with the plate fixation group (p = 0.966). Subsidence rates of ACDF with cage alone were 31.81% (7/22) and ACDF with plate fixation were 30% (6/20) (p = 0.928). Local and regional kyphotic angle difference showed no significant difference. At the final follow-up, adjacent level disease developed in 4.54% (1/22) of ACDF with cage alone and 10% (2/20) of ACDF with plate fixation (p= 0.654). Conclusion : In two-level ACDF, ACDF with cage alone would be comparable with ACDF with plate fixation with regard to clinical outcome and radiologic result with no significant difference. We suggest that the routine use of plate and screw in 2-level surgery may not be beneficial.
Journal of Korean Society of Industrial and Systems Engineering
/
v.13
no.21
/
pp.101-110
/
1990
This study presents a two-level inventory distribution system with one-upper level facility(warehouse) in first echelon and n-lower level facilities(stores) in the second echelon. The demand process at the upper level is induced by the aggregated backorder processes of n independently operated lower level facilities in parallel. For the upper level and the lower level we find the decision points and the distribution function of the aggregate backorders from n-stores. Optimal allocation units and expected system profits are obtained. If the product is of great enough importance to the customer, echelon structure will include a shadow installation. Also, this case is analyzed. Numerical examples are presented to illustrate the results for each case.
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.7
no.1
/
pp.33-48
/
1997
Korean diffusive sampler (KDS) and charcoal tube (CT) were used for sampling n-hexane, trichloroethylene and toluene in air KDS was made by Department of Environmental Health, SNU-SPH in 1995. Surveys were conducted at ten industrial plants with organic solvents. The relationship between two sampling methods was examined by linear regression analysis, and concentrations by two sampling methods were compared using paired t-test. The results are as follows: 1. The geometric means by CT and KDS methods were 3.26ppm and 3.32ppm for n-hexane, 5.07ppm and 6.34ppm for toluene, and 7.18ppm and 7.90ppm for toluene, respectively. There was no significant difference between results by CT and KDS methods in three organic vapors (p>0.05). When linear regression analysis was performed, two sampling methods were highly related ; correlation coefficients were 0.98, 0.90 and 0.96 for n-hexane, toluene and trichloroethylene, respectively. 2. Airborne concentrations of n-hexane (n=21) were below 0.5 TLV level. The GM by two methods were almost same (3.09 ppm). And there was no significant difference between results by two methods (p>0.05). 3. Since toluene and trichloroethylene concentrations showed several levels, appropriate sampling rates were applied for each level. The GM of toluene concentrations by two methods at 0.5 TLV level were 3.75ppm and 5.48ppm. The KDS method overestimated the toluene concentrations at 0.5 TLV level (p<0.05). The GM values of toluene concentrations at 1 TLV level were 31.80ppm and 25.38ppm and at 2 TLV level were 64.13 ppm and 51.37 ppm. The KDS method underestimated concentration at both level (p<0.05). For trichloroethylene, the GM at 0.5 TLV level were 4.97 ppm and 7.11ppm. The KDS method overestimated the concentration of trichloroethylene (p<0.05). In conclusion, concentrations of three organic vapors measured by CT and KDS were not significantly different and results by two methods were highly related. But at contain concentrations, the levels by method were significantly different. Therefore, it is suggested that sampling rate of KDS should be studied simultaneously using CT method for organic vapors.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.