• Title/Summary/Keyword: turn fault

Search Result 129, Processing Time 0.026 seconds

Analysis of Transient Characteristics of SFCL using the Three-Phase Transformer and Power Switch (삼상 변압기와 전력용 스위치를 이용한 초전도 한류기의 과도특성 해석)

  • Jung, Byung-Ik;Choi, Hyo-Sang;Park, Jung-Il;Cho, Geum-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1743-1747
    • /
    • 2012
  • The research of superconducting fault current limiter (SFCL) for reduction of the fault current is actively underway in the worldwide. In this paper, we analyzed the characteristics of a SFCL using the transformer and superconducting elements combined mutually in accordance with the fault types. The structure of this SFCL was composed of the secondary and third windings of a transformer connected to the load and the superconducting element, respectively. The provided electric power flew into the load connected to the secondary winding of the transformer in normal state. On the other hand, when the fault occurred in power system, the fault current was limited by closing the line of third winding of the transformer. At this time, the effect of the fault was minimized by opening the fault line in secondary winding of a transformer in power system. The sensing of the fault state was performed by the current transformer(CT) and then turn-on and turn-off switching behavior of the secondary line in the transformer was performed by the silicon-controlled rectifier(SCR). As a result, the proposed SFCL limited the fault current within one-cycle efficiently. Also, the degradation of the superconducting element in the normal state was avoided.

A Daubechies Wavelet Transform Based Criterion Logic Scheme for Discrimination Between Inter-Turn Faults and Magnetizing Inrush in Transformer (도비시 웨이브렛 변환을 이용한 변압기의 여자돌입과 내부 권선고장 판별논리 기법)

  • Kwon, Myong-Hyun;Park, Chul-Won;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.5
    • /
    • pp.211-217
    • /
    • 2001
  • This paper proposes a new fault detection criterion logic that extracts the features of magnetizing inrush and internal faults by making use of Daubechies Wavelet Transform which analyzes distinct features. To prove the effectiveness of proposed method, the paper constructs power system model including power transformer by using EMTP, and collects data through simulation using various fault inception angle and magnetizing inrush. The conclusions implemented by the C program and the Wavemenu of MATLAB Toolbos are more effective and simpler to distinguish inter-turn faults from magnetizing inrush states.

  • PDF

Simplified d -q Equivalent Circuit of IPMSM Considering Inter-Turn Fault State (IPMSM의 선간단락고장에 따른 새로운 d -q 등가회로)

  • Kang, Bong-Gu;Hur, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1355-1361
    • /
    • 2016
  • The inter-turn fault (ITF) causes the negative sequence components in the d -q voltage equation due to an increase in the unbalance of three-phase input currents. For this reason, d -q voltage equation become complicate as the voltage equation is classified into positive and negative components. In this study, we propose a simplified d -q equivalent circuit of an interior permanent magnet synchronous motor under ITF state. First, we proposed modeling method for d -q current based on the finite element method simulation results. Then, we developed the simplified d -q equivalent circuit by applying the proposed d -q current modeling.

Automatic Diagnosis for Stator Winding Faults Using Distortion Ratio (왜곡률을 이용한 고정자 권선고장 자동진단)

  • Song, Myung-Hyun;Park, Kyu-Nam;Han, Dong-Gi;Yang, Chul-Oh
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.358-360
    • /
    • 2007
  • In this paper, an auto-diagnosis method of the stator winding fault for small induction motor is suggested. 3-phase stator currents are sampled, filtered, and transformed with Park's vector transformation. After then Park's vector patterns are obtained. To detect the stator winding fault automatically, a distortion ratio (id/iq) is newly defined and compared with the one of healthy motor, and the threshold levels are suggested. The 2-turn, 4-turn, 8-turn winding fault are tested with no load, 25%, 50%, 75%, and 100% rated load. The distortion ratio of the Park's vector patterns are increased as the increase of the faulted turns, but are same as the increase of the load.

  • PDF

Winding Fault Diagnosis for BLDC Motor using MCSA (MCSA를 이용한 BLDC 전동기의 고정자 권선 고장 진단)

  • Lee, Dae-Seong;Yang, Chul-Oh;Kim, Jun-Young;Kim, Dae-Hong;Moon, Yong-Seon;Park, Kyu-Nam;Song, Myung-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1876-1877
    • /
    • 2011
  • In this paper, a winding fault diagnosis method base on MCSA(Motor Current Signature Analysis) for BLDC motor is proposed. This method is programmed by LabVIEW for winding fault diagnosis. For winding fault diagnosis, two types of winding fault(shorted turn at one pole, shorted turn at two pole in same phase) are put intentionally in on phase. The motor current is collected by hole sensor, and transformed by the Park's transform, and then the Park's Vector Pattern are obtained, Usually this pattern is formed an ellipse, so a proper threshold value of distortion ratio(the ratio of the shortest axis and longest axis of ellipse) is suggested for winding faults diagnosis.

  • PDF

An Improved Gate Control Scheme for Overvoltage Clamping Under High Power IGBTs Switching (대용량 IGBT 스위칭 시 과전압 제한을 위한 향상된 게이트 구동기법)

  • 김완중;최창호;이요한;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.222-230
    • /
    • 1998
  • This paper proposes a new gate drive circuit for high power IGBTs which can reduce the harmful effect of reverse recovery current at turn-on and actively suppress the overvoltage across the driven IGBT at turn-off without a snubber circuit. The turn-on scheme decreases the rising rate of the collector current by inereasing the input capacitance at turn-on transient when the gate-emitter voltage goes above threshold voltage. It results in soft transient of the reverse recovery current with no variation in turn-on delay time. The turn-off driving scheme has adaptive feature to the amplitude of collector current, so that the overvoltage can be limited much effectively at the fault collector current. Experimental results under various normal and fault conditions prove the effectiveness of the proposed circuit.

  • PDF

Fault Detection and Diagnosis of Winding Short in BLDC Motors Based on Fuzzy Similarity

  • Bae, Hyeon;Kim, Sung-Shin;Vachtsevanos, George
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.9 no.2
    • /
    • pp.99-104
    • /
    • 2009
  • The turn-to-turn short is one major fault of the motor faults of BLDC motors and can appear frequently. When the fault happens, the motor can be operated without breakdown, but it is necessary to maintain the motor for continuous working. In past research, several methods have been applied to detect winding faults. The representative approaches have been focusing on current signals, which can give important information to extract features and to detect faults. In this study, current sensors were installed to measure signals for fault detection of BLDC motors. In this study, the Park's vector method was used to extract the features and to isolate the faults from the current measured by sensors. Because this method can consider the three-phase current values, it is useful to detect features from one-phase and three-phase faults. After extracting two-dimensional features, the final feature was generated by using the two-dimensional values using the distance equation. The values were used in fuzzy similarity to isolate the faults. Fuzzy similarity is an available tool to diagnose the fault without model generation and the fault was converted to the percentage value that can be considered as possibility of the fault.

The Analysis of Characteristics of Flux-Lock Type SFCL with Adjustable Inductance Level in Current Limiting Operation (인덕턴스 조정에 따른 자속구속형의 전류제한특성분석)

  • Lee, Na-Young;Choi, Hyo-Sang;Park, Hyoung-Min;Cho, Yong-Sun;Nam, Gueng-Hyun;Lim, Sung-Hun;Park, Chung-Ryul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.157-158
    • /
    • 2005
  • Superconducting fault currents(SFCLs) are expected to improve not only reliability but also stability of real power systems. The analysis on the single line-to-ground fault of the integrated three phase flux-lock type SFCL, which consists of three flux-lock reactor wound on an iron core in each single phase and three YBCO thin films, was investigated in current limiting operation characteristics. We compared 21turn numbers with 42turn numbers according to wound turn numbers each the coil 2 under the additive polarity winding operation between coil 1 and coil 2. The three phase flux-lock type SFCL using an iron core differently operates general three phase resistive SFCLs. When a single line-to-ground fault occurred, the SFCL's three units were quenched after fault onset. We confirmed effective current limiting operation characteristics with adjustable inductance level.

  • PDF

Stator Winding Fault Diagnosis in Small Three-Phase Induction Motors by Park's Vector Approach (Park's Vector 기법을 이용한 소형 3상 유도 전동기의 권선 고장 진단)

  • 박규남;한민관;우혁재;송명현
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.6
    • /
    • pp.1291-1296
    • /
    • 2003
  • This paper deals with efficient diagnostic for stator winding fault of 3-phase induction motor using a current Park's vector approach. This method firstly transforms 3-phase stator current to vertical axis current and horizontal axis current of Park's Vector, and then obtains the each Park's Vector Pattern and detects stator winding fault by comparing to Park's Vector Pattern of healthy and fault. Experimental results, obtained by using induction motor having inter-turn fault of 2, 10, 20 turn, demonstrate the effectiveness of the proposed technique, for detecting the presence of stator winding fault under 25%, 50%, and 100% of full load condition.

An Improved Gate Control Scheme for Overvoltage Clamping Under High Power IGBTs Switching (IGBT 스위칭시 괴전압 제한을 위한 게이트 구동기법)

  • 김완중;최창호;현동석
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.323-327
    • /
    • 1998
  • Under high power IGBTs Switching, a large overvoltage is induced across the IGBT module due to the stray inductance in the circuit. This paper proposes a new gate drive circuit for high power IGBTs which can actively suppress the overvoltage across the driven IGBT at turn-off while preserving the most simple and reliable power circuit. The turn-off driving scheme has adaptive feature to the amplitude of collector current, so that the overvoltage can be limited much effectively at the fault collector current. Experimental results under various normal and fault conditions prove the effectiveness of the proposed.

  • PDF