• Title/Summary/Keyword: turn

Search Result 6,931, Processing Time 0.03 seconds

Comparison of turn-on/turn-off transient in Electron Irradiated and Proton Irradiated Silicon pn diode (전자와 양성자를 조사한 PN 다이오드의 turn-on/turn-off transient 특성 비교)

  • Lee, Ho-Sung;Lee, Jun-Ho;Park, Jun;Jo, Jung-Yol
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1947-1949
    • /
    • 1999
  • Carrier lifetime in silicon power devices caused switching delay and excessive power loss at high frequency switching. We studied transient turn-on/turn-off transient characteristics of electron irradiated and proton irradiated silicon pn junction diodes. Both the electron and proton irradiation of power devices have already become a widely used practice to reduce minority carrier lifetime locally[1]. The sample is n+p junction diode, made by ion implantation on a $20\Omega.cm$ p-type wafer. We investigated turn-on/turn-off transient & breakdown voltage characteristics by digital oscilloscope. Our data show that proton irradiated samples show better performance than electron irradiated samples.

  • PDF

Design of Switched Reluctance Motor for Minimizing the Torque Ripple (스위치드 릴럭턴스 전동기의 토오크 리플 저감 설계)

  • Kim, Youn-Hyun;Choi, Jae-Hak;Kim, Sol;Lee, Ju;RhYu, Se-Hyun;Sung, Ha-Kyung;Im, Tae-Bin;Borm, Jin-hwan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.7
    • /
    • pp.339-350
    • /
    • 2002
  • Pole arcs, turn-on angle, and turn-off angle are major design factors, which affects Switched Reluctance Motor's torque performance. If these design factors are considered independently, the enhancement of SRM performance is restricted. Therefore, we need to consider pole arcs, turn-on angle and turn-off angle at the same time, when we design SR. In this paper, we analyze how these factors affect to torque ripple and average torque by using dynamic Finite Element Method(FEM) with derive circuit and present the good design results according to the various speeds. Especially, we formulate turn-on and turn-off angle from a voltage equation and present effective design range.

Development of Optimal Path Algorithm for Advanced Traveler Information System (첨단교통정보시스템의 최적경로 알고리즘 개발)

  • Kim, Sung-Soo;Cha, Young-Min
    • Journal of Industrial Technology
    • /
    • v.21 no.A
    • /
    • pp.241-249
    • /
    • 2001
  • The objective of this paper is to develop the optimal path algorithm for dynamic route guidance system in advanced traveler information system (ATIS). The travel time is forecasted in each path between network nodes. Floyd-Warshall algorithm is used to find the optimal route based on this forecasted travel time in dynamic traffic network. This algorithm is modified to apply the real traffic network that has left-turn restriction, U-turn, and P-turn. A big value is assigned to one of arcs in turn restriction and a virtual node is used to consider U-turn and P-turn for Floyd-Warshall algorithm.

  • PDF

Establishing Probability-Based Warrants for Right-Turn Lanes at Unsignalized Intersections (확률기반 비신호교차로의 우회전 전용차로 설치 기준 정립)

  • Moon, Jaepil
    • International Journal of Highway Engineering
    • /
    • v.19 no.6
    • /
    • pp.183-190
    • /
    • 2017
  • PURPOSES : The objective of this study is to establish the traffic volume-based warrants of right-turn lanes at unsignalized intersections and to introduce a risk probability methodology based on the warrants. METHODS : In this study, a risk probability of a potential rear-end collision is applied between a right-turn vehicle and the immediately following through vehicle. Using the shifted negative exponential model and the compound probability theorem, the risk probability can be expressed as the function of directional volumes and the percentage of right-turns for a two-lane and four-lane highway, respectively. RESULTS : Based on the risk probablity, guidelines for installing right-turn lanes on two-lane and four-lane highways were developed. The risk probability also showed rationality by comparing with right-turn same-direction conflicts observed in-situ. CONCLUSIONS : The results of our study define the total approaching volumes to encourage a right-turn lane as a function of operating speed, percentage of right-turn, and number of lanes.

A Study on Installation of U-Turn Lane for Efficient Operation of Left Turn at Signalized Intersections (신호교차로 좌회전 효율적 처리를 위한 유턴차로 설치방법 연구)

  • Park, Chahgwha;Yoon, Byoungjo;Kang, Bongsuk
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.4
    • /
    • pp.597-606
    • /
    • 2015
  • Until now, u-turn lane installation methods have been studied variously. But, There is no specific standard yet. This study ranges are commercial area in Incheon metropolitan city through field investigation and presents specific design standard for efficient operation of left turn using a field data through calculating relevant permitted u-turn lane length and minimum separation distance from the front intersection to starting point of permitted u-turn lane in urban signalized intersections in commercial area. Relevant permitted u-turn lane length is found to be 32m and minimum separation distances from the front intersection to starting point of permitted u-turn lanes are 72m, 40m, 24m in case of 1 left turn lane, 2 left turn lanes and 3 left turn lanes respectively. By comparing result values and field data, they had a large difference under the similar situations in their lengths. This result is caused of no specific standard about design of u-turn lanes. If results of this study applied to design of u-turn lanes, signalized intersections in urban commercial areas would be operated more safety and efficiently.

Kinematic Comparative Analysis of Long Turns between Experienced and Inexperienced Ski Instructors

  • Jo, Hyun Dai
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.1
    • /
    • pp.17-25
    • /
    • 2020
  • Objective: The purpose of this study is to provide a better understanding of long turn mechanism by describing long turns after kinematic analysis and provide skiers and winter sports instructors with data through which they are able to analyze right postures for turns in skiing in a systematic, rational and scientific manner. Method: For this, a mean difference of kinematic variables (the center of gravity (CG) displacement of distance, trajectory, velocity, angle) was verified against a total of 12 skiers (skilled and unskilled, 6 persons each), regarding motions from the up-start to down-end points for long turns. Results: First, concerning the horizontal displacement of CG during a turn in skiing, skilled skiers were positioned on the right side at the upstart and edge-change points at a long turn. There was no difference in anteroposterior and vertical displacements. Second, in terms of CG-trajectory differences, skilled skiers revealed a significant difference during a long turn. Third, regarding skiing velocity, skilled skiers were fast at the edge-change and maximum inclination points in long turns. Fourth, there was no difference in a hip joint in terms of a lower limb joint angle. In a knee joint, a large angle was found at the up-start point among skilled skiers when they made a long turn. Conclusion: In overall, when skilled and unskilled skiers were compared, to make a good turn, it is required to turn according to the radius of turn by reducing weight, concerning the CG displacement. Regarding the CG-trajectory differences, the edge angle should be adjusted via proper inclination angulation. In addition, a skier should be more leaned toward the inside of a turn when they make a long turn. In terms of skiing velocity, it is needed to reduce friction on snow through the edging and pivoting of the radius or turn according to curvature and controlling ski pressure. Regarding a lower limb joint angle, it is important to make an up move by increasing ankle and knee angles instead of keeping the upper body straight during an up motion.

Dielectric Characteristics of Turn-ro-Turn Insulation for SFCL (초전도 한류기의 턴간 절연특성)

  • Baek, Seung-Myeong;Joung, Jong-Man;Lee, Chang-Hwa;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.65-68
    • /
    • 2003
  • Interconnected power system operation has given rise to the problem of increased fault levels and leads to over stressing of all the components. Use have been made of recently developed high Tc superconductor in devising a superconducting fault current limiter (SFCL) that promises optimum performance in terms of capital cost, size, auto sensing, operational losses, response time and reliability. Recently, research about the application of the SFCL is actively progressing in Korea. To be applied for SFCL practically, the electrical insulation design of SFCL must be developed. Therefore, this paper presents the result of an investigation of the dielectric characteristics of turn-to-turn insulation for SFCL in liquid nitrogen. The dielectric characteristics of turn-to-turn insulation models of SFCL were investigated. We obtained following results. The breakdown voltages increased as the spacer thickness and length increased. And the breakdown voltages of turn-to-turn model without spacer were higher than the breakdown voltages of turn-to-turn model with spacer under impulse as well as AC voltages. The information gathered in this test series should be helpful in the design of liquid nitrogen filled SFCL.

  • PDF

Development of the U-turn Accident Model at 4-Legged Signalized Intersections in Urban Areas (도시부 4지 신호교차로 유턴 사고모형 개발)

  • Kang, JongHo;Kim, KyungWhan;Ha, ManBok;Kim, SeongMun
    • International Journal of Highway Engineering
    • /
    • v.16 no.2
    • /
    • pp.119-129
    • /
    • 2014
  • PURPOSES : The purpose of this study is to develop the U-turn accident model at 4-legged signalized intersections in urban areas. METHODS : In order to analyze the characteristics of the accidents which are associated with U-turn operation at 4-legged signalized intersections in urban areas and develop an U-turn accident model by regression analysis, the tests of overdispersion and zero-inflation are conducted about the dependent variables of number of accidents and EPDO (Equivalent Property Damage Only). RESULTS : As their results, the Poisson model fits best for number of accident and the ZIP (Zero Inflated Poisson) fits best for EPOD, the variables of conflict traffic, width of opposing road, traffic passing speed are adopted as independent variable for both models. The variables of number of bus berths and rate of U-turn signal time at which the U-turn is permitted are adopted as independent variable only for EPDO. CONCLUSIONS : These study results suggest that U-turn would be permitted at the intersection where the width of opposing road is wider than 11.9 meters, the passing vehicle speed is not high and U-turn operation is not hindered by the buses stopping at bus stops.

Estimation of the Through Car Equivalent for Left-Turn Movement According to the Left-Turn Curve Radius in the Signalized Intersection (신호교차로에서 곡선반경에 따른 좌회전의 직진환산계수 산정)

  • 오영태;김기형
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.2
    • /
    • pp.21-28
    • /
    • 2001
  • This study is to estimate the through car equivalent for left-turn movement according to left turn radius in the signalized intersection. The saturation flow rate for left-turn movement in 92' KHCM(Korea Highway Capacity Manual) is the same as that for through movement in the signalized intersection where the left turn radius is over 20m. This study uses Duncan 'Test's Test in order to find out the saturated position for queued vehicle in the signalized intersection. It found that the saturated flow rate of left-turn movement in the signalized intersection is less than that of through movement where the left-turn radius is less than 20m. It found that the through car equivalents for left-turn movement according to left-turn radius(8m-20m) are between 1.05 and 1.14.

  • PDF

The Dielectric Characteristics of Turn-to-Turn Insulation for DC Reactor Type HTSFCL (DC reactor type 고온호전도 한류기의 턴간 절연 특성)

  • 백승명;정종만;이창화;류엔반둥;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1299-1304
    • /
    • 2003
  • Fault current limiters (FCL) are extensively needed to suppress fault currents, especially for trunk power systems heavily connected to high voltage/large current transmission lines. Due to its ideal electrical behavior, high-temperature superconductor fault current limiter (HTSFCL) becomes one of the most important developing trends of limiters in power system. This paper describes the result of an investigation of the dielectric characteristics of turn-to-turn insulation for pancake and solenoid type reactor coil in liquid nitrogen. The influence of thickness in a variety length, on AC, DC and impulse surface flashover has been investigated. Also, the relationships between the number of turn and breakdown characteristics were clarified. The information gathered in this test series should be helpful in the design of liquid nitrogen filled DC reactor type HTSFCL.