• Title/Summary/Keyword: turbo

Search Result 1,456, Processing Time 0.031 seconds

Design and Fabrication of Sputter Coating System for Ophthalmic Lens (안경렌즈코팅용 소형 Sputter Coating System 설계 및 제작에 관한 연구)

  • Park, Moonchan;Jung, Boo Young;Kim, Eung Sun;Lee, Jong Geun;Joo, Kyung Bok;Moon, Hee Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.53-58
    • /
    • 2008
  • Purpose: To design and fabricate the small sputter coating system for the Ophthalmic lens. Methods: The design of sputter target was done using macleod program for AR coating and mirror coating of Ophthalmic lens with Si target and then the sputter system was fabricated. Results: The optimum condition of AR coating with Si target was [air|$SiO_2$(81.3)|$Si_3N_4$ (102)|$SiO_2$(19.21)|$Si_3N_4$(15.95)|$SiO_2$(102)|glass], for blue color mirror coating [air|$SiO_2$(56.61)|$Si_3N_4$(135.86)|$SiO_2$(67.64)|$Si_3N_4$(55.4)|$SiO_2$(53.53)|$Si_3N_4$(51.28)|glass], for green color coating [air|$SiO_2$(66.2)|$Si_3N_4$(22.76)|$SiO_2$(56.58)|$Si_3N_4$(140.35)|$SiO_2$(152.35)|$Si_3N_4$(70.16)|$SiO_2$(121.87)|glass], for gold color [air|$SiO_2$(83.59)|$Si_3N_4$(144.86)|$SiO_2$(11.82)|$Si_3N_4$(129.93)|$SiO_2$(90.01)|$Si_3N_4$(88.37)|glass]. Conclusions: In the fabrication of sputtering coating apparatus, Dual cathode with same Ti target were coated at the same time on both sides of Ophthalmic lens to lessen the time of coating on Ophthalmic Lens and save the cost of the lens. The distance of target-substrate of cathode was variable from 12.5 cm to 20 cm. Turbo pump was used to take the whole coating process about 15 min. instead of diffusion pump. The lens holder was made to coat 2 pairs lens every coating and was rotated to get the uniformity of thin film.

  • PDF

Nutrients and Decomposition Rate Accumulated on Soil Layers in Quercus mongolica Forest of Mt. Songnisan National Park (속리산 신갈나무림의 토양층별 영양염류 함량과 분해율)

  • 강상준;한동열
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.1
    • /
    • pp.93-100
    • /
    • 2004
  • The content of nutrients such as organic carbon, nitrogen, phosphorus and potassium accumulated on soil layers in Quercus mongolica forest of Mt. Songnisan National Park located at central part of Korea was measured, and then the decomposition constants and decay times of the nutrients were also calculated by the negative coefficience model(O1son,1963). The quantities of organic carton of L-layer, F-layer, H-layer and $A_1$-layer of the forest stand were 231.25 g $m^{-2}$, 291.50 g $m^{-2}$,166.91 g$m^{-2}$ and 174.51 g $m^{-2}$, respectively. The content of organic carbon and nitrogen contained in L-layer and F-layer showed large quantity than those of other layers. The large amount of phosphorus and potassium was observed at the B-layer and $A_1$-layer. On the other hand, the decomposition constants(k) of soil organic matter were as follows : organic carbon (k = 0.3657), nitrogen (k = 0.3319), phosphorus (k = 0.2050), and potassium (k = 0.0934) and the decay times needed to 99% decomposition of nutrients in soil organic matter were as follows: that is, organic carton, nitrogen, phosphorus and potassium was 13.94 years, 15.18 years, 24.79 years, and 55.11 years, respectively. By the application of Turbo Pascal Program on the inflowed and outflowed nutrients to the forest stand,87.67% (714.84 g $m^{-2}$) of organic carbon inflowed was decomposed and 81.62% (1,594.62 g $m^{-2}$) of organic carbon accumulated was decomposed. And 84.98% of nitrogen inflowed was decomposed and 70.26% of nitrogen accumulated was also decayed.50.00% of phosphorus input and 40.31% of potassium input were decomposed, and 38.40% of phosphoyus and 33.03% of potassium accumulated were also decayed, respectively. Therefore, it is suggested that Quercus mongolica forest surveyed in the present study is maintaining in steady state because input and output amounts of nutrients is shown a similar pattern.

A Study for the Methodology of Analyzing the Operation Behavior of Thermal Energy Grids with Connecting Operation (열 에너지 그리드 연계운전의 운전 거동 특성 분석을 위한 방법론에 관한 연구)

  • Im, Yong Hoon;Lee, Jae Yong;Chung, Mo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.3
    • /
    • pp.143-150
    • /
    • 2012
  • A simulation methodology and corresponding program based on it is to be discussed for analyzing the effects of the networking operation of existing DHC system in connection with CHP system on-site. The practical simulation for arbitrary areas with various building compositions is carried out for the analysis of operational features in both systems, and the various aspects of thermal energy grids with connecting operation are highlighted through the detailed assessment of predicted results. The intrinsic operational features of CHP prime movers, gas engine, gas turbine etc., are effectively implemented by realizing the performance data, i.e. actual operation efficiency in the full and part loads range. For the sake of simplicity, a simple mathematical correlation model is proposed for simulating various aspects of change effectively on the existing DHC system side due to the connecting operation, instead of performing cycle simulations separately. The empirical correlations are developed using the hourly based annual operation data for a branch of the Korean District Heating Corporation (KDHC) and are implicit in relation between main operation parameters such as fuel consumption by use, heat and power production. In the simulation, a variety of system configurations are able to be considered according to any combination of the probable CHP prime-movers, absorption or turbo type cooling chillers of every kind and capacity. From the analysis of the thermal network operation simulations, it is found that the newly proposed methodology of mathematical correlation for modelling of the existing DHC system functions effectively in reflecting the operational variations due to thermal energy grids with connecting operation. The effects of intrinsic features of CHP prime-movers, e.g. the different ratio of heat and power production, various combinations of different types of chillers (i.e. absorption and turbo types) on the overall system operation are discussed in detail with the consideration of operation schemes and corresponding simulation algorithms.

Studies on the Nucleotide composition of ribonucleic acid in the mid-intestinal gland (liver) of marine shell-fishes (해산패류(海産貝類)(6종(種))의 중장선(中腸腺)(간(肝)) RNA의 nucleotide 조성(組成)에 관(關)한 연구(硏究))

  • Kim, Hyeong-Su
    • Applied Biological Chemistry
    • /
    • v.5
    • /
    • pp.23-31
    • /
    • 1964
  • Six species of marine shell-fishes were subjects in this study. The content of RNA and DNA in mid-intestinal glands (liver) was determined and RNA was also extracted from above materials by phenol method and their nucleotide compositions were analysed by ion exchange column chromatography. C; citidylic acid, A; adenylic acid, G; guanylic acid, U; uridylic acid, Pu; purine nucleotide, Py; pyrimidine nucleotide 1) Their RNA and DNA content was summarized in the next table.(mg/100mg of lipid free powder) Materials RNA DNA RNA/DNA Meretrix meretrix Susoria (Gmelin) 6.82 0.82 6.5 Anadara(scapharea) inflata(Reeve) 4.62 0.70 6.6 Ostrea(crassostrea) gigas Thunberg 8.74 1.03 8.5 Turbo cornutus Solander 2.16 0.60 3.6 Haliotis gigantea Gmelin 7.02 0.22 36.0 2) Their RNA nucleatide compositions was summaries in following tabe. Materials/RNA nucleotide G+C/A+U G+U/A+C Pu/Py Meretrix meretrix Susoria(Gmelin) 1.12 1.36 1.08 Venerupis philippinarum (Adoms et Reeve) 1.15 1.31 1.13 Anadara(scapharea) inflata(Reeve) 0.97 1.26 1.02 Ostrea (crassostrea) gigas Thunberg 1.51 1.34 1.31 Turbo cornutus Solander 1.37 1.29 1.03 Haliotis gigantea Gmelin 1.33 1.46 1.22 In six species of marine fishes examined, Pu/Py and G+C/A+U ratios of RNA vary in respective wide ranges of 1.02-1.31, 0.97-1.51, while G+U/A+C ratio in the range of 1.26-1.46, not far from 1.3. This G+U/A+C ratio seems to be specific in this species.

  • PDF

Usefulness of Acoustic Noise Reduction in Brain MRI Using Quiet-T2 (뇌 자기공명영상에서 Quiet-T2 기법을 이용한 소음감소의 유용성)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.51-57
    • /
    • 2016
  • Acoustic noise during magnetic resonance imaging (MRI) is the main source for patient discomfort. we report our preliminary experience with this technique in neuroimaging with regard to subjective and objective noise levels and image quality. 60 patients(29 males, 31 females, average age of 60.1) underwent routine brain MRI with 3.0 Tesla (MAGNETOM Tim Trio; Siemens, Germany) system and 12-channel head coil. Q-$T_2$ and $T_2$ sequence were performed. Measurement of sound pressure levels (SPL) and heart rate on Q-$T_2$ and $T_2$ was performed respectively. Quantitative analysis was carried out by measuring the SNR, CNR, and SIR values of Q-$T_2$, $T_2$ and a statistical analysis was performed using independent sample T-test. Qualitative analysis was evaluated by the eyes for the overall quality image of Q-$T_2$ and $T_2$. A 5-point evaluation scale was used, including excellent(5), good(4), fair(3), poor(2), and unacceptable(1). The average noise and peak noise decreased by $15dB_A$ and $10dB_A$ on $T_2$ and Q-$T_2$ test. Also, the average value of heartbeat rate was lower in Q-$T_2$ for 120 seconds in each test, but there was no statistical significance. The quantitative analysis showed that there was no significant difference between CNR and SIR, and there was a significant difference (p<0.05) as SNR had a lower average value on Q-$T_2$. According to the qualitative analysis, the overall quality image of 59 case $T_2$ and Q-$T_2$ was evaluated as excellent at 5 points, and 1 case was evaluated as good at 4 points due to a motion artifact. Q-$T_2$ is a promising technique for acoustic noise reduction and improved patient comfort.

Cooling Effect of Air in Greenhouse Using A Fog Sprayer Consisted of Two-fluid Nozzle with Turbo Fan (터보 팬 2류체 노즐로 구성한 포그 분무장치를 이용한 온실 내 공기의 냉각 효과)

  • Kim, Tae-Kyu;Min, Young-Bong;Kim, Do-Wan;Kim, Myung-Kyu;Moon, Sung-Dong;Chung, Tae-Sang
    • Journal of agriculture & life science
    • /
    • v.46 no.3
    • /
    • pp.119-127
    • /
    • 2012
  • For the promotion of the evaporative cooling efficiency of hot air in greenhouse in summer, a fog sprayer consisted of a high volume spraying two-fluid nozzle with turbo fan and a blowing fan was set up at 2.2 m height from bottom of small glass greenhouse and tested to estimate the possibility of the greenhouse cooling. The mean droplet size and the volume sprayed by one of fog sprayer were $29{\mu}m$ and $160m{\ell}/min$. All the droplets sprayed and blown by the fog sprayer were evaporated within 2 m radius. The result from the cooling test that two sprayers set up in glass greenhouse of plane area $228m^2$ was represented lower cooling effect that the temperature and relative humidity of inside air of greenhouse were $28.8^{\circ}C$ and 87.5% when those of outside air of greenhouse were $30.2^{\circ}C$ and 81.2%. Through investigation of literatures and results of the cooling test, it was estimated that the water spraying rate of evaporative cooling of single span greenhouse with 50% light curtain and with air change rate of 1 volume/min was $10m{\ell}/min/m^2$ so that the inside air temperature may cool down $2{\sim}3^{\circ}C$ on the basis of $35^{\circ}C$ atmospheric temperature in summer of south korean area.

Optimization of the Community Energy Supply System for D-Cube City, Multi Purpose Building (복합건물(D-Cube City) 지역에너지 공급체계 최적화)

  • Lee, Tae-Won;Kim, Yong-Ki;Lee, Kun-Woo;Lee, Ki-Bong;Cho, Dong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.669-674
    • /
    • 2012
  • D-Cube City is a recently completed multi purpose building consisting of four types of facilities; offices, a department store, a hotel, and congregation spaces. A community energy supply system(CES) has been installed to supply this building with electricity, steam, heat, and cold water. The BEMS, building energy management system, is currently being designed to reduce building energy consumption through the efficient operation of the various pieces of building service equipment. In this study the optimal methods for operating the CES of D-Cube City were considered. This system includes three combined heat and power systems, seven steam boilers, two hot water boilers, two absorption chillers, and four turbo chillers, and various other pieces of equipment. In result, the optimal methods of operating the CES for various energy demand levels were obtained along with the seasonal effects on the economic efficiency of the operation. The effect of the amount of energy demanded by the various facility areas on the total energy consumption was also analyzed.

Factors Influencing Frequency of Abnormal Peak in the Measurement of HbA1c by HPLC (HPLC법을 이용한 HbA1c 측정시 Abnormal Peak의 빈도와 원인)

  • Kim, Sun-Kyung;Bae, Ae-Young;Choi, Dae-Yong;Kim, Myung-Soo;Yoo, Kwang-Hyun;Ki, Chang-Seok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.2
    • /
    • pp.71-77
    • /
    • 2005
  • We experienced the specimen that contains a hemoglobin variant known as interference from HbAS in October 2003. It was the first case of Hb variants since Samsung Medical Center began conducting glycohemoglobin College of American Pathologists surveys in 1997. The purpose of this study is to share our experience with the specimen and promote the understanding of Hb variants & derivatives. We've performed cross checks to examine HbA1c by using two pieces of equipment; the TOSHOH G7 and BIO-RAD VARIANT-T(turbo), and Automatic High Performance Liquid Chromatography(HPLC) as an analytic measurement method. HPLC provides different fractional information of hemoglobin with a two-dimensional graph as well as numeric results. We have been performing a "Systematic Checking Process". Three specimen suspicious of Hb variants & derivatives were found through this process. College of American Pathologists notified that it is important for users to be aware of the limitation of their glycohemoglobin method to avoid reporting incorrect results due to interference from hemoglobin variants or hemoglobin adducts. Therefore, laboratory findings of Hb variants & derivatives are very important. The experience of qualified technicians with professional knowledge in Hb variants is the most important aspect in finding Hb variants. Korea is homogeneous in race and is not in an area with a higher finding rate of Hb variants. While 1,024 cases of Hb variants have been found in Japan, we do not have specific data on how many cases of Hb variants have been found in Korea. Considering Hb variant cases in Japan, which is geographically close to us, it is presumed that there must be various Hb variant cases in Korea. If domestic laboratories set a systemic protocol and build a network to share our experience in Hb variants, I expect the Korean Hb variants could also be listed on the world's Hb variant list.

  • PDF

Evaluation of Articular Cartilage using 3D FFE-PROSET Technique in 3.0 T Knee MR Imaging : Comparison with 2D TSE - SPIR Technique (3.0T 무릎자기공명영상에서 3차원 FFE-PROSET 기법을 이용한 관절연골평가 : 2차원 TSE-SPIR 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.599-606
    • /
    • 2013
  • The purpose of this study is to know a clinical usefulness for delineation of articular cartilage compared with 2D TSE-SPIR and 3D FFE-PROSET technique. From January 2013 to september 2013, a total of 30 normal volunteers(12 men and 18 women aged between 35 and 55 years; mean 49.48 years) were studied on a philips 3.0T MRI scanner. As a quantitative analysis, SNRs and CNRs were evaluated by using two methods for delineation of articular cartilage. As a qualitative analysis, image quality was evaluated by special radiological technologist of MRI for image delineation on a three grade. As a results, SNRs and CNRs for articular cartilage were significantly greater for the 3D FFE-PROSET(SNRs: 8.40, 114.02, 9.53, CNRs: 104.49, 139.49) technique compared to 2D TSE-SPIR(SNRs: 4.41, 71.63, 7.34, CNRs: 64.30, 58.41) technique, image quality also was higher for evaluation of 3D FFE-PROSET(2.40) technique(p=0.0021). In conclusion, this study showed that a 3D FFE-PROSET MRI has improved SNRs and CNRs for evaluating of the articular cartilage, these conclusions in the future will be provided useful information in diagnosis of articular cartilage.

양산에 적합한 구조의 X-ray 검출기 공정에 대한 연구

  • Gwon, Jun-Hwan;O, Gyeong-Min;Song, Yong-Geun;Kim, Ji-Na;No, Seong-Jin;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.265-266
    • /
    • 2012
  • 의료용 X-ray의 발전에 따라, 영상의 Digital화가 필요하게 되었다. Digital 영상 구현을 위해 다양한 형태의 영상 검출기가 개발되었다. 진단 영상의 조건으로는 구현 시간이 빠르고 해상도가 높아야 한다. 조건에 부합하는 Flat panel 형태의 직접방식과 간접방식 검출기의 개발이 주로 이루어졌으며, X-ray 검출 효율이 높고 공간 분해능이 높은 직접 방식의 검출기에 대한 연구가 활발히 진행되고 있다. 기존 직접방식의 X-ray 검출물질로는 A-Se이 이용되었다. 하지만 A-Se의 경우 낮은 원자번호로 인해 X-ray에 대한효율이 낮으며, 제조 공정과 수율의 문제로 인해 대체 물질의 개발과 공정의 개선이 필요하다. 선행 연구를 통해 X-ray 검출물질의 전기적 특성을 파악을 통해 대체 물질로서 가능성을 알아보았다. 본 연구에서는 기존에 제작된 X-ray 검출물질의 상부전극 증착 물질과 증착법 선정에 대한 연구이다. 선행 연구를 통해 선정된 X-ray 검출물질은 HgI2이다. 상, 하부 전극 선택에 있어 HgI2의 일함수 값(4.15eV)을 고려하여 그와 비슷한 일함수 값을 가진 물질로 전기적 장벽을 제거하여야 한다. 따라서, ITO (일함수 4.45eV)와 Au (일함수 5.1eV)을 선택하였다. ITO의 증착으로 이용된 방법으로는 on-axis 형태의 magnetron plasma sputtering을 이용하였으며, Au의 증착으로 이용된 방법은 Thermal evaporation deposition을 이용하였다. plasma sputtering에 이용된 타겟은 In2O3;SnO2 (조성비:90:10wt%)를 사용하였으며, Chamber의 크기는 넓이 456 ${\phi}cm^2$ 높이 25 cm이며, 로 target과 기판과의 거리는 15cm이다. plasma발생에 필요한 가스로는 Ar과 O2를 이용하였다. 고 진공 환경 조성에 이용된 장비로는 Rotary pump와 Turbo molecular pump이다. plasma 발생 전 진공도는 $3.2{\times}10^{-5}$ Torr, 발생 후 진공도는 $5.1{\times}10^{-5}$ Torr이다. plasma 환경이 조성된 후 증착 시간은 1분 30초이다. Au는 순도 99.999%를 이용하였으며, 이용된 금은 1회 증착에 0.3 g을 이용하였다. Chamber의 넓이 1,444 ${\phi}cm^2$이며, 높이 40 cm, boat와 기판과의 거리는 25 cm이다. 고 진공 환경 조성에 이용된 장비로는 Rotary pump와 diffusion pump를 이용하였다. Au의 승화 전 진공도는 $2.4{\times}10^{-5}$ Torr 증착 시 진공도는 $4.2{\times}10^{-5}$ Torr이며, Boat에 가해준 전압, 전류는 0.97 V, 47 A이며, 증착 시간은 1분 30초이다. 광도전체 층에 각각 증착된 전극의 저항을 통해 증착상태를 판단하였다. DMM (Digital Multimeter)로 1 cm 간격으로 측정된 표면의 저항은 ITO 약 $8{\Omega}$, Au 약 $3{\Omega}$으로 전극으로서 이용이 가능한 상태이다. Au와 ITO가 증착된 HgI2 시편의 전기적 특성은 기존에 이용된 X-ray 변환물질의 성능보다 우수하였다. 하지만 Au와 ITO가 각각 증착된 시편의 전기적 특성은 큰 차이를 보이지 않았다. ITO의 경우 진공 상태에서 이용되는 Gas가 이용되며, Plasma 환경 조성 유지가 어려운 점이 있다. Au전극은 증착 환경 조성이 쉽지만, 전극 물질 이용효율이 떨어지는 단점이 있다. 본 연구를 통해 X-ray 변환물질인 HgI2의 전극물질로 Au와 ITO의 이용가능성을 알아보았다. 두 전극으로 제작된 검출기의 성능은 큰 차이 없이 우수하였고, 전기적 장벽 상태가 낮아 높은 검출 효율을 보였다. 상대적으로 Au 전극의 공정이 간단하고 수율이 높다. 하지만 Au Source의 이용 효율이 떨어지는 단점이 있다. 본 연구의 결과를 통해 공정상의 유리함과 Source의 이용효율을 고려한 분석에 대한 연구가 필요할 것으로 사료된다.

  • PDF