• 제목/요약/키워드: turbine operating mode

검색결과 61건 처리시간 0.027초

Control and Operation of Hybrid Microsource System Using Advanced Fuzzy- Robust Controller

  • Hong, Won-Pyo;Ko, Hee-Sang
    • 조명전기설비학회논문지
    • /
    • 제23권7호
    • /
    • pp.29-40
    • /
    • 2009
  • This paper proposes a modeling and controller design approach for a hybrid wind power generation system that considers a fixed wind-turbine and a dump load. Since operating conditions are kept changing, it is challenge to design a control for reliable operation of the overall system To consider variable operating conditions, Takagi-Sugeno (TS) fuzzy model is taken into account to represent time-varying system by expressing the local dynamics of a nonlinear system through sub-systems, partitioned by linguistic rules. Also, each fuzzy model has uncertainty. Thus, in this paper, a modem nonlinear control design technique, the sliding mode nonlinear control design, is utilized for robust control mechanism In the simulation study, the proposed controller is compared with a proportional-integral (PI) controller. Simulation results show that the proposed controller is more effective against disturbances caused by wind speed and load variation than the PI controller, and thus it contributes to a better quality wind-hybrid power generation system.

복합열병합 시스템에 대한 열과 전기의 원가산정 (Cost Accounting of Heat and Electricity of a Combined Cycle Cogeneration System)

  • 김덕진;이근휘
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.560-568
    • /
    • 2005
  • The cost accounting of electricity and heat produced from an energy system is important in evaluating the economical efficiency and deciding the reasonable sale price. The OECOPC method, suggested by the author, was applied to a 650 MW combined cycle cogeneration system having 4 operating modes, and each unit cost of electricity and heat products was calculated. In case that a fuel cost is ${\\}400/kg$ and there are no direct and indirect cost, they were calculated as follows; electricity cost of ${\\}23,700/GJ$ at gas-turbine mode, electricity cost of ${\\}15,890/GJ$ at combined cycle mode, electricity cost of ${\\}14,146/GJ$ and heat cost of ${\\}6,466/GJ$ at cogeneration mode, and electricity cost of ${\\}14,387/GJ$ and heat cost of ${\\}4,421/GJ$ at combined cycle cogeneration mode. Further, these unit costs are applied to account benefit on this system. Since the suggested OECOPC method can be applied to any energy system, it is expected to contribute to cost accounting of various energy systems.

Effect of control route on the unstart/restart characteristics of an over-under TBCC inlet

  • Li, Nan;Chang, Juntao;Tang, Jingfeng;Yu, Daren;Bao, Wen;Song, Yanping
    • Advances in aircraft and spacecraft science
    • /
    • 제5권4호
    • /
    • pp.431-444
    • /
    • 2018
  • Numerical simulations have been conducted to study the unstart/restart characteristics of an over-under turbine-based combined-cycle propulsion system (TBCC) inlet during the inlet transition phase. A dual-solution area exists according to the Kantrowitz theory, in which the inlet states may be different even with the same input parameters. The entire transition process was divided into five stages and the unstart/restart hysteresis loop for each stage was also obtained. These loops construct a hysteresis surface which separates the operating space of the engine into three parts: in which a) inlet can maintain a started state; b) inlet keeps an unstarted state; c) inlet state depends on its initial state. During the transition, the operation of the engine follows a certain order with different backpressures and splitter angles, namely control route, which may result in disparate inlet states. Nine control routes with different backpressures and transition stages were designed to illuminate the route-dependent behavior of the inlet. The control routes operating towards the unstart boundary can make the inlet transit from a started state into an unstarted one. But operating backward the same route cannot make the inlet restart, additional effort should be made.

상용 S/W를 이용한 소형가스터빈엔진 회전체의 동적 구조해석 및 검증 (Dynamic Analysis of the Small-size Gas Turbine Engine Rotor Using Commercial S/W and its Limitations)

  • 정혁진;이종원;홍성욱;유태규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.797-803
    • /
    • 2009
  • The accurate prediction of dynamic characteristics of high speed rotors, such as gas turbines, is important to avoid the possibility of operating the machinery near the critical speeds or unstable speed regions. However, the dynamic analysis methods and softwares for gas turbines have been developed in the process of producing many gas turbines by manufacturers and most of them have seldom been disclosed to the public. Recently, commercial FEM softwares, such as SAMCEF, ANSYS and NASTRAN, started supporting some rotordynamics analysis modules based on 3-D finite elements. In this paper, the dynamic analysis method using commercial S/W, especially ANSYS, is attempted for the small-size gas turbine engine rotor, and the analysis capability and limitations of its rotordyamics module are evaluated for further improvement of the module. As the preliminary procedure, the rotordyamic analysis capability of ANSYS was tested and evaluated with the reference models of the well-known dynamics. The limitations in application of the rotordynamics module were then identified. Under the current capability and limitations of ANSYS, it is shown that Lee diagram, a new frequency-speed diagram enhanced with the concept of $H{\infty}$ in rotating machinery, can be indirectly obtained from FRFs computed from harmonic response analysis of ANSYS. Finally, it is demonstrated based on the modeling and analysis method developed in the process of the S/W verification that the conventional Campbell diagram, Lee diagram, mode shapes and critical speeds of the small-size gas turbine engine rotor can be computed using the ANSYS rotordynamics module.

  • PDF

상용 S/W를 이용한 소형가스터빈엔진 회전체의 동적 구조해석 및 검증 (Dynamic Analysis of the Small-size Gas Turbine Engine Rotor Using Commercial S/W and Its Limitations)

  • 정혁진;이종원;홍성욱;유태규
    • 한국소음진동공학회논문집
    • /
    • 제20권1호
    • /
    • pp.36-44
    • /
    • 2010
  • The accurate prediction of dynamic characteristics of high speed rotors, such as gas turbines, is important to avoid the possibility of operating the machinery near the critical speeds or unstable speed regions. However, the dynamic analysis methods and softwares for gas turbines have been developed in the process of producing many gas turbines by manufacturers and most of them have seldom been disclosed to the public. Recently, commercial FEM softwares, such as SAMCEF, ANSYS and NASTRAN, started supporting some rotordynamics analysis modules based on 3-D finite elements. In this paper, the dynamic analysis method using commercial S/W, especially ANSYS, is attempted for the small-size gas turbine engine rotor, and the analysis capability and limitations of its rotordyamics module are evaluated for further improvement of the module. As the preliminary procedure, the rotordyamic analysis capability of ANSYS was tested and evaluated with the reference models of the well-known dynamics. The limitations in application of the rotordynamics module were then identified. Under the current capability and limitations of ANSYS, it is shown that Lee diagram, a new frequency-speed diagram enhanced with the concept of $H{\infty}$ in rotating machinery, can be indirectly obtained from FRFs computed from harmonic response analysis of ANSYS. Finally, it is demonstrated based on the modeling and analysis method developed in the process of the S/W verification that the conventional Campbell diagram, Lee diagram, mode shapes and critical speeds of the small-size gas turbine engine rotor can be computed using the ANSYS rotordynamics module.

증기터빈 블레이드의 공진 방지를 위한 실험 연구 (An Experimental Study for Preventing the Resonance of Steam Turbine Blade)

  • 하현천;이동진;류석주
    • 소음진동
    • /
    • 제11권3호
    • /
    • pp.410-415
    • /
    • 2001
  • This paper describes an experimental analysis for improving the stability of blade failure due to the vibration resonance, which happens in the low-pressure steam turbine. Some cracks due to high cycle fatigue were found in the blades of a low-pressure turbine after long time operation. Impact test showed that such failure was mainly caused by the resonance. In other words, since one of the natural frequencies of the grouped blade is very close to the excitation frequency of the nozzle, the resonant vibration leads to a large amplitude of displacement and results in a large amount of stress that may cause fatigue failures in the blades. It is interesting that the blade failures occur only at blades neighboring with the nodal points of the natural vibration mode whose natural frequency is close to the nozzle passing frequency. The effective methods for increasing the reliability against the blade vibration are a heightening the fatigue limit of the blade using an advanced material and a removing the resonance away from the operating speed. It is well known that the removal of theresonance could be obtained by the installation of different types of shrouds, wires, and links between the blades as well as by the chance of the number of nozzles. In the present work, two kinds of modification for avoiding the resonance haute been considered; 1) slot-type finger, 2) long span cover. Full-scale mockup tests have been performed in order to confirm the verification for modification in the shop. Test results show that the use of long span cover is very useful to change the natural frequencies of the grouped blade and to avoid the resonance effectively.

  • PDF

하이브리드형 고분자전해질 연료전지 시스템의 부분부하 성능해석 (Analysis of Part Load Performance of a Hybrid PEMFC System)

  • 지승원;유병준;김동섭;손정락;이영덕;안국영
    • 대한기계학회논문집B
    • /
    • 제32권11호
    • /
    • pp.849-855
    • /
    • 2008
  • The paper addresses modeling and analysis of the part load performance of a hybrid fuel cell system integrating a polymer electrolyte membrane fuel cell(PEMFC) and a gas turbine(GT). The system is a pressurized one where the working pressure of the PEMFC is higher than the ambient pressure. In addition to the two major components, the system also includes auxiliary parts such as a steam reformer, a humidifier, and afterburner and so on. Based on design analysis, component off-design models are incorporated in the analysis program and part load operation is simulated. The mode for the part load operation of the PEMFC/GT hybrid system is a variable rotational speed operation. The operating characteristics and variations in the system efficiency and component performance parameters at part load are analyzed.

모델 변천에 따른 가스터빈 1단 버켓의 손상경향 분석 (Analysis of Damage Trend for Gas Turbine 1st Bucket Related to the Change of Models)

  • 김문영;박상열;양성호;최희숙;고원;송국현
    • 대한기계학회논문집A
    • /
    • 제31권6호
    • /
    • pp.718-724
    • /
    • 2007
  • Some of gas turbine model of 7F-Class has constructed and is operating with units domestically. Non-destructive testing (NDT) is one of the methods being used to inspect damage $1^{st}$ stage bucket and review damage trends. We also analyze damage configuration and microstructure according to material and compare with pape of electric power research institute (EPRI). The damaged mode could be determined by leveraging failure analysis. Especially, configuration uprate of bucket is not only to prevent damage during operation but also avoid domestic manufacturing by the competitors. Modifications were mainly concentrated on surfaces such as cooling hole and bucket tips. Analyzing of bucket damage, the earlier model of 7F-Class used with one cycle with equivalent operation hour (EOH), has various cracking of the bucket surface. Bucket damage of new model is centered on tip area (54%) as analyzed by EPRI research. We conclude that improving bucket configuration would increase repair rate on the bucket tip.

Supervisory Control for Energy Management of Islanded Hybrid AC/DC Microgrid

  • Mansour, Henda Ben;Chaarabi, Lotfi;Jelassi, Khaled;Guerrero, Josep M.
    • International Journal of Computer Science & Network Security
    • /
    • 제22권3호
    • /
    • pp.355-363
    • /
    • 2022
  • This paper presents the modeling for islanded hybrid AC/DC microgrid and the verification of the proposed supervisory controller for energy management for this microgrid. The supervisory controller allows the microgrid system to operate in different power flows through the proposed control algorithm, it has several roles in the management of the energy flow between the different components of the microgrid for reliable operation. The proposed microgrid has both essential objectives such as the maximum use of renewable energies resources and the reduction of multiple conversion processes in an individual AC or DC microgrids. The microgrid system considered for this study has a solar photovoltaic (PV), a wind turbine (WT), a battery (BT), and a AC/DC loads. A small islanded hybrid AC/DC microgrid has been modeled and simulated using the MATLAB-Simulink. The simulation results show that the system can maintain stable operation under the proposed supervisory controller when the microgrid is switched from one operating mode of energy flow to another.

Analysis of Operating Characteristics in Tidal Power Generation According to Tide Level

  • Hong, Jeong-Jo;Oh, Young-sun
    • International Journal of Contents
    • /
    • 제18권1호
    • /
    • pp.76-84
    • /
    • 2022
  • Tidal power generation plays a critical role in reducing greenhouse gas emissions. It uses a tidal force generated by gravitational force between the moon, the earth, and the sun. The change of seawater height generates the tide-generating force, and the magnitude of the change is the tide level. The tide level change has the same period as the tide-generating force twice a day, every 29.5 days, every year, and every 18.6 years. Sihwa Lake Tidal Power Station is Korea's first tidal power plant that began commercial power generation in August 2011 and has been accumulating a large volume of data on electricity production, power generation sales, sluice displacement, and tide levels. The purpose of this paper was to analyze the impact of the inefficiency factors affecting production and the tidal level change on tidal power generation and their characteristics using Sihwa Lake Tidal Power's operational performance data. Throughout this paper we show that tidal power generating operation is accurately predicting the trends of magnitude of tidal force to be periodical for each day. determining the drop to initiate the water turbine generator factoring the constraints on the operation of Sihwa Lake, and reflecting the water discharge through the floodgate and water turbine during the standby mode in the power generation plan to be in the optimal condition until the initiation of the next power generation can maximize power generation.