• Title/Summary/Keyword: tungsten lamp

Search Result 53, Processing Time 0.029 seconds

Noninvasive blood glucose monitoring system based on NIR spectroscopy with a contact pressure control device

  • Kang, Na-Roo;Baek, Ju-Hyun;Woo, Young-Ah;Kim, Hyo-Jin
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.67.3-68
    • /
    • 2003
  • The purpose of this study is to improve repeatability of a non-invasive blood glucose measurement. The portable NIR system that was newly integrated by our lab includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector, which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of finger tip were recorded by using a fiber optic probe. The probe was fixed in the system and subjects put their finger on the probe head. (omitted)

  • PDF

Basic Study on the Development of Analytical Instrument for Liquid Pig Manure Component Using Near Infra-Red Spectroscopy (근적외선 분광법을 이용한 돈분뇨 액비 성분분석기 개발을 위한 기초 연구)

  • Choi, D.Y.;Kwag, J.H.;Park, C.H.;Jeong, K.H.;Kim, J.H.;Song, J.I.;Yoo, Y.H.;Chung, M.S.;Yang, C.B.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.2
    • /
    • pp.113-120
    • /
    • 2007
  • This study was conducted to measure Nitrogen(N), Phosphate($P_2O_5$), Potassium ($K_2O$), Organic matter(OM) and Moisture content of liquid pig manure by Near Infrared Spectroscopy(NIRS) and to develop an alternative and analytical instrument which are used for measurement of N, $P_2O_5$, $K_2O$, OM, and Moisture contents for liquid pig manure. The liquid pig manure sample's transmittance spectra were measured with a NIRS in the wavelength range of 400 to 2,500 nm. Multiple linear regression and partial least square regression were used for calibrations. The correlation coefficient(RSQ) and standard error of calibration(SEC) obtained for nitrogen were 0.9190 and 2.1649, respectively. The RSQ for phosphate, potassium, organic matter and moisture contents were 0.9749, 0.5046, 0.9883 and 0.9777, and the SEC were 0.5019, 1.9252, 0.1180 and 0.0789, respectively. These results are indications of the rapid determination of components of liquid pig manure through the NIR analysis. The simple analytical instrument for liquid pig manure consisted of a tungsten halogen lamp for light source, a sample holder, a quartz cell, a SM 301 spectrometer for spectrum analyzer, a power supply, an electronics, a computer and a software. Results showed that the simple analytical instrument that was developed can approximately predict the phosphate, organic matter and moisture content of the liquid pig manure when compared to the analysis taken by NIRS. The low predictability value of potassium however, needs further investigation. Generally, the experiment proved that the simple analytical instrument was reliable, feasible and practical for analyzing liquid pig manure.

  • PDF

A Thermal Model for Silicon-on-Insulator Multilayer Structure in Silicon Recrystallization Using Tungsten Lamp (텅스텐 램프를 이용한 실리콘 재결정시의 SOI 다층구조에 대한 열적모델)

  • 경종민
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.5
    • /
    • pp.90-99
    • /
    • 1984
  • A onetimensional distribution of the temperature and the heat source in the SOI (silicon-on-insulator) multi-layer structure illuminated by tungsten lamps from both sides was obtained by solving the heat equation in steady state on a finite difference grid using successive over-relaxation method. The heat source distribution was obtained by considering such features as spectral components of the light source, multiple reflection at the internal interfaces, temperature and frequency dependence of the light absorption coefficient, etc. The front and back surface temperatures, which are boundary conditions for the heat equation, were derived from a requirement that they satisfy the radiation conditions. The radiation flux as well as the conduction flux was considered in modelling the thermal behaviour at the internal interfaces. Since the temperature and the heat source profiles are strongly dependent upon each other, the calculation of each profile was iterated using the updated profile of the other until they are consistent with each other. The experimental temperature at the front surface of the wafer as measured by Pyrometer was about 1200$^{\circ}$K, while the simulated temperature was 1120$^{\circ}$K.

  • PDF

Synthesis of W18O49 Phase by Carbothermal Reduction of Tungsten Oxide and its Field Emission Characteristics

  • Yang, Hyo-Seung;Park, Hoon;Kim, Hyoung-chul;Ahn, Jae-Pyoung;Huh, Moo-Young;Park, Jong-Ku
    • Journal of Powder Materials
    • /
    • v.11 no.3
    • /
    • pp.253-258
    • /
    • 2004
  • We report a carbothermal reduction process for massive synthesis of monolithic W$_{18}$O$_{49}$ phase from tungsten oxide in the presence of carbon source. Carbon black powder was used as a carbon source and added to WO$_3$ by 40 weight percent. Bundles of W$_{18}$O$_{49}$ rods were formed over the temperature range of 80$0^{\circ}C$$^{\circ}C$ to 90$0^{\circ}C$. Pure W$_{18}$O$_{49}$ bundles could be separated from the mixture of W$_{18}$O$_{49}$ and residual carbon black powder. Field emission character of W$_{18}$O$_{49}$ phase was determined using the extracted W$_{18}$O$_{49}$ rods. Flat lamp fabricated from the W$_{18}$O$_{49}$ rods showed the turn-on field of 9.3 V/${\mu}m$.

Design of IGRINS Wavelength Calibration System

  • Oh, Hee-Young;Pak, Soo-Jong;Yuk, In-Soo;Park, Chan;Lee, Sang-On;Chun, Moo-Young;Kim, Kang-Min;Lee, Sung-Ho;Pyo, Tae-Soo;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.41.1-41.1
    • /
    • 2010
  • IGRINS (the Immersion GRating Infrared Spectrograph) is a high resolution infrared spectrograph which is being developed by a collaboration of the University of Texas, the Korea Astronomy and Space Science Institute, and Kyung Hee University. The wavelength calibration unit of IGRINS will be situated between the telescope flange and IGRINS dewar. It will include Th-Ar hallow cathode lamp, optical elements, and gas absorption cell for the case that requires precise calibration (e.g., radial velocity observation). The system will also use a tungsten halogen lamp in an integrating sphere as a blackbody source for the flat-field imaging. IGRINS will be placed initially on the McDonald 2.7m Harlan J. Smith telescope and later on 4-8m class telescopes. We present an overview of the plan for the wavelength calibration sources and of the development process for the optical and mechanical design of the IGRINS calibration system.

  • PDF

An Introduction of an Apparatus for Rapid Heating Coal Gasification (Cahn Balance를 이용한 급속 가열방식의 석탄가스화 장치 소개)

  • Lee, Joong-Kee;Lee, Sung-Ho;Lim, Tae-Hoon
    • Applied Chemistry for Engineering
    • /
    • v.2 no.4
    • /
    • pp.393-398
    • /
    • 1991
  • An experimental reactor system was devised and employed to examine catalytic coal gasification. A 4-kw tungsten halogen lamp heater combinded with a graphite sample basket coated with silicon nitride film made rapid heating and cooling possible. Also a small graphite cap on the thermocouple tip which located just beneath the sample basket helped remarkably to read real temperatures. Silicon nitride film on the basket and the cap showed very good protection against the reaction between graphite and oxidant gases during the experiments. The weight of specimen could be continuously measured without disturbance.

  • PDF

NEW DEVELOPED PORTABLE NEAR INFRARED (NIR) SYSTEM USING MICROSPECTROMETER

  • Woo, Young-Ah;Ha, Tae-Kyu;Kim, Jae-Min;Kim, Hyo-Jin
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1123-1123
    • /
    • 2001
  • In recent years, a miniature spectrometer has been extensively developed due to the marriage of fiber optics and semiconductor detector array. This type of miniature spectrometer has advantages of low price and robustness due to the capability of mass production and no moving parts are required such as lenses, mirrors and scanning monochromator. These systems are ideal for use in teaching labs, process monitoring and field analyses. A portable near infrared (NIR) system has been developed for qualitative and quantitative analysis. This system includes a tungsten halogen lamp for light source, a fiber optics connected a light source, and a sample module to the microspectrometer, The size of spectrometer can be as small as 2.5 cm x 1.5 cm x 0.1 cm. Wavelength ranges can be chosen as 360-800 nm, 800-1100 nm and 1100-1900 nm depending on the type of detector. The software consists of various tools for multivariate analysis and pattern recognition techniques. To evaluate the system, long and short-term stability, wavelength accuracy, and stray light have been investigated and compared with conventional scanning type NIR spectrometer. This developed system can be sufficiently used for quantitative and qualitative analysis for various samples such as agricultural product, herbal medicine, food, petroleum, and pharmaceuticals, etc.

  • PDF

The Effect of Antioxygenic substances in Pine Needles on the Photooxidation of Linoleic Acid (송옆중의 항산화성 물질이 리놀산의 광산화에 미치는 영향)

  • Paik, Taik-Hong;Lee, Meen-Soo;Yi, Jun-Heung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.25-30
    • /
    • 1987
  • In order to investigate the effect to antioxygenic substances in Pine Needles on the photooxidation of linoleic acid (linoleic acid 100mg/10ml ethanol) added antioxidants and antioxygenic substances in Pine Needles was irradiated by the tungsten lamp attached with red fitter. The Photo oxidation of linoleic acid (LA) was conformed with Lea method and rhodan method. The following results were obtained: 1. Photooxidation of LA was greatly increased the presence of photosensitizer. However the Photo oxidation of LA without photosensitizer was smoothly increased by the irradiation. 2. The Photo oxidation of LA without irradiation occured quite lately whether photosensitizer was present or absent. 3. Photooxidation of LA under the presence of photosensitizer was inhibited by the addition of $dl-{\alpha}-tocopherol$ and the acetone fraction of methanol extract of Pine Needles but inhibited by BHT. Photooxidation of LA increased gradually as the addition of BHT increased but decreased gradually as that of acetone fraction increased.

Development of Spectral Irradiance Measurement System (분광복사조도 측정 장치 개발)

  • Seo, Jung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.48-53
    • /
    • 2004
  • Spectral irradiance measurement system was developed to measure the spectral irradiance of optical sources in the wavelength range from 250[nm] to 1600[nm]. Our system is composed of source system, fore-optics, monochromator system, optical detector system, and automatic control system. Optical detector system with PMT, Si, InGaAs, and IR enhanced InGaAs detectors is used to measure the wide spectrum of optical sources in ultraviolet visible, and infrared wavelength regions. Spectral irradiance of the 1[kW] quartz-halogen tungsten lamp was measured and compared in the wavelength range from 250[nm] to 1600[nm]. The differences between our results and those reported by NIST are below 3[%], 3.5[%], and 5[%] in the wavelength range of 450∼700[nm], 700∼1600[nm], 250∼400[nm], respectively.

A Study on the Performance Characteristics of Portable Analyzer for Determination of Sugar Content in Citrus Unshiu using Near Infrared Spectroscopy (근적외선 분광기술을 이용한 휴대용 감귤 당도 선과기 성능특성에 관한 연구)

  • Yoon, Sung-Un;Ma, Sang-Dong;Kim, Myung-Yun;Kim, Jae-Yeol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.5
    • /
    • pp.1-6
    • /
    • 2006
  • The purpose of this study is to develop to portable near infrared analyzer measuring the sugar content of the fruits on a tree before harvesting ones. The portable near infrared system consists of a tungsten lamp, a coaxial optical fiber bundle and a multi-channel detector, which has 256 pixels and a concave transmission grating. Reflectance NIR spectra of orange were recorded by using a coaxial optical fiber bundle. The spectra were collected over the spectral range $400{\sim}1100nm$. Partial least squares regression(PLSR) was applied for a calibration and validation for determination of sugar contents. The multiple correlation coefficient was 0.99 and standard errors of calibration(SEC) was 0.069 brix. The calibration model predicted the sugar content for validation set with standard errors of prediction(SEP) of 0.092 brix. The sugar content in fruits was successfully quantified using the portable near infrared analyzer.