• Title/Summary/Keyword: tube-support

Search Result 285, Processing Time 0.023 seconds

Preparation and Characterization of $TiO_2$ Membranes for Microfiltration ($TiO_2$ 정밀여과막의 제조 및 특성)

  • 한상욱;최세영;현상훈;조철구;강한규
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.6
    • /
    • pp.700-708
    • /
    • 1996
  • TiO2 membranes for microfiltration were prepared on $\alpha$-alumina support tube by slurry coating. The coating layer was obtained by flowing TiO2 slip on the inner surface of the alumina support. TiO2 membranes were heat-treated at 9$25^{\circ}C$ for 2 hrs. The thickness of the unsupported membrane was about 10${\mu}{\textrm}{m}$. The mean pore diameter of the membranes were 0.09 and 0.15${\mu}{\textrm}{m}$ respectively and the pure water flux was 900~1,200ι/m2.hr at room temperature and 1 bar. For a possible application of oily wastewater treatement an kerosene/wa-ter emulsion was separated in terms of flux and removal efficiency. In 60 min of operating time the flux of TiO2 membranes was 50~100 ι/m2.hr and removal efficiency was over 97% at 3kgf/cm2 of operating pres-sure and 600 ml/min of flow rate. TiO2 membranes could be recycled by reheat treatments at $600^{\circ}C$ for 2 hrs.

  • PDF

Analysis of public opinion in the 20th presidential election using YouTube data (유튜브 데이터를 활용한 20대 대선 여론분석)

  • Kang, Eunkyung;Yang, Seonuk;Kwon, Jiyoon;Yang, Sung-Byung
    • Journal of Intelligence and Information Systems
    • /
    • v.28 no.3
    • /
    • pp.161-183
    • /
    • 2022
  • Opinion polls have become a powerful means for election campaigns and one of the most important subjects in the media in that they predict the actual election results and influence people's voting behavior. However, the more active the polls, the more often they fail to properly reflect the voters' minds in measuring the effectiveness of election campaigns, such as repeatedly conducting polls on the likelihood of winning or support rather than verifying the pledges and policies of candidates. Even if the poor predictions of the election results of the polls have undermined the authority of the press, people cannot easily let go of their interest in polls because there is no clear alternative to answer the instinctive question of which candidate will ultimately win. In this regard, we attempt to retrospectively grasp public opinion on the 20th presidential election by applying the 'YouTube Analysis' function of Sometrend, which provides an environment for discovering insights through online big data. Through this study, it is confirmed that a result close to the actual public opinion (or opinion poll results) can be easily derived with simple YouTube data results, and a high-performance public opinion prediction model can be built.

Weaning Following a 60 Minutes Spontaneous Breathing Trial (1시간 자가호흡관찰에 의한 기계적 호흡치료로부터의 이탈)

  • Park, Keon-Uk;Won, Kyoung-Sook;Koh, Young-Min;Baik, Jae-Jung;Chung, Yeon-Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.361-369
    • /
    • 1995
  • Background: A number of different weaning techniques can be employed such as spontaneous breathing trial, Intermittent mandatory ventilation(IMV) or Pressure support ventilation(PSV). However, the conclusive data indicating the superiority of one technique over another have not been published. Usually, a conventional spontaneous breathing trial is undertaken by supplying humidified $O_2$ through T-shaped adaptor connected to endotracheal tube or tracheostomy tube. In Korea, T-tube trial is not popular because the high-flow oxygen system is not always available. Also, the timing of extubation is not conclusive and depends on clinical experiences. It is known that to withdraw the endotracheal tube after weaning is far better than to go through any period. The tube produces varying degrees of resistance depending on its internal diameter and the flow rates encountered. The purpose of present study is to evaluate the effectiveness of weaning and extubation following a 60 minutes spontaneous breathing trial with simple oxygen supply through the endotracheal tube. Methods: We analyzed the result of weaning and extubation following a 60 minutes spontaneous breathing trial with simple oxygen supply through the endotracheal tube in 18 subjects from June, 1993 to June, 1994. They consisted of 9 males and 9 females. The duration of mechanical ventilation was from 38 hours to 341 hours(mean: $105.9{\pm}83.4$ hours). In all cases, the cause of ventilator dependency should be identified and precipitating factors should be corrected. The weaning trial was done when the patient became alert and arterial $O_2$ tension was adequate($PaO_2$ > 55mmHg) with an inspired oxygen fraction of 40%. We conducted a careful physical examination when the patient was breathing spontaneously through the endotracheal tube. Failure of weaning trial was signaled by cyanosis, sweating, paradoxical respiration, intercostal recession. Weaning failure was defined as the need for mechanical ventilation within 48 hours. Results: In 19 weaning trials of 18 patients, successful weaning and extubation was possible in 16/19(84.2 %). During the trial of spontaneous breathing for 60 minutes through the endotracheal tube, the patients who could wean developed slight increase in respiratory rates but significant changes of arterial blood gas values were not noted. But, the patients who failed weaning trial showed the marked increase in respiratory rates without significant changes of arterial blood gas values. Conclusion: The result of present study indicates that weaning from mechanical ventilation following a 60 minutes spontaneous breathing with $O_2$ supply through the endotracheal tube is a simple and effective method. Extubation can be done at the same time of successful weaning except for endobronchial toilet or airway protection.

  • PDF

Anterior Tracheoplasty -Two Cases Report- (전방 기관성형술 -2례 보고-)

  • Sun, Kyung;Lee, Seo-Won;Kim, Joung-Taek;Kim, Kwang-Ho;Lim, Hyun-Kyoung
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.675-680
    • /
    • 1999
  • We describe here two cases of anterior tracheoplasty utilizing an autologous pericardial patch. One patient was a 9 year-old female who had a congenital long tracheal stenosis associated with major vascular anomalies including pulmonary artery sling. One-stage correction was done under the support of an extracorporeal membrane oxygenation system. She required a prolonged ventilation support for 10 days postoperatively until the implanted pericardium was fixed to the mediastinal structures. The other patient was a 8 year-old male who had acquired tracheal stenosis following a complicated tracheostomy. By applying additional support over the pericardial patch with the costal cartilage, an endotracheal tube could be removed immediately after the operation. Both patients have been doing well in a postoperative follow-up of over a year, and there have been evidences of growth in the reconstructed trachea.

  • PDF

Types and Yields of Carbon Nanotubes Synthesized Depending on Catalyst Pretreatment

  • Go, Jae-Seong;Lee, Nae-Seong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.17.2-17.2
    • /
    • 2011
  • Double-walled carbon nanotubes (DWCNTs) were grown with vertical alignment on a Si wafer by using catalytic thermal chemical vapor deposition. This study investigated the effect of pre-annealing time of catalyst on the types of CNTs grown on the substrate. The catalyst layer is usually evolved into discretely distributed nanoparticles during the annealing and initial growth of CNTs. The 0.5-nm-thick Fe served as a catalyst, underneath which Al was coated as a catalyst support as well as a diffusion barrier on the Si substrate. Both the catalyst and support layers were coated by using thermal evaporation. CNTs were synthesized for 10 min by flowing 60 sccm of Ar and 60 sccm of H2 as a carrier gas and 20 sccm of C2H2 as a feedstock at 95 torr and $750^{\circ}C$. In this study, the catalyst and support layers were subject to annealing for 0~420 sec. As-grown CNTs were characterized by using field emission scanning electron microscopy, high resolution transmission electron microscopy, Raman spectroscopy, and atomic force microscopy. The annealing for 90~300 sec caused the growth of DWCNTs as high as ~670 ${\mu}m$ for 10 min while below 90 sec and over 420 sec 300~830 ${\mu}m$-thick triple and multiwalled CNTs occurred, respectively. Several radial breathing mode (RBM) peaks in the Raman spectra were observed at the Raman shifts of 112~191 cm-1, implying the presence of DWCNTs, TWCNTs, MWCNTs with the tube diameters 3.4, 4.0, 6.5 nm, respectively. The maximum ratio of DWCNTs was observed to be ~85% at the annealing time of 180 sec. The Raman spectra of the as-grown DWCNTs showed low G/D peak intensity ratios, indicating their low defect concentrations. As increasing the annealing time, the catalyst layer seemed to be granulated, and then grown to particles with larger sizes but fewer numbers by Ostwald ripening.

  • PDF

The Usefulness of Nasal Packing with Vaseline Gauze and Airway Silicone Splint after Closed Reduction of Nasal Bone Fracture

  • Kim, Hyo Young;Kim, Sin Rak;Park, Jin Hyung;Han, Yea Sik
    • Archives of Plastic Surgery
    • /
    • v.39 no.6
    • /
    • pp.612-617
    • /
    • 2012
  • Background Packing after closed reduction of a nasal bone fracture causes inconvenient nasal obstruction in patients. We packed the superior meatus with Vaseline gauze to support the nasal bone, and packed the middle nasal meatus with a Doyle Combo Splint consisting of an airway tube, a silastic sheet, and an expandable sponge to reduce the inconvenience. In addition, we aimed to objectively identify whether this method not only enables nasal respiration but also sufficiently supports the reduced nasal bone. Methods Nasal ventilation was measured via spirometry 1 day before surgery and compared to 1 day after surgery. To compare support of the reduced nasal bone by the 2 methods, 2 plastic surgeons assessed the displacementon X-rays taken after the surgery and after removing the packing. The extent of nasal obstruction, dry mouth, sleep disturbance, headache, and swallowing difficulty were compared with visual analog scales (VAS) on a pre-discharge survey. Results In the experimental group, the nasal respiration volume 1 day after surgery remained at $71.3%{\pm}6.84%$ on average compared to 1 day prior to surgery. Support of the reduced bone in the experimental group ($2.80{\pm}0.4$) was not significantly different from the control group ($2.88{\pm}0.33$). The VAS scores for all survey items were lower in the experimental group than in the control group, where a lower score indicated a lower level of inconvenience. Conclusions The nasal cavity packing described here maintained objective measures of nasal respiration and supported the reduced bone similar to conventional methods. Maintaining nasal respiration reduced the inconvenience to patients, which demonstrates that this packing method is useful.

Shape Control of Anodic Aluminum Oxide and Effect as Support of Silicon Powder Electrode (양극산화알루미늄의 형상제어와 이를 이용한 실리콘 분말 전극 지지체 효과)

  • Song, Ju-Seok;Ha, Jong-Keun;Kim, Yoo-Young;Park, Dong-Kyu;Ahn, In-Shup;Ahn, Jou-Hyeon;Cho, Kwon-Koo
    • Journal of Powder Materials
    • /
    • v.22 no.4
    • /
    • pp.240-246
    • /
    • 2015
  • Anodic aluminum oxide (AAO) has been widely used for the development and fabrication of nano-powder with various morphologies such as particle, wire, rod, and tube. So far, many researchers have reported about shape control and fabrication of AAO films. However, they have reported on the shape control with different diameter and length of anodic aluminum oxide mainly. We present a combined mild-hard (or hard-mild) anodization to prepare shape-controlled AAO films. Two main parameters which are combination mild-hard (or hard-mild) anodization and run-time of voltage control are applied in this work. The voltages of mild and hard anodization are respectively 40 and 80 V. Anodization was conducted on the aluminum sheet in 0.3 mole oxalic acid at $4^{\circ}C$. AAO films with morphologies of varying interpore distance, branch-shaped pore, diameter-modulated pore and long funnel-shaped pore were fabricated. Those shapes will be able to apply to fabricate novel nano-materials with potential application which is especially a support to prevent volume expansion of inserted active materials, such as metal silicon or tin powder, in lithium ion battery. The silicon powder electrode using an AAO as a support shows outstanding cycle performance as 1003 mAh/g up to 200 cycles.

The Impact of Social Media Functionality and Strategy Alignment to Small and Medium Enterprises (SMEs) Performance: A Case Study in Garment SME in East Java

  • Mahendrawathi ER;Nanda Kurnia Wardati
    • Asia pacific journal of information systems
    • /
    • v.30 no.3
    • /
    • pp.568-589
    • /
    • 2020
  • Recently, Social media has become a concern for businesses, including Small and Medium Enterprises (SMEs). SMEs began to adopt social media to support their performance. To benefit from the application of social media, SMEs must implement the right strategy. This study aims to analyze the factors that influence the use of social media in SMEs. Furthermore, alignment between social media functionalities and strategies and their effect on SME's performance are investigated. A case study is conducted in Gymi, a garment SMEs in East Java, Indonesia. The data collection includes interviews with the owner of SMEs, observations, and document analysis. Data analysis is performed by pattern matching, which matches the patterns from the literature with data from the case study. The results of this study show that cost-effectiveness, interactivity, and compatibility are factors that influence the use of social media in Gymi. The social media used by Gymi are Instagram, Facebook, YouTube, WhatsApp, and LINE. However, the main social media used to support Gymi's functions is Instagram. Gymi has a relatively good social media strategy as it has defined a specific goal, target audience, and channel selection for social media (Instagram). It also has specific resources and policies to handle social media. Gymi monitors and evaluates their social media content activities. These strategies are aligned with the Instagram feature used to support Gymi's function, particularly marketing, sales, customer service, and to some extent, internal operation. The alignment contributes to Gymi's performance measured by the increase in reputation (number of Instagram followers) and sales.

The Effect of Porous Support and Intermediate Layer on the Silica-zirconia Membranes for Gas Permeation Performance (실리카-지르코니아 분리막 성능에 대한 다공성 지지체와 중간층의 영향)

  • Lee, Hye Ryeon;Seo, Bongkuk
    • Membrane Journal
    • /
    • v.25 no.1
    • /
    • pp.15-26
    • /
    • 2015
  • In this study, porous metal (O.D. = 10 mm, length = 10 mm, 316 L SUS, Mott Corp.) and ${\alpha}$-alumina tube (O.D. = 10 mm, length = 50 mm, Pall, German) support was modified with suspension sols, which were consisted of $3{\sim}4{\mu}m$ and 150 nm size of ${\alpha}$-alumina particle in the water or silica-zirconia colloidal sol. The porous support was fabricated by dip coating method for 5 seconds with suspension of alumina particles. After drying at $100^{\circ}C$ for 1 h, it was calcined at $550^{\circ}C$ for 30 min. It was repeated several times in order to decrease big pore on support. The surface roughness and largest pore size on the porous support was decreased by increasing coating times with $3{\sim}4{\mu}m$ size of ${\alpha}$-alumina particle and alumina coating with 150 nm size of ${\alpha}$-alumina particle served as further smoothening the surface and decreasing the pore size of the substrate. And the silica-zirconia membranes were successfully prepared on the modified porous metal and ${\alpha}$-alumina supports, and showed hydrogen permeance in the range of $1.8-8.4{\times}10^{-4}mol{\cdot}m^{-2}{\cdot}s^{-1}{\cdot}Pa^{-1}$ and $3.3-5.0{\times}10^{-5}mol{\cdot}m^{-2}{\cdot}s^{-1}{\cdot}Pa^{-1}$, respectively.

Silicone Rubber Membrane Bioreactors for Bacterial Cellulose Production

  • Onodera, Masayuki;Harashima, Ikuro;Toda, Kiyoshi;Asakura, Tomoko
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.5
    • /
    • pp.289-294
    • /
    • 2002
  • Cellulose production by Acetobacter pasteurianus was investigated in static culture using four bioreactors with silicone rubber membrane submerged in the medium. The shape of the membrane was flat sheet, flat sack, tube and cylindrical balloon. Production rate of cellulose as well as its yield on consumed glucose by the bacteria grown on the flat type membranes was approximately ten-fold greater than those on the non-flat ones in spite of the same membrane thickness. The membrane reactor using flat sacks of silicone rubber membrane as support of bacterial pellicle can supply greater ratio of surface to volume than a conventional liquid surface culture and is promising for industrial production of bacterial cellulose in large scale.