• Title/Summary/Keyword: tube internal

Search Result 588, Processing Time 0.026 seconds

A Literatural Study on the Traditional Korean Medical Physiotherapy (한방물리요법에 대한 문헌적 고찰)

  • Choi, Bo-Mi;Hong, Seo-Young
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.2
    • /
    • pp.211-226
    • /
    • 2011
  • Objectives : The purpose of this study is to establish literatural evidence about traditional Korean medical physiotherapy through literatural review. Methods : Applicable paragraphs which were related to the traditional Korean medical physiotherapy were phrased from in "Hwang-je-nae-gyung(黃帝內經)", "Yumun-sa-chin(儒門事親)", "Geum-guei-yo-ryack(金匱要略)", "Eui-hack-ip-mun(醫學入門)", "Gyung-ack-jeon-seo(景岳全書)", "Eui-hack-gang-mock(醫學綱目)", "Dong-eui-bo-gam(東醫寶鑑)" where were archiving of Oriental or Korean medicine literatures. Searched paragraphs were analysed for establishing historical and theoretical bases of Korean medical physiotherapy. Results : 1. Theromtherapy is originated from yu(熨), hot hand, warm, water bath, warm earth, fumigation, lamp, torchlight and brazier. Matching indications are various musculoskeletal pain and diseases, skin diseases such as chronic inflammation, frostbite, gynecological and urogenital diseases such as uterine myoma, lower abdominal pain, metrorrhagia, breast diseases, digestive tract diseases such as vomiting, diarrhea, stomachache and also it treats cardiovascular disease. Other matching indications are sunstroke, rhinorrhea, psycosis and anal pain. And it used helping acupuncture therapy. 2. Cryotherapy is originated from lengfu(冷敷), lengtie(冷貼), cold stone and cold water. Matching indications are various fever disease, skin diseases such as acute inflammation, wound, fever skin disease, otorhinolaryngological diseases such as acute sore throat, otitis, stomatitis, nasal bleeding and contusions, abrasions, burn and dysuria. In addition, it treats extremity coldness, chillness, stomachache caused to accumulate fever. 3. Physiotherapy by circulating meridian system is originated from manipulation such as pushing, massage and beating to therapy point. Matching indications are musculoskeletal diseases such as various muscular pain, heavy sensation, convulsion, urogenital diseases such as dysuria, lower abdomen pain, digestive tract diseases such as stomachache, and paralysis due to blocked meridian system. And other matching indications are psycosis, leprosy, hypoesthesia, acute stroke. In addition it helps other therapy methods. In addition, the power of manipulation classify to strengthen and reduce. 4. Physiotherapy by balancing meridian system is originated from sunshine, magnet, horn, bamboo and tube. Sunshine helps improving self's care and cure inflammatory skin disease. Magnet's matching indications are paralysis, various injuries, abscess, fever and eye disease. Cupping therapy treats to skin diseases and internal diseases such as tuberculosis. Conclusions : Traditional Korean medical physiotherapy was widely used in traditional Korean medicine since ancient time based on the traditional Korean medical principle and anatomical knowledge. With modern physiotherapy and traditional Korean medicine together, effects of treatment are enhanced. And traditional Korean medical physiotherapy is appropriated to world physiotherapy's expectation.

Evaluation of Neutron Flux Distributions of SMART-P IST Region for the Design of Ex-Core Detector (SMART 연구로 노외계측기 설계를 위한 IST 영역의 중성자속 분포 평가)

  • Koo, Bon-Seung;Kim, Kyo-Youn;Lee, Chung-Chan;Zee, Sung-Quun
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.55-60
    • /
    • 2005
  • The evaluation of neutron flux distribution was performed for the ex-core detector design of SMART-P. DORT and MCNP code were used for the calculation of energy-dependent neutron flux distribution at 100% full power condition. Two code results show that maximum thermal flux appears at the $1^{st}$ water region in IST region and agree within 10% difference. In addition, another evaluation was performed code with assumptions that cote was composed of fission source and control rod without fuel assemblies. These assumptions make neutron count rate to be minimized. As a results, maximum thermal flux showed $6.99{\times}10^{-2}(n/cm^2-sec)$, when the strength of initial fission source was assumed as $1.0{\times}10^8(n/sec)$. The main reason of these results is due to the thermalization of fast neutrons in the water region and thermal flux is proportional to 80% of total neutron flux. Therefore, optimization of filler material of detector guide tube, position of installation and axial length of detector segments is necessary for the design of ex-core detector to enhance the neutron count rate and above results could be used in ex-core detector design as a fluence requirement.

A Study of the Junior Nursing College Students실 Role during Clinical Practice (간호전문대학생들의 임상실습현장에서의 수행에 관한 연구 -실습의 내용 빈도를 중심으로-)

  • 권경남
    • Journal of Korean Academy of Nursing
    • /
    • v.13 no.3
    • /
    • pp.1-33
    • /
    • 1983
  • The role and function of nursing care nowadays, tend to acquire sophisicated technology because specialization has expended due to increase of the medical population and the improvement of national health standards. To implement nursing care independently as a professional nurse, the apprehension of specific knowledge and skill should be acquired during basic nursing education. So it is important for nursing education not only to include theory and actual techniques, but also to strengthen the practical training in the actual clinical setting. This study was carried out with the following objectives; 1. To survey the detailed content and frequency of actual nursing students display during their clinical training. 2. To investigate the detailed content and frequency of actual nursing behavior which students display in each clinical a area. 3. To identify the motive for selection of nursing as their major and to determine the degree of self confidence, extent of knowledge and recognition of nursing responsibility. 4. To observe the relationship between actual nursing behavior and each of the following; 1) Motive for selecting nursing as a major 2) Self confidence 3) Knowledge of nursing care 4) Recognition of nursing responsibility The conclusions of this study were as follows; 1. Among the detailed nursing behavior which junior nursing college students carry out in clinical training; taking respiration's showed the highest frequency, and taking body temperatures, blood pressures, and pulses and making beds were next in frequency in this order. 2. In detailed nursing behaviors according to clinical area; taking vital signs showed the highest frequency in the emergency room, pediatric ward, orthopedic ward, general surgical ward and internal medicine ward. However, in the operating room, assisting with endotracheal tube insertion and sterile techniques were showen to have the highest frequencies. In nursery, umbilical cord care and the measurement of body weight were the highest in frequency In neurosurgical ward, the measurement of vital signs, changing position and tracheostomy care were the highest in frequency. In obstetric and gynecological ward and in the delivery room, checking duration, intensity and frequency of contractions was the highest in frequency. 3. In regard to the motive for majoring in nursing, the aptitude and interest of the student had the highest percentage(32.86%), and self-confidence in nursing activities (M=3.36), knowledge in nursing activities.(M=3. 09), and the recognition of the nursing activity (M= 3.76) wire in the middle range. 4. When the detailed nursing behaviors were compared with motive, self confidence, knowledge and recognition, it was found that when the nursing behavior was difficult and regarding much endeavor although the motive was high, the frequency of the nursing behavior was rather low. But in the cases in which there was much self confidence and a high level of skill was required, nursing behavior was carried more frequently. When there was muck self confidence and skill was not required, the frequency of nursing behavior was rather low. In the cases of a high level of knowledge, the frequency of nursing behavior was low and when recognition for nursing behavior was given the frequency of nursing behavior was low.

  • PDF

Do-not-resuscitation in Terminal Cancer Patient (말기암환자에서 심폐소생술금지)

  • Kwon, Jung Hye
    • Journal of Hospice and Palliative Care
    • /
    • v.18 no.3
    • /
    • pp.179-187
    • /
    • 2015
  • For patients who are near the end of life, an inevitable step is discussion of a do-not-resuscitate (DNR) order, which involves patients, their family members and physicians. To discuss DNR orders, patients and family members should know the meaning of the order and cardiopulmonary resuscitation (CPR) which includes chest compression, defibrillation, medication to restart the heart, artificial ventilation, and tube insertion in the respiratory tract. And the following issues should be considered as well: patients' and their families' autonomy, futility of treatment, and the right for death with dignity. Terminal cancer patients should be informed of what futility of treatment is, such as a low survival rate of CPR, unacceptable quality of life after CPR, and an irremediable disease status. In Korea, two different law suits related to life supporting treatments had been filed, which in turn raised public interest in death with dignity. Since the 1980s, knowledge of and attitude toward DNR among physicians and the public have been improved. However, most patients are still alienated from the decision making process, and the decision is often made less than a week before death. Thus, the DNR discussion process should be improved. Early palliative care should be adopted more widely.

Effect of Operating Variables on the Morphology of Precipitated Calcium Carbonate in a Slurry Bubble Reactor (슬러리 기포탑 반응기에서 침강성 탄산칼슘의 모폴로지에 대한 조업변수들의 영향)

  • Hwang, Jung-Woo;Lee, Yoong;Lee, Dong-Hyun
    • Clean Technology
    • /
    • v.16 no.2
    • /
    • pp.124-131
    • /
    • 2010
  • Effects of $Ca(OH)_2$ concentration (0.16~0.64 wt%), surfactant concentration (2~16 wt%), total volumetric flow rate (3~6 L/min) and $CO_2$ volume fraction $(0.3{\sim}0.6)$ on morphology, crystal structure, mean particle diameter, aggregation and specific surface area of the precipitated $CaCO_3$ were investigated in the slurry bubble column reactor. Experiments were carried out in acrylic reactor ($0.11\;m-ID{\times}1.0\;m-high$) with a internal tube ($0.04\;m-ID{\times}1.0\;m-high$h). The reaction time of $CaCO_3$ synthesis decreased with adding Dispex N40 of the anionic surfactant. The reaction rate of $Ca(OH)_2$ increased with increasing the volumetric flow rate of $CO_2$. From SEM images, the single crystal of $CaCO_3$ increased with increasing the reaction rate in the saturated concentration of $Ca(OH)_2$ (0.16 wt %) and the concentration of Dispex N40 (2 wt%). The mean particle size of $CaCO_3$ varied with adding Dispex N40. In addition, the specific surface area of $CaCO_3$ increased with adding of surfactant (2 wt%) from $35m^2/g$ to $44m^2/g$ at the volumetric flow rate of $CO_2$ (0.9 L/min) and the concentration of $Ca(OH)_2$(0.64 wt %).

Material Discrimination Using X-Ray and Neutron

  • Jaehyun Lee;Jinhyung Park;Jae Yeon Park;Moonsik Chae;Jungho Mun;Jong Hyun Jung
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.167-174
    • /
    • 2023
  • Background: A nondestructive test is commonly used to inspect the surface defects and internal structure of an object without any physical damage. X-rays generated from an electron accelerator or a tube are one of the methods used for nondestructive testing. The high penetration of X-rays through materials with low atomic numbers makes it difficult to discriminate between these materials using X-ray imaging. The interaction characteristics of neutrons with materials can supplement the limitations of X-ray imaging in material discrimination. Materials and Methods: The radiation image acquisition process for air-cargo security inspection equipment using X-rays and neutrons was simulated using a GEometry ANd Tracking (Geant4) simulation toolkit. Radiation images of phantoms composed of 13 materials were obtained, and the R-value, representing the attenuation ratio of neutrons and gamma rays in a material, was calculated from these images. Results and Discussion: The R-values were calculated from the simulated X-ray and neutron images for each phantom and compared with those obtained in the experiments. The R-values obtained from the experiments were higher than those obtained from the simulations. The difference can be due to the following two causes. The first reason is that there are various facilities or equipment in the experimental environment that scatter neutrons, unlike the simulation. The other is the difference in the neutron signal processing. In the simulation, the neutron signal is the sum of the number of neutrons entering the detector. However, in the experiment, the neutron signal was obtained by superimposing the intensities of the neutron signals. Neutron detectors also detect gamma rays, and the neutron signal cannot be clearly distinguished in the process of separating the two types of radiation. Despite these differences, the two results showed similar trends and the viability of using simulation-based radiation images, particularly in the field of security screening. With further research, the simulation-based radiation images can replace ones from experiments and be used in the related fields. Conclusion: The Korea Atomic Energy Research Institute has developed air-cargo security inspection equipment using neutrons and X-rays. Using this equipment, radiation images and R-values for various materials were obtained. The equipment was reconstructed, and the R-values were obtained for 13 materials using the Geant4 simulation toolkit. The R-values calculated by experiment and simulation show similar trends. Therefore, we confirmed the feasibility of using the simulation-based radiation image.

Domestic Clinical Research Trends of Pharmacopuncture Treatment for Nerve Entrapment Syndroeme: A Scoping Review (포착신경병증의 약침치료에 대한 국내 임상 연구 동향: 주제범위 문헌고찰)

  • Woenhyung Lee;Hyeonjun Woo;Yunhee Han;Seungkwan Choi;Jungho Jo;Byeonghyeon Jeon;Wonbae Ha;Junghan Lee
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.4
    • /
    • pp.31-44
    • /
    • 2023
  • Objectives The purpose of this study is to check the research trends of pharmacopuncture treatment in nerve entrapment syndrome, identify specific techniques, identify which pharmacopuncture are used, and provide directions for future research. Methods This study was conducted based on the five steps suggested by Arksey and O'Malley. We searched five domestic databases (Research Information Sharing Service, Oriental Medicine Advanced Searching Integrated System, Korean studies Information Service System, Science ON, and KMBASE) and identified studies with key search terms like "nerve entrapment" And "pharmacopuncture" until June 23, 2023. Results Twenty-nine studies were finally selected. among them, 25 papers were non-comparative studies (86.2%). The most common disease was carpal tube syndrome (n=10). All the investigated studies were treated by injecting pharmacopuncture into the pathway of the entraped nerve. The depth of pharmacopuncture injection was mentioned only in 13 studies. As for the pharmacopuncture used, sweet bee venom was 8 studies and bee venom was 6 studies, and about half of the pharmacopuncture manufactured with Bee venom as the main component accounted for. Conclusions This study is a scoping review of the pharmacopuncture treatment for nerve entrapment, which was first conducted in Korea. The treatment is mainly performed on the path way of the entraped nerve. After that, it is necessary to study the standardization of the specific technique method of pharmacopuncture and the uniformity of evaluation criteria.

Development of Biocompatible Vascular Graft -Endothelialization of Small Vascular Graft- (생체적합성 인조혈관의 개발 -혈관내피화 인조혈관-)

  • 김형묵;이윤신
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.373-380
    • /
    • 1996
  • Prevention of thromboembolism is the most important task in the development of bioconpatible small caliber artificial vascular graft. In normal vessels, vascular endothelial cells maintain homeosatsis by secreting numerous factors. The aim of this study is to develope a method which Improves biocompatibility of small caliver polyurethane graft using endothelial cell culture technique, and ev luate the efTectiveness of extracelluar matrix for endothelization which was produced by cultured fibroblast. Methods ; Multiporous polyurethane tube of 3 mm diameter, 0.3 mm thickness was manufactured for vascular graft. Three mongrel dogs were intubated and internal jugular veins removed. Extracelluar matrix produced by cultured flbrobast which was obtained from dog's internal jugular vein were coated to the polyurethane graft. Then, endothelial cells extracted from Jugular vein were cultured and fixed on the extracelluar matrix layer of vascular graft. Endothelial cell coated vascular grafts were implanted to the carotid arteries of experimental dogs as interposed autograft. Implanted grafts were removed after 3 and 6 weeks. As a control, PTFE graft was interposed on carotid artery. These experiments demonstrated that extracelluar matrix produced by fibroblast can afford a base for endothelial cell linings of polyurethane graft. Although thrombosis were developed on autografted en othelial cell coated graft, 33% opening was noticed, and showed less adhesion to adjacent tissue layer. These findings suggest that fiboblast produced extracelluar matrix which can be used for edothelial cell lining vascular graft, and by improving the cultured endothelial cell function, there will be a new modality for reducing thrombosis on small vascular graft.

  • PDF

A Study on the Demand for Equipent Development in Nursing (간호기기 개발수요 조사연구)

  • Chang, Soon-Book;Kim, Eui-Sook;Whang, Ae-Ran;Kang, Kyu-Sook;Suh, Mi-Hae
    • The Korean Nurse
    • /
    • v.35 no.2
    • /
    • pp.71-91
    • /
    • 1996
  • The objectives of thes study were to identify the need for equipment development in nursing, and to determine the priorities for that development. The study was descriptive study done between March 2 and May 30, 1995, in which the subjects, including 421 patients, 223 family members, and 198 nurses from neurosurgery, orthopedic, rehabilitation medicine, internal medicine and intensive care units of nine general hospitals in Seoul, completed a questionnarie developed by the research team. The questionnaire consisted of 35 open and closed questions. Data was analyzed using frequencies and percentages. The results ware summarized as follows: 1) The average age of the nurses was 27.9 years, 48% of the patients were between 20 and 40 years of age, and 17% were over 60. The average lingth of experience for the nurse subjects was four years five months with 36.9%. having over five years experience. The most frequent diagnoses of patients were spinal disc(35.9%), internal medicine disease(26.0%), cerebral vascular accident(16.6%) and spinal cord injury(10%) 2) Many of the nurses(96.4%) reported deficiencies with existing equipment and 96.5% of the nurses, but only 79.8% of the patients, nurses' time. Further, 82.3% of the nurses and 75.8% of the patients felt that the development of new equipment would lead to a decrease in the cost of nursing care. 3) Nurses felt that the greatest areas of inconvenience were patient feeding(71.7%), hygiene(71.2%), caring for a patient confined to bed(70.7%), patient clothing(67.2%), mobility transfers(63.5%) and urinary elimination(52.0%). However, patients and family members listed the following as being the most inconvenient: urinary elimination(58.7%), Hygiene(50.5), feeding(48.4%), mobility transfers(47.1%) and bed care(45.2%). 4) Generally the nurses listed more inconveniences and patients and family members listed more demands for the development of equipment. These included utensils with large handles, and regulators for tube feedings; mattresses that provide for automatic position change and massage, which have patient controlled levers and a place for bed pan insertion; automatic lifts or transfer from bed to wheelchair; equipment to facilitate washing and oral hygiene as well as equipment that will allow patients with spinal cord injuries easy access to showers; a bed pan/urinal for women that is comfortable and effective from which urine can be measured and disposed of easily; disposable dressing sets and tracheostomy care sets and a convenient way of measuring changes in wound size; a safe delivery system for oxygen, a variety of mask sizes and better control of humidity, tracheal material than at present, as well as a communication system for patients with tracheostomies; clothing that will allow access to various parts of the body for treament or assessment without patients having to remove all of their clothing; and finally a system that will allow the patient to control lighting, telephones and pagers. Priority areas for equipment development reported by the nurses were, urinary elimination(58. 7%), hygiene(50.5%), feeding(48.4%), mobility transfers(47..1%), bowel elimination(40.8%). Those reported by the patients family members were feeding(71.7%), hygiene(70.0%), bedcare(70.7%), clothing(67.2%), mobility transfers(63.6%), urinary elimination(52.9%) and bowel elimination(50.5%) Altogether, nurses, patients and family members listed the following as priorities; clothing (178), bed care(144), urinary elimination(92), environment(81), hygiene(70). Further, a health professional forum listed urinary elimination, oxygen delivery, medication delivery, mobility transfers, bed care and hygiene in that order as priority areas. From this study it can be concluded that the first need is to develop equipment that will address the problems of urinary elimination. To do (l)This nurses who are interested in equipment development should organize an equipment development team to provide a forum for discussion and production of equipment for nursing.

  • PDF

Development of Artificial Pulmonary Nodule for Evaluation of Motion on Diagnostic Imaging and Radiotherapy (움직임 기반 진단 및 치료 평가를 위한 인공폐결절 개발)

  • Woo, Sang-Keun;Park, Nohwon;Park, Seungwoo;Yu, Jung Woo;Han, Suchul;Lee, Seungjun;Kim, Kyeong Min;Kang, Joo Hyun;Ji, Young Hoon;Eom, Kidong
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.76-83
    • /
    • 2013
  • Previous studies about effect of respiratory motion on diagnostic imaging and radiation therapy have been performed by monitoring external motions but these can not reflect internal organ motion well. The aim of this study was to develope the artificial pulmonary nodule able to perform non-invasive implantation to dogs in the thorax and to evaluate applicability of the model to respiratory motion studies on PET image acquisition and radiation delivery by phantom studies. Artificial pulmonary nodule was developed on the basis of 8 Fr disposable gastric feeding tube. Four anesthetized dogs underwent implantation of the models via trachea and implanted locations of the models were confirmed by fluoroscopic images. Artificial pulmonary nodule models for PET injected $^{18}F$-FDG and mounted on the respiratory motion phantom. PET images of those acquired under static, 10-rpm- and 15-rpm-longitudinal round motion status. Artificial pulmonary nodule models for radiation delivery inserted glass dosemeter and mounted on the respiratory motion phantom. Radiation delivery was performed at 1 Gy under static, 10-rpm- and 15-rpm-longitudinal round motion status. Fluoroscpic images showed that all models implanted in the proximal caudal bronchiole and location of models changed as respiratory cycle. Artificial pulmonary nodule model showed motion artifact as respiratory motion on PET images. SNR of respiratory gated images was 7.21. which was decreased when compared with that of reference images 10.15. However, counts of respiratory images on profiles showed similar pattern with those of reference images when compared with those of static images, and it is assured that reconstruction of images using by respiratory gating improved image quality. Delivery dose to glass dosemeter inserted in the models were same under static and 10-rpm-longitudinal motion status with 0.91 Gy, but dose delivered under 15-rpm-longitudinal motion status was decreased with 0.90 Gy. Mild decrease of delivered radiation dose confirmed by electrometer. The model implanted in the proximal caudal bronchiole with high feasibility and reflected pulmonary internal motion on fluoroscopic images. Motion artifact could show on PET images and respiratory motion resulted in mild blurring during radiation delivery. So, the artificial pulmonary nodule model will be useful tools for study about evaluation of motion on diagnostic imaging and radiation therapy using laboratory animals.