• Title/Summary/Keyword: truss connection

Search Result 51, Processing Time 0.019 seconds

Several Issues Closely Related to Construction in the Structural Design of Wuhan Center

  • Jian, Zhou
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.3
    • /
    • pp.189-196
    • /
    • 2022
  • The practical difficulties of construction will impose many restrictions on the structural design, and the construction method can also provide unexpected ideas for solving design problems. Through the discussion of three issues closely related to construction in the structural design of Wuhan Center, this paper illustrates the importance of in-depth consideration of the construction situations in the structural design stage. The topics of "Connection between Embedded Steel Plates in Steel Plate Composite Shear Wall" and "Connection Joint between Outrigger Truss and Core Wall" are about how to facilitate on-site construction by simplifying and optimizing detail design. The topic of "Adjusting Internal Force Distribution by Optimizing Construction Sequence" is about how to make the construction process a tool for structural design.

The elastic bucking strength of axially compressed tubular member with through-gusset connection (관통한 가셋트판이 부착된 압축 강관 부재의 탄성좌굴내력)

  • Kim, Woo-Bum;Lim, Ji-Youn
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.2
    • /
    • pp.133-141
    • /
    • 2001
  • A tubular member holding an axially through-gusset connection is often used to transmit axial compression in a steel truss structures. The elastic buckling loads of the member is affected by the stiffness ratio($\beta$) and the length ratio(G) because of two elements with different properties. In current code, however, the strength is evaluated with an effective length factor k=0.9 without considering the above effect. Therefore this study analyzed a theoretical mechanism based on the elasticity theory and performed a finite element analysis to investigate the influence parameters on the elastic buckling strength of axially loaded member.

  • PDF

Design and Implementation of Parametric Modeler for Retractable Roof Three-Dimensional Truss (개폐식 지붕 입체트러스를 위한 파라메트릭 모델러의 설계와 구현)

  • Jeong, Jin-Young;Joung, Bo-Ra;Kim, Chee-Kyeong;Lee, Si Eun;Kim, Si-Uk
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • The purpose of this study is to implement modeling by applying the parametric technique to the atypical trusses of rigid retractable large space structures. The retractable large space structure requires a lot of time and skill in modeling nonlinear shapes or generating, interpreting, and reviewing many models by alternative. To solve these problems, we introduce firstly parametric modeling tool, secondly, we analyze the connection of atypical three-dimensional trusses of a rigid retractable large-space structure, and finally model it as parametric components of the developed trusses. Therefore, it is a future study to make effective modeling of the openable roof by developing the components that can realize the modeling of the truss classified by the opening and closing method, respectively.

An Experimental Study on Structural Behavior of Half Slab Reinforced by Truss Mesh (트러서메쉬 보강 하프 슬래브의 구조적 거동에 관한 실험적 연구)

  • Ko, Man-Young;Kim, Yong-Boo;Park, Hyun-Soo;Chung, Lan
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.4
    • /
    • pp.119-128
    • /
    • 1995
  • This paper summarizes experimental results for studying feasibility and structural behavior of' a half slab which is getting popularity in recent building construction in favour of the savings in manpower, coats, and construction period. 17 specimens were tested to investigate and analyze the flexural strength of precast concrete slab, half slab, and half slab-wall joint. The primary variables of the testing program were: thickness of precast concrete slab, truss mesh shape, and type of loadings. Test results show that the flexural strength of precast concrete slab in reverse loading is lower than the design strength, but the flexural strength of precast concrete slab, half slab and half slab-wall joint in direct loading is higher than the design srength. No horizontal cracks were found in the connection between insitu concrete and precast concrete slab. The flexural strength of half slab and half slab-wall joint was the same as that of reinforced concrete members. This study concludes that there will not be any structural problem in using a half slab reinforced by truss mesh if props spacing of 2.0m-2.5m, cleanness, and rough finishing between precast concrete and insitu concrete slab are kept.

An Experimental Study on the Prediction of Yield Load Using Ring Analysis Method in Circular Tubular X-Type Cross Sections (링해석법에 의한 X형 강관 격점부의 항복하중 예측에 관한 실험적 연구)

  • Park, Il Min;Na, Seon Hong
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.1 s.38
    • /
    • pp.43-54
    • /
    • 1999
  • The divergence connection between steel circular tubes is widely used in such structures as factory facilities, steel circular hollow section truss, and off-shore tower. Steel circular hollow section (SCHS) have close section, and it makes their per-unit production expense higher than open sectioned products like L-shape, H-shape steels, but the sectional resistance of SCHS against vertical compression and torsion is very high. Despite the structural merits of SCHS, however, many engineers dislike to use them in their design because of uncertainty regarding the stress distribution and deformation behavior at their connections. Therefore, this thesis dealt with X-type connections, the most common forms of connection, and studied their load-deformation relationship. It observed how to show the load-deformation relationship at steel circular tube connections according to the diameter-thickness ratio (D/T) of the chord and diameter of branch-diameter of chord ratio (d/D) and suggested prediction yield load using by ring analysis method.

  • PDF

Flexural Capacity of the Profiled Steel Composite Beams with Truss Deck Plate (트러스 데크를 사용한 강판성형 합성보의 휨성능 평가)

  • Heo, Byung Wook;Kwak, Myong Keun;Bae, Kyu Woong;Jung, Sang Min;Kang, Suk Kuy
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.4
    • /
    • pp.413-423
    • /
    • 2007
  • Slimfloor composite-beam systems could considerably reduce the story height of a building if the steel beam would be installed deep into the concrete floor slab. However, as the depth of the steel beam's installation is limited, it cannot cope with the various demands of building systems. To address this problem, a profiled steel beam section that can control the depth of the steel beam's and slabs' installation was developed in this study. Presented herein are the results of an experiment that was conducted focusing on the flexural behavior of the partially connected composite beams with profiled steel beams encased in composite concrete slabs. Five full-scale specimens with different slab types, with or without shear connection and reinforcement bars, were constructed and tested in this study. As a result, the shear bond stress without an additional shear connection was found to be $0.20{\sim}0.76N/mm^2$due to the inherent mechanical and chemical bond stress.

Predicting the failure modes of monotonically loaded reinforced concrete exterior beam-column joints

  • Bakir, Pelin G.;Boduroglu, Hasan M.
    • Structural Engineering and Mechanics
    • /
    • v.14 no.3
    • /
    • pp.307-330
    • /
    • 2002
  • This study aims at postulating a simple methodology for predicting the failure modes of monotonically loaded reinforced concrete beam-column joints. All the factors that affect the failure modes of joints are discussed in detail using an experimental database of monotonically loaded exterior beam-column joints. The relative contributions of the strut and truss mechanisms to joint shear strength are determined based on the test results. A simple design equation for the beam longitudinal reinforcement ratio for joints with low, medium and high amount of stirrups is developed. The factors influencing the failure modes of monotonically loaded exterior beam-column joints are investigated in detail. Design charts that predict the failure modes of exterior beam-column connections both with and without stirrups are developed. Experimental data are compared with the design charts. The results show that the simple methodology gives very accurate predictions of the failure modes.

Damage Analysis of Reinforced Concrete Columns under Cyclic Loading

  • Lee, Jee-Ho
    • KCI Concrete Journal
    • /
    • v.13 no.2
    • /
    • pp.67-74
    • /
    • 2001
  • In this study, a numerical model for the simulation of reinforced concrete columns subject to cyclic loading is presented. The model consists of three separate models representing concrete, reinforcing steel bars and bond-slip between a reinforcing bar and ambient concrete. The concrete model is represented by the plane stress plastic-damage model and quadrilateral finite elements. The nonlinear steel bar model embedded in truss elements is used for longitudinal and transverse reinforcing bars. Bond-slip mechanism between a reinforcing bar and ambient concrete is discretized using connection elements in which the hysteretic bond-slip link model defines the bond stress and slip displacement relation. The three models are connected in finite element mesh to represent a reinforced concrete structure. From the numerical simulation, it is shown that the proposed model effectively and realistically represents the overall cyclic behavior of a reinforced concrete column. The present plastic-damage concrete model is observed to work appropriately with the steel bar and bond-slip link models in representing the complicated localization behavior.

  • PDF

Shear strength of connections between open and closed steel-concrete composite sandwich structures

  • Kim, Woo-Bum;Choi, Byong Jeong
    • Steel and Composite Structures
    • /
    • v.11 no.2
    • /
    • pp.169-181
    • /
    • 2011
  • The behavior of connections between open sandwich slabs and double steel skin composite walls in steel plate-concrete(SC) structure is investigated by a series of experimental programs to identify the roles of components in the transfer of forces. Such connections are supposed to transfer shear by the action of friction on the interface between the steel surface and the concrete surface, as well as the shear resistance of the bottom steel plate attached to the wall. Experimental observation showed that shear transfer in slabs subjected to shear in short spans is explained by direct force transfer via diagonal struts and indirect force transfer via truss actions. Shear resistance at the interface is enhanced by the shear capacity of the shear plate as well as friction caused by the compressive force along the wall plate. Shear friction resistance along the wall plate was deduced from experimental observation. Finally, the appropriate design strength of the connection is proposed for a practical design purpose.

Fatigue Crack Propagation in Coped Stringers of Steel Railway Bridges (강철도교 바닥판 세로보 절취부의 피로균열 진전해석)

  • Choi, Dong-Ho;An, Woo-Sung;Choi, Hang-Yong
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.557-562
    • /
    • 2003
  • The responses of the floor system of a railway bridge are investigated for fatigue life prediction of damaged members using fracture mechanics approach. Numerical analysis of the structure is performed in order to see the influence of track-structure interaction and continuity of the truss connection on the response of the bridge members. Fatigue crack growth analysis is carried through equivalent stress obtained from time-history analysis. The results of time-history analysis agree with measured responses. The fatigue propagation life increases as the curvature in the coped stringer increases.

  • PDF