• 제목/요약/키워드: tree initiation voltage

검색결과 15건 처리시간 0.02초

유기물이 첨가된 저밀도 폴리에칠렌에서 예비과전에 따른 트리잉 열화 (The Treeing Deterioration with Prestressed D.C Voltage in Low Density Polyethylen Mixed with Organic Compounds)

  • 채홍인;양계준;임기조
    • 한국안전학회지
    • /
    • 제6권2호
    • /
    • pp.15-20
    • /
    • 1991
  • In this paper, we have investigated the effect of organic additives and prestressed D C. voltage on the impulse tree initiation in low density polyethylene. The five klnds of organic compounds was selected for the purpose of inhibiting tree initiation and 10 wt % of each additive was mixed in low density polyethylene. The positive or negative impulse voltage was applied after prestressed D.C. voltage was applied in order to investigate the effect of the space charge influenced on tree initiation. The lengths of tree initiation in case of belng same polarity between prestressed D.C. voltage and impulse voltage were longer than those in case of being different polarity between prestressed D.C. voltage and impulse voltage. When the polarity prestressed D.C. voltage was the different plarity of impulse voltage, the length of tree initiation increased with increasing the prestressed D.C. voltage and decreasing the rest time Among the organic additives used in this paper, the m-cresol can be shown to be the most effective inhibiter to tree initiation.

  • PDF

저밀도 폴리에틸렌에 있어서 트리잉 진전에 따른 ${\phi}-a$ 분포양상의 시간적 변화에 관한 연구 (A Study on Time Variation of ${\phi}-a$ Distribution Patterns due to Treeing Propagation in low Density Polyethylene)

  • 강태오;백관현;김명호;김경환;박재준;김재환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.427-430
    • /
    • 1991
  • In this study, in order to observe treeing of prebreakdown phenomena, time variation of acoustic emission properties due to initiation and propagation of tree in LDPE was investigated under AC voltage. The experimental results were as following, pulse number and average amplitude of AE were increased along with near breakdown rather than tree initiation, also, according to increasing of applied voltage, tree propagation was blunted, while pulse number and average amplitude of AE was promoted. In each applied voltage, ${\phi}-a$ distributions during propagation of tree were changed to special patterns, skewness S and kurtosis K reflected well time variation of ${\phi}-a$ distribution patterns. It is thought that initiation and propagation state of tree can be easily monitored, so long as time variation of pulse number and average amplitude of AE, skewness Sand kurtosis K of ${\phi}-a$ distribution are always monitored.

  • PDF

방향족 화합물이 첨가된 저밀도 폴리에틸렌의 Treeing 특성 (Treeing characteristics in LDPE Added with Aromatic Compounds)

  • 신태수;박영국;박철현;장동욱;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1481-1483
    • /
    • 1998
  • we have investigated the effect of aromatic compounds and tree inception and growth in low density polyethylene, for AC voltage and Impulse voltage. 2kinds of aromatic compounds are selected. Each additive (m-cresol, aniline) was mixed in low density polyethylene. For AC voltage, 10wt% $\sim$ 15wt% m-cresol can be shown to be the effective inhibitor to tree initiation. But, For Impulse voltage, 10wt% $\sim$ 15wt% aniline is effective inhibitor to tree initiation.

  • PDF

화상계측에 의한 지중 전력케이블의 수트리 열화에 관한 연구 (A Study on Water Tree Degradation Using Image Measurement in Underground Power Cables)

  • 김덕근;임장섭;이진
    • 한국전기전자재료학회논문지
    • /
    • 제13권12호
    • /
    • pp.1063-1068
    • /
    • 2000
  • Water treeing in underground distribution power cable is not easy to observe by nondestructive method and it has very complex patterns. This study describes the principles and practices of a continuous observation of initiation and growth of tree in polymeric insulation material using an image measurement technique. Using this technique we could observe water tree and the growing process of electrical tree due to the water tree and the growing process of electrical tree due to the water tree. All of these growing process is analyzed quantitatively by image measurement program composed of borland c++. We fabricated the thin film type specimen to observe water tree easier and also the needle electrode was prepared by etching method using electrolytes. Initiation and the growth of three was observed somewhat different depending on the applied voltage and the water electrode. AgNO$_3$solution electrode accelerates the initiation and the growth of water tree, compared to those of distilled water electrode. The water and the electrical tree occurred by water tree has discontinuous growth characteristic.

  • PDF

에폭시수지의 고전압 전원주파수 변화에 따른 장시간 전기적 트리잉 열화 특성연구 (A Study on Long-time Electrical Treeing Deterioration Properties According to High Frequency Voltage of Epoxy Resin)

  • 박재준
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1571-1577
    • /
    • 2013
  • Electrical tree structure is one of the most important influencing factors for electrical treeing characteristics in polymers. In this paper, we focused on the structure characteristics of electrical treeing in epoxy resins (original) insulation under different high-frequency voltages (60, 500, 1000Hz). Effects of voltage frequency on the ac electrical treeing phenomena in an epoxy resins were carried out in needle-plate electrode arrangement. To measure the treeing initiation and propagation, and the breakdown rate, constant AC of 10 kV with three different voltage frequencies (60, 500 and 1,000 Hz) was applied to the specimen in needle-plate electrode specimen at $30^{\circ}C$ of insulating oil bath. At 60 Hz, the treeing initiation time was 360 min and the propagation rate was $6.85{\times}10^{-4}mm/min$, and the morphology was dense branch type. As the voltage frequency increased, the treeing initiation time decreased and the propagation rate increased. At 1,000 Hz, the treeing initiation time was 0 min and the propagation rate was $7.81{\times}10^{-2}mm/min$, and the morphology was dense bush type.

트리잉 열화에 따른 $\phi$-AE 분포특성에 관한 연구 (A Study on $\phi$-AE Distribution Patterns Characteristics due to Treeing Deterioration)

  • 박재준;강태오;김재환
    • 대한전기학회논문지
    • /
    • 제41권9호
    • /
    • pp.1060-1070
    • /
    • 1992
  • In this paper, characteristics of Acoustic Emission in Low Density Polyethylene were studied from tree initiation to breakdown under long-term inhomogeneous alternative electrical field. The voltage levels used were 9, 11 and 14[kV]. Especially, a newly developed automatic measuring system was used to measure time variations of AE average amplitude, AE pulse number, AE pulse distribution patterns due to polarities. The patterns wer specially the variated patterns, when tree propagated. Also, parameters for dielectric breakdown prediction, which were suggested by Okamoto, were calculated. The result was analysed by tree shapes and partial discharge activities in tree due to tree initiation and propagation.

  • PDF

국산유기절연재료의 Treeing현상 (Treeing Phenomena in the Home-made Solid Organic Insulating Materials)

  • 성영권;이헌용;이계호;유기한
    • 전기의세계
    • /
    • 제26권2호
    • /
    • pp.57-65
    • /
    • 1977
  • In roder to investigate the influence of treeing on electric breakdown of solid organic insulator the initiation and growing mechanism of tree itself, and the correlation between corona discharge and treeing phenomena in solid orgainc insulating materials, several experiments were carried out by means of needle test on polymethyl-methacrylate. The obtained results showed that the existence of voids in specimen had important effects on initiation voltage of trees and, when the direct voltage was applied, the initiation voltage of trees increased by space charge effect. And also the stagnation phenomena due to the transfer of vacancy cluster or polymekr cage in specimen might beconsidered in process of growth of trees, and corona discharge seemed to be the pre-phenomena of treeing because trees were normally initiated by internal discharge in voids.

  • PDF

송전 XLPE 케이블 절연층을 이용한 전기트리 형성과 부분방전 양상의 상관관계 (A study on the correlation between the PD pattern and the formation of electrical trees by use of XLPE insulation for the underground power transmission cable)

  • 이전선;김정태;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2051-2053
    • /
    • 1999
  • In this work, PD patterns and electrical trees are observed by use of the XLPE cable insulation. and the tree initiation voltage related to the contamination are also measured in order to calculate the electric stress necessary for the design of cable insulation. Throughout these works, correlation between the PD pattern and the shape of electrical tree has been observed that there may exist three distinct pattern of PD dependence on the stage of tree propagation, Such correlation could bring a basic information in connection with the partial discharge of cable system. It was also found that the electrical stress necessary for the initiation of electrical tree was measured to the 290kV/mm for the 154kV XLPE cables manufactured in KOREA.

  • PDF

도전체와 절연체 계면에서의 전기트링 현상 (Electrical Treeing Phenomena at the Interface of Conductor and Insulator)

  • 조영신;심미자;김상욱
    • 한국표면공학회지
    • /
    • 제28권4호
    • /
    • pp.236-242
    • /
    • 1995
  • This paper describes a study of electrical tree growth in DGEBA/MDA/SN system subjected to ac high electric field. The dielectric breakdown process, which consists of tree initiation, tree propagation and the complete puncture of the system was investigated. Dielectric breakdown always initiated from the needle tip where the electric field reinforcement is the highest. Higher temperature and voltage accelerated the tree growth and reduced the time to breakdown.

  • PDF

화상처리에 의한 XLPE의 트리열화관측 (Tree aging observation of XLPE by image processing)

  • 임장섭;김태성;길촌승
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권5호
    • /
    • pp.551-557
    • /
    • 1995
  • For the observation of treeing, a visual measurement with an optical microscope has been used to explain breakdown mechanism in high-voltage systems. The conventional directed visual method of tree aging observation is difficult to measure in short time processing, and it is impossible to analyze on tree degradation area, progressed direction, tree pattern, etc. By using an image processing technique, the tree features which appear immediately after the tree initiation as well as changes in the configuration of the tree can be easily measured and observed than using the conventional visual methods. In this paper, we have developed a tree observating system by using image processing for tree growth, degradation area and other treeing progress. As an experimental result, it can be concluded that the image processing method is a more effective alternative than directed visual observation method. As a matter of fact, it is possible to record the image of tree propagation immediately after its first appearance and explain the characteristics of tree growth froth the computer processing image.

  • PDF