• Title/Summary/Keyword: treatment device

Search Result 1,531, Processing Time 0.032 seconds

Development of the Spent Fuel Rod Cutting Device by Cutter Blade Method (Cutter blade 방식에 의한 사용후핵연료봉 절단 장치 개발)

  • 정재후;윤지섭;홍동회;김영환;김도우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.393-396
    • /
    • 2000
  • Spent fuel rod cutting device should cut a spent fuel rod to an optimal size in order to fast decladding operation. In this paper, for developing spent fuel rod cutting device with cutter blade, rod properties such as dimension and material of zircaloy tube and fuel pellet are investigated at first and then, various methods of existing cutting devices used commercially are investigated and their performance are analyzed and compared. This device is designed to be operated automatically via remote control system considering later use in Hot-Cell (radioactive area) and the mdularization in the structure of this device makes maintenance easy. SUS and Zircaloy-4 are selected as cut material used in the test of spent fuel rod cutting device by cutter blade. In order for constructing the high durable cutter blade, various materials are analyzed in terms of quality, shape, characteristic, and heat treatment, etc. and from these results, spent fuel rod cutting device is designed and manufactured based on the considerations of durability, round shape sustainability of rod cross-section, debris generation, and fire risk, etc.

  • PDF

Development of u-Lifecare Monitoring System Device (u-라이프케어 모니터링 시스템 단말기 개발)

  • Choi, Dong-Oun;Kang, Yun-Jeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.7
    • /
    • pp.1533-1540
    • /
    • 2012
  • u-Life care device collect body bio formation, and classify and store them in exercise patterns. Afterwards, the devices send the data through bluetooth wireless communication to the smart phones which set Google Android operation system at regular intervals. The information is checked out through application. u-Life care device calculates calories spent a day after monitoring activity quantity with 3-axis acceleration sensor. The device judges the status of health through body data mining and consults tailored exercise treatment. When sending body data, the device sends them in smart phone through Blue Tooth wireless communication at once. So, as a strong point, the device doesn't need mobile gateway or home gateway used for sending to web server information sensed from exercise life care products.

A CASE REPORT OF COMPLICATIONS DURING MANDIBULAR TRANSVERSE SYMPHYSIS WIDENING (하악 이부 확장술 시 나타나는 합병증의 치험례)

  • Suh, Chung-Whan;Kang, Kyung-Hwa;Choi, Moon-Gi
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.480-488
    • /
    • 2008
  • Orthodontists often treat cases which are difficult to treat with conventional orthodontics. In such cases, it could be treated with surgical procedures with the help of an oral surgeon. Especially, transverse deficiency of the mandible can be corrected by widening the transverse width of mandibular symphysis, using distraction osteogenesis. Transverse widening of mandibular sympysis is known as a safe treatment but still complications could occur during the treatment. We are reporting some complications of cases that mandibular symphysis transverse widening were applied. Some cases showed complications because of the inappropriate osteotomy line. Since straight vertical osteotomy line was inclined to the left, only the left bony segment was likely to expand. According to bio-mechanical considerations, it will be better to perform a step osteotomy, cutting the eccentric area of the alveolar crest and the centric area of the basal symphyseal area. Complications could also occur by the failure of the distraction device. The tooth borne distraction device was attached on the lingual side of the tooth with composite resin. During the distraction period, it was impossible to obtain appropriate distraction speed and rhythm because of frequent fall off of the distraction device. Therefore, distraction device should be attached firmly with orthodontic band or bone screw, etc. Tooth mobility increasement could also occur as a complication. 'Walking teeth phenomenon' was observed during the distraction period, showing severe teeth mobility and pain during mastication. These symptoms fade out during the consolidation period. Since the patient could feel insecure and uncomfortable, it should be notified to the patient before the procedure. Finally, alveolar crestal bone loss could occur. Alveolar crestal bone loss occurred because of lack of distraction device firmness and teeth trauma caused by lower lip biting habit. Therefore, adequate firmness of the distraction device and habit control will be needed.

Root surface roughness following mechanical instrumentation in vivo and in vitro SEM study (기구조작후 치근표면의 조도에 관한 연구; 주사전자현미경적 in vivo 및 in vitro 연구)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.4
    • /
    • pp.809-822
    • /
    • 1998
  • Adequate root preparation in the treatment of periodontal disease often involves mechanical instrumentation to remove plaque, calculus perhaps contaminated cementum. Although meticulous scaling and root planing may remove some cementum, the use of aggressive root planing to remove cementum does not appear warranted. So ultrasonic device and rotary instrument appear to be replacing hand instrument. But it is not clear those instruments make smooth root surface as hand instrument. The roghness of the root surface were evaluate with SEM following instrumentation with Gracey curette, Perio Clean and piezo ultrasonic device(Setlec) with various tip. 20 extracted teeth were used in vitro experiment, and 9 teeth of a patient destined for extraction for periodontal reasons were utilized in vivo experiment. It was demonstrated that hand curette created the smoothest surface, while diamond tip tended to roughen the root surface. But the hand curette, Perio Clean, and piezo ultasonic device with scaler tip tend to remove cementum completely. Piezo ultrasonic device with curette-like tip made the desirable smooth surface with partial removal of cementum.

  • PDF

Surgical Extraction of an Embolized Atrial Septal Defect Occluder Device into Pulmonary Artery after Percutaneous Closure

  • Yolcu, Mustafa;Kaygin, Mehmet Ali;Ipek, Emrah;Ulusoy, Fatih Rifat;Erkut, Bilgehan
    • Journal of Chest Surgery
    • /
    • v.46 no.2
    • /
    • pp.135-137
    • /
    • 2013
  • An atrial septal defect is the most common type of congenital heart disease among adults. Surgical repair or percutaneous closure of the defect is the treatment options. Even though percutaneous closure seems to be less risky than surgical repair, it may result in fatal complications like device embolism, cardiac perforation and tamponade. Herein we report a case of the embolism of a device into the pulmonary artery after one hour of percutaneous closure in which the embolized device was surgically removed and the defect was closed with a pericardial patch.

In-situ rf treatment of multiwall carbon nanotube with various post techniques for enhanced field emission

  • Ahn, Kyoung-Soo;Kim, Jun-Sik;Kim, Ji-Hoon;Kim, Chae-Ok;Hong, Jin-Pyo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.859-862
    • /
    • 2003
  • Well-aligned multiwall carbon nanotubes (MWCNTs) were prepared at low temperature of 400 $^{\circ}C$ by utilizing a radio frequency plasma-enhanced chemical vapor deposition (rf-PECVD) system. The MWCNTs were treated by an external rf plasma source and an ultra-violet laser in order to modify structural defect of carbon nanotube and to ablate possible contamination on carbon nanotube surface. Structural properties of carbon nanotubes were investigated by using a scanning electron microscopy (SEM), Raman spectroscopy, Fourier transformer Infrared spectroscopy (FTIR) and transmission electron microscope (TEM). In addition, the emission properties of the MWNTs were measured for the application of field emission display (FED) in near future. Various post treatments were found to improve the field emission property of carbon nanotubes.

  • PDF

Effect of Patients with Genu Varum on Device for Correcting Bowleg: 4 Cases Report (고관절 내회전 변형 교정장치를 통한 내반슬 환자의 호전된 증례보고 4례)

  • Cho, Woong-Hee;Kim, Hyung-Gil;Lee, Dong-Eun;Park, Won-Hyung;Cha, Yun-Yeop
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.3
    • /
    • pp.131-137
    • /
    • 2010
  • This study was designed to evaluate clinical effects of device for correcting bowleg and Chuna to patients with genu varum. The clinical study was carried out 4 cases with genu varum, who had been treated from April, 2009 to May, 2010 in the department of oriental rehabilitation medicine, Sang-ji university oriental medical hospital. After treating device for correcting bowleg and Chuna, we find out that genu varum was improved after treatment. So these results suggest that device for correcting bowleg and Chuna was effective to patients with genu varum.

Investigation of Oxygen Functional Group Movement in Graphene Oxide Devices (그래핀 산화물 소자에서의 산소 작용기 이동 연구)

  • Eun Hee Kee;Mohd Musaib Haidari;Ji Hoon Jeon;Jin Sik Choi;Bae Ho Park
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.100-104
    • /
    • 2023
  • In this study, a device was fabricated to check the possibility of a memory device by controlling the oxygen functional groups in graphene oxide formed with a 45-second exposure time. We discovered that graphene oxide can be formed using the ultraviolet (UV) light treatment method with different exposure times. Moreover, Raman spectroscopy measurement revealed that the oxygen functional groups can be moved by controlling the voltage. We further studied the change in the local graphene oxide region, which was found to be related to the modulation of the electrical properties of the device. Therefore, the fabricated graphene oxide device can be used as a wettability switching membrane and graphene-based ion transport device.

Effect of heat treatment in $HfO_2$ as charge trap with engineered tunnel barrier for nonvolatile memory (비휘발성 메모리 적용을 위한 $SiO_2/Si_3N_4/SiO_2$ 다층 유전막과 $HfO_2$ 전하저장층 구조에서의 열처리 효과)

  • Park, Goon-Ho;Kim, Kwan-Su;Jung, Myung-Ho;Jung, Jong-Wan;Chung, Hong-Bay;Cho, Won-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.24-25
    • /
    • 2008
  • The effect of heat treatment in $HfO_2$ as charge trap with $SiO_2/Si_3N_4/SiO_2$ as tunnel oxide layer in capacitors has been investigated. Rapid thermal annealing (RTA) were carried out at the temperature range of 600 - $900^{\circ}C$. It is found that all devices carried out heat treatment have large threshold voltage shift Especially, device performed heat treatment at $900^{\circ}C$ has been confirmed the largest memory window. Also, Threshold voltage shift of device used conventional $SiO_2$ as tunnel oxide layer was smaller than that with $SiO_2/Si_3N_4/SiO_2$.

  • PDF

Design of In-situ Self-diagnosable Smart Controller for Integrated Algae Monitoring System

  • Lee, Sung Hwa;Mariappan, Vinayagam;Won, Dong Chan;Shin, Jaekwon;Yang, Seungyoun
    • International Journal of Advanced Culture Technology
    • /
    • v.5 no.1
    • /
    • pp.64-69
    • /
    • 2017
  • The rapid growth of algae occurs can induce the algae bloom when nutrients are supplied from anthropogenic sources such as fertilizer, animal waste or sewage in runoff the water currents or upwelling naturally. The algae blooms creates the human health problem in the environment as well as in the water resource managers including hypoxic dead zones and harmful toxins and pose challenges to water treatment systems. The algal blooms in the source water in water treatment systems affects the drinking water taste & odor while clogging or damaging filtration systems and putting a strain on the systems designed to remove algal toxins from the source water. This paper propose the emerging In-Situ self-diagnosable smart algae sensing device with wireless connectivity for smart remote monitoring and control. In this research, we developed the In-Site Algae diagnosable sensing device with wireless sensor network (WSN) connectivity with Optical Biological Sensor and environmental sensor to monitor the water treatment systems. The proposed system emulated in real-time on the water treatment plant and functional evaluation parameters are presented as part of the conceptual proof to the proposed research.