• Title/Summary/Keyword: treatment device

Search Result 1,531, Processing Time 0.029 seconds

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF

A comparison between the modified Brostrom procedure using single and double suture anchor for chronic lateral ankle instability (발목관절 외측 불안정성에서 단일 봉합나사와 이중 봉합나사를 이용한 변형 Brostrom 술식간의 임상결과 비교)

  • Shon, Hyun-Chul;Cho, Byung-Ki;Kim, Yong-Min;Kim, Dong-Soo;Choi, Eui-Sung;Park, Kyoung-Jin;Park, Ji-Kang
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.69-77
    • /
    • 2011
  • Purpose: This study was retrospectively performed to compare the clinical outcomes of modified Brostrom procedures using the single suture anchor and the double suture anchor for chronic lateral ankle instability. Materials and Methods: Thirty-seven patients were followed up for more than 1 year after the modified Brostrom procedures using suture anchor. Single surgeon treated seventeen cases with single suture anchor and 20 cases with double suture anchor. The clinical evaluation was performed according to the Karlsson scale and Sefton grading system. Radiologic measurement of the talar tilt and anterior talar translation was performed through anterior and varus stress radiographs using Telos device. Results: The Karlsson scale had improved significantly from preoperative average of 45.2 points to 89.4 points in single suture anchor group, and from 46.4 points to 90.5 points in double suture anchor group. According to the Sefton grading system, 15 cases (88.2%) in single suture anchor group and 18 cases (90%) in double suture anchor group achieved satisfactory results. The talar tilt angle and anterior talar translation had improved significantly from preoperative average of $13.6^{\circ}$ and 8.6 mm to $5.4^{\circ}$ and 4.1 mm in single suture anchor group, from $14.1^{\circ}$ and 8.4mm to $3.9^{\circ}$ and 4 mm in double suture anchor group. Double suture anchor technique was significantly superior in postoperative talar tilt. Conclusion: Single and double suture anchor techniques produced similar clinical and functional outcomes except for talar tilt, which was significantly superior in double suture anchor group. Both modified Brostrom procedures using the single and double suture anchor appear to be effective treatment methods for chronic lateral ankle instability. Further evaluation of clinical outcomes and biomechanical studies in athletes are needed.

  • PDF

The effects of desensitizing agents, bonding resin and tooth brushing on dentin permeability, in vitro (지각과민 처치제 후 접착레진 처리가 상아질 투과도에 미치는 영향)

  • Hong, Seung-Woo;Park, No-Je;Park, Young-Bum;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.165-176
    • /
    • 2014
  • Purpose: The effects of desensitizing agent are often for a short duration. One of the reasons is believed to be wear of desensitizing agent by tooth brushing. To reduce the wear and make the duration longer, dental bonding resin was applied and the changes of dentin permeability after toothbrushing were measured. Materials and methods: Extracted teeth free from caries were chosen. Coronal dentin discs with thickness of 1 mm were prepared. Using the split chamber device developed by Pashely, hydraulic conductance and scanning electron microscope images (SEM) were compared and contrasted before and immediately after the application of desensitizing agent and bonding resin and then after equivalent tooth brushing of 1 week, 2 weeks, and 6 weeks. Four commercially available desensitizing agents were used in this study; they were All-Bond 2, Seal & Protect, Gluma, and MS Coat. And Dentin/Enamel Bonding resin (Bisco Inc.) was used. The results of this study are as follows. Results: On all specimens, the hydraulic conductance decreased after the application of tooth desensitizing agent and bonding resin. Compared with the specimens treated only with desensitizer, the specimens treated with All-Bond 2, Gluma, MS Coat and plus D/E bonding resin had a little increase in hydraulic conductance after 1, 2 and 6-week tooth brushing. In case of Seal & Protect, the specimens showed the same result only after 6-week tooth brushing. On examination of SEM, the dentinal tubule diameter had decreased after treatment of desensitizing agents and bonding resin. And the specimens treated with All-Bond2, Seal&Protect, Gluma, MS Coat and plus D/E bonding resin had an significant decrease in diameter of dentinal tubule after 6-week tooth brushing. Conclusion: According to the results of this study, it is effective to use bonding resin after application of desensitizer in reducing the wear by tooth brushing and making the duration longer. In this study, just 6-week tooth brushing was performed, and it is not enough to regard it as a long-term data. So further study is needed and more perfect method for treating dentin hypersensitivity should be developed.

Evaluation of the Clinical Usefulness of the Xeniss Rapid TB kit for the Diagnosis of Tuberculosis (결핵진단에서 Xeniss Rapid TB kit의 임상적 유용성)

  • Park, Seung-Kyu;Lee, Woo-Chul;Hwang, Soo-Hee;Kwon, Eun-Si;Lee, Hung-Soon;Lee, Duk-Hyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.389-400
    • /
    • 2002
  • Background : The rapid diagnostic tests for tuberculosis are needed to facilitate early treatment of tuberculosis and prevention of Mycobacterium tuberculosis transmission. The Xeniss Rapid TB kit is a rapid, card-based immunochromatographic test for the detection of antibodies directed against M. tuberculosis antigens including antigen 5(38-kDa antigen). The objective of this study was to evaluate the performance of the Xeniss Rapid TB kit for the diagnosis of active tuberculosis with serums from patients, asymptomatic healthy and close contact controls. Methods : 188 patients with active tuberculosis were tested; 177 with pulmonary tuberculosis(18 with combined pleurisy), and 11 with extrapulmonary tuberculosis. The control groups were composed of 82 close contacts and 57 healthy adults. Study subject were drawn from one national tuberculosis hospital for patients and close contacts, and another private hospital for healthy adults in Masan city, Korea. The Xeniss Rapid TB kit(Xeniss Life Science Co., Ltd., Seoul, Korea) was evaluated by using serum samples according to the instructions of the manufacturer by an investigator masked to the clinical and microbiological status of the study subjects. Results : The diagnostic sensitivity of the Xeniss Rapid TB kit was 73.9% in patients and specificities were 73.2% and 93.0% in close contact and healthy adults respectively. The positive predictive value in patients was 84.2% and the negative predictive value in controls was 85.8%. Conclusion : This study shows that the Xeniss Rapid TB test is a simple and fast method to diagnose active TB. The results of the sensitivity and specificites suggest that serodiagnosis using this point of care testing(POCT) device would be valuable and advantageous for screening tuberculosis in the clinical field.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Removal of As(III) in Contaminated Groundwater Using Iron and Manganese Oxide-Coated Materials (철/망간 산화물 피복제를 이용한 오염지하수에서의 As(III)제거)

  • Kim Ju-Yong;Choi Yoon-Hyeong;Kim Kyoung-Woong;Ahn Joo Sung;Kim Dong Wook
    • Economic and Environmental Geology
    • /
    • v.38 no.5 s.174
    • /
    • pp.571-577
    • /
    • 2005
  • Permeable reactive barrier using iron oxide coated sand is one of effective technologies for As(V) contaminated groundwater. However, this method is restricted to As(III), because As(III) species tends to be more weakly bound to adsorbent. In order to overcome the limitation of iron oxide coated sand application to As(III) contaminated groundwater, manganese oxide materials as promoter of As(III) removal were combined to the conventional technology in this study. For combined use of iron oxide coated sand and manganese oxide coated sand, two kinds of removal methods, sequential removal method and simultaneous removal method, were introduced. Both methods showed similar removal efficiency over $85\%$ for 6 hrs. However, the sequential method converted the As contaminated water to acid state (pH 4.5), on the contrary, the simultaneous method maintained neutral state (pH 6.0). Therefore, simultaneous As removal method was ascertained as a suitable treatment technology of As contaminated water. Moreover, for more effective As(III) remediation technique, polypropylene textile which has the characteristics of high surface area, low specific gravity and flexibility was applied as alternative material of sand. The combined use of coated polypropylenes by simultaneous method showed much more prominent and rapid remediation efficiency over $99\%$ after 6 hrs; besides, it has practical advantages in replacement or disposal of adsorbent for simple conventional removal device.

Effect of Plasma-activated Water Process on the Growth and Functional Substance Content of Lettuce during the Cultivation Period in a Deep Flow Technique System (담액수경재배 시스템에서 플라즈마수 처리가 상추의 생육 및 페놀류 함량에 미치는 영향)

  • Noh, Seung Won;Park, Jong Seok;Kim, Sung Jin;Kim, Dae-Woong;Kang, Woo Seok
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.464-472
    • /
    • 2020
  • We suggest a hydroponic cultivation system combined with a plasma generator to investigate the changes in the growth and functional substance content of lettuces during the cultivation period. Lettuce seedlings of uniform size were planted in semi-DFT after seeding for 3 weeks, and the plasma-activated water was intermittently operated for 1 hour at an 8 hours cycle for 4 weeks. Lettuces grew with or without plasma-activated water with the nutrient solution in hydroponics culture systems. Among the reactive oxygen species generated during plasma-activated water treatment, brown spots and necrosis appeared in the individuals closer to the plasma generating device due to O3, and there was no significant difference in the growth parameters. While the rutin and total phenolic content of the lettuce shoot grown in the nutrient solution were higher than that of the plasma-activated water, epicatechin contents in plasma-activated water were significantly greater than the nutrient solution. However, in the roots, all kinds of secondary metabolites measured in this work, rutin, epicatechin, quercetin, and total phenolic contents, were significantly higher in the plasma-activated water than the control. These results were indicated that the growth of lettuce was decreased due to the reactive oxygen species such as ozone in the plasma-activated water, but the secondary metabolites in the root zone increased significantly. It has needed to use this technology for the cultivation of root vegetables with the modified plasma-activated water systems to increase secondary metabolite in the roots.

A STUDY OF INTRAORAL ANATOMIC LANDMARKS OF KOREAN ADULT-UPPER JAW (성인 유치악자 상악골의 악궁과 치열궁의 형태에 관한 조사)

  • Oh, Yu-Ree;Lee, Sung-Bok;Park, Nam-Soo;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.753-768
    • /
    • 1995
  • For accurate impression taking of dental patient and esthetic denture treatment of ednetulous patient, measuring between intraoral anatomic landmarks is useful.In this study the subjects selected at a random were two-jundred forty persons with a mean age 22.5(range 21-24) and were taken impression of by irreversible hydrocolloid impression material(Alginate). On the study model made by dental stone, each individual tray was made and final impresion was taken by border moilding. On final model measurings were performed with 3-dimensional measuring device and the values were analyzed by t-test The results is following : ABOUT THE MEASURED VALUES. 1. The width between maxillary right and left canine cusp tip was average 36.44mm(s.d. 2.48), man 36.67mm, woman 35.83mm(p<0.05). 2. The width between labial height of contour of maxillary right and left canine was average 40.08mm(s.d. 2.42), man 40.29mm, woman 39.52mm(p<0.05). 3. The width between mesio-lingual cusps of maxillary first molar was average 43.14mm(s.d. 3.33), man 43.56mm, woman 42.05mm(p<0.05). 4. The width between buccal alveolar ridge on axis of mesiolingual cusp of right and left maxillary first molar was average 64.89mm(s.d. 3.88), man 65.58mm, woman 62.92mm(p<0.05). 5. The width between buccal alveolar ridge on axis of mesiolingual cusp of right and left maxillary second molar was average 68.58mm(s.d. 3.91), man 69.29mm, woman 66.30mm (p<0.05). 6. The width between right and left hamular notch was average 49.80mm(s.d. 3.96), man 50.70mm, woman 48.20mm(p<0.05). 7. The length from labial heigth of contour of maxillary central incisor to center of incisive papilla was average 9.52mm(s.d. 1.18), man 9.46mm, woman 9.63mm(p>0.05). 8. The length from labial heigth of contour of maxillary central incisor to palatine fovea was average 53.27mm(s.d. 2.93), man 53.93mm, woman 52.08mm(p<0.05). 9. The center of incisive papilla ws located posterior to intercanine line at 0.40mm(s.d. 1.16), man 0.51mm, woman 0.11mm(p<0.05). 10. The height from incisal edge of maxillary central incisor to the labial vestibule was average 21.84mm(s.d. 1.38), man 22.01mm, woman 21.00mm(p<0.05). 11. The height from mesiolingual cusp of maxillary first molar to buccalvestible was average 17.45mm(s.d. 1.42), man 17.56mm, woman 17.08mm(p>0.05). 12. The height from hamular notch to standard occlusal plane was average 6.84mm(s.d. 1.06), man 6.91mm, woman 6.70mm(p>0.05). 13. The height from the deepest point of palatal vault to standard occlsalplane was average 19.95 mm(s.d. 2.03), man 20.19mm, woman 19.12mm(p<0.05). ABOUT THE ARCH FORM 1. The arch form was able to classify into four typr by the rate of the measured values. Each arch form distribution was that the 1 group had 32.46% the 2 group 2.19%, the 3 group 52.83%, the 4 group 12.72%. The sexual composition was that in 1 group man had 73.5%, woman 26.5%, in 2 group man had 40.0%, woman 60.0%, in 3 group man had 83.3%, woman 16.7%, and in 4 group man had 55.17%, woman 44.83%. 2. When canine cusp tip was marked as point O, the intersection point between labial height of contour of maxillary central incisor and intermaxillary suture as point A, height of contour of maxillary second molar buccal alveolar ridge as B point, ${\angle}$AOB was measured $133.8^{\circ}$for the 1 group, $133.0^{\circ}$for the 2 group, $132.3^{\circ}$for the 3 group, $128.9^{\circ}$for the 4 group.

  • PDF

Impact of Device Evolution in Transcatheter Closure of Patent Ductus Arteriosus Using Duct-Occlud Coils : Comparison of Mid-term Results (경피적 동맥관 폐쇄술에 사용된 Duct-Occlud Coil의 종류에 따른 중-단기 결과의 비교)

  • Kim, Myung Kwan;Han, Dong Ki;Choi, Jae Young;Kim, Yuria;Yoo, Byung Won;Choi, Deok Young;Sul, Jun Hee;Lee, Sung Kue
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.2
    • /
    • pp.158-164
    • /
    • 2005
  • Purpose : We reviewed the therapeutic results of various Duct-Occlud coils(pfm AG, $K{\ddot{o}}ln$, Germany) to evaluate the efficacy of the most-recently modified Duct-Occlud coil(Nit-Occlud) in the transcatheter closure of patent ductus arteriosus(PDA), including large defects more than 4 mm in diameter. Methods : Two hundred and five patients who underwent percutaneous PDA occlusion using Duct-Occlud devices from March 1996 to December 2003 were enrolled and four types of Duct-Occlud [Standard(S), Reinforced(R), Reinforced reverse cone(RR) and Nit-Occlud(N)] were used in this study. The patients were followed up by echocardiogram and physical examination before discharge, one month, six months and 12 months after the procedure. Results : The rate of residual shunt according to the type of Duct-Occlud were as follows : S-54%, R-72%, RR-50%, N-14%(P<0.05 compared with other devices) at one month, S-25%, R-44%, RR-37%, N-0%(P<0.05 compared with other devices) at six months, S-8%, R-8%, RR-4%, N-0%(P<0.05 compared with S and R) at 12 months and later. Nit-Occlud coil showed the complete occlusion of PDA after six months of follow-up, even in 12 patients with relatively large PDA(>4 mm). Conclusion : The transcatheter closure of PDA using Duct-Occlud was an effective treatment and our study revealed that a Nit-Occlud coil which showed higher rate of occlusion even in PDA with large diameters over than 4 mm, was a more effective modality compared to previous devices.

A Study on the Culture of Incense in the Period of T'ang (당대 향문화 연구)

  • Chun Hea-Sook;Lee Ae-Ryun
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.7 no.3
    • /
    • pp.113-127
    • /
    • 2005
  • From the ancient times, incense was used for various usages including a means of beauty expression with flavor, a medicine for disease treatment and a device for religious event or ritual. The period of T'ang was the times when cultural and material exchanges with foreign countries were very actively made under the political openness of the Chinese nation. Here the exchanges were made mainly through inland trade, called Silk Road(絲綢之路) and marine trade routes, Incense Road(香料之路). This indicates that incense was one of the main items actively traded at that time. In addition, literatures of the T'ang period show that in the Chinese nation, a wide range of classes from the imperial family to the public used incense for many different purposes. This suggests that the culture of incense was deeply prevailed and very socially significant in T'ang. This study investigated social factors that promoted the incense culture of T'ang and the applications and types of incense widely used in the period of T'ang. First, influential religions and the openness of sex culture were main social factors that made incense culture flourish in the period of T'ang. Above all, two main religions of the Chinese nation, Buddhism and Taoism became secularized under political protection by the imperial family. As Buddhism was popularized, the Buddhist ritual of incense burning made a contribution to making public incense culture. Providing its doctrines of eternal youth and eternal life, Taoism necessarily used incense to form a Taoistic climate. The flourishment of the foresaid religion in T'ang added more fuel to that of incense culture in the Chinese nation. The openness of sex culture brought about the Inauguration of the empress, improvement in female position and free relationships between man and woman. It was accelerated by sexology as a method of eternal youth provided by Taoism. The opened culture also developed the culture of kibang where female entertainers called kinyeo consumed lots of incense for decoration and sexual desire stimulation. These open climates of T'ang society made a great contribution to making incense culture, especially for decoration, prevailed throughout the Chinese nation. Second, types of incense prevailed and widely used in the period of T'ang included olive incense, germander(廣藿香), olibnum(乳香), myrrh Resinoid(沒藥), jia Xiang(甲香), clove(丁香) and Shen xian(沈香), all of which were imported from foreign nations and had various applications. Specifically, olive incense, germander(廣藿香), olibnum(乳香) and myrrh Resinoid(沒藥) were used for religious purposes while, jia Xiang(甲香), clove(丁香) and Shen xian(沈香) for the purposes of religion and decoration. In conclusion, a number of social factors including political, religious and medical purposes and the openness of sex culture set fundamentals on which the culture of incense was extensively developed and established as a social trend in T'ang. In the Chinese nation, incense culture was not just an option for taste, but a part of life style social members needed to know. People of T'ang not only enjoyed incense mainly for purposes of religion, pleasure and make-up, but also had the wisdom to know various effects of incense, curiosity about such new things and the will to imitate and pursue alien culture, resultantly flourishing incense culture. Thus the culture of incense represented many social aspects of T'ang.

  • PDF