• Title/Summary/Keyword: treatment device

Search Result 1,531, Processing Time 0.038 seconds

Factors related to the difference in the incidence of caries between children in fluoridated and non-fluoridated areas (수돗물불소농도조정사업 지역과 비사업지역 아동 간의 치아우식 발생 격차 관련요인)

  • Han, Sang-Jun;Kwon, Yong-Bong;Kim, Se-Yeon;Kim, Ji-Soo;Lee, Jung-Ha;Kim, Jin-Bom
    • Journal of Korean Academy of Oral Health
    • /
    • v.42 no.4
    • /
    • pp.136-144
    • /
    • 2018
  • Objectives: The aim of this study is to analyze the differences in factors related to the incidence of dental caries between children in fluoridated and non-fluoridated areas and compared the DMFT and DMFS scores to confirm the effect of water fluoridation program (WFP) in Geoje and Changwon. Methods: The oral health examination and questionnaire survey were conducted in fluoridated and non-fluoridated areas. The number of surveyed children aged 8, 10, and 12 years in the fluoridated and non-fluoridated area of two cities was 1,524 and 1,383, respectively. Self-recorded questionnaires included self-perception of their own dental health, daily toothbrushing frequency, intake frequency of cariogenic sweet snacks and beverages, experience of gingival bleeding, experience of unmet dental treatment, and use of oral hygiene device except for toothbrush and toothpaste. The prevalence of caries and fissure-sealant status were surveyed. The logistic regression analysis was used to analyze the difference in children's self-rated oral health status between the fluoridated and non-fluoridated area. The mean number of sealed teeth and surfaces, marginal means of the DMFT and DMFS scores adjusted for the difference in the samples' sex distribution, and region were compared between the fluoridated and non-fluoridated areas. Results: In the fluoridated area, the experience rate of unmet dental treatments was higher among children aged 10 years, intake frequency of cariogenic sweet snacks and beverages were higher among the whole sample, and experience rate of professional fluoride application were lower than in the non-fluoridated area. The DMFT score for permanent dentition adjusted for differences in sex, region, and mean number of fissure-sealed teeth in the fluoridated area was significantly lower among whole samples and 8-, 10-, and 12-year-olds alone than in the non-fluoridated area. Conclusions: WFP can alleviate oral health inequality because it is effective in reducing the incidence of caries among children is disadvantaged demographic, socioeconomic, and cultural contexts.

Preliminary Study on Usual Cold or Heat as a Risk Factor for Hypertension in an University Faculty (일개 대학 교직원 집단에서 고혈압의 위험요인으로서의 평소 한열 예비 연구)

  • Jung, Kyung Sik;Kim, Yun Young;Baek, Young Hwa;Jang, Eunsu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.33 no.4
    • /
    • pp.226-232
    • /
    • 2019
  • This study was aimed to reveal that the usual cold or heat state was associated with hypertension and could be a risk. We emailed educational personnel in D university to join this study and 182 subjects participated in from March to December in 2016. The usual cold or heat diagnosis was conducted by two experts who had over 10 years expertise. The blood pressure was measured from the subjected after 10 minute rest with Jawon medical device. The hypertension was diagnosed by the guide of the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. The frequency analysis was used in general characteristics, Pearson's Correlation Coefficient analysis was conducted in among continuous variables, and chi-square test was also used between hypertension and cold or heat group. Logistic regression was analyzed to generate the odds ratios (ORs) and 95% confidence interval (CI) for hypertension. The cold score was suggested to have negative association with Body mass Index (BMI, -.374, p<.001), systolic blood pressure (-.333, p<.001), and diastolic pressure (-.261, p<.001). The heat score was analyzed to have positive association with Body mass Index (.413, p<.001), systolic blood pressure (.249, p<.001), and diastolic pressure (.156, p<.001). The distribution of the cold group (35.1%) and non-cold group (64.9%) in hypertension was significantly different (p=0.18). The distribution of the heat group (62.2%) and non-heat group (37.8%) was significantly different (p=0.27). The usual cold was associated with decreased ORs (ORs 0.405, 95% CI=0.191-0.857), and usual heat was associated with increased ORs (ORs 2.327, 95% CI=1.108-4.888). However, after adjusting body mass index, sex, and smoking, the association was not significantly different. It is possible that usual cold or heat associate with hypertension. Further study is needed to show that usual heat may be a independent risk factor for hypertension through follow up design.

Effect of Cognitive Behavioral Art Treatment Using Smart Devices on the Changes of an Emotionally Disturbed Child (스마트기기 활용 인지행동 미술치료가 정서불안 아동의 변화에 미치는 효과)

  • Park, Mija;Lim, Keol
    • Journal of Digital Convergence
    • /
    • v.17 no.5
    • /
    • pp.89-97
    • /
    • 2019
  • The purpose of this study was to understand educational changes and effects of cognitive behavioral art therapy using the smart device. The participant of the study was a 4th grade of male elementary school student who had aggressiveness and impulsiveness with emotional instability. The study was conducted one to two times a week for six months with a total of 30 educational sessions. Among 80 minutes per session, 60 minutes of art therapy and 20 minutes of cognitive behavioral therapy were applied, and during the sessions, cognitive action art therapy (drawing and shaping activities), cognitive restructuring, behavioral modification, systemic dullness, social skills training, empathy and landscaping training were applied. For the numeral assessment, Traffic Anxiety Inventory for Children (TAIC), Beck Anxiety Inventory (BAI) and emotional instability measures were used. Research showed that cognitive behavioral art therapy using smart devices had the effect of positive emotional change in children with emotional anxiety, and based on this, future development directions including systematic instructional design, scientific analysis and feedback technologies were discussed.

Evaluation of Possibility of using an Ultrasound Probe Sterilizer using the Steam Fumigation Method (증기훈증방식을 이용한 초음파 프로브 소독기의 사용 가능성 평가)

  • Ha, Jeong-Min;Heo, Yeong-Cheol;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.195-201
    • /
    • 2022
  • This study aims to evaluate the feasibility of the disinfection of clinical ultrasound probes using the vapor fumigation method, which can quickly achieve high-level disinfection. Upon the inspection of the microbial contamination level of clinically used ultrasound probes, nine different types of bacteria were detected. The disinfection efficacy of 7.5% and 35% hydrogen peroxide (H2O2) was comparatively tested for the detected microbes. The 35% H2O2 demonstrated superior efficacy per disinfection duration. No significant change was observed in the rubber component of the ultrasound probes as a result of the 35% H2O2 disinfection treatment. The probes were contaminated with the microbes detected in the microbial contamination level inspection and subsequently disinfected using the novel medical disinfector that utilizes the vapor fumigation method. As a result, the disinfection using the novel device achieved 100% eradication of the microbes from the probes.This study demonstrates that the novel vapor fumigation method-based disinfector provides a faster and more powerful means of disinfection than the conventional disinfection methods. Therefore, the novel disinfector has the potential to be used as a convenient ultrasound probe disinfector in clinical settings.

Growth of Ga2O3 films on 4H-SiC substrates by metal organic chemical vapor deposition and their characteristics depend on crystal phase (유기 금속 화학 증착법(MOCVD)으로 4H-SiC 기판에 성장한 Ga2O3 박막과 결정 상에 따른 특성)

  • Kim, So Yoon;Lee, Jung Bok;Ahn, Hyung Soo;Kim, Kyung Hwa;Yang, Min
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.4
    • /
    • pp.149-153
    • /
    • 2021
  • ε-Ga2O3 thin films were grown on 4H-SiC substrates by metal organic chemical vapor deposition (MOCVD) and crystalline quality were evaluated depend on growth conditions. It was found that the best conditions of the ε-Ga2O3 were grown at a growth temperature of 665℃ and an oxygen flow rate of 200 sccm. Two-dimensional growth was completed after the merge of hexagonal nuclei, and the arrangement direction of hexagonal nuclei was closely related to the crystal direction of the substrate. However, it was confirmed that crystal structure of the ε-Ga2O3 had an orthorhombic rather than hexagonal. Crystal phase transformation was performed by thermal treatment. And a β-Ga2O3 thin film was grown directly on 4H-SiC for the comparison to the phase transformed β-Ga2O3 thin film. The phase transformed β-Ga2O3 film showed better crystal quality than directly grown one.

Verification of Shielding Materials for Customized Block on Metal 3D Printing (금속 3D 프린팅을 통한 맞춤형 차폐블록 제작에 사용되는 차폐 재료 검증)

  • Kyung-Hwan, Jung;Dong-Hee, Han;Jang-Oh, Kim;Hyun-Joon, Choi;Cheol-Ha, Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.25-30
    • /
    • 2023
  • As 3D printing technology is used in the medical field, interest in metal materials is increasing. The Department of Radiation Oncology uses a shielding block to shield the patient's normal tissue from unnecessary exposure during electron beam therapy. However, problems such as handling of heavy metal materials such as lead and cadmium, reproducibility according to skill level and uncertainty of arrangement have been reported. In this study, candidate materials that can be used for metal 3D printing are selected, and the physical properties and radiation dose of each material are analyzed to develop a customized shielding block that can be used in electron beam therapy. As candidate materials, aluminum alloy (d = 2.68 g/cm3), titanium alloy (d = 4.42 g/cm3), and cobalt chromium alloy (d = 8.3 g/cm3) were selected. The thickness of the 95% shielding rate point was derived using the Monte Carlo Simulation with the irradiation surface and 6, 9, 12, and 16 energies. As a result of the simulation, among the metal 3D printing materials, cobalt chromium alloy (d = 8.3 g/cm3) was similar to the existing shielding block (d = 9.4 g/cm3) in shielding thickness for each energy. In a follow-on study, it is necessary to evaluate the usefulness in clinical practice using customized shielding blocks made by metal 3D printing and to verify experiments through various radiation treatment plan conditions.

Analysis Characteristic of Non-point source in Petrochemical (석유화학업종에서의 비산배출원 배출 특성 분석)

  • Chiwan, Ku;Seunghyo, An;Byungchol, Ma
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.45-51
    • /
    • 2022
  • Technologies for collecting and treating pollutants from point sources are steadily being developed, but Non-point sources, it is difficult to develop emission treatment technologies and effective emission coefficients. However, since non-point sources make up about 60% of domestic emissions, and first of all, the method of calculating emissions should be reasonable, and the workplace should develop emission reduction technologies based on this. This study suggest the effectiveness and improvement of the emission coefficient currently used for the petrochemical industry with high emissions. The emission characteristics of non-point sources emission were confirmed by analyzing the LDAR (Leak Detection And Repair) data of OO company located in Yeosu, Jeollanam-do over the past five years. As a result, there was no difference in discharge characteristics according to fluid phase, but it was confirmed that there was a difference in the size of the device and the characteristics of each manufacturer. In addition, it was confirmed that the emission coefficient applied in the petrochemical industry was larger than that of the refining industry, and improvement measures were suggested. Through these studies, it is expected that emission coefficients specialized in the petrochemical industry can be applied and that the workplace itself will contribute to the development of technologies that can drastically reduce them.

Sleep Disordered Breathing in Children (어린이의 수면호흡장애)

  • Yeonmi, Yang
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.4
    • /
    • pp.357-367
    • /
    • 2022
  • Sleep disordered breathing (SDB) is a disease characterized by repeated hypopnea and apnea during sleep due to complete or partial obstruction of upper airway. The prevalence of pediatric SDB is approximately 12 - 15%, and the most common age group is preschool children aged 3 - 5 years. Children show more varied presentations, from snoring and frequent arousals to enuresis and hyperactivity. The main cause of pediatric SDB is obstruction of the upper airway related to enlarged tonsils and adenoids. If SDB is left untreated, it can cause complications such as learning difficulties, cognitive impairment, behavioral problems, cardiovascular disease, metabolic syndrome, and poor growth. Pediatric dentists are in a special position to identify children at risk for SDB. Pediatric dentists recognize clinical features related to SDB, and they should screen for SDB by using the pediatric sleep questionnaire (PSQ), lateral cephalometry radiograph, and portable sleep monitoring test and refer to sleep specialists. As a therapeutic approach, maxillary arch expansion treatment, mandible advancement device, and lingual frenectomy can be performed. Pediatric dentists should recognize that prolonged mouth breathing, lower tongue posture, and ankyloglossia can cause abnormal facial skeletal growth patterns and sleep problems. Pediatric dentists should be able to prevent these problems through early intervention.

A Study on the Analysis of Virus Barrier Materials in a Chest X-ray Laboratory to Respiratory and Droplet Infections Only Patients (호흡기 및 비말감염 환자 전용 흉부 X-선 검사실의 바이러스 차단제 분석에 관한 연구)

  • Kim, Hyeon-Ju;Lee, Jun-Ho;Choi, Kwan-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.169-175
    • /
    • 2022
  • In this study, envisioned a laboratory equipped with virus blocking equipment for chest X-ray examinations of respiratory or droplet-transmitted virus-infected patients, and the material with the least deterioration in X-ray output and image quality among the proven blocking materials that block viruses in the design process. and experimented to find the thickness. As a result, when 1 cm of acrylic was applied, the X-ray output was reduced by only about 3.27 % compared to the absence of the barrier material, the SNR was 40.7 and CNR was 30.9, which was the best. The SSIM index result was analyzed as 0.891, which was analyzed to be implemented as the most similar image compared to the original image. The barrier material applied in the research method was objective in that it used a product approved by the Ministry of Food and Drug Safety. the results of this study are expected to provide useful information when installing X-ray examination facilities for the diagnosis and treatment of respiratory-related virus-infected patients in the future.

Effect of plasma treatment using underwater non-thermal dielectric barrier discharge to remove antibiotics added to fish farm effluent (양식장 배출수에 첨가된 항생제 제거 위한 수중 비열 유전체장벽 방전 플라즈마 처리 효과)

  • Kyu Seok Cho;Han Seung Kang
    • Korean Journal of Environmental Biology
    • /
    • v.40 no.4
    • /
    • pp.641-650
    • /
    • 2022
  • The purpose of this study was to compare the efficiency of air and oxygen injected into the underwater non-thermal dielectric barrier discharge plasma (DBD plasma) device used to remove five types of antibiotics (tetracycline, doxycycline, oxytetracycline, clindamycin, and erythromycin) artificially contained in the fish farm discharge water. The voltage given to generate DBD plasma was 27.8 kV, and the measurement intervals were 0, 0.5, 1, 2, 4, 8, 16 and 32 minutes. Tetracycline antibiotics significantly decreased in 4 minutes when air was injected and were reduced in 30 seconds when oxygen was injected. After the introduction of air and oxygen at 32 minutes, 78.1% and 95.8% of tetracycline were removed, 77.1% and 96.3% of doxycycline were removed, and 77.1% and 95.5% of oxytetracycline were removed, respectively. In air and oxygen, 59.6% and 83.0% of clindamycin and 53.3% and 74.3% of erythromycin were removed, respectively. The two antibiotics showed lower removal efficiency than tetracyclines. In conclusion, fish farm discharge water contains five different types of antibiotics that can be reduced using underwater DBD plasma, and oxygen gas injection outperformed air in terms of removal efficiency.