• Title/Summary/Keyword: treatment device

Search Result 1,531, Processing Time 0.03 seconds

A Study of The Effect of Waiting time for Operation in the Operating Room on Preoperative Patients (수술환자에 있어 수술실내에서 수술대기 시간이 불안에 미치는 영향에 관한 연구)

  • Lee, Hea-Won;Lee, Kyu-Chung;Kim, Hae-Ock;Lee, Haik-Ock;Kim, Hea-Suk;Lee, Mi-Kyung;Song, Mal-Soon
    • The Korean Nurse
    • /
    • v.29 no.3
    • /
    • pp.36-48
    • /
    • 1990
  • This study was attempted to provide us with basic information on how to improve understanding with patients for operation, and to offer then better nursing and treatment. This kind of study will help scientific application to nursing practice and operating room. The data was collected by interviewing 29 patients who underwent the elective surgery under the general anesthesia at Y hospital in Seoul. The interview ran from October 15 to December 15, 1989. The research instrument was a anxiety measurement device (SAAI) originally developed by Spielberger, et al and modified by Jung-Tack Kim. 1. Hypothesis Testing Hypothesis one was that there would be a difference in state anxiety level according to a time difference in watiting for operation. This hypothesis was rejected(state.anxiety level one hour before operation P>.05, r-.747, State anxiety level half an hour before operation P>.05, r-.1550, state anxiety level just before operation, P>.05, r=.1099). However, state anxiety, evel appeared to be associated with a longer watiting period, like one day before operation (P<.05, r-.4628). Hypothesis two was that there would be a difference according to state anxiety level of patients for operation. This was rejected. (Change of blood perssure in systolie P>.05 r=.1082, Change of blood pressure in diastolic P>.05, r=.088, Change of pulse rate, P>.05, r-1.909) 2. Examining trait anxiety and state anxiety levels, the average level of trait anxiety was 42.034, and the average level of state anxiety one day before operation was 43,000. The average level of state anxiety was averaged 42.356 in a waiting room for operation. 3. Examining the state anxiety level by time period, the one hour before was 42.379 the level half an hour before 42.276, and the level just before operation 42.414. The low level of state anxiety was due to the fact that premedication was not eliminated. 4. Age and time period like one day before operation was related to state anxiety level (F=5.271, P<.0.01) and blood pressure in waiting room for operation. That is, state anxiety level and blood pressure of patients one day before operation appeared high. Sex was relation to changes of blood pressure ; the blood pressure of male patients appeard higer than of female patients. A marital status was also related anxiety level one hour before operation the married patient for operation showed a higher state anxiety level than that of the unmarried patient for operation. Education was similarily related to trait anxiety level in which highly educated patients show lower levels of trait anxiety than poorly educated ones. Motive for hospitalization was related to state anxiety level for patient one hour before operation (F=6.464, P<.05) likewise, patients who are supposed to undergo operation hastily showed higher levels of anxiety than patients who expect elective surgeries.

  • PDF

Experimental Study on the Stimulating Effect of Commercial Moxa Combustion through the Measurement of Temperature -Focused on Combustion time and temperature- (온도 측정을 통한 상용 쑥뜸의 자극효과에 대한 실험적 연구 -연소시간 및 연소온도를 중심으로-)

  • Lee, Geon-Mok;Yang, Yoo-Sun;Lee, Gun-Hyee
    • Journal of Acupuncture Research
    • /
    • v.19 no.2
    • /
    • pp.114-127
    • /
    • 2002
  • Objective : The purpose of this study is to investigate the mechanism and effect of moxibustion objectively and to be used as the quantitative data for developing the new thermal stimulating treatment by observing the combustion time and temperature of commercial moxaes. Methods : We have selected two types(large-size moxa A(LMA), large-size moxa B (LMB)) among large moxaes used widely in the clinic. We examined combustion times, temperatures in each period during a combustion of moxa. Results : 1. The combustion time in the preheating period was about 30sec in both moxaes on the non-contact heated surface. 2. The combustion time in the heating period was about 345sec in LMA and about 1391 sec in LMB, about 4 times longer in LMB on the non-contact surface. 3. The maximum temperature in the heating period was $44.5^{\circ}C$ in LMA and $45.4^{\circ}C$ in LMB respectively, higher by $0.9^{\circ}C$ in LMB. The average temperature in the heating period was $35.5{\sim}37.6^{\circ}C$ in LMA and $36.0{\sim}39.8^{\circ}C$ in LMB, a little higher in LMB. 4. The combustion time in the retaining period in LMA was 45.4sec and 13% of that in the heating period, and in LMB 594.7sec and 43% of that in the heating period on the non-contact surface. 5. On the point(PH) measured maximum temperature, the average temperature during the retaining period was $44.0^{\circ}C$, $42.9^{\circ}C$ respectively and the temperature at an end of the retaining period was $43.0^{\circ}C$, $40.2^{\circ}C$ respectively. 6. The time at a beginning of the cooling period was about 418 sec from ignition in LMA and 2021sec in LMB, and the temperature at that time was $36.9{\sim}39.1^{\circ}C$ on the non-contact surface. Conclusion : It was thought that not only the figure of moxicombustion device, but also the form and size of moxa had influence on the combustion characteristics deciding the performance of stimulus seriously.

  • PDF

Tensile Bond Strength of Glass Ionomer Cements (글라스 아이오노대 시멘트의 인장접착강도)

  • BYUN, Seung Min;KWON, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.26 no.3
    • /
    • pp.317-324
    • /
    • 1996
  • This study was conducted to evaluate the tensile bond strength of three commercially available glass ionomer cements as orthodontic bracket adhesives. 120 premolars extracted for orthodontic treatment were prepared for bonding and standard edgewise brackets were bonded with Shofu Glaslonomer Cement (Shofu Co., U.S.A.), GC Fuji ItGC Co., Japan), KETAC-CEM(ESPE Co., West Germany) with different P/L ratio. The tensile bond strength was tested by Instron testing device after 24hours and 3months from bonding. After debracketing, bracket bases were examined to determine the failure sites. The results of this study were as follows: 1. KETAC CEM showed the highest bond strength other than measurement after 24 hours and at its original P/L ratio, and seemed to have clinically a proper bond strength. It seemed, however, that both Shofu Giaslonomer Cement and GC Fuji I had an inappropriate bond strength. 2. The incorporation of additional powder into the mixture improved the tensile bond strength. 3. Prolonged storage time improved the tensile bond strength. 4. Of the failure, failure occured at the tooth-adhesive interface(54.2%) was the most common type. The second type of failure(36.7%) was combination type, where part of the adhesive remained on the tooth and part on the bracket. And the last type of failure(9.1%) occured at the adhesive-bracket interface.

  • PDF

Effects of Argon-plasma Jet on the Cytoskeleton of Fibroblasts: Implications of a New Approach for Cancer Therapy (Fibroblasts 세포주의 세포골격에서 아르곤 플라즈마의 효과: Cancer Therapy의 새로운 접근방법)

  • Han, Ji-Hye;Nam, Min-Kyung;Kim, Yong-Hee;Park, Dae-Wook;Choi, Eun Ha;Rhim, Hyangshuk
    • KSBB Journal
    • /
    • v.27 no.5
    • /
    • pp.308-312
    • /
    • 2012
  • Argon-plasma jet (Ar-PJ) is generated by ionizing Ar gas, and the resulting Ar-PJ consists of a mixture of neutral particles, positive ions, negative electrons, and various reactive species. Although Ar-PJ has been used in various biomedical applications, little is known about the biological effects on cells located near the plasma-exposed region. Here, we investigated the effects of the Ar-PJ on actin cytoskeleton of mouse embryonic fibroblasts (MEFs) in response to indirect as well as direct exposure to Ar-PJ. This Ar-PJ was generated at 500 mL/min of flow rate and 100 V electric power by our device mainly consisting of electrodes, dielectrics, and a high-voltage power supply. Because actin cytoskeleton is the key cellular machinery involved in cellular movement and is implicated in regulation of cancer metastasis and thus resulting in a highly desirable cancer therapeutic target, we examined the actin filament architectures in Ar-PJ-treated MEFs by staining with an actin-specific phalloidin labeled with fluorescent dye. Interestingly, the Ar-PJ treatment causes destabilization of actin filament architectures in the regions indirectly exposed to Ar-PJ, but no differences in MEFs treated with Ar gas alone and in untreated cell control, indicating that this phenomenon is a specific cellular response against Ar-PJ in the live cells, which are indirectly exposed to Ar-PJ. Collectively, our study raises the possibility that Ar-PJ may have potential as anti-cancer drug effect through direct destabilization of the actin cytoskeleton.

Development of depression diagnosis system using EEG signal (뇌파 측정 신호를 이용한 우울증 진단장치 개발)

  • Kim, Kyu-Sung;Jung, Ju-Hyeon;Lee, Woo-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.452-458
    • /
    • 2017
  • In this study, a device was developed for diagnosing depression using EEG signals from July 2016 to June 2017. For normal people, the left alpha rhythm is more activated than the right alpha rhythm, but for the depressed patients, the right alpha rhythm is more activated than the left one. An analog circuit and digital low pass filter were used for noise removal and amplification of EEG, and the Hamming window function was applied to eliminate the signal leakage generated by the fast Fourier transform. To verify the validity of the developed diagnosis system, the EEG of 20 university students in the 3rd and 4th grade with an average age of 24 years was measured. Calculations of the relative value of the left and right alpha rhythm for the depression diagnosis revealed a minimum, maximum, and mean value of 66.7, 113.3, and 92.2, respectively. In addition, 7 out of 20 subjects were between 90 and 95, and those with a higher mean deviation of approximately 20 tended to have mild depression. These results can provide meaningful data for the development of depression treatment equipment by solving the left and right brain asymmetry problem, and it may be applied usefully to diagnose depression after clinical trials on a large number of depressed patients.

Subnet Generation Scheme based on Deep Learing for Healthcare Information Gathering (헬스케어 정보 수집을 위한 딥 러닝 기반의 서브넷 구축 기법)

  • Jeong, Yoon-Su
    • Journal of Digital Convergence
    • /
    • v.15 no.3
    • /
    • pp.221-228
    • /
    • 2017
  • With the recent development of IoT technology, medical services using IoT technology are increasing in many medical institutions providing health care services. However, as the number of IoT sensors attached to the user body increases, the healthcare information transmitted to the server becomes complicated, thereby increasing the time required for analyzing the user's healthcare information in the server. In this paper, we propose a deep learning based health care information management method to collect and process healthcare information in a server for a large amount of healthcare information delivered through a user - attached IoT device. The proposed scheme constructs a subnet according to the attribute value by assigning an attribute value to the healthcare information transmitted to the server, and extracts the association information between the subnets as a seed and groups them into a hierarchical structure. The server extracts optimized information that can improve the observation speed and accuracy of user's treatment and prescription by using deep running of grouped healthcare information. As a result of the performance evaluation, the proposed method shows that the processing speed of the medical service operated in the healthcare service model is improved by 14.1% on average and the server overhead is 6.7% lower than the conventional technique. The accuracy of healthcare information extraction was 10.1% higher than the conventional method.

The effect of oral health behavior of the visually impaired on DMFT index (시각장애인의 구강보건행태가 DMFT지수에 미치는 영향)

  • Lee, Jong-Hwa;Lee, Seung-Hee;Yun, Hyun-Kyung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.331-342
    • /
    • 2017
  • Objectives: This study aimed at helping oral health prevention of the blind and related management plan, which is defined as the influence factors between missing and filled permanent teeth index and general feature and oral health behavior of the blind in Korea (estimates 229,678 persons) using data of the 6th Korea National Health and Nutrition Examination Survey from 2014 Korea Centers For Disease Control and Prevention. Methods: The blind over the age of 30 were selected as study subjects who have conducted health survey and dental inspections in KNHANES VI-2. Estimates of the subjects were 229,67 persons. For analyzing data, general linear models: GLM and covariance analysis were conducted to identify the relation between general feature and oral health behavior and missing and filled permanent teeth index. SPSS 21 statistical program was used, which is possible to conduct complex sampling design, and the significance level was 0.05. Results: The missing and filled permanent teeth index was 8.58 points. Regarding the results of the analysis, R-squared of the missing and filled permanent teeth index depending on general features of the blind was 0.839 points, which shows gender, age, residence, education level, individual income, disability rating, kinds of health insurance, marital status and recipient of basic living had an effect on the missing and filled permanent teeth index. R2 of the missing and filled permanent teeth index depending on oral health form of the blind was 0.728 points, which shows oral examination, dental treatment, smoking and toothbrushing after lunch had an effect on the missing and filled permanent teeth index. Conclusions: With the result of this study, we found the oral health actual condition of the blind in Korea. Therefore, it is considered that the government needs to introduce the personalized oral health education program to maintain oral health of the blind and to develop a program that uses braille and voice device which enables to access and utilize to improve oral health behavior that the government could use it as a reference to establish the policy plan.

Radiographic Measurement of Ankle Lateral Stability in Normal Korean Adults (정상 한국 성인에서 발목관절 외측 안정성의 방사선학적 계측)

  • Shon, Hyun-Chul;Kim, Yong-Min;Kim, Dong-Soo;Choi, Eui-Sung;Park, Kyoung-Jin;Cho, Byung-Ki;Park, Ji-Kang;Hong, Kyung-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • Purpose: Anterior drawer and varus stress test are commonly used for radiologic evaluation of chronic lateral ankle instability. However, there are controversies regarding the method of measurement and the normal value. This study was performed to investigate radiologic normal values in normal Korean adults and to analyze differences by age and gender. Materials and Methods: Sixty Korean adults were recruited and divided in three groups (20 in their twenties, 20 in their thirties, 20 in their forties). There were 10 males and 10 females in each group. The selection criteria were no history of ankle injury and no evidence of instability on physical examination. Radiologic measurement of varus talar tilt and anterior talar translation were performed through anterior and varus stress radiographs using Telos device (150N force). The measurement was repeated twice by three researchers, and intraobserver reproducibility and interobserver reliability were analyzed. The average talar tilt and anterior talar translation were obtained. Results: Talar tilt and anterior talar translation on ankle stress radiographs had good intraobserver reproducibility and interobserver reliability. Talar tilt was average $3.7^{\circ}$ and $5.1^{\circ}$ in male and female of twenties of age, $3.9^{\circ}$ and $4.8^{\circ}$ in their thirties, $3.4^{\circ}$ and $4.5^{\circ}$ in their forties. Anterior talar translation was average 3.5 mm and 4.2 mm in their twenties, 4.1 mm and 3.8 mm in their thirties, 3.6 mm and 4.1 mm in their forties. There was no significant difference in talar tilt and anterior talar translation by age. However, there was significant difference in talar tilt by gender. Conclusion: Normal range of talar tilt angle in Korean adults was below $8.3^{\circ}$, and normal range of anterior talar translation was below 7.6 mm. It seems to be able to serve as a good reference for radiologic evaluation and for treatment of chronic lateral ankle instability.

Evaluation and Design of Infiltration and Filtration BMP Facility (침투 여과형 비점오염저감시설의 설계 및 평가)

  • Choi, Ji-Yeon;Maniquiz, Marla Chua;Lee, So-Young;Kang, Chang-Guk;Lee, Jung-Yong;Kang, Hee-Man;Kim, Lee-Hyung
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.5
    • /
    • pp.475-481
    • /
    • 2010
  • Lots of pollutants typically originating from urban transportation are accumulating on the paved surfaces during dry periods and are washed-off directly to the river during a storm. Also, paved surfaces are contributing to increase in peak flows and volume of stormwater flows. These are the main reasons why the water quality of rivers and lakes remain polluted and still below standards. Currently, several management practices are being applied in developed countries but the design standards are still lacking. This research was conducted to develop a treatment technology that can be useful to address the problems concerning runoff quality and quantity. A lab scale infiltration device consisting of a pretreatment tank and media zone was designed and tested for various flow regimes characterizing the low, average and high intensity rainfall. Based on the experiments, the high intensity flow resulted to increase in outflow event mean concentration (EMC) of pollutants, about twice as much as the average outflow EMC. However, 78 to 88% of the total suspended solids were captured and retained in the pretreatment tank because of sedimentation. The removal of heavy metals such as zinc and lead was greatly affected by the vertical placement of woodchip layer prior to the media zone. It was observed that the high carbon content (almost 50%) in the woodchip provided opportunity for enhancing its uptake of metal by adsorption. The findings implied that the reduction of pollutants can be greatly achieved by means of proper pretreatment to allow for settling of particles with a combination of using high carbon source media like woodchip and a geotextile mat to reduce the flow before filtering into the media zone and finally discharging to the drainage system.

Surgical Treatment of Varicose Vein - TIPP(Transilluminated Powered Phlebectomy) - (정맥류 환자의 수술적 치료 -광투시 전도형 정맥적출요법-)

  • 이교준;김해균;정은규;강두영
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.144-148
    • /
    • 2002
  • The present study was done to determine the efficacy and safety of varicose vein removal using a minimally invasive, powered vein-extracting device with cutaneous transillumination and tumescent anesthesia techniques and then compared this to a retrospective group of conventional phlebectomy operations. There were 133 limbs in 104 patients(72 women, 32 men) treated with the use of the vein extractor aided by transcutaneous illumination. The hydrodissection was performed with Trivex™ Irrigated illuminator(Smith & Nephe $w^{ R}$) system using normal saline after the 2~3mm sized skin incision. Varicose clusters were extracted by the use of TriveTM esector(Smith & Nephe $w^{ R}$) system under transillumination. After the varisoce vein extraction, the operation area was compressed with surgical pad for bleeding control. The complication rate was 3.84% The mean number of incisions was 3.24 and mean operative time per limb was 65.9 minutes. The mean hospitalization was 1.86 days. The varicose vein extraction using transilluminated powered phlebectomy(TIPP) is a safe, efficacious and cosmetically satisfactory method. The procedure decreases the operating time and the number of incisions required to remove varicose clusters. Further evaluation and long term follow up will be necessary to determine the recurrence rate and long termcomplications.to determine the recurrence rate and long termcomplications.