• Title/Summary/Keyword: treatment device

Search Result 1,531, Processing Time 0.035 seconds

Analysis of dimensions and shapes of maxillary and mandibular dental arch in Korean young adults

  • Park, Su-Jung;Leesungbok, Richard;Song, Jae-Won;Chang, Se Hun;Lee, Suk-Won;Ahn, Su-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.321-327
    • /
    • 2017
  • PURPOSE. The aim of this study was to investigate dental arch dimensions and to classify arch shape in Korean young adults. MATERIALS AND METHODS. The sample included 50 Koreans with age ranging from 24 to 32 years. Maxillary and mandibular casts were fabricated using irreversible hydrocolloid and type III dental stones. Incisor-canine distance, $incisor-1^{st}$ molar distance, $incisor-2^{nd}$ molar distance, intercanine distance, $inter-1^{st}$ molar distance, and $inter-2^{nd}$ molar distance in both the maxillary and mandibular arch were measured using a three-dimensional measuring device. The dental arch was classified into three groups using five ratios from the measured values by the K-means clustering method. The data were analyzed with one-way analysis of variance. RESULTS. Arch lengths (IM2D, $incisal-2^{nd}$ molar distance) were 44.13 mm in the maxilla and 40.40 mm in the mandible. Arch widths (M2W, inter $2^{nd}$ molar width) were 64.12 mm in the maxilla and 56.37 mm in the mandible. Distribution of the dental arch form was mostly ovoid shape (maxilla 52% and mandible 56%), followed by the V-shape and the U-shape. The arch width for the U-shape was broader than for the other forms. CONCLUSION. This study establishes new reference data for dental arch dimensions for young Korean adults. The most common arch form is the ovoid type in the maxilla and mandible of Koreans. Clinicians should be aware of these references and classify arch type before and during their dental treatment for effective and harmonized results in Koreans.

Development of the Algorithm for On-line Dosimetry System for High Energy Radiation Treatment (고에너지 방사선치료용 on-line 선량측정시스템을 위한 알고리즘의 개발)

  • Wu, Hong-Hyun;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.207-218
    • /
    • 1997
  • Purpose: The objective of this study is to develop an algorithm for estimation of tumor dose using measured transmission dose as a part of the development of on-line dosimetry system. Materials and Methods: Data of transmission dose were measured under various FS, Tp and PCD with a special water phantom for 6 MV and 10 MV X-ray. SCD (source-chamber distance) was set to 150 cm. Measurements were conducted with a 0.125 cc ion chamber. Results: Using measured data and regression analysis, two algorithms were developed for estimation of expected reading for measured data. Algorithm 1 consisted of the quadratic function of PCD and the tertiary function of AlP (area-perimeter ratio). Algorithm 2 consisted of the tertiary function of log(A/P)and the tertiary function of PCD. Algorithm 2 required less data set and was more accurate in comparing expected and observed dose. Conclusion: Using the algorithm developed, transmission dose can be estimated for any exposure condition, i.e. any given Tp, PCD and FS with high accuracy. To complete this algorithm, further developments are needed regarding the beam modifying device, the tissue inhomogeneity and the irregular body surface.

  • PDF

TENSILE STRENGTH OF LASER WELDED-TITANIUM AND GOLD ALLOYS (티타늄과 금합금의 레이저 용접부의 인장강도)

  • Song, Yun-Gwan;Ha, Il-Soo;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.200-213
    • /
    • 2000
  • Lasers have given dentistry a new rapid, economic, and accurate technique for metal joining. Although laser welding has been recommended as an accurate technique, there are some limitations with this technique. For example, the two joining surfaces must have a tight-fitting contact, which may be difficult to achieve in some situations. The tensile samples used for this study were made from a custom-made pure titanium and type III gold alloy plates. 27 of 33 specimens were sectioned perpendicular to their long axis with a carborundum disk and water coolant. Six specimens remained and served as the control group. A group of 6 specimens was posed as butt joints in custom parallel positioning device with a feeler gauge at each of three gaps : 0.00, 0.25. and 0.50mm. All specimens were then machined to produce a uniform cross-sectional dimension, none of the specimens was subjected to any subsequent form of heat treatment. Scanning electron microscopy was performed on representative tested specimens at fractured surfaces in both the parent metal and the weld. Vickers hardness was measured at the center of the welds with a micropenetrometer using a force of 300gm for 15 seconds. Measurement was made at approximately $200{\mu}m\;and\;500{\mu}m$ deep from each surface. One-way analysis of variance (ANOVA) and Scheffe's test was calculated to detect differences between groups. The purpose of this study is to compare the strength and properties of the joint achieved at various butt Joint gaps by the laser welding of type III gold alloy and pure titanium tensile specimens in an argon atmosphere. The results of this study were as follows : 1. When indexing and welding pure titanium, there was no decrease in ultimate tensile strength as compared with the unsectioned alloys for indexing gaps of 0.00 to 0.50mm, although with increasing gap size may come increased distortion (p>0.05). 2. When indexing and welding type III gold alloy, there were significant differences in ultimate tensile strength among groups with weld gaps of 0.00mm, 0.25 and 0.50mm, and the control group. Group with butt contact without weld gap demonstrated a significant higher ultimate tensile strength than groups with weld gaps of 0.25 and 0.50mm (p<0.05). 3. When indexing and welding the different metal combination of type III gold alloy and pure titanium, there were significant differences in ultimate tensile strength between groups with weld gaps of 0.00, 0.25, and 0.50mm. However, the mechanical properties of the welded joint would become too brittle to be acceptable clinically (p<0.05). 4. The presence of large pores in the laser welded joint appears to be the most important factor in controlling the tensile strength of the weld in both pure titanium and type III gold alloy.

  • PDF

Study on Fiber Laser Annealing of p-a-Si:H Deposition Layer for the Fabrication of Interdigitated Back Contact Solar Cells (IBC형 태양전지 제작을 위한 p-a-Si:H 증착층의 파이버 레이저 가공에 관한 연구)

  • Kim, Sung-Chul;Lee, Young-Seok;Han, Kyu-Min;Moon, In-Yong;Kwon, Tae-Young;Kyung, Do-Hyun;Kim, Young-Kuk;Heo, Jong-Kyu;Yoon, Ki-Chan;Yi, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.430-430
    • /
    • 2008
  • Using multi plasma enhanced chemical vapor deposition system (Multi-PECVD), p-a-Si:H deposition layer as a $p^+$ region which was annealed by laser (Q-switched fiber laser, $\lambda$ = 1064 nm) on an n-type single crystalline Si (100) plane circle wafer was prepared as new doping method for single crystalline interdigitated back contact (IBC) solar cells. As lots of earlier studies implemented, most cases dealt with the excimer (excited dimer) laserannealing or crystallization of boron with the ultraviolet wavelength range and $10^{-9}$ sec pulse duration. In this study, the Q-switched fiber laser which has higher power, longer wavelength of infrared range ($\lambda$ = 1064 nm) and longer pulse duration of $10^{-8}$ sec than excimer laser was introduced for uniformly deposited p-a-Si:H layer to be annealed and to make sheet resistance expectable as an important process for IBC solar cell $p^+$ layer on a polished n-type Si circle wafer. A $525{\mu}m$ thick n-type Si semiconductor circle wafer of (100) plane which was dipped in a buffered hydrofluoric acid solution for 30 seconds was mounted on the Multi-PECVD system for p-a-Si:H deposition layer with the ratio of $SiH_4:H_2:B_2H_6$ = 30:120:30, at $200^{\circ}C$, 50 W power, 0.2 Torr pressure for 20 minutes. 15 mm $\times$ 15 mm size laser cut samples were annealed by fiber laser with different sets of power levels and frequencies. By comparing the results of lifetime measurement and sheet resistance relation, the laser condition set of 50 mm/s of mark speed, 160 kHz of period, 21 % of power level with continuous wave mode of scanner lens showed the features of small difference of lifetime and lowering sheet resistance than before the fiber laser treatment with not much surface damages. Diode level device was made to confirm these experimental results by measuring C-V, I-V characteristics. Uniform and expectable boron doped layer can play an important role to predict the efficiency during the fabricating process of IBC solar cells.

  • PDF

The Special Plan of the Traffic Accident Treatment in the Emergency Car Concerning Fire Fighting (소방관련 긴급자동차의 교통사고처리 특례방안)

  • Jeng, Gi-Sung
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.20-29
    • /
    • 2008
  • The traffic accident of Fire engine takes place very much, compared with that of the past. The reason is that there is a lot of the increase of the demand in the fire, rescue, first aid, and the public request. Also, because the Fire engine should go out at the place of the accident very quickly, it should inevitably violate the traffic regulations. Therefore, this is due to the traffic accident. Despite the urgent situation in the infringement motive of traffic regulations, the outbreak of the traffic accident does not vary largely from the degree of the disadvantage. Accordingly, a fire officer should take charge of his social and economic disadvantage by himself. In this situation, a fire officer has no choice but to start moving passively not to be afflicted with his own disadvantage. Most of the situations concerning the fire fighting are the ones to be controlled urgently. Nevertheless, because of the disadvantage of the traffic accident, passive mobilization of the fire fighting equipment is the heavy burden of all the people of the nation. Therefore, Special institutional safety device should be ready for the protection of the life and property of all people. The special law concerning the processing in the accident of the emergency car needs to be revised. By establishing this special law, the government should not provide the officer who drives the fire engine with the disadvantage caused by traffic accident.

Assessment of Prognostic Value of "Neutrophil to Lymphocyte Ratio" and "Prognostic Nutritional Index" as a Sytemic Inflammatory Marker in Non-small Cell Lung Cancer

  • Kos, Fahriye Tugba;Hocazade, Cemil;Kos, Mehmet;Uncu, Dogan;Karakas, Esra;Dogan, Mutlu;Uncu, Hikmet Gulsen;Ozdemir, Nuriye;Zengin, Nurullah
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3997-4002
    • /
    • 2015
  • Background: Systemic inflammatory response was shown to play an important role in development and progression of many cancer types and different inflammation-based indices were used for determining prognosis. We aimed to investigate the prognostic effects of neutrophil to lymphocyte ratio (NLR) and prognostic nutritional index (PNI) in patients with non-small cell lung cancer (NSCLC). Materials and Methods: NSCLC patients diagnosed in our institution were retrospectively reviewed. Demographic and clinicopathologic characteristics were recorded. NLR and PNI was calculated before the application of any treatment. Results: A total of 138 patients were included in the study. Patients were divided into two groups according to NLR (<3.24 or ${\geq}3.24$) and PNI (<49.5 or ${\geq}49.5$). While median overall survival was 37.0 (95% CI 17.5-56.5) months in the group with low NLR, it was calculated as 10.0 (95%CI 5.0-15.0) months in the group with high NLR (p<0.0001). While median overall survival was 7.0 (95%CI 3.5-10.5) months in the group with low PNI, it was calculated as 33.0 (95% CI 15.5-50.4) months in the group with high PNI (p<0.0001). Stage, NLR and PNI levels were evaluated as independent risk factors for overall survival for all patients in multivariate analysis (p<0.0001, p=0.04 and p<0.001, respectively). Conclusions: NLR (${\geq}3.24$) and PNI (<49.5) at diagnosis is an independent marker of poor outcome in patients with NSCLC. NLR and PNI is an easily measured, reproducible prognostic tests that could be considered in NSCLC patients.

Study on the Smart 1RM System Development and Effect Verification for Health Improvement and Management of National Healthcare (국민 건강관리 및 체력증진을 위한 스마트 1RM 시스템 개발 및 효과 검증에 관한 연구)

  • Woo, Kyung-Min;Shin, Mi-Yeon;Yu, Chang-Ho
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.12 no.1
    • /
    • pp.53-62
    • /
    • 2018
  • In this study, we developed a smart 1RM system for national health management and physical fitness, which enables quantitative 1RM measurement in various types of exercise using digital pulley technology, and to test the effect on training by using it. We developed the smart 1RM system, which is composed of portable muscle strength measuring device, Bluetooth communication based mobile phone data transmission and circuit diagram, and height adjustable system body. We recruited the 30 participants with 20th aged and divided into training and non-performing groups with 15 participants randomly. The participants performed 5 sets of elbow, lumbar, knee extension / flexion 10 times using smart 1RM system and the experimental period was 3 days a week for a total of 8 weeks. The experimental results showed that the maximum strength of the elbow, lumbar, and knee joints was significantly improved before and after maximal muscle strength training in the training group. Oxygen intakes during 1RM exercise mode showed 10.91% than endurance. To verify the validity of the smart 1RM maximal strength data, the reliability was 0.895 (* p <0.00). This study can be applied to the early rehabilitation treatment of the elderly and rehabilitation patients more quantitatively using the national health care.

Intercalary Tricortical Iliac Bone Graft in the Surgical Treatment of Nonunion of Midshaft Clavicular Fractures (쇄골 간부 불유합에서의 개재 삼면피질 장골 이식술)

  • Cho, Chul-Hyun;Jang, Hyung-Gyu
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.32-36
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the radiologic and clinical outcomes after intercalary tricortical iliac bone graft with plate fixation for the nonunion of midshaft clavicular fractures. Material and Methods: Between September 2007 and May 2011, 10 patients who were treated by the intercalary tricortical iliac bone graft, with plate fixation for clavicle nonunion, were studied. The mean follow-up period was 30.7 (12~57) months. After the sclerotic bone was excised to the bleeding cortical bone, we interposed the tricortical iliac bone to provide structural support and restore clavicle length, and then fixed the plate and screws. The radiologic outcomes on the serial plain radiographs and clinical outcomes, according to UCLA, ASES and Quick DASH scores, were analyzed. Results: Bony union was obtained in all cases (100%) and the average union time was 18.4 (14~24) weeks. The average respective UCLA and ASES scores improved from 16.7 and 52.1 preoperatively to 27.4 and 83.6 postoperatively (p<0.05). The average Quick DASH score was 40.5, at the final follow-up. Complications were 2 shoulder stiffness, and one case had removal of device and arthroscopic surgery at 11 months, postoperatively. There were no implant failure or infection. Conclusion: Intercalary tricortical iliac bone graft, with plate fixation for the nonunion of midshaft clavicular fractures, is a good option that can provide structural support and restore clavicle length, as well as high union rate.

Stabilization Performance Evaluation of Filter(pH) Using Ionic Water Generator (이온수기 필터(pH)의 안정화 성능평가)

  • Nam, Sangyep;Kwon, Yunjung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.199-205
    • /
    • 2015
  • This study is about ionic water generator filter Recently, a lot of people feel deep interest in health and drinking water. And there are various types of water. Ionic water generator is a system with special function, and can be classified as a medical device and should be manufactured after approval from the Food and Drug Administration. Basically ionized water is different from the packaged and stored water. When the tap water or ground water passes through the various filters of ionic water generator, it turns to the purified water of pH7 ~ 7.5 and we can electrolyze that water into anion and cation by diaphragm. And in negative electrode side, we can get alkaline water with calcium ($Ca^+$), potassium ($K^+$), magnesium ($Mg^+$), sodium ($Na^+$) for body. In general, we can change pH value from 5 to 9 of ionizer by controlling the level of electrolysis voltage in the ionizer. In general, 1stage (pH8), 2stage (pH8.5), 3stage (pH9), 4stage (pH9.5) are used as the alkaline ionized water, -1Stage (pH6.0), -2 stage (pH5.0) are used as the acidic water. But in early stage, the water that passed through filter was weakly alkaline water and that was problem. Therefore, when filter condition is stable, the pH and ORP value of water is different with the early one. the initial setting pH value of the ionizer was confirmed that changes significantly. In order to resolve this problem we need to wash filter for some period time and neutralize by acidification treatment of the filter.

CFD Analysis on the Hydro Turbine by the Existence of Blade Holes (블레이드 타공에 따른 수차의 유동해석)

  • Park, Yoo-Sin;Kim, Ki-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.675-680
    • /
    • 2017
  • Considering that most sewage treatment facilities have a water head of less than 2.0 m and a constant flow rate, the development of a small hydro power generation device capable of maintaining stable power generation and efficiency is urgently needed. In this study, a numerical analysis using the CFD code was carried out to develop a drag force type vertical axis hydro turbine for the improvement of the production efficiency of small-scale hydro energy underlow flow velocity conditions. The blade pressure changes and internal flows were analyzed in the presence or absence of hydro turbine blade holes at a flow velocity of less than 2.0 m/s. The pressure distribution of the hydro turbine blades with holes was found to be about 5.1 % lower than that of the hydro turbine blades without holes. The analysis of the internal flow around the water tank and hydro turbine blade revealed that the flow velocity varied with the vector distribution and that the flow velocity of the hydro turbine blades with holes was 5.6 % less than that of the hydro turbine blades without holes. It is believed that forming a hole in the blade may be helpful for its structural safety.