Developing Thermal Treatment Device for Pain Relief of Prostatism Patient (전립선 비대증 환자의 배뇨 통증 완화를 위한 개인용 전립선 온열 치료기 개발)

  • Park, Sung Yun;Kim, Sung Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.210-212
    • /
    • 2014
  • The prostatic disease is one of common disease on andropathy. The prostatism, one disease of prostatic disease. is leaded a urination pain. To treat the this disease, Laser surgery is usually used with medicine treatment. Recently, the method of thermal therapy is rapidly increasing. Then we made the personal thermal treatment device for decreasing urination pain. And we have good performance data using pig skin.

Development of Electronic Portal Imaging Device and Treatment Position Verification for Fractionated Stereotatic Radiotherapy

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Chilgoo Byun;Hong, Seung-Hong;Rhee, Soo-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.446-449
    • /
    • 2002
  • The video based electronic portal imaging device (EPID), which could display the portal image in near real time, was implemented to verify treatment position error in FSRT(Fractionated Stereotatic Radiation Therapy) instead of a portal film. Also, Developed FSRT system was composed of the stereotactic frame, frame mounting system and collimator cones. The verification of treatment position is very crucial in special therapies like FSRT. In general, the FSRT uses high dpse rate at small field size for treating small intracranial lesions. To evaluate quantitative positioning errors in FSRT, we used the first FSRT image as reference image and obtained the second FSRT image that was moved 2mm intentionally and detected intracranial contours after image processing. The generated 2mm error could be verified by overlapping only contours of two images. Through this study, the radiation treatment efficiency could be improved by performing precise radiation therapy with a developed video based EPID and FSRT.

  • PDF

Emphysema following air-powder abrasive treatment for peri-implantitis

  • Lee, Sung-Tak;Subu, Malavika Geetha;Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.12.1-12.5
    • /
    • 2018
  • Background: Subcutaneous emphysema refers to swelling caused by the presence of air or gas in the interstices of loose connective tissue. In the head and neck area, it may follow the fascial planes and is characterized by sudden swelling, crepitus on palpation, infrequent pain, and air emboli on radiography. It usually occurs as a complication in dental treatment. Some reports have described subcutaneous emphysema caused by dental procedures; however, severe emphysema related to peri-implantitis after treatment has not been documented. Accordingly, the current report describes a rare case of subcutaneous cervical emphysema resulting from the use of an air-powder abrasive device to treat peri-implantitis. Case presentation: Based on a review of the existing literature and the present case, nine cases of subcutaneous emphysema due to air-powder abrasive device have been reported. In most cases, the emphysema resolved over time after treatment with prophylactic antibiotics; among these, two were related to peri-implantitis management. Conclusion: Considering the frequent use of air-powder abrasive devices to treat peri-implantitis, the potential risk of iatrogenic emphysema related to this procedure needs to be addressed more extensively.

Effect of Heat Treatment on Fatigue Life of the Power Train Part (파워트레인 부품의 피로수명에 미치는 열처리의 영향)

  • Hur, M.D.;Shim, T.Y.;Lee, K.O.;Yu, G.B.;Kang, S.S.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.4
    • /
    • pp.203-209
    • /
    • 2009
  • Dual mass flywheel is the newly developed flywheel system which reduces the noise and vibration and make a better and comfortable ride of cars by adding inertia mass and damping device. However, verification of performance for this system should be carried out since this system is under developing status in our country. Especially, the durability for each part of this system should be guaranteed. Durable properties of driver plate which is the key component of dual mass flywheel were first investigated both in the raw (SCM435 in JIS) and heat-treated material. In addition, fatigue life analysis of driver plate was preformed in the real condition and the results were verified by comparison with the results of rig test.

Study on Electrical Characteristic Improvement of PVP-IZO TFT Prepared by Solution Process Using UV-O3 Treatment (용액공정으로 제작한 PVP-IZO TFT의 UV-O3 처리를 통한 전기적 특성 향상 연구)

  • Kim, Yu Jung;Jeong, Jun Kyo;Park, Jung Hyun;Jung, Byung Jun;Lee, Ga Won
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.2
    • /
    • pp.66-69
    • /
    • 2017
  • In this paper, solution based Indium Zinc Oxide thin film transistors (IZO TFTs) were fabricated with PVP gate dielectric. To enhance the electrical properties, UV-O3 treatment is proposed on solution based IZO TFTs. The gate leakage current and interface trap density is compatible with conventional ZnO-based TFT with inorganic gate insulator. Especially, the UV-treated device shows improved electrical characteristics compared to the untreated device. These results can be explained by X-ray photoelectron spectroscopy (XPS) analysis, which shows that the oxygen vacancy of UV-O3 treatment is higher than that of no treatment.

  • PDF

Clinical Evaluation of the Effects of Far-Infrared Hot & Cool Mask (BBSkinplus) for Skin Care (원적외선냉온마스크(BBSkinplus)의 피부미용개선 임상연구)

  • Yoo, Jae-seob;Barng, Kee-jung;Son, Chang-gue
    • Journal of Fashion Business
    • /
    • v.25 no.2
    • /
    • pp.51-62
    • /
    • 2021
  • This study evaluated the cosmetic effects of a far-infrared hot and cool mask (BBSkinplus) on face skin moisturization, whitening, and wrinkles using a randomized clinical trial. Forty female participants (mean age 47.7 ± 4.6 years) were allocated into the treatment group (BBSkinplus treatment and lotion application twice a day) or the control group (only lotion application twice a day), and moisture, brightness, and wrinkles were measured at 0, 1 and 2 weeks. The average values of each measurement were changed significantly by BBSkinplus treatment compared to the control group. At the 2-week treatment time point, the statistical differences in improvement rates between the two groups were significant at 8.7% vs. 3.9% for moisture (p < 0.01), 0.7% vs. 0.4% for brightness (p < 0.01), and -3.1% vs. 0.0% as Ra and -6.3% vs. 1.5% as R3z for wrinkles (p < 0.05), respectively. No notable complaint was reported regarding any kind of adverse effects such as erythema, itching, or burning. This clinical data support the potential of BBSkinplus as a home beauty device providing moisturizing, whitening, and anti-wrinkle effects on the face.

Multiple telescopic stenting versus single flow diverter for the treatment of vertebral artery dissecting aneurysm

  • Min-Seok Woo;Wonsoo Son;Dong-Hun Kang;Jaechan Park;Myungsoo Kim
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.26 no.3
    • /
    • pp.284-292
    • /
    • 2024
  • Objective: Reconstruction methods, including stent-assisted coiling, multiple telescopic stents, and flow diverters, are preferred modalities for the treatment of unruptured vertebral artery dissecting aneurysms (VADAs). We aimed to compare the clinical outcomes between two reconstructive flow diversion techniques: single flow diverter (FD) device and multiple telescopic stenting (TS). Methods: We retrospectively reviewed the clinical data of 39 patients with unruptured VADAs. Of these, 17 patients were treated with multiple TS and 22 with a single FD device. Aneurysm characteristics and clinical outcomes were compared between the two groups. Results: All aneurysms included in this study successfully achieved flow diversion, regardless of the treatment modality and duration. However, the mean procedure duration to complete the diversion was shorter in the FD group. Subgroup analysis in TS group showed that there were no significant clinical differences between the low-profile visualized intraluminal support and Enterprise stents, except for the mean procedure duration. Conclusions: Both the single FD and multiple TS methods showed excellent angiographic and clinical outcomes in the treatment of unruptured VADAs. However, single FD required a shorter procedure duration and was associated with faster achievement of complete flow diversion.

Identification of operating parameters in auto-discharging filter system for treatment of urban storm water (자동방류가 가능한 여과형 비점오염처리장치의 운전인자 도출)

  • Kim, Sun-Hee;Gwon, Eun-Mi;Pak, Sung-Soon;Joh, Seong-Ju;Lim, Chea-Hoan;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.377-386
    • /
    • 2010
  • To identify operating parameters of the up-flow filtering system, which is available to discharge filtering residue after the rain, developed for treatment of urban storm runoff, lab scale test was carried out. Removal efficiency of SS was 68.7%, 62.2%, and 58.6% at the area roading rate of 2.46m/h, 4.68m/h, and 10m/h, respectively, filtering device is desirable to operate at the lower than 4.68m/h of area roading rate to get higher level of 60% SS removal efficiency. The removal efficiency of SS was 57.1% ~ 68.7% at the raw water SS of 100mg/L ~ 600mg/L, and the SS in treated water was maintained at the constant level through the elapsed time. It is indicate that filtering device can guarantee a certain level of effluent water quality at various raw water quality. The removal efficiency of SS to the depth of filter media was 68.3%, 78.6% at the filter depth of 10 cm, 20cm respectively. The final treated water quality was showed 30.2mg/L of CODMn, 1.60mg/L of TN and 0.25mg/L of TP. The average removal efficiencies by filtering device developed in this research were recorded slightly lower levels than other research. The main reason of these results were the first, the filter depth of the media used in this test was shallow, the second, the kind of filter media in discharge port of residue. More research to kind of filter media, filter packing rate, select of media for residue discharge port should be go on to produce optimum operating condition. The result of this study would be valuable for the application of filtration device to control of urban storm water.

Feasibility Study of Robotics-based Patient Immobilization Device for Real-time Motion Compensation

  • Chung, Hyekyun;Cho, Seungryong;Cho, Byungchul
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.117-124
    • /
    • 2016
  • Intrafractional motion of patients, such as respiratory motion during radiation treatment, is an important issue in image-guided radiotherapy. The accuracy of the radiation treatment decreases as the motion range increases. We developed a control system for a robotic patient immobilization system that enables to reduce the range of tumor motion by compensating the tumor motion. Fusion technology, combining robotics and mechatronics, was developed and applied in this study. First, a small-sized prototype was established for use with an industrial miniature robot. The patient immobilization system consisted of an optical tracking system, a robotic couch, a robot controller, and a control program for managing the system components. A multi speed and position control mechanism with three degrees of freedom was designed. The parameters for operating the control system, such as the coordinate transformation parameters and calibration parameters, were measured and evaluated for a prototype device. After developing the control system using the prototype device, a feasibility test on a full-scale patient immobilization system was performed, using a large industrial robot and couch. The performances of both the prototype device and the realistic device were evaluated using a respiratory motion phantom, for several patterns of respiratory motion. For all patterns of motion, the root mean squared error of the corresponding detected motion trajectories were reduced by more than 40%. The proposed system improves the accuracy of the radiation dose delivered to the target and reduces the unwanted irradiation of normal tissue.

LED Fiber-Optic Lighting Devices Developed for Medical Assistance for the Local Treatment Retractor (국부치료를 위한 Retractor용 LED 광섬유 의료보조조명 장치 개발)

  • Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.666-671
    • /
    • 2016
  • This paper introduces a device providing close local lighting to the affected part, where the operation-purpose astral lamp alone cannot shed light directly, in an operation room of hospitals or clinics, which helps clinical doctors perform safe treatment of the affected part deep inside a human body. This medical assisting lighting is a device necessary to prevent fatal operation failures, which can occur with minute operation processes, such as tumor removal or angiorrhaphy. The components, such as the light source and power supply were designed to be low power consuming and small in size, have a narrow angle lens was used to increase the light spreading effect and focused illumination. The end-caps of the light transmission device using an optical cable and the lighting device were designed in the waterproof type to enable disinfection of these devices after use for the next patients. According to the measurement of the light source properties made after development of the retractor lighting device, the illumination intensity was 490 lux, the brightness was $11,550cd/m^2$, general color rendering index was 78, color temperature was 11,000K, and the intensity distribution was even, which were confirmed to be adequate for medical assisting local lighting.