• Title/Summary/Keyword: treatment device

Search Result 1,531, Processing Time 0.034 seconds

Hair Loss Treatment Using Erbium:YAG Fractional Laser with Hair Growth-promoting Solution

  • Ahn, Dong Hyun
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.176-180
    • /
    • 2021
  • Several methods have been used to treat androgenetic hair loss, ranging from hair transplants to finasteride and minoxidil. Sometimes platelet-rich plasma injection therapy may be used to increase the satisfaction of patients who come to the hospital. However, some patients are sensitive to pain and are subjected to the inconvenience of requiring treatment after each blood sampling. The author had reported the effects of using a hair growth-promoting solution and JetpeelTM in parallel with a painless hair loss treatment method. However, the author was interested in more effective methods for patients with M-shaped or vertex hair loss who do not want to take medications or undergo hair transplant. In addition to the existing light-emitting diode therapy and electromagnetic field treatment, the author has made considered attempts to use various laser wavelength bands. However, the equipment for these methods can be expensive and are not suitable for patients who emphasize on cost-effectiveness. Therefore, the author used an existing reported method and a device based on the fractional erbium:YAG laser to provide the hair growth-promoting solution in parallel. The author chose a fractional 2940 nm-based laser device as a medium that could efficiently increase the growth phase, reduce the catagen phase, and facilitate intradermal product and drug delivery. As a result, there was a therapeutic benefit without any significant side effects such as redness and itching. Among the patients, the author reported the effects of the treatment on one patient with frontal M-shaped, mid, and vertex hair loss.

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

A survey about the use of oral hygiene device and awareness some of the middle age people (일부 중·장년층의 구강위생용품 인지와 사용실태)

  • Jung, Gi-Ok
    • Journal of Korean society of Dental Hygiene
    • /
    • v.9 no.4
    • /
    • pp.580-592
    • /
    • 2009
  • Objectives : This study had been performed for Respondents who live in Daegu and Kyungbuk province Age group of 30 to 50 years old. Methods : The oral health state and oral heath care, dental treatments about the use of oral hygiene devices were obtained through self-administering questionnaires from 2 to 31, January, 2009. Results : 1. The toothpick was well known for respondents and automatic brush, gargle, dental floss were practically used. 2. 57.1% of man know oral hygiene device, they know more about oral hygiene device if they have higher degree, and they use more if they are older than others. 3. 55.5% of respondents who think their oral health condition is not healthy enough recognize oral hygiene device, 77.5% of respondents who visited dental clinic around six month recognize oral hygiene device. 82.4% of respondents who had been follow-up. 86.1% of respondents who think their oral health state is good enough doesn't use oral hygiene device, oral hygiene device was used more for respondents who visited dental clinic frequently. 47.1% of respondents who visited dental clinic periodically use oral hygiene device. 4. Respondents who experience implant recognize more about oral hygiene device and periodontal Tx, orthodontics problem, preservative treatment were next. 5. 60.0% of respondents who were educated tooth brushing method recognize it. Oral hygiene device was frequently used if tooth brushing time were increased. 26.4% of respondents who were changed their tooth brushing method used oral hygiene device. Conclusions : Their recognition level was practically low whose age is around 30 to 50. Their oral hygiene device use ratio is higher then others who were educated tooth brush method so that I think we need to recommend for use oral hygiene device and use method.

  • PDF

Transdermal Delivery of FITC-Ovalbumin with Microneedle System (마이크로 피부침을 이용한 FITC-OVA의 경피흡수)

  • Jang, Woo-Young;Lee, Chang-Rae;Seo, Seong-Mi;Lee, Bong;Kim, Moon-Suk;Khang, Gil-Son;Lee, Han-Gu;Lee, Hai-Bang
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.6
    • /
    • pp.403-409
    • /
    • 2005
  • For transdermal delivery of large molecular drugs such as vaccine and protein drugs, novel microneedle treatment device with roll was designed. The roll dimension is 1.43 cm diameter and 2.8 cm perimeter. Total number of microneedle on the roll is 3,360 with $230\;{\mu}m$ height and $740\;{\mu}m$ distance. The pore with $150\;{\mu}m$ depth and $35\;{\mu}m$ diameter on the skin was made by the designed microneedle device. This system could be achieved without pain. The permeation rates of FITC labelled ovalbumin (FITC-OVA, molecular weight: 45,000 g/mol) as a model protein were determined by modified Franz diffusion cells using skins of hairless mice or SD rats which were treated by using microneedle device two or four times. The average penetration fluxes of model protein increased from 674 to $872\;{\mu}g/cm^{2}{\cdot}hr$ as the number of treatment to make pore increased from two to four times. In conclusion, we confirmed the possibility of using the designed microneedle treatment device for transdermal delivery of the large molecular drugs.

Study on the Electrical Characterization of Inverted Staggered Pentacene Thin Film Transistor using Hydrogen Plasma Treatment (수소 플라즈마 처리를 이용한 역스테거드형 펜타센 트랜지스터의 전기적 특성 향상에 대한 연구)

  • 장재원;이주원;김재경;김영철;주병권
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.11
    • /
    • pp.961-968
    • /
    • 2003
  • In order to reach the high electrical quality of organic thin film transistors (OTFTs) such as high mobility and on-off current ratio, it is strongly desirable to study the enhancement of electrical properties in OTFTs. Here, we report the novel method of hydrogen plasma treatment to improve electrical properties in inverted staggered OTFTs based on pentacene as active layer. To certify the effect of this method, we compared the electrical properties of normal device as a reference with those of device using the novel method. In result, the normal device as a reference making no use of this method exhibited a field effect mobility of 0.055 $\textrm{cm}^2$/Vs, on/off current ratio of 10$^3$, threshold voltage of -4.5 V, and subthreshold slope of 7.6 V/dec. While the device using the novel method exhibited a field effect mobility of 0.174 $\textrm{cm}^2$/Vs, on/off current ratio of 10$\^$6/, threshold voltage of -0.5 V, and subthreshold slope of 1.49 V/dec. According to these results, we have found the electrical performances in inverted staggered pentacene TFT owing to this method are remarkably enhanced. So, this method plays a key role in highly improving the electric performance of OTFTs. Moreover, this method is the first time yet reported for any OTFTs.

Correct Posture Guidance System using 3-axis Acceleration Sensor for Scoliosis Patient (3축 가속도 센서를 이용한 자세 교정 유도 시스템)

  • An, Yang-Soo;Kim, Keo-Sik;Seo, Jeong-Hwan;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.220-224
    • /
    • 2010
  • In this study, we designed a device for consecutively observing position, utilizing 3-axises acceleration sensor. This method offer to check his or her wrong position and developed could to help derived a position appliance. And, we developed a Cobb's angle value in three dimensional using 3-axises acceleration sensor. A proposed device with integrated accelerometers, which can detect postural changes in terms of curvature variation of the spine in the sagittal and coronal planes, has been developed with intention to facilitate posture training. The proposed device was evaluated with 3 normal subjects daily activities. We evaluated the performance of our designed device as calculating the correlation coefficients and mean errors between the angle measured by an electro-goniometer and that estimated by a gravity accelerometer and verified the accuracy and sensitivity. The results showed that the angle obtained from the proposed device revealed a linear characteristic at the range of $\pm60^{\circ}$(correlation coefficient 0.99, error range $\pm2^{\circ}$). We demonstrated that our device could detect the changes of the motion in upper trunk accurately. Also, our device showed good potential for treatment of the patients with scoliosis and prevention of the unbalance position during a daily life.

Brace Compression for Treatment of Pectus Carinatum

  • Jung, Joonho;Chung, Sang Ho;Cho, Jin Kyoung;Park, Soo-Jin;Choi, Ho;Lee, Sungsoo
    • Journal of Chest Surgery
    • /
    • v.45 no.6
    • /
    • pp.396-400
    • /
    • 2012
  • Background: Surgery has been the classical treatment of pectus carinatum (PC), though compressive orthotic braces have shown successful results in recent years. We propose a non-operative approach using a lightweight, patient-controlled dynamic chest-bracing device. Materials and Methods: Eighteen patients with PC were treated between July 2008 and June 2009. The treatment involved fitting of the brace, which was worn for at least 20 hours per day for 6 months. Their degree of satisfaction (1, no correction; 4, remarkable correction) was measured at 12 months after the initiation of the treatment. Results: Thirteen (72.2%) patients completed the treatment (mean time, $4.9{\pm}1.4$ months). In patients who completed the treatment, the mean overall satisfaction score was $3.73{\pm}0.39$. The mean satisfaction score was 4, and there was no recurrence of pectus carinatum in patients who underwent the treatment for at least 6 months. Minimal recurrence of pectus carinatum after removal of the compressive brace occurred in 5 (38.5%) patients who stopped wearing the compressive brace at 4 months. Conclusion: Compressive bracing results in a significant improvement in PC appearance in patients with an immature skeleton. However, patient compliance and diligent follow-up appear to be paramount for the success of this method of treatment. We currently offer this approach as a first-line treatment for PC.

Property change of organic light-emitting diodes due to a SAM treatment of the ITO surface (ITO 표면의 SAM형 습식 개질에 의한 유기 발광 소자의 특성 변화)

  • Na, Su-Hwan;Joo, Hyun-Woo;An, Hui-Chul;Kim, Tae-Wan;Song, Min-Jong;Lee, Ho-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.314-315
    • /
    • 2008
  • We have studied a property change of organic light-emitting diodes (OLED)s due to a surface reformation of indium-tin-oxide(ITO) substrate. An ITO is widely used as a transparent electrode in light-emitting diodes, and the OLEDs device performance is sensitive to the surface properties of the ITO. The ITO surface reformation could reduce the Schottky barrier at the ITO/organic interface and increase the adhesion of the organic layer onto the electrode. We have studied the characteristics of OLEDs with a treatment by a wet processing of the ITO substrate. The self-assembled monolayer(SAM) was used for wet processing. The characteristics of OLEDs were improved by SAM treatment of an ITO in this work. The OLEDs with a structure of ITO/TPD(50nm)/$Alq_3$(70nm)/LiF(0.5nm)/Al(100nm) were fabricated, and the surface properties of ITO were investigated by using seneral characterization techniques. Self-assembled monolayer introduced at the anode/organic interface gave an improvement in turn-on voltage, luminance and external quantum efficiency compared to the device without the SAM layer. SAM-treatment time of the ITO substrate was made to be 0/10/15/20/25min. The current efficiency of the device with 15min. treated SAM layer was increased by 3 times and the external quantum efficiency by 2.6 times.

  • PDF

Correction of a Wide Alveolar Cleft with Reverse L osteotomy and Liou Alveolar Distractor (역 L 형 절골술과 Liou 신연기를 이용한 넓은 치조열의 교정)

  • Lee, Myung Chul;Lew, Dae Hyun;Park, Beyoung Yun;Kwon, Soon Man
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.445-449
    • /
    • 2009
  • Purpose: A successful surgical treatment for a wide alveolar cleft with bone graft is difficult to achieve due to several factors such as the limitation of gingivoperiosteal flap, the presence of large scar tissues, and the poor blood circulation. To overcome these problems, alveolar distraction osteogenesis using Liou alveolar distraction device was applied. We analyzed the consequences of this surgical treatment. Method: Between 2006 January and 2007 August, we have conducted analysis on the methods and consequences of Liou alveolar distraction osteogenesis for 6 patients. The age of patients was 12 years and 6 months in average. The follow up period was 19 months in average. The Reverse L osteotomy followed by the placement of the Liou alveolar distraction device was performed. After serial distraction, the distractor was removed after 5 months of the process of osteogenesis, and the result was analyzed using the computed tomography and the x-ray films of the alveolar bone and the teeth. Results: The alveolar cleft with 12.5 mm in average width was filled with 8.5 mm of newly formed bone tissue in average width after 5 months of osteogenesis. Among the 6 cases, 5 required the additional bone graft and 1 case only required the gingivoperioplasty. The newly formed bone tissues did not show any signs of bone resorption. However, a considerable degree of teeth displacement was shown. Conclusion: For the alveolar cleft too wide to be reconstructed by a general bone graft, it is strongly recommended to perform the reverse L osteotomy of the cleft side with Liou alveolar distraction device to initiate the alveolar osteogenesis. However, the migrated teeth showed some degree of relapse, thus, the orthodontic treatment is essential following the distraction osteogenesis treatment.