• 제목/요약/키워드: transport temperature

검색결과 1,511건 처리시간 0.031초

Experimental Evaluation of the Thermal Integrity of a Large Capacity Pressurized Heavy Water Reactor Transport Cask

  • Bang, Kyoung-Sik;Yang, Yun-Young;Choi, Woo-Seok
    • 방사성폐기물학회지
    • /
    • 제20권3호
    • /
    • pp.357-364
    • /
    • 2022
  • The safety of a KTC-360 transport cask, a large-capacity pressurized heavy-water reactor transport cask that transports CANDU spent nuclear fuel discharged from the reactor after burning in a pressurized heavy-water reactor, must be demonstrated under the normal transport and accident conditions specified under transport cask regulations. To confirm the thermal integrity of this cask under normal transport and accident conditions, high-temperature and fire tests were performed using a one-third slice model of an actual KTC-360 cask. The results revealed that the surface temperature of the cask was 62℃, indicating that such casks must be transported separately. The highest temperature of the CANDU spent nuclear fuel was predicted to be lower than the melting temperature of Zircaloy-4, which was the sheath material used. Therefore, if normal operating conditions are applied, the thermal integrity of a KTC-360 cask can be maintained under normal transport conditions. The fire test revealed that the maximum temperatures of the structural materials, stainless steel, and carbon steel were 446℃ lower than the permitted maximum temperatures, proving the thermal integrity of the cask under fire accident conditions.

고온 나트륨 히트파이프에서 열이송 조건에 따른 열전달 특성에 대한 실험 연구 (An Experimental Study on the Heat Transfer Characteristics of a High-temperature Sodium Heat Pipe Depending on the Thermal Transport Conditions)

  • 박철민;부준홍;김진수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2340-2345
    • /
    • 2008
  • Cylindrical stainless-steel/sodium heat pipe for a high-temperature application was manufactured and tested for transient and steady-state operations. Two layers of Stainless-steel screen mesh wick was inserted as a capillary structure. The outer diameter of the heat pipe was 12.7 mm and the total length was 250 mm. As thermal transport conditions, the effective transport length, the heat flux, the tilt angle and the operating temperature were varied. The heat was supplied by an electric furnace up to 1 kW and the cooling was performed by forced convection of air. The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and vapor temperature. Typical range of the total thermal resistance was as low as $0.036^{\circ}C/W$ at $175.8\;kW/m^2$ of heat flux and $700^{\circ}C$ of operating temperature.

  • PDF

사용후핵연료 운반용기 덮개 내부 열전달 해석 (Heat Transfer Analysis around Transport Cask under Transport Hood)

  • 이동규;박제호;정인수;김태만;윤정현
    • 방사성폐기물학회지
    • /
    • 제9권3호
    • /
    • pp.161-167
    • /
    • 2011
  • 사용후핵연료 운반용기 표면온도가 $85^{\circ}C$를 초과할 경우, 대인용 보호막(Personnel Barrier) 또는 운반용 덮개(Transport Hood)를 설치하여 운반 중 운반용기 표면에 사람이 직접 접근할 수 없도록 하여야 한다. 운반용 덮개가 설치된 경우, 열적 안전성 평가의 한 가지 경우인 정상조건 열해석 시, 외부환경 경계조건(환경온도 및 외부복사온도)으로 적용하기 위해서 운반용 덮개 내부 열 환경 조건(내부 공기온도 및 운반용 덮개 표면온도)을 계산해야 한다. 따라서 본 연구에서는 운반용 덮개 내부 공기온도 및 표면온도를 계산하기 위한 해석적 방법 및 열전달 특성에 대한 분석을 수행하였고 CFD 해석 결과와 비교를 통해 타당성을 검증하였다.

Fabrication and Electrical Transport Characteristics of All-Perovskite Oxide DyMnO3/Nb-1.0 wt% Doped SrTiO3 Heterostructures

  • Wang, Wei Tian
    • 한국재료학회지
    • /
    • 제30권7호
    • /
    • pp.333-337
    • /
    • 2020
  • Orthorhombic DyMnO3 films are fabricated epitaxially on Nb-1.0 wt%-doped SrTiO3 single crystal substrates using pulsed laser deposition technique. The structure of the deposited DyMnO3 films is studied by X-ray diffraction, and the epitaxial relationship between the film and the substrate is determined. The electrical transport properties reveal the diodelike rectifying behaviors in the all-perovskite oxide junctions over a wide temperature range (100 ~ 340 K). The forward current is exponentially related to the forward bias voltage, and the extracted ideality factors show distinct transport mechanisms in high and low positive regions. The leakage current increases with increasing reverse bias voltage, and the breakdown voltage decreases with decrease temperature, a consequence of tunneling effects because the leakage current at low temperature is larger than that at high temperature. The determined built-in potentials are 0.37 V in the low bias region, and 0.11 V in the high bias region, respectively. The results show the importance of temperature and applied bias in determining the electrical transport characteristics of all-perovskite oxide heterostructures.

Effect of loading density and weather conditions on animal welfare and meat quality of slaughter pigs

  • Jaewoo An;Yongju Kim;Minho Song;Jungseok Choi;Won Yun;Hanjin Oh;Seyeon Chang;Youngbin Go;Dongcheol Song;Hyunah Cho;Sanghun Park;Yuna Kim;Yunhwan Park;Gyutae Park;Sehyuk Oh;Jinho Cho
    • Journal of Animal Science and Technology
    • /
    • 제65권6호
    • /
    • pp.1323-1340
    • /
    • 2023
  • There are several factors that affect the welfare and meat quality of pigs during pre-slaughter transport. Among various factors, the effects of weather conditions and loading density were studied. A total of 3,726 finishing pigs were allotted to one of nine groups arranged in a 3 × 3 factorial design according to the weather conditions (low temperature [LT], under 10℃; normal temperature [NT], 10℃-24℃; high temperature [HT], upper 24℃), and loading density (low density [LD], upper 0.43 m2/100 kg; normal density [ND], 0.37-0.43 m2/100 kg; high density [HD], under 0.37 m2/100 kg). Each treatment group follow as: LTLD, LTND, LTHD, NTLD, NTND, NTHD, HTLD, HTND, HTHD. In terms of carcass composition, pigs had the highest carcass weight and backfat thickness at LT. Comparing the HD transport to the ND transport, the meat quality indicated a lower pH and more drip loss. The incidence rate of pale, soft, exudative (PSE) pork was high in the order of the HD, LD, and the ND transport (20%, 9%, and 2%, respectively). The HT transport showed the lowest pH and greatest L* value under the given weather conditions. Pigs transported under the HTHD and LTLD conditions had the greatest rates of PSE pork (40% and 20%, respectively). Pigs exposed to HD transport had the shortest laying time and the highest overplap behavior. The LDLT transport pigs had a shorter laying time than the LDNT and LDHT transport pigs. In conclusion, too high or too low density transport is generally not excellent for meat quality or animal welfare, however it is preferable to transport at a slightly low density at high temperature and at a slightly high density at low temperature.

Effect of Temperature on Dicarboxylate Transport in Plasma Membrane Vesicles of Rabbit Proximal Tubule

  • Han, Kyung-Moon;Kim, Young-Hee;Woo, Jae-Suk;Kim, Yong-Keun
    • The Korean Journal of Physiology
    • /
    • 제27권2호
    • /
    • pp.227-232
    • /
    • 1993
  • The temperature dependence of $Na^+-dependent$ succinate uptake was studied in brush border (BBMV) and basolateral (BLMV) membrane vesicles isolated from the rabbit kidney cortex. The succinate uptake was markedly altered by temperature in a similar fashion in both membranes. The temperature dependence was characterized by a nonlinear Arrhenius plot with a break point at 22 and $25^{\circ}C$ for BBMV and BLMV, respectively. The activation energy was 3.91 and 17.09 kcal/mole at above and below the break point respectively, far BBMV; 2.65 and 14.05 kcal/mole, respectively, for BLMV. When temperature increased f개m 20 to $35^{\circ}C$, the Vmax of succinate transport increased from $3.49{\pm}0.11\;to\;5.90{\pm}0.86\;nmole/mg/5\;sec$ for BBMV and from $2.86{\pm}0.25\;to\;3.63{\pm}0.32\;nmole/mg/5\;sec$ for BLMV, with no change in Km in both membranes. These results suggest that renal dicarboxylate transport is similarly sensitive to a change in membrane physical state in BBMV and BLMV.

  • PDF

유효열이송거리가 고온 태양열기기용 액체금속 히트파이프의 열전달 특성에 미치는 영향 (Influence of the Effective Thermal Thansport Length on the Heat Transfer Characteristics of a Liquid-Metal Heat Pipe for High-temperature Solar Thermal Devices)

  • 박철민;부준홍;김진수;강용혁
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.220-225
    • /
    • 2008
  • Cylindrical stainless-steel/sodium heat pipe for a high-temperature solar thermal application was manufactured and tested for transient and steady-state operations. Two layers of stainless-steel screen mesh wick was inserted as a capillary structure. The outer diameter of the heat pipe was 12.7 mm and the total length was 250 mm. The effective heat transport length, the thermal load, and the operating temperature were varied as thermal transport conditions of the heat pipe. The thermal load was supplied by an electric furnace up to 1kW and the cooling was performed by forced convection of air The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and vapor temperature. Typical range of the total effective thermal conductivity was as low as 43,500 W/m K for heat flux of 176.4 kW/$m^2$ and of operating temperature of 1000 K.

  • PDF

가역 루프 히트파이프의 작동특성에 관한 실험적 연구 (An Experimental Investigation on the Operating Characteristics of a Reversible Loop Heat Pipe)

  • 김봉훈;최준민
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.231-239
    • /
    • 2006
  • An experimental investigation of a Reversible Loop Heat Pipe (RLHP) was conducted to determine the operating limits and performance characteristics as functions of the thermophysical parameters, the heat input, and the cooling intensity. Variations in both temperature and heat transport capacity were measured and analyzed in order to accurately evaluate the transient operating characteristics. In addition, the maximum heat transport as a function of the mean evaporator temperature, the ratio of heat transport to heater input power as a function of the mean evaporator temperature, and the overall thermal resistance as a function of the overall heat transport capacity were examined as well. Results indicated that the cooling intensity played an important role on the operating characteristics and performance limitation. The maximum heat transports corresponding to cooling intensity $72W/^{\circ}C$ and $290W/^{\circ}C$ were 446 W and 924 W, respectively. Also, observation of the startup characteristics indicated that the mean evaporator temperature should be maintained between $40^{\circ}C$ and $60^{\circ}C$, and overall thermal resistance were measured as $0.02^{\circ}C/W$.

Vase Life and Quality of Cut Flower by Wet Solution according to Shipping Period and Temperature in Dendranthema grandiflorum 'Jinba'

  • Roh, Yong Seung;Kim, In Kyung;Yoo, Yong Kweon
    • 인간식물환경학회지
    • /
    • 제22권6호
    • /
    • pp.583-591
    • /
    • 2019
  • This study was conducted to examine the effects of wet storage solution, transport period and temperature on vase life and quality of cut flowers in standard chrysanthemum 'Jinba'. Immediately after transport, the fresh weight and flower diameter of cut flowers did not show a difference according to wet storage solutions regardless of the transport period, but as the transport period increased, the fresh weight and flower diameter increased. The flower bud stage at harvest was maintained due to the small changes in flower diameter, and the freshness of leaves was better when transported at 5℃ than at 25℃. When transported at 25℃, the longer the transport period, the lower the quality of cut flowers as some petals opened up and showed early flowering after transport. In preservative solutions, quality of cut flowers transported at 25℃ was lower than that at 5℃ due to fresh weight and diameter according to the longer transport period. The vase life of cut flowers was 1.0 day, 0.8 day, and 7.3 days longer when transported for 3, 5, and 7 days respectively at 5℃ than at 25℃. The quality of cut flowers was better due to increase in fresh weight and flower diameter, as well as vase life in wet storage solutions of ClO2 and Chrysal OVB than in tap water, regardless of transport period and temperature. There was no difference in fresh weight and vase life between ClO2 and Chrysal OVB, but flower diameter was greater in ClO2 than in Chrysal OVB. Therefore, for long-term transport of cut standard chrysanthemum 'Jinba', wet storage transport in ClO2 at 5℃ was found effective in maintaining the quality and vase life of cut flowers.

Characteristics of a Warm Eddy Observed in the Ulleung Basin in July 2005

  • Shin, Chang-Woong
    • Ocean and Polar Research
    • /
    • 제31권4호
    • /
    • pp.283-296
    • /
    • 2009
  • Oceanographic survey data were analyzed to understand the characteristics of a warm eddy observed in the Ulleung Basin in July 2005. The temperature distribution at 200 db and vertical sections provided evidence of the warm eddy in the Ulleung Basin (UWE05). Based on the 5$^{\circ}C$ isothermal line on 200 db temperature, the major axis was 160 km from southwest to northeast, and the minor axis was 80 km from southeast to northwest. The homogeneous layer in the thermocline of UWE05 had mean values of 10.40$^{\circ}C$ potential temperature, 34.35 psu salinity, and 26.37 kg/m$^3$ potential density (${\sigma}_{\theta}$) and provided evidence that UWE05 also existed during the winter of 2004-2005. A warm streamer initially flowed along the circumference of UWE05 and mixed with the upper central water. Two northward current cores were found on the western side of the measured current section at the central latitude of UWE05. One was the East Korean Warm Current (EKWC) and the other was the main stream of the western part of UWE05. Geostrophic transport of the upper layer (from the surface to the isopycnal surface of 26.9 ${\sigma}_{\theta}$) was approximately 2.5 Sv in the eastern side of UWE05. However, the measured transport was twice as large as the geostrophic transport. Mass conservation of geostrophic transport was well satisfied in the upper layer. The direct current measurements and geostrophic transport analysis showed that the EKWC meandered around UWE05.