• Title/Summary/Keyword: transmission map

Search Result 258, Processing Time 0.025 seconds

Prediction of potential spread areas of African swine fever virus through wild boars using Maxent model

  • Lim, Sang Jin;Namgung, Hun;Kim, Nam Hyung;Oh, Yeonsu;Park, Yung Chul
    • Journal of Ecology and Environment
    • /
    • v.46 no.1
    • /
    • pp.54-61
    • /
    • 2022
  • Background: In South Korea, African swine fever virus (ASFV) has spread among wild boars through Gangwon-do to Dangyang-gun, Chungcheongbuk-do on the southern border of Gangwon-do. To prevent the spread of ASFV to African swine fever (ASF)-free areas, it is necessary to identify areas with a high probability of finding ASFV-infected carcasses and to reduce the density of wild boars in those areas. In this study, we described the propagation trend of ASFV among wild boars, constructed the habitat suitability maps for ASFV-infected carcasses, and suggested areas with a high probability of finding ASFV-infected carcasses and an important route of ASFV transmission. Results: Despite the active quarantine policies in Korea to prevent the spread of ASFV through wild boars, there was no significant difference in the monthly average of number of ASFV-infected carcasses observed between 2020 and 2021. The ASFV-infected carcasses were found more in winter and spring (January to April). Since the first ASF outbreak in wild boars on October 2, 2019, the maximum width of ASFV-infected carcass distribution area was 222.7 km for about 26 months till November 20, 2021. The habitat suitability map, based on GPS coordinates of ASFV-infected wild boar carcasses, shows that highly detectable areas of ASFV-infected carcasses were sporadically dispersed in western and southwestern parts of Gangwon-do, and ranged from north to south of the province along the Baekdudaegan Mountains, whereas poorly detectable areas ranged along the north to the south in the middle parts of the province. Conclusions: Our suitability model, based on the GPS coordinates of ASFV-infected carcasses, identifies potential habitats where ASFV-infected carcasses are likely to be found and ponential routes where ASFV is likely to spread. Among ASF-free areas, the areas with high suitability predicted in this study should be given priority as survey areas to find ASFV-infected carcasses and hunting areas to reduce wild boar populations.

A Pilot Research for Real-Time Specific Patient Quality Assurance Using the Hybrid Optimized Vmat Phantom (Hovp) in Volume Modulated Arc Therapy (체적변조회전치료에서 Hybrid Optimized VMAT Phantom (HOVP)을 이용한 실시간 환자 맞춤형 정도관리를 위한 예비연구)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Kum-Bae;Kim, Seong-Hoon;Cho, Sam-Ju;Min, Chul-Kee;Cho, Kwang-Hwan;Lee, Sang-Hoon;Lee, Suk;Shim, Jang-Bo;Shin, Dong-Oh;Ji, Young-Hoon
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.206-215
    • /
    • 2011
  • The purpose of this was to investigate the measurement of fluence dose map for the specific patient quality assurance. The measurement of fluence map was performed using 2D matrixx detector. The absorbed dose was measured by a glass detector, Gafchromic film and ion chamber in Hybrid Optimized VMAT Phantom (HOVP). For 2D Matrixx, the results of comparison were average passing rate $85.22%{\pm}1.7$ (RT_Target), $89.96%{\pm}2.15$ (LT_Target) and $95.14%{\pm}1.18$ (G4). The dose difference was $11.72%{\pm}0.531$, $-11.47%{\pm}0.991$, $7.81%{\pm}0.857$, $-4.14%{\pm}0.761$ at the G1, G2, G3, G4. In HOVP, the results of comparison for film were average passing rate (3%, 3 mm) $93.64%{\pm}3.87$, $90.82%{\pm}0.99$. We were measured an absolute dose in steep gradient area G1, G2, G3, G4 using the glass detector. The difference between the measurement and calculation are 8.3% (G1), -5.4% (G2), 6.1% (G3), 7.2% (G4). The using an Ion-chamber were an average relative dose error $-1.02%{\pm}0.222$ (Rt_target), $0.96%{\pm}0.294$ (Lt_target). Though we need a more study using a transmission detector. However, a measurement of real-time fluence map will be predicting a dose for real-time specific patient quality assurance in volume modulated arc therapy.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

A Disaster Victim Management System Using Geographic Information System (지리정보시스템을 활용한 재난피해자 관리시스템)

  • Hwang, Hyun-Suk;Choi, Eun-Hye;Kim, Chang-Soo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.1
    • /
    • pp.59-72
    • /
    • 2011
  • The research of psychological supporting systems as safety and welfare for disaster victims damaged psychologically as well as physically by a sudden disaster to return to effectively their social life has been carried. The domestic National Emergency Management Agency(NEMA) is operating the Disaster Victim Psychology Support Center that helps with curing damaged psychology and studies the transmission system of psychology management services, the classification of victims for disaster psychology support, and emergency consultation method to systemically support disaster psychology management. However, current psychology supporting centers provide the simple information for supporting centers such as medical and social welfare organizations. The development research of IT-based management systems to obtain needed information to construct the proposed systems curing psychological damage is still primitive step. Therefore, this paper shall propose a GIS-based integrated management system for victims and managers to effectively share related information one another and to return to victims' social life as soon as possible. Also, we implement a simple prototype system based on the Web. The proposed system supports the spatial search and statistical analysis based on map as well as keyword search, because having the location information on disaster victims, damage occurrence places, welfare and medical institutions, and psychological supporting centers. In addition, this system has the advantage reducing the frequency of disaster damage by providing aids in making efficient policy systems for the managers.

A Depth-based Disocclusion Filling Method for Virtual Viewpoint Image Synthesis (가상 시점 영상 합성을 위한 깊이 기반 가려짐 영역 메움법)

  • Ahn, Il-Koo;Kim, Chang-Ick
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.6
    • /
    • pp.48-60
    • /
    • 2011
  • Nowadays, the 3D community is actively researching on 3D imaging and free-viewpoint video (FVV). The free-viewpoint rendering in multi-view video, virtually move through the scenes in order to create different viewpoints, has become a popular topic in 3D research that can lead to various applications. However, there are restrictions of cost-effectiveness and occupying large bandwidth in video transmission. An alternative to solve this problem is to generate virtual views using a single texture image and a corresponding depth image. A critical issue on generating virtual views is that the regions occluded by the foreground (FG) objects in the original views may become visible in the synthesized views. Filling this disocclusions (holes) in a visually plausible manner determines the quality of synthesis results. In this paper, a new approach for handling disocclusions using depth based inpainting algorithm in synthesized views is presented. Patch based non-parametric texture synthesis which shows excellent performance has two critical elements: determining where to fill first and determining what patch to be copied. In this work, a noise-robust filling priority using the structure tensor of Hessian matrix is proposed. Moreover, a patch matching algorithm excluding foreground region using depth map and considering epipolar line is proposed. Superiority of the proposed method over the existing methods is proved by comparing the experimental results.

Efficient Data Representation of Stereo Images Using Edge-based Mesh Optimization (윤곽선 기반 메쉬 최적화를 이용한 효율적인 스테레오 영상 데이터 표현)

  • Park, Il-Kwon;Byun, Hye-Ran
    • Journal of Broadcast Engineering
    • /
    • v.14 no.3
    • /
    • pp.322-331
    • /
    • 2009
  • This paper proposes an efficient data representation of stereo images using edge-based mesh optimization. Mash-based two dimensional warping for stereo images mainly depends on the performance of a node selection and a disparity estimation of selected nodes. Therefore, the proposed method first of all constructs the feature map which consists of both strong edges and boundary lines of objects for node selection and then generates a grid-based mesh structure using initial nodes. The displacement of each nodal position is iteratively estimated by minimizing the predicted errors between target image and predicted image after two dimensional warping for local area. Generally, iterative two dimensional warping for optimized nodal position required a high time complexity. To overcome this problem, we assume that input stereo images are only horizontal disparity and that optimal nodal position is located on the edge include object boundary lines. Therefore, proposed iterative warping method performs searching process to find optimal nodal position only on edge lines along the horizontal lines. In the experiments, we compare our proposed method with the other mesh-based methods with respect to the quality by using Peak Signal to Noise Ratio (PSNR) according to the number of nodes. Furthermore, computational complexity for an optimal mesh generation is also estimated. Therefore, we have the results that our proposed method provides an efficient stereo image representation not only fast optimal mesh generation but also decreasing of quality deterioration in spite of a small number of nodes through our experiments.

Dose Verification of Intensity Modulated Radiation Therapy with Beam Intensity Scanner System

  • Vahc, Young-Woo;Park, Kwangyl;Ohyun Kwon;Park, Kyung-Ran;Lee, Yong-Ha;Yi, Byung-Yong;Kim, Sookil
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.248-251
    • /
    • 2002
  • The intensity modulated radiation therapy (IMRT) with a multileaf collimator (MLC) requires the conversion of a radiation fluence map into a leaf sequence file that controls the movement of the MLC during radiation treatment of patients. Patient dose verification is clinically one of the most important parts in the treatment delivery of the radiation therapy. The three dimensional (3D) reconstruction of dose distribution delivered to the target helps to verify patient dose and to determine the physical characteristics of beams used in IMRT. A new method is presented for the pretreatment dosimetric verification of two dimensional distributions of photon intensity by means of Beam Intensity Scanner System (BISS) as a radiation detector with a custom-made software for dose calculation of fluorescence signals from scintillator. The scintillator is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The BISS reproduces 3D- relative dose distribution from the digitized fluoroscopic signals obtained by digital video camera-based scintillator(DVCS) device in the IMRT. For the intensity modulated beams (IMBs), the calculations of absorbed dose are performed in absolute beam fluence profiles which are used for calculation of the patient dose distribution. The 3D-dose profiles of the IMBs with the BISS were demonstrated by relative measurements of photon beams and shown good agreement with radiographic film. The mechanical and dosimetric properties of the collimating of dynamic and/or step MLC system alter the generated intensity. This is mostly due to leaf transmission, leaf penumbra and geometry of leaves. The variations of output according to the multileaf opening during the irradiation need to be accounted for as well. These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planning for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

Real-time Natural Disaster Failure Analysis Information System Development using GIS Environment (GIS환경의 실시간 자연재해정보를 연계한 재해고장분석시스템 개발)

  • Ahn, Yeon-S.
    • Journal of Digital Contents Society
    • /
    • v.10 no.4
    • /
    • pp.639-648
    • /
    • 2009
  • Earth's environment issues are introduced recently and every year the social loss have been occurred by the impact of various disaster. This kind of disaster and weather problems are the increasing reason of electricity transmission network equipment's failures because of exposing by the natural environment. The emergency and abnormal status of electricity equipment make the power outage of manufacturing plant and discomfort of people's lives. So, to protect the electricity equipment from the natural disasters and to supply the power to customer as stable, the supporting systems are required. In this paper, the research results are described the development process and the outcomes of the real-time natural disaster failure analysis information system including the describing about the impact of disaster and weather change, making the natural weather information, and linking the realtime monitoring system. As of development process, according to application development methodology, techniques are enumerated including the real time interface with related systems, the analysing the geographic information on the digital map using GIS application technology to extract the malfunction equipment potentially and to manage the equipments efficiently. Through this system makes remarkable performance it minimize the failures of the equipments, the increasing the efficiency of the equipment operation, the support of scientific information related on the mid-term enhancement plan, the savings on equipment investment, the quality upgrading of electricity supply, and the various supports in the field.

  • PDF

Impact of Contrast Agent for PET Images with CT-based Attenuation Correction (CT 영상을 이용한 감쇠 보정 시 조영제가 PET 영상에 미치는 영향)

  • Son Hye-Kyung;Turkington Timothy G.;Kwon Yun-Young;Jung Haijo;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.192-201
    • /
    • 2005
  • Experiments and simulation were done to study the impact of contrast agent when CT scan was used to attenuation correction for PET Images in PET/CT system. Whole body phantom was imaged with various concentration of iodine-based contrast agent using CT. Mathematical emission and transmission density map with liver were made to simulate for whole body FDG Imaging. A variety of factors were estimated, including non-uniform enhancement of contrast agent, concentration and distribution size of contrast agent, noise level, image resolution, reconstruction algorithm, hypo-attenuation of contrast agent, and different time phases for contrast agent. Experimental studies showed that Hounsfield unit depends on the concentration of contrast agent and tube voltage. From the simulation data, contrast agents Introduced artifacts and degraded image quality on the attenuation-corrected PET images. The severity of these effects depends on a variety of factors, including the concentration and distribution size of contrast agent, the noise levels, and the Image resolution. These results Indicated that the impact of contrast agents should be considered with a full understanding of their potential problems in clinical PET/CT images.

  • PDF

A Utility-Based Hybrid Error Recovery Scheme for Multimedia Transmission over 3G Cellular Broadcast Networks (3G 방송망에서의 효율적인 멀티미디어 전송을 위한 유틸리티 기반 하이브라드 에러 복구기법)

  • Kang Kyung-Tae;Cho Yong-Jin;Cho Yong-Woo;Cho Jin-Sung;Shin Heon-Shik
    • Journal of KIISE:Information Networking
    • /
    • v.33 no.4
    • /
    • pp.333-342
    • /
    • 2006
  • The cdma2000 lxEV - DO mobile communication system provides broadcast and multicast services (BCMCS) to meet an increasing demand from multimedia data services. The servicing of video streams over a BCMCS network must, however, face a challenge from the unreliable and error-prone nature of the radio channel. The BCMCS network uses Reed-Solomon coding integrated with the MAC protocol for error recovery. We analyze this coding technique and show that it is not effective in the case of slowly moving mobiles. To improve the playback quality of an MPEG-4 FGS video stream, we propose the Hybrid error recovery scheme, which combines Reed-Solomon with ARQ, using slots which are saved by reducing the Reed-Solomon coding overhead. The target packets to be retransmitted are prioritized by a utility function to reduce the packet error rate in the application layer within a fixed retransmission budget. This is achieved by considering of the map of the error control block at each mobile node. The proposed Hybrid error recovery scheme also uses the characteristics of MPEG-4 FGS (fine granularity scalability) to improve the video quality even when conditions are adverse: slow-moving nodes and a high error rate in the physical channel.