• 제목/요약/키워드: transmission line parameters

검색결과 289건 처리시간 0.037초

고속 전력선 통신을 위한 전력선채널 잡음 및 임피던스 특성 분석 (Analysis of Channel Noise and Impedance Characteristics for High-Speed Power-Line Communication)

  • 김정훈;김선효;김상태;이영철;신철재
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(1)
    • /
    • pp.37-40
    • /
    • 2001
  • Subject of this paper is analysis of channel noise and impedance characteristics for high speed power line communication to concerned noise of transmission line and impedance in the frequency range up to 30MHz. Parameters of transmission line was inducted from experimentally power line channel measurement. Moreover, Analysis of compared based on measurement of channel characters with simulation test for appear characters.

  • PDF

송전선에 의해 송전철탑에 전달되는 풍하중 저감을 위한 회전형 점탄성감쇠기 (Rotational Viscoelastic Dampers for the Mitigation of Wind Loads on Transmission Tower Transferred from Transmission Lines)

  • 문병욱;민경원
    • 한국소음진동공학회논문집
    • /
    • 제16권4호
    • /
    • pp.420-427
    • /
    • 2006
  • In this study, wind loads transmitted to a transmission tower from transmission lines are mitigated using rotational viscoelastic dampers. First, the wind load characteristics in a transmission tower is investigated considering the effect of the transmission lines through stochastic analysis. The assemblage of the transmission line and insulator are modeled as a double pendulum system connected to the SDOF model of the tower. From the result of the stochastic analysis, the background component of the overturing moment caused by the wind loads acting on the transmission lines are found to have considerable portion in the total overturning moment. Based on this observation result, a strategy Installing rotational viscoelastic damper (VED) between tower arm and transmission line is proposed for the mitigation of the transmission line reactions, which play a role as dynamic loads on a transmission tower. For the purpose of verification, time history analysis is conducted for different wind velocities and VED parameters. The analysis result shows that the rotational VED is effective for the mitigation of the background component rather than the resonance component of the transmission line reactions and achieves the reduction ratio of 50% even for higher wind speed.

UPFC연계시 거리계전기 동작특성에 따른 보호 관리 시스템 (Protective Management System followed Distance Relay characteristics for Transmission Line with the Unified Power Flow Controller)

  • 서정남;정창호;조종만;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.296-298
    • /
    • 2001
  • This paper represents protective management system for transmission line involving the UPFC(Unified Power Flow Controller) device, which is the most vigorous component of FACTS. The presence of the UPFC significantly affects the line parameters of transmission system, which are also influenced by the distance relay setting. Moreover, depending on the UPFC location and its parameters, zones of setting the distance relay will be changed. Therefore, established protective system should be taken into account the variable injected voltage of the UPFC and constructed data base system.

  • PDF

송전선로에 UPFC연계시 거리계전기 동작특성에 관한 연구 (A Study on Distance Relay characteristics for Transmission Line with the Unified Power Flow Controller)

  • 서정남;정창호;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.220-222
    • /
    • 2001
  • This paper represents impedance calculation of the distance relay using PSCAD/EMTDC software for transmission line involving the UPFC (Unified Power Flow Controller) device, which is the most vigorous component of FACTS. The presence of the UPFC significantly affects the line parameters of transmission system, which are also influenced by the distance relay setting. Moreover depending on the UPFC location and its parameters, zones of setting the distance relay will be changed. The presence of the UPFC in the fault loop affects both voltage and current seen by relay. Therefore, the distance relay should be taken into account the variable injected voltage of the UPFC.

  • PDF

Power Reflection and Transmission Coefficients for Meander-Line Polarizers with a Chiral Slab

  • Delihacioglu, Kemal;Uckun, Savas
    • ETRI Journal
    • /
    • 제25권1호
    • /
    • pp.41-48
    • /
    • 2003
  • This paper presents a theoretical investigation of power reflection and transmission coefficients for a meander-line polarizer placed periodically on a chiral slab. It is assumed that a linearly polarized transverse magnetic wave is incident on a chiral slab from the air region. In the analysis, we derive the electric and magnetic fields in the modal form in the air and chiral regions. We obtain power reflection and transmission coefficients in a straightforward manner after matching the tangential components of the electric and magnetic fields at the boundaries. We present numerical results for the power reflection and transmission coefficients versus frequency and incident angle for different values of the chirality admittance. A meander-line polarizer placed on a dielectric slab can convert a linearly polarized wave to a circularly polarized wave. The design parameters for a meander-line polarizer are the dimensions of the meander-line and the values of the dielectric slab. Replacing a dielectric slab with a chiral slab introduces a new independent parameter which controls the wave polarization.

  • PDF

Analysis of Different 500kV HVAC Transmission Lines Lightning Shielding

  • Nayel, Mohamed
    • 한국융합학회논문지
    • /
    • 제4권4호
    • /
    • pp.49-57
    • /
    • 2013
  • The lightning shielding of different 500 kV HVAC-TL high voltage AC transmission lines was analyzed. The studied transmission lines were horizontal flat single circuit and double circuit transmission lines. The lightning attractive areas were drawn around power conductors and shielding wires. To draw the attractive areas of the high voltage transmission lines, transmission line power conductors, shielding wires and lightning leader were modeled. Different parameters were considered such as lightningslope, ground slope and wind on lightning attractive areas. From the calculated results, the power conductors voltages affected on attractive areas around power conductors and shielding wires. For negative lightning leader, the attractive area around the transmission line power conductor increased around power conductors stressed by positives voltage and decreased around power conductors stressed by negative voltage. In spite of this, the attractivearea of the transmission line shielding wire increasedaround the shielding wire above the power conductor stressed by the positive voltage and decreased around the shielding wire above the power conductor stressed by negative voltage. The attractive areas around power conductors and shielding wires were affected by the surrounding conditions, such as lightning leader slope, ground slope. The AC voltage of the transmission lines made the shielding areas changing with time.

특정 손실 매질위의 다중 결합선로에 대한 손실특성 개선 (Improvement of Attenuation Characteristics for Multiple Coupled Line Structure on the Specific Lossy Media)

  • 김윤석;김민수
    • 대한전자공학회논문지TC
    • /
    • 제48권12호
    • /
    • pp.35-41
    • /
    • 2011
  • 본 논문에서는 손실매질의 다층구조로 이루어진 마이크로 스트립선로의 손실특성의 개선을 위한 새로운 구조를 제안한다. MIS 구조로 된 전송선로의 Si와 SiO2층 사이에 0전위를 가진 도체를 일정한 간격의 주기적인 배열로 고안된 새로운 모델의 MIS구조에 대한 유한차분법을 이용한 해석방법이 사용된다. 특히 전송선로에 대한 유전체의 영향을 줄이기 위하여 0전위를 가진 주기적인 결합의 도체로 이루어진 구조가 시간영역의 신호를 통해 시험된다. 다양한 0전위 도체의 간격(갭)에 따른 주파수 의존적인 추출된 전송선로 파라미터와 등가회로 파라미터가 주파수 함수로서 나타내진다. 또한 본 논문에서 고안된 구조에 대해 특성임피던스와 유효유전상수의 큰 변화 없이 대칭 결합선로의 quality factor가 개선됨을 볼 수 있다.

삼각 패치형 인공 전송 선로를 이용한 브랜치 라인 하이브리드 (A Branch-Line Hybrid Using Triangle-Patch Type Artificial Transmission Line)

  • 오송이;황희용
    • 한국전자파학회논문지
    • /
    • 제23권7호
    • /
    • pp.768-773
    • /
    • 2012
  • 본 논문에서는 슬롯을 갖는 삼각 패치형 인공 전송 선로를 이용한 브랜치 라인 하이브리드를 제안한다. 제안된 인공 전송 선로는 구조가 콤팩트하고 슬롯의 파라미터들을 변화시킴으로써 선로의 특성 임피던스와 전기적 길이를 조절하는 데 용이하여 일반적인 전송 선로를 소형화시키는 데 유용하다. 제안된 브랜치 라인 하이브리드는 이러한 직각 삼각형의 인공 전송 선로들을 이용하여 구현되었기 때문에 공간의 활용도가 높고 소형화되었다. 제작된 3 dB 브랜치 라인 하이브리드는 중심 주파수 2.45 GHz의 15 % 대역폭 내에서 ${\pm}0.5$ dB의 결합도 변화 특성과 두 출력 포트 간 $91^{\circ}{\pm}4^{\circ}$의 위상차 특성을 보였다. 또한, 제안된 브랜치 라인 하이브리드의 크기는 일반적인 브랜치 라인 하이브리드 크기의 38 %이다.

저압배선의 이상 진단을 위한 시간-주파수영역 반사파계측 방법의 기준신호 설계기법 연구 (Reference Signal Design of TFDR for Low Voltage Power Transmission Line)

  • 이춘구;곽기석;박진배;윤태성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1543-1544
    • /
    • 2008
  • In this paper, we introduce a gaussian enveloped linear chirp signal that can change parameters for consideration of target material characteristics. Using the gaussian enveloped linear chirp signal, time-frequency domain reflectomety is able to detect fault location in power transmission line. we suggest design method of reference signal for power transmission line fault detection. This method is verified by locating fault in HIV low voltage power transmission line.

  • PDF

송전용 자기재 애자의 시멘트 변위 응력에 관한 시뮬레이션 (A Simulation on the Displacement Stress of Cement in Porcelain Insulators for Transmission Line)

  • 한세원;조한구;우병철;정길조;이동일;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.476-479
    • /
    • 2002
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied the effect of cement displacement resulting environmental ageing parameters on porcelain insulator mechanical properties for transmission line by simulation (ANSYS/NASTRAN program) and test methods. These simulation analysis and experimental results show that cement volume growth affects severely to be mechanical failure ageing.

  • PDF