• Title/Summary/Keyword: transmission line model

Search Result 532, Processing Time 0.024 seconds

Analysis of the Ultrasonic Signals by the Partial Discharge and Noises from the Transformer (변압기 부분방전과 노이즈에 의한 초음파 신호 분석)

  • Gwon, Dong-Jin;Jeong, Gil-Jo;Jin, Sang-Beom;Gwak, Hui-Ro
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.354-360
    • /
    • 2002
  • The partial discharge detecting method using the ultrasonic technique has been investigated to monitor the insulation ageing of a transformer. However, the result of the studies on the ultrasonic technique for detecting of partial discharge in the operating transformer is not enough yet to utilize. This paper presents the analysis of the ultrasonic signals due to the partial discharge in a model transformer and the corona in air at a shielded high voltage room. In addition, the ultrasonic signals due to the vibration from the core, operation of the cooling pump, the fan and the OLTC at the 345㎸ power transformer, were analyzed and corona noise from overhead transmission line in 345㎸ substation were measured to remove the electrical and mechanical noises from the transformer. Furthermore, ultrasonic signal due to the partial discharge in the 154㎸ power transformer with in $C_2$$H_2$ gas warning condition was measured. The inside of the transformer was examined with care. which confirms the existence of the partial discharge source.

A Study on the Bandwidth Improvement of the Microstrip Antenna for Mobile Communications (이동통신용 마이크로스트립 안테나의 대역폭 개선에 관한 연구)

  • 김대중;문명호;김갑기;이종악
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.1
    • /
    • pp.8-15
    • /
    • 1998
  • In this paper, to improve the bandwidth of microstrip antenna, we discussed parasitic patch structure coupled capacitively at radiating slot. To reduce the overal size of antenna,$\lambda$/4 short structure is accepted instead of $\lambda$/2 patch. Since ground plane is reduced, backward radiation is occurred. The characteristics of the designed antenna is evaluated, based on the transmission line model and the aperture analysis method. And by computer program the radiation pattern and return loss are evaluated. As simulation results, backward radiation is -15 dB. Bandwidth of constructed antenna is 167 MHz at the resonant frequency of 2.45 GHz, which is very broad, compared to conventional microstrip antennas. Therefore the proposed antenna will be suitable for very wide bandwidth communications.

  • PDF

LMP Calculation with Consideration of Transaction Strategy and Quadratic Congestion Cost Function (거래전략 및 Quadratic 혼잡비용을 고려한 LMP산정에 대한 연구)

  • Kim, Jae-Wook;Jung, Sung-Hun;Min, Kyung-Il;Moon, Young-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.257-265
    • /
    • 2011
  • As the competitive market system has been introduced to the electrical power trade, the priority concern would be that the price of electrical power should be reasonable. It is because, when this rule is solid, we can avoid the distortion of competition and assure the greater efficiency in management. LMP(Locational Marginal Price) means marginal price at each bus. This components consist of energy, loss and congestion cost. At this point, the LMP result that is calculated by traditional model is changeable by the location of the slack and can not be used in bilateral Transaction. This paper proposed algorithm is proved its rationality and credibility by comparing the result of the simulation of virtual 6_bus system that is calculated by traditional method, and showed that the LMP components are changed according to the Transaction Strategy. Furthermore, It shows the effect of additional congestion cost on the transmission line that has bottle neck frequently by simulation.

Study on Tension and Thermal Properties of Corrosive-fractured Steel Sleeve (강 슬리브 파단 직선 슬리브의 장력 및 열적 특성 분석 연구)

  • Ahn, Sang-Hyun;Kim, Byung-Geol;Kim, Sang-Shu;Sohn, Hong-Kwan;Kim, In-Pyo;Kim, Sung-Kyu
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.11
    • /
    • pp.1036-1041
    • /
    • 2008
  • According to previous report, aged sleeves of old transmission line showed several defaulted installation patterns, which was biased or corrosive-fractured of steel sleeve installed cases. These defects can cause serious accidents such as rapid increasing of sag or falling out of overhead conductor from sleeves. Consequently, the defects lead to the major power outage. Corrosion of steel sleeve is a typical defect by aging of sleeves. And it occupied almost 25 percent of investigated aged sleeves. This paper studied thermal properties and tension for ACSR conductor in case of fractured steel sleeve model by corrosion. The temperature distribution within overhead conductor has a specific gradient. Thermal properties of splice connectors(sleeve and clamp) showed normal behavior. However, mechanical properties were worse than normal sleeves. The detailed results were presented in the text.

Ohmic contact formation of single crystalline 3C-SiC for high temperature MEMS applications (초고온 MEMS용 단결정 3C-SiC의 Ohmic Contact 형성)

  • Chung, Gwiy-Sang;Chung, Su-Yong
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.131-135
    • /
    • 2005
  • This paper describes the ohmic contact formation of single crystalline 3C-SiC thin films heteroepitaxially grown on Si(001) wafers. In this work, a TiW (Titanium-tungsten) film as a contact matieral was deposited by RF magnetron sputter and annealed with the vacuum and RTA (rapid thermal anneal) process respectively. Contact resistivities between the TiW film and the n-type 3C-SiC substrate were measured by the C-TLM (circular transmission line model) method. The contact phases and interface the TiW/3C-SiC were evaulated with XRD (X-ray diffraction), SEM (scanning electron microscope) and AES (Auger electron spectroscopy) depth-profiles, respectively. The TiW film annealed at $1000^{\circ}C$ for 45 sec with the RTA play am important role in formation of ohmic contact with the 3C-SiC substrate and the contact resistance is less than $4.62{\times}10^{-4}{\Omega}{\cdot}cm^{2}$. Moreover, the inter-diffusion at TiW/3C-SiC interface was not generated during before and after annealing, and kept stable state. Therefore, the ohmic contact formation technology of single crystalline 3C-SiC using the TiW film is very suitable for high temperature MEMS applications.

Design of a Small Loop Microstrip Antenna to load Capacitors (용량을 장하한 미소 루프 마이크로스트립 안테나 설계)

  • Park Seong-Il;Ko Young-Hyuk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.637-640
    • /
    • 2006
  • In this paper, a microstrip antenna with a small loop consisting of the left and right parallel plate to load capacitor is proposed. It is obtained the improved small size than the antenna of the transformed Uh and the antenna of the left and right parallel plate to load capacitor on QMSA. Equivalent circuit of transmission line model is designed to find more accurate resonant frequency. Also, the designed and fabricated antenna can receive both vertically and horizontally polarized waves to operating frequency of 1.5GHz. Therefore proposed antenna is available as a small antenna for wireless communication and will be quite useful for indoor communication

  • PDF

Nondestructive Inspection of Steel Structures Using Phased Array Ultrasonic Technique (위상배열 초음파기법을 이용한 강구조물의 비파괴 탐상)

  • Shin, Hyeon-Jae;Song, Sung-Jin;Jang, You-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.538-544
    • /
    • 2000
  • A phased array ultrasonic nondestructive inspection system is being developed to obtain images of the interior of steel structures by modifying a medical ultrasound imaging system. The medical system consists of 64 individual transceiver channels that can drive 128 array elements. Several modifications of the system were required mainly due to the change of sound speed. It was necessary to fabricate array transducers for steel structure and to obtain A-scan signal that is necessary for the nondestructive testing. Boundary diffraction wave model was used for the prediction of radiation beam field from array transducers, which provided guidelines to design array transducers. And a RF data acquisition board was fabricated for the A-scan signal acquisition along a selected un line within an image. For the proper beam forming in the transmission and reception for steel structure, delay time was controlled. To demonstrate the performance of the developed system and fabricated transducers, images of artificial specimens and A-scan signals for selected scan lines were obtained in a real time fashion.

  • PDF

Full Parametric Impedance Analysis of Photoelectrochemical Cells: Case of a TiO2 Photoanode

  • Nguyen, Hung Tai;Tran, Thi Lan;Nguyen, Dang Thanh;Shin, Eui-Chol;Kang, Soon-Hyung;Lee, Jong-Sook
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.3
    • /
    • pp.244-260
    • /
    • 2018
  • Issues in the electrical characterization of semiconducting photoanodes in a photoelectrochemical (PEC) cell, such as the cell geometry dependence, scan rate dependence in DC measurements, and the frequency dependence in AC measurements, are addressed, using the example of a $TiO_2$ photoanode. Contrary to conventional constant phase element (CPE) modeling, the capacitive behavior associated with Mott-Schottky (MS) response was successfully modeled by a Havriliak-Negami (HN) capacitance function-which allowed the determination of frequency-independent Schottky capacitance parameters to be explained by a trapping mechanism. Additional polarization can be successfully described by the parallel connection of a Bisquert transmission line (TL) model for the diffusion-recombination process in the nanostructured $TiO_2$ electrode. Instead of shunt CPEs generally employed for the non-ideal TL feature, TL models with ideal shunt capacitors can describe the experimental data in the presence of an infinite-length Warburg element as internal interfacial impedance - a characteristic suggested to be a generic feature of many electrochemical cells. Fully parametrized impedance spectra finally allow in-depth physicochemical interpretations.

Model-Based Detection of Pipe Leakage at Joints (모델 기반 파이프 연결부 누수 감지 시스템)

  • Kim, Taejin;Youn, Byeng D.;Woo, Sihyeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.3
    • /
    • pp.347-352
    • /
    • 2015
  • Time domain reflectometry (TDR) is widely used for wire failure detection. It transmits a pulse that is reflected at the boundaries of different characteristic impedances. By analyzing the reflected signal, TDR makes it possible to locate the failure. In this study, TDR was used to detect the water leakage at a pipe joint. A wire attached to the pipe surface was soaked by water when a leak occurred, which affected the characteristic impedance of the wet part, resulting in a change in the reflected signal. To infer the leakage from the TDR signal, we first developed a finite difference time domain-based forward model that provided the output of the TDR signal given the configuration of the transmission line. Then, by solving the inverse problem, the locations of the leaks were found.

A Gigabit Serial Transceiver Design Using FPGA for Satellite Communication Transponder (위성통신 중계기에서의 FPGA를 이용한 Gigabit 시리얼 송수신기 설계)

  • Hong, Keun-Pyo;Lee, Jung-Sub;Jin, Byoung-Il;Ko, Hyun-Suk;Seo, Hak-Geum
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.8
    • /
    • pp.481-487
    • /
    • 2014
  • In this paper, we have proposed gigabit serial transceiver based on backplane architecture at the satellite communication digital transponder. The transponder supports the full combinational switching function with broadband multi-channel using programmable device - Xilinx space-grade Virtex-5 FPGA. In order to implement the switching function, GTX transceiver solution inside Virtex-5 FPGA is used. Also hardware implementation is simple because of no additional component. In order to use a GTX transceiver, signal integrity(SI) simulation of PCB design is essential. We investigate the characteristics of the S-parameter, eye diagram, channel jitter of GTX transmission line and conform that GTX Transceiver operates without error. Finally the proposed PCB design will be utilized at satellite communication digital transponder EQM-2(Engineering Qualification Model-2).