• Title/Summary/Keyword: transmission dose

Search Result 219, Processing Time 0.027 seconds

Handover Scheme between WiFi and Mobile WiMax (WiFi와 mobile WiMax간 핸드오버 방안)

  • Park, Seung-Kyun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.34-41
    • /
    • 2011
  • At present wireless internet access service is available through the 3G network, mobile WiMAX and WiFi anytime and anywhere. In this environment where there are various networks, users should be able to select specific networks depending on different situations. And it is necessary to provide mobility support between homogeneous and between heterogenous networks. Given this situation, the many proposals have been presented to link 3G, which has the largest service area among various networks, with mobile WiMAX(IEEE 802.16e), or with WiFi(IEEE 802.11). But, recently, with the increasing volume of wireless internet use and wireless internet data, due to the advents of net-book, e-book and smart phone, the service area of WiFi and mobile WiMAX has rapidly expanded. Especially, the availability of real-time application such as internet phone has led to the relative shrinking of the proportion of 3G mobile communication network giving conventional voice service, and enlargement of those of wireless internet access networks like WiFi and mobile WiMAX. This paper suggests a handover scheme based on PMIPv6, whitch support mobility between WiFi and mobile WiMAX, and minimizes handover delay. In this scheme, the mobile node has a dual stack structure composed of two interfaces-WiFi and mobile WiMAX. Since WiFi dose not support mobility, it is suggested that the mobile node have the capacity to deal with handover signaling between gateway in case of handover between homogeneous networks. This handover scheme, suggested comparing with current handovers between homogeneous networks, has proved, in its analytic evaluation, to be able to reduce handover, transmission, and signaling overhead.

EARLY IRRADIATION EFFECTS ON THE ULTRASTRUCTURE OF THE CAPILLARY ENDOTHELIAL CELL IN THE RAT SUBMANDIBULAR GLANDS (방사선조사에 따른 백서 악하선내 혈관 내피세포 미세구조의 조기변화)

  • Ryu Jung-Soo;Sohn Jaong-Ick;Baa Yong-Chul;Choi Karp-Shik
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.71-87
    • /
    • 1995
  • The purpose of this study was to investigate the early irradiation changes on the ultrastructure of the capillary endothelial cell in the rat submandibular glands. For the study, 110 Sprague-Dawley strain male rats were singly irradiated to their neck regions with the doses of 2Gy, 5Gy, and 10Gy by 6MV X -irradiation, and sacrificed on the 3 hours, 6 hours, 12 hours, 1 day, 3 days, 7 days, and 14 days after irradiation. The authors observed the histologic and ultrastructural changes of the capillary endothelial cell using the light and electron microscopes. The results were as follows: I. In the light microscopic examination, the capillary dilation was observed on the 6 hours group and the capillary density was slightly increased on the 12 hours group after 2Gy and 5Gy irradiation. And luminal size and capillary density were decreased on the 3 days and the 7 days groups after irradiation, after then, they were recovered. But capillary density was still decreased on the 14 days group after 10Gy irradiation. 2. In the transmission electron microscopic examination, the mild proliferation of cytoplasmic process of the endothelial cell and reduction in luminal size were observed on the 3 hours group after irradiation. After then, endothelial swelling, marked proliferation of cytoplasmic process, thickened basal lamina, and numerous pinocytotic vesicles were observed after the 1 day group after irradiation. Thickened basal lamina and numerous pinocytotic vesicles were still observed until the 7 days group after irradiation. These changes were recovered to normal on the 14 days group after 2Gy and 5Gy irradiation, but not after 10Gy irradiation. 3. In the scanning electron microscopic examination, the dilation of conduits and constriction, and meandering were observed on the 1 day group after 10Gy irradiation. These changes were observed with increased coarseness of the surface of the vascular resin casting on the 3 days group after irradiation. 4. From the above results, endothelial swelling, proliferation of cytoplasmic process, and thickening of the basal lamina appeared before the 6 hours group after irradiation. And these changes may also induce the increase of the capillary number and luminal size, after then, capillary permeability was increased via the increase of the number of pinocytotic vesicles. The changes were observed earlier and more apparent with the increase of the irradiation doses under the dose of 10Gy irradiation.

  • PDF

Induction of DNA Damage in L5178Y Cells Treated with Gold Nanoparticle

  • Kang, Jin-Seok;Yum, Young-Na;Kim, Joo-Hwan;Song, Hyun-A;Jeong, Jin-Young;Lim, Yong-Taik;Chung, Bong-Hyun;Park, Sue-Nie
    • Biomolecules & Therapeutics
    • /
    • v.17 no.1
    • /
    • pp.92-97
    • /
    • 2009
  • As nanomaterials might enter into cells and have high reactivity with intracellular structures, it is necessary to assay possible genotoxic risk of them. One of these approaches, we investigated possible genotoxic potential of gold nanoparticle (AuNP) using L5178Y cells. Four different sizes of AuNP (4, 15, 100 or 200 nm) were synthesized and the sizes and structures of AuNP were analyzed using transmission electron microscopy (TEM), scanning electron microscopy (SEM) and stability was analyzed by a UV/Vis. Spectrophotometer. Cytotoxicity was assessed by direct cell counting, and cellular location was detected by dark field microscope at 6, 24 and 48 h after treatment of AuNP. Comet assay was conducted to examine DNA damage and tumor necrosis factor (TNF)-${\alpha}$ mRNA level was assay by real-time reverse transcription polymerase chain reaction. Synthetic AuNP (4, 50, 100 and 200 nm size) had constant characteristics and stability confirmed by TEM, SEM and spectrophotometer for 10 days, respectively. Dark field microscope revealed the location of AuNP in the cytoplasm at 6, 24 and 48 h. Treatment of 4 nm AuNP induced dose and time dependent cytotoxicity, while other sizes of AuNP did not. However, Comet assay represented that treatment of 100 nm and 200 nm AuNP significantly increased DNA damage compared to vehicle control (p <0.01). Treatment of 100 nm and 200 nm AuNP significantly increased TNF-${\alpha}$ mRNA expression compared to vehicle control (p<0.05, p<0.01, respectively). Taken together, AuNP induced DNA damage in L5178Y cell, associated with induction of oxidative stress.

An Evaluation on the Radiation Shielding of the Radwaste Drum Assay Facility (방사성폐기물드럼 핵종재고량 평가시설 구축에 따른 방사선차폐 영향평가)

  • Ji, Young-Yong;Kwak, Kyung-Kil;Hong, Dae-Seok;Shon, Jong-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.2
    • /
    • pp.117-123
    • /
    • 2012
  • In order to dispose of the LILW(low and intermediate level radioactive waste) stored at KAERI, the radwaste drum assay system will be introduced to evaluate the radioisotopes inventory of stored drums. At present, the construction project of the dedicated assay facility to operate it and carry out routine maintenance of that equipment has been conducting at the radwaste treatment facility. Since that facility will be constructed in front of a 1st radwaste storage facility as well as the radwaste drums to be assayed and the transmission source in the radwaste drum assay system are in that facility, they could act as the radioactive sources and then, would affect the dose rate at the inside and the outside of the facility. Therefore, the radiation shielding should be evaluated through the concrete wall near to the radioactive sources whether the wall thickness is sufficient against the regulations. In this study, the radiation safety for the concrete wall around the radiation controlled area in the radwaste drum assay facility was evaluated by the MCNP code. From the evaluation results, the thickness of those concrete walls which are under consideration of about 30 cm was enough to shield the radiation from the radioactive sources.

Aphicidal Activity of Starfish (Asterina pectinifera) Extracts against Green Peach Aphid (Myzus Persicae) (불가사리 추출물의 복숭아혹진딧물(Myzus Persicae) 살충활성)

  • Jang, Ja-Yeong;Yi, Sol;Jung, Iee-Young;Choi, Eun-Hyun;Jo, Uk-Hee;Seo, Jung-Mi;Yang, Si-Young;Kim, In-Seon
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.2
    • /
    • pp.173-178
    • /
    • 2011
  • BACKGROUND: Starfish is one of major sea invertebrates that have become a serious economic threat to aquacultural farms in Korea. Much effort has sacrificed to reduce the economic losses of the farms by predatory starfish, including developing and searching biological resources for medicinal and agricultural purposes. In the present study, we investigated aphicidal activity of the extracts from the starfish Asterina pectinifera against green peach aphid. METHODS AND RESULTS: Fresh starfishes were cut into small pieces, homogenized and soaked in methanol. The methanol extracts were centrifuged and the resulting supernatant was subjected to aphicidal activity assays and a series of silica gel column chromatography. More than 70% mortality of aphids were observed by the extracts at a concentration of 1,000 mg/L, exhibiting dose-dependent mortality. TOF-MS analyses detected polyhydroxysteroid as a main aphicidal compound from the starfish extracts. Transmission electronic microscopy could demonstrate that the extracts with polyhydroxysteroid caused aphids death by affecting their epicuticular membrane. CONCLUSION(s): This is the first report of aphicidal activity of the starfish Asterina pectinifera extracts against green peach aphid. Starfish biological resources may be used as a potential candidate for developing a new type natural insecticide.

In vivo Growth Inhibition of Sarcoma-180 Cells by a β-Glucan from the Mushroom Ganoderma lucidum (영지(Ganoderma lucidum)의 β-Glucan에 의한 Sarcoma-180 육종암 생장 억제)

  • Han, Man-Deuk;Kim, Yong Hyun;Kim, Wan Jong
    • Journal of Life Science
    • /
    • v.24 no.7
    • /
    • pp.721-727
    • /
    • 2014
  • Mushroom-derived ${\beta}$-glucan, a polysaccharide (GLP) isolated from the mycelium of Ganoderma lucidum, was previously shown to have inhibitory effects against tumor-bearing mice in vivo. We investigated the apoptotic effect of mushroom-derived ${\beta}$-glucan in a sarcoma-180 tumor cell- bearing mice model using an ELISA to determine the levels of tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) in the mice. The morphology of the tumor cells was assessed with transmission electron microscopy (TEM). GLP was injected into the tumor-bearing mice at a dose (i.p.) of 20 mg/kg for 10 days. After 30 days, the tumor mass from the inguinal region was collected, weighed, and assayed using TEM and a TNF-${\alpha}$ ELISA kit. The tumors that developed in the mice treated with GLP were 71.4% smaller than those in the control group, showing the ability of GLP to inhibit tumor growth. The levels of TNF-${\alpha}$ in the serum of the sarcoma-180 bearing mice were 12 times greater than in the serum of the nonbearing tumor mice. An ultrastructural study demonstrated that the GLP-treated sarcoma-180 tumor cells were condensed, with rearranged chromatin. In addition, the marginated chromatin in nucleus induced the nuclear compartment, and there were many vacuolization in the cell. GLP could be an effective apoptosis-inducing compound in sarcoma-type cancers.

Effects of the Ge Prearmophization Ion Implantation on Titanium Salicide Junctions (게르마늄 Prearmophization 이온주입을 이용한 티타늄 salicide 접합부 특성 개선)

  • Kim, Sam-Dong;Lee, Seong-Dae;Lee, Jin-Gu;Hwang, In-Seok;Park, Dae-Gyu
    • Korean Journal of Materials Research
    • /
    • v.10 no.12
    • /
    • pp.812-818
    • /
    • 2000
  • We studied the effects of Ge preamorphization (PAM) on 0.25$\mu\textrm{m}$ Ti-salicide junctions using comparative study with As PAM. For each PAM schemes, ion implantations are performed at a dose of 2E14 ion/$\textrm{cm}^2$ and at 20keV energy using $^{75}$ /As+and GeF4 ion sources. Ge PAM showed better sheet resistance and within- wafer uniformity than those of As PAM at 0.257m line width of n +/p-well junctions. This attributes to enhanced C54-silicidation reaction and strong (040) preferred orientation of the C54-silicide due to minimized As presence at n+ junctions. At p+ junctions, comparable performance was obtained in Rs reduction at fine lines from both As and Ge PAM schemes. Junction leakage current (JLC) revels are below ~1E-14 A/$\mu\textrm{m}^{2}$ at area patterns for all process conditions, whereas no degradation in JLC is shown under Ge PAM condition even at edge- intensive patterns. Smooth $TiSi_2$ interface is observed by cross- section TEM (X- TEM), which supports minimized silicide agglomeration due to Ge PAM and low level of JLC. Both junction break- down voltage (JBV) and contact resistances are satisfactory at all process conditions.

  • PDF

Image Quality Improvement through Energy Spectrum Change for X-ray (엑스선 에너지스펙트럼 변경을 통한 영상 화질 향상에 관한 연구)

  • Kim, Gu;Kim, Neung Gyun;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.71-78
    • /
    • 2021
  • When continuous X-ray are used when acquiring and X-ray image, even the same material may not be accurately represented in the image according to the thickness due to various X-ray energies. To solve this problem, the X-ray energy spectrum was changed to improve the image quality. Using SPEKTR v3.0, an X-ray energy spectrum with an additional filter added and a general X-ray energy spectrum using only a unique filter were obtained. Simulation was performed using the obtained X-ray energy spectrum as a radiation source for Geant4 Application for Tomographic Emission (GATE). Using GATE data, an X-ray image with an additional filter and an image reconstructed from and X-ray image without an additional filter were compared and analyzed through a mono energy image of 74 keV. In the case of using the X-ray energy spectrum without using an additional filter, the amount of X-rays transmitted according to the thickness of the same material is different from the amount that decreases according to the thickness of the material. Similar results were obtained as the amount decreased with the material thickness. In other words, a similar result was obtained when the reduced dose was used with a mono energy. When an X-ray image is obtained by changing an X-ray energy spectrum using an additional filter, a more accurate result of transmission of X-rays may be obtained. In radiological examination, it was confirmed that the appropriate use of the additional filter has a great effect on improving the image quality.

Development of High-Sensitivity and Entry-Level Radiation Measuring Sensor Module (고감도 보급형 방사선 측정센서 모듈 개발)

  • Oh, Seung-Jin;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.510-514
    • /
    • 2022
  • In this paper, we propose the development of high-sensitivity low-end radiation measuring sensor module. The proposed measurement sensor module is a scintillator + photomultiplier(SiPM) sensor optimization structure design, amplification and filter and control circuit design for sensor driver, control circuit design including short-distance communication, sensor mechanism design and manufacturing, and GUI development applied to prototypes consists of, etc. The scintillator + photomultiplier(SiPM) sensor optimization structure design is designed by checking the characteristics of the scintillator and the photomultiplier (SiPM) for the sensor structure design. Amplification, filter and control circuit design for sensor driver is designed to process fine scintillation signal generated by radiation with a scintillator using SiPM. Control circuit design including short-distance communication is designed to enable data transmission through MCU design to support short-range wireless communication function and wired communication support. The sensor mechanism design and manufacture is designed so that the glare generated by wrapping a reflective paper (mirroring) on the outside of the plastic scintillator is reflected to increase the efficiency in order to transmit the fine scintillation signal generated from the plastic scintillator to the photomultiplier(SiPM). The GUI development applied to the prototype expresses the date and time at the top according to each screen and allows the measurement unit and time, seconds, alarm level, communication status, battery capacity, etc. to be expressed. In order to evaluate the performance of the proposed system, the results of experiments conducted by an authorized testing institute showed that the radiation dose measurement range was 30 𝜇Sv/h ~ 10 mSv/h, so the results are the same as the highest level among products sold commercially at domestic and foreign. In addition, it was confirmed that the measurement uncertainty of ±7.4% was measured, and normal operation was performed under the international standard ±15%.

The Effects of Steroid on Acute Lung Injury in the Mouse Induced by Whole Lung Irradiation (전폐조사로 유발된 마우스의 급성폐손상에 대한 스테로이드의 효과)

  • Sung, Nak-Kwan;Shin, Sei-One;Kwon, Kun-Young
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.37-47
    • /
    • 1997
  • Purpose : To investigate ultrastructural changes of the mouse lung induced by whole lung gamma irradiation and to evaluate the effect of prophylactic administration of steroid against acute lung injury. Materials and Methods :. One hundred and twenty ICR mice were used and whole lung was irradiated with telecobalt machine. Whole lung doses were 8 and 12Gy, and 10mg of methyl prednisolone was administrated intraperitoneally for two and four weeks. At the end of the observation period, mice were sacrificed by cervical dislocation. The lungs were removed and fixed inflated. Histopathological examination of acute radiation injuries were Performed by light microscopic and transmission electron microscopic examination. Results : Control group with BGy is characterized by damage to the type I Pneumocyte and the endothelial cell of the capillary. edema of alveolar wall and interstitium. and fibroblast proliferation. Control group with 120y is characterized by more severe degree of type 1 pneumocyte damage and more prominant inflammatory cell infiltration. Destructed cell debris within the alveolar space were also noted After steroid administration, 8Gy experimental group showed decreased degree of inflammatory reactions but fibroblast proliferation and basal lamina damages were unchanged. Experimental group with 12Gy showed lesser degree of inflammatory reactions similar to changes of 8Gy experimental group. Conclusion : These studies suggest that the degree of interstitial edema and inflammatory changes were related to radiation dose but Proliferation of the fibroblast and structural changes of basal lamina were not related to radialion dose. Experimental administration of steroid for 2 to 4 weeks after whole lung irradiation suggest that steroid can suppress alveolar and endothelial damages induced by whole lung irradiation but Proliferation of the fibroblast and structural changes of basal lamina were not related to administration of steroid.

  • PDF