A Study for Stress Distribution of the High-voltage Transmission Tower Under Wind Forces (풍하중이 작용하는 고용량 송전철탑의 해석을 통한 응력 분포 고찰)

  • Chang, Jin-Won;Kim, Seung-Jun;Park, Jong-Sub;Kang, Young-Jong
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.75-78
    • /
    • 2007
  • The structural methodology in designing a transmission tower have been performed to assume a simple truss behavior. But there're quite differences between a simple truss behavior and a real one. A suitable explanation for a structural stability can be expressed as a semi-rigid connection instead of the assumed hinged connection. This study proposes an alternative structural analysis modelling strategy for the transmission tower design. Proposed element models are truss element model, beam element model, and combined beam-truss element model. The static finite element analysis shows that there's a moment distribution between a mainpost member and the other bracing member.

  • PDF

A New Method to Handle Transmission Losses using LDFs in Electricity Market Operation

  • Ro Kyoung-Soo;Han Se-Young
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.193-198
    • /
    • 2005
  • This paper proposes a new method to handle transmission line losses using loss distribution factors (LDF) rather than marginal loss factors (MLF) in electricity market operation. Under a competitive electricity market, the bidding data are adjusted to reflect transmission line losses. To date the most proposed approach is using MLFs. The MLFs are reflected to bidding prices and market clearing price during the trading and settlement of the electricity market. In the proposed algorithm, the LDFs are reflected to bidding quantities and actual generations/ loads. Computer simulations on a 9-bus sample system will verify the effectiveness of the algorithm proposed. Moreover, the proposed approach using LDFs does not make any payments residual while the approach using MLFs induces payments residual.

The Development of a Distribution Automation System with an Wireless Network (무선통신망을 이용한 배전자동화시스템 개발 연구)

  • Kim, Myong-Soo;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2747-2749
    • /
    • 2000
  • The KEPRI has been developing the medium/small scale Distribution Automation System(DAS) that adopts wireless transmission media for exchanging information between master and remote terminals. It was concluded that Short Message Service(SMS) of Personal Communication Service(PCS) was the best wireless transmission media for the medium/small scale DAS in the last year. However. we had problem that PCS had long transmission delay. Therefore. SMS phones will be substituted with Radio Link Protocol(RLP) modems having transmission delay less than 5 seconds. This paper describes wireless networks for DAS, practical experience.

  • PDF

Wind tunnel tests on wind loads acting on steel tubular transmission towers under skewed wind

  • YANG, Fengli;NIU, Huawei
    • Wind and Structures
    • /
    • v.35 no.2
    • /
    • pp.93-108
    • /
    • 2022
  • Steel tubular towers are commonly used in UHV and long crossing transmission lines. By considering effects of the model scale, the solidity ratio and the ratio of the mean width to the mean height, wind tunnel tests under different wind speeds on twenty tubular steel tower body models and twenty-six tubular steel cross-arm models were completed. Drag coefficients and shielding factors of the experimental tower body models and cross-arm models in wind directional axis for typical skewed angles were obtained. The influence of the lift forces on the skewed wind load factors of tubular steel tower bodies was evaluated. The skewed wind load factors, the wind load distribution factors in transversal and longitudinal direction were calculated for the tubular tower body models and cross-arm models, respectively. Fitting expressions for the skewed wind load factors of tubular steel bodies and cross-arms were determined through nonlinear fitting analysis. Parameters for skewed wind loads determined by wind tunnel tests were compared with the regulations in applicable standards. Suggestions on the drag coefficients, the skewed wind load factors and the wind load distribution factors were proposed for tubular steel transmission towers.

Development of Compliant and Dissipative Joints in Coupled Thin Plates for Vibrational Energy Flow Analysis (평판 구조물의 진동 파워흐름해석을 위한 비보존 조인트 개발)

  • Song, Jee-Hun;Hong, Suk-Yoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.10
    • /
    • pp.1082-1090
    • /
    • 2008
  • In this paper, a general solution for the vibrational energy and intensity distribution through a compliant and dissipative joint between plate structures is derived on the basis of energy flow analysis (EFA). The joints are modeled by four sets of springs and dashpots to show their compliancy and dissipation in all four degrees of freedom. First, for the EFA, the power transmission and reflection coefficients for the joint on coupled plate structures connected at arbitrary angles were derived by the wave transmission approach. In numerical applications, EFA is performed using the derived coefficients for coupled plate structures under various joint properties, excitation frequencies, coupling angles, and internal loss factors. Numerical results of the vibrational energy distribution showed that the developed compliant and dissipative joint model successfully predicted the joint characteristics of practical structures vibrating in the medium-to-high frequency ranges. Moreover, the intensity distribution of a compliant and dissipative joint is described.

Applicability Comparison of Transmission Line Parameter Extraction Methods for Busbar Distribution Systems

  • Hasirci, Zeynep;Cavdar, Ismail Hakki;Ozturk, Mehmet
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.586-593
    • /
    • 2017
  • Modeling busbar distribution system as a transmission line is an important subject of power line communication in the smart grid concept. This requires extraction of busbar RLGC parameters, accurately. In this study, a comparison is made between conventional and modified method for the aspect of optimum RLGC parameters extraction in the 1 MHz to 50 MHz frequency band. The usefulness of these methods is shown both in time and frequency-domain analysis. The frequency-domain analyzes show that the inherent power of modified method can eliminate the errors especially due to the discontinuities arise in conventional method. This makes the modeling approach of modified method more advantageous for the busbars due to its robustness against disturbances in the S-parameters measurements which cannot be eliminated with the calibration procedure. On the other hand, time-domain simulations show that the transmission line representation of the modified method is closer to physical reality by handling causality issues.

SHD Digital Cinema Distribution over a Fast Long-Distance Network

  • Takahiro Yamaguchi;Daisuke Shirai;Mitsuru Nomura;Kazuhiro Shirakawa;Tatsuya Fujii;Tetsuro Fujii;Kim, io-Oguchi
    • Journal of Broadcast Engineering
    • /
    • v.9 no.2
    • /
    • pp.119-130
    • /
    • 2004
  • We have developed a prototype super-high-definition (SHD) digital cinema distribution system that can store, transmit, and display eight-million-pixel motion pictures that have the image quality of a 35-mm film movie. The system contains a movie server, a real-time decoder, and an SHB projector. Using a Gigabit Ethernet link and TCP/IP, the server transmits JPEG2000 compressed motion picture data streams to the decoder at transmission speeds as high as 300 Mbps. The received data streams are decompressed by the decoder, and then projected onto a screen via the projector. By using an enlarged TCP window, multiple TCP streams, and a shaping function to control the data transmission quantity, we achieved real-time streaming of SHD movie data at about 300 Mbps between Chicago and Los Angeles, a distance of more than 3000 km. We also improved the decoder performance to show movies with Image qualities of 450 Mbps or higher. Since UDP is more suitable than TCP for fast long-distance streaming, we have developed an SHD digital cinema UDP relay system, in which UDP is used for transmission over a fast long-distance network. By using four pairs of server-side-proxy and decoder-side-proxy, 450-Mbps movie data streams could be transmitted.

A data-driven method for the reliability analysis of a transmission line under wind loads

  • Xing Fu;Wen-Long Du;Gang Li;Zhi-Qian Dong;Hong-Nan Li
    • Steel and Composite Structures
    • /
    • v.52 no.4
    • /
    • pp.461-473
    • /
    • 2024
  • This study focuses on the reliability of a transmission line under wind excitation and evaluates the failure probability using explicit data resources. The data-driven framework for calculating the failure probability of a transmission line subjected to wind loading is presented, and a probabilistic method for estimating the yearly extreme wind speeds in each wind direction is provided to compensate for the incompleteness of meteorological data. Meteorological data from the Xuwen National Weather Station are used to analyze the distribution characteristics of wind speed and wind direction, fitted with the generalized extreme value distribution. Then, the most vulnerable tower is identified to obtain the fragility curves in all wind directions based on uncertainty analysis. Finally, the failure probabilities are calculated based on the presented method. The simulation results reveal that the failure probability of the employed tower increases over time and that the joint probability distribution of the wind speed and wind direction must be considered to avoid overestimating the failure probability. Additionally, the mixed wind climates (synoptic wind and typhoon) have great influence on the estimation of structural failure probability and should be considered.

Analysis of the Distribution STATCOM Operating Results for Improving Distribution System Power Quality (전력품질 향상을 위한 배전용 STATCOM 운전결과 분석)

  • 오관일;전영수;박상태;추진부
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.377-385
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. The custom power is similar in nature to the concept of FACTS(Flexibel AC Transmission System). By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources. STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, providing reactive power compensation, voltage regulation and mitigation of voltage flicker. It is shown that the STATCOM has clear advantages in areas such as; providing reactive power compensation and improving power factor.

  • PDF

PTW Application Method for Analysis the Industrial Distribution System (PTW를 이용한 산업용 수변전계통의 운영방안)

  • 설용태;이의용;이배희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.22-28
    • /
    • 2000
  • In this paper PTW(Power Tools for Windows) application method for analysis the industrial distribution system is proposed. T&D(Transmission and Distribution) and BICC methods is applied for the cable impedance and the X/R of transformer data is estimated by IEEE standard. The effectiveness of this method was improved by the electrical characteristics analysis of the real industrial distribution system.

  • PDF